Bertazzoni REF24FCIPRL, REF36RCPIXL, REF24WCPIXL, REF36RCPIXR, REF36RCPRL Design Guide

...
BUILT-IN REFRIGERATOR COLUMNS BUILT-IN FREEZER COLUMNS BUILT-IN WINE COLUMNS
DESIGN GUIDE
1.0
BUILT-IN COLUMNS
These premium refrigerators, freezers and wine columns are masterpieces of design and technology. Their stylish appearance reflects close attention to detail and high-quality materials, inside and out. The stainless steel front and panel ready doors are mounted with state-of-the-art engineered lift-and­swing hinges that give the perception of a weightless range of motion. Versatile installation options make it possible to bring together elegant configurations of the refrigerator, freezer and wine columns in any desired width. All three columns work in harmony with handles and finishes available for every Series.
INDEX
INTRODUCTION 3
BUILT-IN REFRIGERATOR COLUMNS 4
36” Refrigerator Column Panel Installed 6
36” Refrigerator Column Panel Ready 9
30” Refrigerator Column Panel Installed 12
30” Refrigerator Column Panel Ready 15
24” Refrigerator Column Panel Installed 18
24” Refrigerator Column Panel Ready 21
BUILT-IN FREEZER COLUMNS 24
30” Freezer Column Panel Installed 26
30” Freezer Column Panel Ready 29
24” Freezer Column Panel Installed 32
24” Freezer Column Panel Ready 35
BUILT-IN WINE COLUMNS 44
24” Wine Column Panel Installed 46
24” Wine Column Panel Ready 49
18” Wine Column Panel Installed 52
18” Wine Column Panel Ready 55
MULTIPLE INSTALLATIONS 58
42” Double Configurations 61
48” Double Configurations 62
54” Double Configurations 63
60” Double Configurations 64
60” Triple Configurations 65
66” Triple Configurations 66
72” Triple Configurations 67
90” Triple Configurations 68
18” Freezer Column Panel Installed 38
18” Freezer Column Panel Ready 41
Custom Door Panel 69
Recommended Installations 70
Refrigeration Handles 71
Toekick Panel 72
3bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
36” - 30” - 24” Panel Ready and Panel Installed
4 bertazzoni.com
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
36” Refrigerator Column Panel Installed
Dimensions
REF36RCPIXL left hinge REF36RCPIXR right hinge
Handle choices
Professional Series: PROHKCOL Master series: MASHKCOL Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
35 5/8"
904
DOOR
WIDTH
77 3/4"
1974
5 3/4"
146
77 3/4"
1974
+ 1"(25)
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
35 5/8"
904
DOOR
WIDTH
5 1/2"
*
139
58 1/2"
1487
24 3/8"
620
35 15/16"
913
100°
35 15/16"
913
100°
24 3/8"
620
5 1/2"
58 1/2"
1487
139
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension For detailed handle dimensions see page 71
6 bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
TOP VIEW
36” Refrigerator Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product.
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
Required floor support 1532 lb (695 kg ) Electrical supply 115 V 60 Hz 218 W 2 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
7bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
36” Refrigerator Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130 Min.
25"
635
36" 914
a
a
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)
8 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
36” Refrigerator Column Panel Ready
Dimensions
REF36RCPRL left hinge REF36RCPRR right hinge
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
*
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
6 1/4"
158
58 5/8"
1489
24 1/4"
615
35 15/16"
913
100°
35 15/16"
913
100°
24 1/4"
615
6 1/4"
158
58 5/8"
1489
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension ** Width of 3/4” (19mm) Door Panel For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
9bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
TOP VIEW
36” Refrigerator Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
10 bertazzoni.com
Required floor support 1532 lb (695 kg )
Electrical supply 115 V 60 Hz 218 W 2 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN REFRIGERATOR COLUMNS
36” Refrigerator Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25"
635
FRONT VIEW
36" 914
a
a
b
83 7/8"
2130 Min.
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm) (b) Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
11bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
30” Refrigerator Column Panel Installed
Dimensions
REF30RCPIXL left hinge REF30RCPIXR right hinge
Handle choices
Professional Series: PROHKCOL Master series: MASHKCOL Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
29 5/8"
752
DOOR
WIDTH
77 3/4"
1974
5 3/4"
146
77 3/4"
1974
+ 1"(25)
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
29 5/8"
752
DOOR
WIDTH
4"
*
103
52 5/8"
1336
24 3/8"
620
29 15/16"
761
100°
29 15/16"
761
100°
24 3/8"
620
103
52 5/8"
4"
1336
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension For detailed handle dimensions see page 71
12 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product.
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
Required floor support 1257 lb (570 kg )
Electrical supply 115 V 60 Hz 218 W 2 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
13bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130 Min.
25" 635
30" 762
a
a
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)
14 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
30” Refrigerator Column Panel Ready
Dimensions
REF30RCPRL left hinge REF30RCPRR right hinge
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
*
5 1/4"
**
132
52 5/8"
1338
24 1/4"
615
29 15/16"
761
100°
29 15/16"
761
100°
24 1/4"
615
5 1/4"
52 5/8"
1338
132
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension ** Width of 3/4” (19mm) Door Panel For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
15bertazzoni.com
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
16 bertazzoni.com
Required floor support 1257 lb (570 kg )
Electrical supply 115 V 60 Hz 218 W 2 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25" 635
FRONT VIEW
30"
762
a
a
b
83 7/8"
2130 Min.
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm) (b) Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
17bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
24” Refrigerator Column Panel Installed
Dimensions
REF24RCPIXL left hinge REF24RCPIXR right hinge
Handle choices
Professional Series: PROHKCOL Master series: MASHKCOL Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
23 5/8"
600
DOOR
WIDTH
77 3/4"
1974
5 3/4"
+ 1"(25)
146
77 3/4"
1974
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
23 5/8"
600
DOOR
WIDTH
3 1/2"
*
24 3/8"
89
46 5/8"
1185
620
24" 609
100°
24" 609
100°
24 3/8"
620
3 1/2"
46 5/8"
89
1185
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension For detailed handle dimensions see page 71
18 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
24” Refrigerator Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product.
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
Required floor support 992 lb (450 kg ) Electrical supply 115 V 60 Hz 163 W 1.5 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
19bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
24” Refrigerator Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130 Min.
25" 635
24"
610
aa
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)
20 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
24” Refrigerator Column Panel Ready
Dimensions
REF24RCPRL left hinge REF24RCPRR right hinge
22 1/4"
565
5"
5"
127
127
2 3/4"
2 3/4"
70
70
5"
5"
127
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
4 1/4"
*
46 3/4"
1187
108
24 1/4"
615
24" 609
100°
24"
609
100°
24 1/4"
615
4 1/4"
46 3/4"
1187
108
*
**
2 3/4"
2 3/4"
70
70
19 7/8"
505
* Maximum Overall Handle Dimension ** Width of 3/4” (19mm) Door Panel For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
21bertazzoni.com
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
24” Refrigerator Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
22 bertazzoni.com
Required floor support 992 lb (450 kg ) Electrical supply 115 V 60 Hz 163 W 1.5 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
Loading...
+ 51 hidden pages