These premium refrigerators, freezers and wine
columns are masterpieces of design and technology.
Their stylish appearance reflects close attention to
detail and high-quality materials, inside and out.
The stainless steel front and panel ready doors are
mounted with state-of-the-art engineered lift-andswing hinges that give the perception of a weightless
range of motion. Versatile installation options make
it possible to bring together elegant configurations
of the refrigerator, freezer and wine columns in any
desired width. All three columns work in harmony
with handles and finishes available for every Series.
INDEX
INTRODUCTION 3
BUILT-IN REFRIGERATOR COLUMNS 4
36” Refrigerator Column Panel Installed 6
36” Refrigerator Column Panel Ready 9
30” Refrigerator Column Panel Installed 12
30” Refrigerator Column Panel Ready 15
24” Refrigerator Column Panel Installed 18
24” Refrigerator Column Panel Ready 21
BUILT-IN FREEZER COLUMNS 24
30” Freezer Column Panel Installed 26
30” Freezer Column Panel Ready 29
24” Freezer Column Panel Installed 32
24” Freezer Column Panel Ready 35
BUILT-IN WINE COLUMNS 44
24” Wine Column Panel Installed 46
24” Wine Column Panel Ready 49
18” Wine Column Panel Installed 52
18” Wine Column Panel Ready 55
MULTIPLE INSTALLATIONS 58
42” Double Configurations 61
48” Double Configurations 62
54” Double Configurations 63
60” Double Configurations 64
60” Triple Configurations 65
66” Triple Configurations 66
72” Triple Configurations 67
90” Triple Configurations 68
18” Freezer Column Panel Installed 38
18” Freezer Column Panel Ready 41
Custom Door Panel 69
Recommended Installations 70
Refrigeration Handles 71
Toekick Panel 72
3bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
36” - 30” - 24”
Panel Ready and
Panel Installed
4bertazzoni.com
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
36” Refrigerator Column Panel Installed
Dimensions
REF36RCPIXL left hinge
REF36RCPIXR right hinge
Handle choices
Professional Series: PROHKCOL
Master series: MASHKCOL
Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
35 5/8"
904
DOOR
WIDTH
77 3/4"
1974
5 3/4"
146
77 3/4"
1974
+ 1"(25)
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
35 5/8"
904
DOOR
WIDTH
5 1/2"
*
139
58 1/2"
1487
24 3/8"
620
35 15/16"
913
100°
35 15/16"
913
100°
24 3/8"
620
5 1/2"
58 1/2"
1487
139
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension
For detailed handle dimensions see page 71
6bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
TOP VIEW
36” Refrigerator Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
E
EE
FRONT VIEW
EEE
5"
127
MAX
A separate circuit breaker servicing only this appliance is
recommended.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
Dimensions in parentheses are millimeters unless otherwise specified.
7bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
36” Refrigerator Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130
Min.
25"
635
36"
914
a
a
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
8bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
36” Refrigerator Column Panel Ready
Dimensions
REF36RCPRL left hinge
REF36RCPRR right hinge
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
*
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
6 1/4"
158
58 5/8"
1489
24 1/4"
615
35 15/16"
913
100°
35 15/16"
913
100°
24 1/4"
615
6 1/4"
158
58 5/8"
1489
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension
** Width of 3/4” (19mm) Door Panel
For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
9bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
TOP VIEW
36” Refrigerator Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For panel ready columns, do not exceed the maximum
weight of 75 pounds (34 kg) for door panel. Panel can have
thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
E
EE
FRONT VIEW
EEE
5"
127
MAX
A separate circuit breaker servicing only this appliance is
recommended.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
10bertazzoni.com
Required floor support1532 lb (695 kg )
Electrical supply115 V60 Hz218 W2 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN REFRIGERATOR COLUMNS
36” Refrigerator Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25"
635
FRONT VIEW
36"
914
a
a
b
83 7/8"
2130
Min.
