Beyerdynamic M160 User Manual

Hypercardioid Double Ribbon Microphone
DESCRIPTION
The M 160’s low-mass, low-inertia ribbons
reproduce transients with complete accuracy to create a crisply detailed sound and a transparent acoustic ‘image’. The true hyper­cardioid pattern provides 25 dB attenuation at 11 O”, suppressing lateral interference and allowing high gain levels without feedback. The accurate, uncolored sound of the M 160
is suited to a wide variety of demanding
recording and sound reinforcement applica­tions Paired with the bidirectional M 130, it
creates an authentic stereo image in the M-S
(Mid-Side) miking technique. The compact
metal casing has a matte black chromium
plating with extremely low reflectivity, an important consideration in television and film applications.
The M 160s breakthrough design employs two aluminum ribbons in a vertical array only
.0002 inches apart. Each’ ribbon is less than one twelve-thousandth of an inch thick, and much shorter than conventional ribbons. A special forming process makes them highly
resistant to overload or mechanical shock.
FEATURES
l
Unique double ribbon transducer
l
True hypercardioid polar characteristic
l
Extended frequency response
l
Compact design
APPLICATIONS
The M 160 produces excellent results in both remote and studio recordings of vocal or instrumental source material. In the recording studio, it is especially recommended for acoustic guitar, banjo, snare drum, piano, flute and violin. Its full, natural sound and accurate transient response are perfectly suited to the stringent requirements of con­temporary audiophile techniques such as digital recording. With its companion M 130, the M 160 is ideal for demanding broadcast applications where the Mid-Side technique is used to create a true stereo image.
FREQUENCY RESPONSE CURVE (f 2.5 dB)
POLAR PATTERN
o”
w
This polar pattern and frequency response curve correspond to typical machIne run speclflcatlons from a standard M 160
SPECIFICATIONS
Transducer type Operating prfnciple Frequency response Polar pattern Side attenuation at 1 loo (1 kHz) Open clrcu~t voltage at 1 kHz Output level EIA Sensltlvlty rating
Nomlnal output impedance Load Impedance Diaphragm Case Case flnlsh
Male connector Net weight (less cable)
Dual dynamic ribbon Pressure gradlent 40 18,000 Hz Hypercardlotd
> 25dB
1 0 mV/Pa
- 59 dBm (0 dBm Al mW/Pa)
- 152 dBm (0 dBm 61 mW/ZxlOsPa)
200 ohms 2 1000 ohms Pure aluminum
Brass Shaft matte black chromium plating Top chrome mesh Neutrlk 3 pin
156 grams (5 5 OL )
WIRING DIAGRAM
1/a *en
Posltlve pressure produces positive voltage on yellow cable lead (+)
FURNISHED ACCESSORIES
Carrying case MIC CIIP
Black leatherette foam lined MKV8
OPTIONAL ACCESSORIES
Cable
MIC clip WIndscreen
MVK C-C/PO black 20 ft two~conductor spiral shield synthetic rubber jacketed with black Neutrlk 3 pin female XLR connector on mlc end and black Neutrlk 3 pin male XLR connector on equipment end MVK C~C also avaIlable in 25 and 50 ft lengths and with 114” two-conductor plug at equipment end MKV 6 quick release WS 260 polyurethane foam
DIMENSIONS
In mllllmeters (Inches In brackets)
1 38
--
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
The mIcrophone shall be a unldlrectlonal dynamic type with a frequency range of 40 18,000 Hz The generatlng element of the unit shall be a special double ribbon transducer The unit shall have a true hypercardtold polar characterlstlc Attenuation at 1 IO” shall exceed 25 dB The mlcrophone output shall be ~59 dBm when 0 dBm z!J 1 mW/Pa respectively 1 mV/Pa EIA sensltlvlty at 1,000 Hz shall be - 152 dBm Electrical Impedance shall be 200 ohms The case shall be made of brasFflnlshed jr- matte black chromium plating, with a chrome mesh top The dimensions shall be 6 1 in (156 mm) overall length, head diameter of 1 5 In (38 mm) and shaft diameter of 0 9 in (23 mm) The mlcrophone shall be avaIlable with a Neutrlk 3 pfn male connector or equivalent The Beyer Dynamic model M 160 IS speclfled
Subject to change wlthout notlce
Loading...