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
(b) Panel dimensions available on Built-in Food Preservation
Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
11bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
30” Refrigerator Column Panel Installed
Dimensions
REF30RCPIXL left hinge
REF30RCPIXR right hinge
Handle choices
Professional Series: PROHKCOL
Master series: MASHKCOL
Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
29 5/8"
752
DOOR
WIDTH
77 3/4"
1974
5 3/4"
146
77 3/4"
1974
+ 1"(25)
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
29 5/8"
752
DOOR
WIDTH
4"
*
103
52 5/8"
1336
24 3/8"
620
29 15/16"
761
100°
29 15/16"
761
100°
24 3/8"
620
103
52 5/8"
4"
1336
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension
For detailed handle dimensions see page 71
12bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
E
EE
FRONT VIEW
EEE
5"
127
MAX
A separate circuit breaker servicing only this appliance is
recommended.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
Required floor support1257 lb (570 kg )
Electrical supply115 V60 Hz218 W2 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
13bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130
Min.
25"
635
30"
762
a
a
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
14bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
30” Refrigerator Column Panel Ready
Dimensions
REF30RCPRL left hinge
REF30RCPRR right hinge
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
*
5 1/4"
**
132
52 5/8"
1338
24 1/4"
615
29 15/16"
761
100°
29 15/16"
761
100°
24 1/4"
615
5 1/4"
52 5/8"
1338
132
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension
** Width of 3/4” (19mm) Door Panel
For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
15bertazzoni.com
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For panel ready columns, do not exceed the maximum
weight of 75 pounds (34 kg) for door panel. Panel can have
thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
E
EE
FRONT VIEW
EEE
5"
127
MAX
A separate circuit breaker servicing only this appliance is
recommended.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
16bertazzoni.com
Required floor support1257 lb (570 kg )
Electrical supply115 V60 Hz218 W2 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25"
635
FRONT VIEW
30"
762
a
a
b
83 7/8"
2130
Min.
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
(b) Panel dimensions available on Built-in Food Preservation
Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
17bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
24” Refrigerator Column Panel Installed
Dimensions
REF24RCPIXL left hinge
REF24RCPIXR right hinge
Handle choices
Professional Series: PROHKCOL
Master series: MASHKCOL
Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
23 5/8"
600
DOOR
WIDTH
77 3/4"
1974
5 3/4"
+ 1"(25)
146
77 3/4"
1974
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
23 5/8"
600
DOOR
WIDTH
3 1/2"
*
24 3/8"
89
46 5/8"
1185
620
24"
609
100°
24"
609
100°
24 3/8"
620
3 1/2"
46 5/8"
89
1185
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension
For detailed handle dimensions see page 71
18bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
24” Refrigerator Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
E
EE
FRONT VIEW
EEE
5"
127
MAX
A separate circuit breaker servicing only this appliance is
recommended.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
Dimensions in parentheses are millimeters unless otherwise specified.
19bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
24” Refrigerator Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130
Min.
25"
635
24"
610
aa
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
20bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
24” Refrigerator Column Panel Ready
Dimensions
REF24RCPRL left hinge
REF24RCPRR right hinge
22 1/4"
565
5"
5"
127
127
2 3/4"
2 3/4"
70
70
5"
5"
127
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
4 1/4"
*
46 3/4"
1187
108
24 1/4"
615
24"
609
100°
24"
609
100°
24 1/4"
615
4 1/4"
46 3/4"
1187
108
*
**
2 3/4"
2 3/4"
70
70
19 7/8"
505
* Maximum Overall Handle Dimension
** Width of 3/4” (19mm) Door Panel
For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
21bertazzoni.com
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
24” Refrigerator Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For panel ready columns, do not exceed the maximum
weight of 75 pounds (34 kg) for door panel. Panel can have
thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
E
EE
FRONT VIEW
EEE
5"
127
MAX
A separate circuit breaker servicing only this appliance is
recommended.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN REFRIGERATOR COLUMNS
24” Refrigerator Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25"
635
FRONT VIEW
aa
b
24"
610
83 7/8"
2130
Min.
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
(b) Panel dimensions available on Built-in Food Preservation
Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
23bertazzoni.com
BUILT-IN FREEZER COLUMNS
30” - 24” - 18”
Panel Ready and
Panel Installed
24bertazzoni.com
25bertazzoni.com
BUILT-IN FREEZER COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
30” Freezer Column Panel Installed
Dimensions
REF30FCPIXL left hinge
REF30FCPIXR right hinge
Handle choices
Professional Series: PROHKCOL
Master series: MASHKCOL
Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
29 5/8"
752
DOOR
WIDTH
77 3/4"
1974
5 3/4"
146
77 3/4"
1974
+ 1"(25)
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
29 5/8"
752
DOOR
WIDTH
4"
*
103
52 5/8"
1336
24 3/8"
620
29 15/16"
761
100°
29 15/16"
761
100°
24 3/8"
620
103
52 5/8"
4"
1336
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension
For detailed handle dimensions see page 71
26bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN FREEZER COLUMNS
30” Freezer Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For instructions of product combinations please see the
Multiple Installation Section (page 58).
FRONT VIEW
W
E
W
E
W
E
E
W
E
5"
127
W
W
E
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
Required floor support1257 lb (570 kg )
A separate circuit breaker servicing only this appliance is
recommended.
Electrical supply115 V60 Hz327 W3 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter
assembly which must be mounted outside the unit.
The appliance must be connected only to a potable water
supply system.
To connect to water supply system (for appliances equipped
with ice maker) a ¼” waterline with accessible shut-off valve
must be supplied.
The solenoid connection on the appliance is ¾” diameter but
is metric threaded (NPT).
The system pressure must be between from 8 PSI to 75 PSI
(between 0.5 bar and 5 bar). Different pressures can cause
malfunctions or leaks in the water system.
For information on how to purchase the water filter, please
see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
Dimensions in parentheses are millimeters unless otherwise specified.
27bertazzoni.com
BUILT-IN FREEZER COLUMNS
30” Freezer Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130
Min.
25"
635
30"
762
a
a
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
28bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
BUILT-IN FREEZER COLUMNS
30” Freezer Column Panel Ready
Dimensions
REF30FCPRL left hinge
REF30FCPRR right hinge
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
*
5 1/4"
**
132
52 5/8"
1338
24 1/4"
615
29 15/16"
761
100°
29 15/16"
761
100°
24 1/4"
615
5 1/4"
52 5/8"
1338
132
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension
** Width of 3/4” (19mm) Door Panel
For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
29bertazzoni.com
BUILT-IN FREEZER COLUMNS
TOP VIEW
30” Freezer Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For panel ready columns, do not exceed the maximum
weight of 75 pounds (34 kg) for door panel. Panel can have
thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
W
E
FRONT VIEW
W
E
W
E
E
W
E
5"
127
W
W
E
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
Required floor support1257 lb (570 kg )
A separate circuit breaker servicing only this appliance is
recommended.
Electrical supply115 V60 Hz327 W3 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter
assembly which must be mounted outside the unit.
The appliance must be connected only to a potable water
supply system.
To connect to water supply system (for appliances equipped
with ice maker) a ¼” waterline with accessible shut-off valve
must be supplied.
The solenoid connection on the appliance is ¾” diameter but
is metric threaded (NPT).
The system pressure must be between from 8 PSI to 75 PSI
(between 0.5 bar and 5 bar). Different pressures can cause
malfunctions or leaks in the water system.
For information on how to purchase the water filter, please
see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
30bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN FREEZER COLUMNS
30” Freezer Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25"
635
FRONT VIEW
30"
762
a
a
b
83 7/8"
2130
Min.
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
(b) Panel dimensions available on Built-in Food Preservation
Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
31bertazzoni.com
BUILT-IN FREEZER COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
24” Freezer Column Panel Installed
Dimensions
REF24FCPIXL left hinge
REF24FCPIXR right hinge
Handle choices
Professional Series: PROHKCOL
Master series: MASHKCOL
Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
23 5/8"
600
DOOR
WIDTH
77 3/4"
1974
5 3/4"
+ 1"(25)
146
77 3/4"
1974
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
23 5/8"
600
DOOR
WIDTH
3 1/2"
*
24 3/8"
89
46 5/8"
1185
620
24"
609
100°
24"
609
100°
24 3/8"
620
3 1/2"
46 5/8"
89
1185
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension
For detailed handle dimensions see page 71
32bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN FREEZER COLUMNS
24” Freezer Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product..
For instructions of product combinations please see the
Multiple Installation Section (page 58).
FRONT VIEW
W
E
W
E
W
E
E
W
E
5"
127
W
W
E
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
Required floor support992 lb (450 kg )
A separate circuit breaker servicing only this appliance is
recommended.
Electrical supply115 V60 Hz327 W3 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter
assembly which must be mounted outside the unit.
The appliance must be connected only to a potable water
supply system.
To connect to water supply system (for appliances equipped
with ice maker) a ¼” waterline with accessible shut-off valve
must be supplied.
The solenoid connection on the appliance is ¾” diameter but
is metric threaded (NPT).
The system pressure must be between from 8 PSI to 75 PSI
(between 0.5 bar and 5 bar). Different pressures can cause
malfunctions or leaks in the water system.
For information on how to purchase the water filter, please
see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
Dimensions in parentheses are millimeters unless otherwise specified.
33bertazzoni.com
BUILT-IN FREEZER COLUMNS
24” Freezer Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130
Min.
25"
635
24"
610
aa
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
34bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
BUILT-IN FREEZER COLUMNS
24” Freezer Column Panel Ready
Dimensions
REF24FCPRL left hinge
REF24FCPRR right hinge
22 1/4"
565
5"
5"
127
127
2 3/4"
2 3/4"
70
70
5"
5"
127
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
4 1/4"
*
46 3/4"
1187
108
24 1/4"
615
24"
609
100°
24"
609
100°
24 1/4"
615
4 1/4"
46 3/4"
1187
108
*
**
2 3/4"
2 3/4"
70
70
19 7/8"
505
* Maximum Overall Handle Dimension
** Width of 3/4” (19mm) Door Panel
For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
35bertazzoni.com
TOP VIEW
BUILT-IN FREEZER COLUMNS
24” Freezer Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For panel ready columns, do not exceed the maximum
weight of 75 pounds (34 kg) for door panel. Panel can have
thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
W
E
FRONT VIEW
W
E
W
E
E
W
E
5"
127
W
W
E
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
Required floor support992 lb (450 kg )
A separate circuit breaker servicing only this appliance is
recommended.
Electrical supply115 V60 Hz327 W3 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter
assembly which must be mounted outside the unit.
The appliance must be connected only to a potable water
supply system.
To connect to water supply system (for appliances equipped
with ice maker) a ¼” waterline with accessible shut-off valve
must be supplied.
The solenoid connection on the appliance is ¾” diameter but
is metric threaded (NPT).
The system pressure must be between from 8 PSI to 75 PSI
(between 0.5 bar and 5 bar). Different pressures can cause
malfunctions or leaks in the water system.
For information on how to purchase the water filter, please
see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
36bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN FREEZER COLUMNS
24” Freezer Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25"
635
FRONT VIEW
aa
b
24"
610
83 7/8"
2130
Min.
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
(b) Panel dimensions available on Built-in Food Preservation
Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
37bertazzoni.com
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
BUILT-IN FREEZER COLUMNS
18” Freezer Column Panel Installed
Dimensions
REF18FCIPIXL left hinge
REF18FCIPIXR right hinge
Handle choices
Professional Series: PROHKCOL
Master series: MASHKCOL
Heritage Series: HERHKCOL
22 1/4"
565
17 5/8"
447
DOOR
WIDTH
*
2 1/2"
63
17 15/16"
456
127
127
5"
2 3/4"
5"
24 3/8"
100°
620
2 1/2"
63
40 3/4"
1034
*
77 3/4"
80 3/4"
2050
+
1"(25)
70
19 7/8"
505
22 1/4"
565
80 3/4"
2050
+
1"(25)
1974
5 3/4"
+ 1"(25)
146
77 3/4"
1974
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
17 5/8"
447
DOOR
WIDTH
40 3/4"
1034
24 3/8"
620
17 15/16"
456
100°
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension
For detailed handle dimensions see page 71
38bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN FREEZER COLUMNS
18” Freezer Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For instructions of product combinations please see the
Multiple Installation Section (page 58).
FRONT VIEW
W
E
W
E
W
E
E
W
E
5"
127
W
W
E
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
Required floor support694 lb (315 kg )
A separate circuit breaker servicing only this appliance is
recommended.
Electrical supply115 V60 Hz327 W3 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter
assembly which must be mounted outside the unit.
The appliance must be connected only to a potable water
supply system.
To connect to water supply system (for appliances equipped
with ice maker) a ¼” waterline with accessible shut-off valve
must be supplied.
The solenoid connection on the appliance is ¾” diameter but
is metric threaded (NPT).
The system pressure must be between from 8 PSI to 75 PSI
(between 0.5 bar and 5 bar). Different pressures can cause
malfunctions or leaks in the water system.
For information on how to purchase the water filter, please
see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
Dimensions in parentheses are millimeters unless otherwise specified.
39bertazzoni.com
BUILT-IN FREEZER COLUMNS
18” Freezer Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130
Min.
a
25"
635
18"
457
a
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
40bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
BUILT-IN FREEZER COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
18” Freezer Column Panel Ready
Dimensions
REF18FCIPRL left hinge
REF18FCIPRR right hinge
22 1/4"
565
127
127
5"
2 3/4"
5"
82
615
17 15/16"
456
100°
17 15/16"
456
100°
24 1/4"
615
3 1/4"
40 3/4"
1036
*
82
**
3 1/4"
*
71 1/8"
80 3/4"
2050
+
1"(25)
70
19 7/8"
505
22 1/4"
565
80 3/4"
2050
+
1"(25)
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
40 3/4"
1036
24 1/4"
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension
** Width of 3/4” (19mm) Door Panel
For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
41bertazzoni.com
TOP VIEW
BUILT-IN FREEZER COLUMNS
18” Freezer Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For panel ready columns, do not exceed the maximum
weight of 75 pounds (34 kg) for door panel. Panel can have
thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
W
E
FRONT VIEW
W
E
W
E
E
W
E
5"
127
W
W
E
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
Required floor support694 lb (315 kg )
A separate circuit breaker servicing only this appliance is
recommended.
Electrical supply115 V60 Hz327 W3 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter
assembly which must be mounted outside the unit.
The appliance must be connected only to a potable water
supply system.
To connect to water supply system (for appliances equipped
with ice maker) a ¼” waterline with accessible shut-off valve
must be supplied.
The solenoid connection on the appliance is ¾” diameter but
is metric threaded (NPT).
The system pressure must be between from 8 PSI to 75 PSI
(between 0.5 bar and 5 bar). Different pressures can cause
malfunctions or leaks in the water system.
For information on how to purchase the water filter, please
see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
42bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
18” BUILT-IN FREEZER COLUMNS
18” Freezer Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25"
635
FRONT VIEW
a
a
b
18"
457
83 7/8"
2130
Min.
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
(b) Panel dimensions available on Built-in Food Preservation
Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
43bertazzoni.com
BUILT-IN WINE COLUMNS
24” - 18”
Panel Ready and
Panel Installed
44bertazzoni.com
45bertazzoni.com
BUILT-IN WINE COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
24” Wine Column Panel Installed
Dimensions
REF24WCPIXL left hinge
REF24WCPIXR right hinge
Handle choices
Professional Series: PROHKCOL
Master series: MASHKCOL
Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
23 5/8"
600
DOOR
WIDTH
77 3/4"
1974
5 3/4"
+ 1"(25)
146
77 3/4"
1974
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
23 5/8"
600
DOOR
WIDTH
3 1/2"
*
24 3/8"
89
46 5/8"
1185
620
24"
609
100°
24"
609
100°
24 3/8"
620
3 1/2"
46 5/8"
89
1185
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension
For detailed handle dimensions see page 71
46bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN WINE COLUMNS
24” Wine Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
E
EE
FRONT VIEW
EEE
5"
127
MAX
A separate circuit breaker servicing only this appliance is
recommended.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
Required floor support992 lb (450 kg )
Electrical supply115 V60 Hz152 W1.4 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
47bertazzoni.com
BUILT-IN WINE COLUMNS
24” Wine Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130
Min.
25"
635
24"
610
aa
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
48bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
BUILT-IN WINE COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
24” Wine Column Panel Ready
Dimensions
REF24WCPRL left hinge
REF24WCPRR right hinge
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
*
**
24 1/4"
4 1/4"
108
46 3/4"
1187
615
24"
609
100°
24"
609
100°
46 3/4"
1187
24 1/4"
615
4 1/4"
108
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension
** Width of 3/4” (19mm) Door Panel
For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
For custom panel dimensions and window cutout see page 69.
49bertazzoni.com
TOP VIEW
BUILT-IN WINE COLUMNS
24” Wine Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For panel ready columns, do not exceed the maximum
weight of 75 pounds (34 kg) for door panel. Panel can have
thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the
Multiple Installation Section (page ).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
E
EE
FRONT VIEW
EEE
5"
127
MAX
A separate circuit breaker servicing only this appliance is
recommended.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
50bertazzoni.com
Required floor support992 lb (450 kg )
Electrical supply115 V60 Hz152 W1.4 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN WINE COLUMNS
24” Wine Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25"
635
FRONT VIEW
aa
b
24"
610
83 7/8"
2130
Min.
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
(b) Panel dimensions available on Built-in Food Preservation
Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
51bertazzoni.com
BUILT-IN WINE COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
18” Wine Column Panel Installed
Dimensions
REF18WCPIXL left hinge
REF18WCPIXR right hinge
Handle choices
Professional Series: PROHKCOL
Master series: MASHKCOL
Heritage Series: HERHKCOL
22 1/4"
565
127
127
5"
2 3/4"
5"
63
24 3/8"
620
17 15/16"
456
100°
17 15/16"
456
100°
24 3/8"
620
2 1/2"
63
40 3/4"
1034
*
2 1/2"
*
77 3/4"
80 3/4"
2050
+
1"(25)
70
19 7/8"
505
22 1/4"
565
80 3/4"
2050
+
1"(25)
1974
5 3/4"
+ 1"(25)
146
77 3/4"
1974
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
17 5/8"
447
DOOR
WIDTH
40 3/4"
1034
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension
For detailed handle dimensions see page 71
17 5/8"
447
DOOR
WIDTH
Dimensions in parentheses are millimeters unless otherwise specified.
52bertazzoni.com
TOP VIEW
BUILT-IN WINE COLUMNS
18” Wine Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
E
EE
FRONT VIEW
EEE
5"
127
MAX
A separate circuit breaker servicing only this appliance is
recommended.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
53bertazzoni.com
Required floor support694 lb (315 kg )
Electrical supply115 V60 Hz152 W1.4 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN WINE COLUMNS
18” Wine Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130
Min.
a
25"
635
18"
457
a
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
54bertazzoni.com
BUILT-IN WINE COLUMNS
SIDE VIEW
FRONT VIEWTOP VIEW
SIDE VIEW
FRONT VIEWTOP VIEW
18” Wine Column Panel Ready
Dimensions
REF18WCPRL left hinge
REF18WCPRR right hinge
22 1/4"
565
127
127
5"
2 3/4"
5"
3 1/4"
*
71 1/8"
80 3/4"
2050
+
1"(25)
70
19 7/8"
505
22 1/4"
565
80 3/4"
2050
+
1"(25)
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
40 3/4"
1036
24 1/4"
615
17 15/16"
82
456
100°
17 15/16"
456
100°
24 1/4"
615
3 1/4"
82
40 3/4"
1036
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension
** Width of 3/4” (19mm) Door Panel
For detailed handle dimensions see page 71
55bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
For custom panel dimensions and window cutout see page 69.
TOP VIEW
BUILT-IN WINE COLUMNS
18” Wine Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.
For panel ready columns, do not exceed the maximum
weight of 75 pounds (34 kg) for door panel. Panel can have
thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
E
EE
FRONT VIEW
EEE
5"
127
MAX
A separate circuit breaker servicing only this appliance is
recommended.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
Required floor support694 lb (315 kg )
Electrical supply115 V60 Hz152 W1.4 Amp
Service15 Amp dedicated circuit
Power ConnectionNEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
56bertazzoni.com
BUILT-IN WINE COLUMNS
18” Wine Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25"
635
FRONT VIEW
a
a
b
18"
457
83 7/8"
2130
Min.
(a) Area to be left clear for the anti-tipping
brackets – 3”1/2x5” (82x127mm)
(b) Panel dimensions available on Built-in Food Preservation
Design Guide or Installation Manual
57bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
MULTIPLE INSTALLATIONS
58bertazzoni.com
TOP VIEW
MULTIPLE INSTALLATIONS
Multiple installations
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the
appliances and the adjacent cabinets, special side profiles are
factory-installed and covering frames are provided with the
product.
For panel ready columns, do not exceed the maximum
weight of 75 pounds (34 kg) for door panel. Panel can have
thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliances must be performed in
accordance with the provisions of applicable legislation.
Be sure that support of these appliances is perpendicular to
the front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting
the weight of all the appliances when in use. Please see any
single product installation manual for required floor support.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
E
EE
FRONT VIEW
EEE
5"
127
MAX
A separate 10 Amp circuit breaker servicing only these
appliances is recommended.
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter
assembly which must be mounted outside the unit.
The appliance must be connected only to a potable water
supply system.
To connect to water supply system (for appliances equipped
with ice maker) a ¼” waterline with accessible shut-off valve
must be supplied.
The solenoid connection on the appliance is ¾” diameter but
is metric threaded (NPT).
The system pressure must be between from 8 PSI to 75 PSI
(between 0.5 bar and 5 bar). Different pressures can cause
malfunctions or leaks in the water system.
For information on how to purchase the water filter, please
see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
60bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
(a) Spacers - Included with appliance
(b) All Freezer and Wine Columns are supplied with a vertical
connector trim for multiple columns installations. No addition
accessories are needed
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
c: Optional 42 inch bridge toe kick accessory is available.
For details see page 72
(a) Spacers - Included with appliance
(b) All Freezer and Wine Columns are supplied with a vertical
connector trim for multiple columns installations. No addition
accessories are needed
62bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
c: Optional 48 inch bridge toe kick accessory is available.
For details see page 72
(a) Spacers - Included with appliance
(b) All Freezer and Wine Columns are supplied with a vertical
connector trim for multiple columns installations. No addition
accessories are needed
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
(a) Spacers - Included with appliance
(b) All Freezer and Wine Columns are supplied with a vertical
connector trim for multiple columns installations. No addition
accessories are needed
64bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
(a) Spacers - Included with appliance
(b) All Freezer and Wine Columns are supplied with a vertical
connector trim for multiple columns installations. No addition
accessories are needed
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
(a) Spacers - Included with appliance
(b) All Freezer and Wine Columns are supplied with a vertical
connector trim for multiple columns installations. No addition
accessories are needed
66bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
(a) Spacers - Included with appliance
(b) All Freezer and Wine Columns are supplied with a vertical
connector trim for multiple columns installations. No addition
accessories are needed
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
(a) Spacers - Included with appliance
(b) All Freezer and Wine Columns are supplied with a vertical
connector trim for multiple columns installations. No addition
accessories are needed.
Optional 42 inch bridge toe kick accessory is available. For
details see page 72
68bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
b: depth includes kitchen cabinet front panel.
MULTIPLE INSTALLATIONS - CUSTOM DOOR PANEL
CUSTOM HANDLE MOUNTING AREA
REAR PANEL DRILLING
CUSTOM HANDLES MOUNTING AREA
DOOR WINDOW DIMENSIONS
CUSTOM HANDLES MOUNTING AREA
CUSTOM HANDLES MOUNTING AREA
DOOR WINDOW DIMENSIONS
Custom Door Panel
70 3/4"
1797
50"
1272
27 1/8"
690
REAR PANEL DRILLING
A
B B
6 1/2"
165
1/2"
13
4 3/8"
112
76"
1929
DOOR WINDOW
DIMENSIONS
5 1/2"
139
C
7 7/8"
200
61 7/8"
1572
5 1/2"
139
CUSTOM HANDLES
MOUNTING AREA
D D
CUSTOM HANDLE MOUNTING AREA
ON LEFT SWING DOOR
ON RIGHT SWING DOOR
1 3/8"
34
A 35 3/4” (908)29 3/4” (756)23 3/4” (604)17 3/4” (451)
PROFESSIONAL SERIES MASTER SERIES
PROHKCOLMASHKCOL
1 1/2"
37
2 1/8"
53
BERTAZZONI HANDLES
DRILLING ON RIGHT SWING DOOR
1 5/8"
42
35 3/8"
900
1 3/4"
45
HERITAGE SERIES
HERHKCOL
1 1/4"
31
2 3/8"
59
BERTAZZONI HANDLES
DRILLING ON LEFT SWING DOOR
1 5/8"
42
2 3/8"
59
35 3/8"
900
20 1/4"
514
HANDLE INSTALLATION ON CUSTOM PANELS
In case a custom panel is to be mounted on any of the models
listed below with Bertazzoni handles,it will be necessary to
install M5 x 0.8 mm brass tapping inserts in order to secure
the handle properly on the custom panel.
Recommended drill bit size to drill the pilot hole is 3/8”.
Suitable inserts can be ordered at www.encompassparts.com
20 1/4"
514
Part Number: 95631A100, contains n°4 M5 brass hardwood
inserts and 1 M5 installation bit.
Do not use a power tool to mount the inserts. Installation
of the inserts with improperly calibrated power tools risk
damaging the panels.
Dimensions in parentheses are millimeters unless otherwise specified.
71bertazzoni.com
MULTIPLE INSTALLATIONS - TOEKICK PANEL
Toekick Panel
Part number 901560Part number 901561
Installation of multiple column units with a continuous cabinet
toe kick are possible. Details are provided in the Bertazzoni
Columns installation manual