Bertazzoni REF24FCIPRL, REF36RCPIXL, REF24WCPIXL, REF36RCPIXR, REF36RCPRL Design Guide

...
BUILT-IN REFRIGERATOR COLUMNS BUILT-IN FREEZER COLUMNS BUILT-IN WINE COLUMNS
DESIGN GUIDE
1.0
BUILT-IN COLUMNS
These premium refrigerators, freezers and wine columns are masterpieces of design and technology. Their stylish appearance reflects close attention to detail and high-quality materials, inside and out. The stainless steel front and panel ready doors are mounted with state-of-the-art engineered lift-and­swing hinges that give the perception of a weightless range of motion. Versatile installation options make it possible to bring together elegant configurations of the refrigerator, freezer and wine columns in any desired width. All three columns work in harmony with handles and finishes available for every Series.
INDEX
INTRODUCTION 3
BUILT-IN REFRIGERATOR COLUMNS 4
36” Refrigerator Column Panel Installed 6
36” Refrigerator Column Panel Ready 9
30” Refrigerator Column Panel Installed 12
30” Refrigerator Column Panel Ready 15
24” Refrigerator Column Panel Installed 18
24” Refrigerator Column Panel Ready 21
BUILT-IN FREEZER COLUMNS 24
30” Freezer Column Panel Installed 26
30” Freezer Column Panel Ready 29
24” Freezer Column Panel Installed 32
24” Freezer Column Panel Ready 35
BUILT-IN WINE COLUMNS 44
24” Wine Column Panel Installed 46
24” Wine Column Panel Ready 49
18” Wine Column Panel Installed 52
18” Wine Column Panel Ready 55
MULTIPLE INSTALLATIONS 58
42” Double Configurations 61
48” Double Configurations 62
54” Double Configurations 63
60” Double Configurations 64
60” Triple Configurations 65
66” Triple Configurations 66
72” Triple Configurations 67
90” Triple Configurations 68
18” Freezer Column Panel Installed 38
18” Freezer Column Panel Ready 41
Custom Door Panel 69
Recommended Installations 70
Refrigeration Handles 71
Toekick Panel 72
3bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
36” - 30” - 24” Panel Ready and Panel Installed
4 bertazzoni.com
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
36” Refrigerator Column Panel Installed
Dimensions
REF36RCPIXL left hinge REF36RCPIXR right hinge
Handle choices
Professional Series: PROHKCOL Master series: MASHKCOL Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
35 5/8"
904
DOOR
WIDTH
77 3/4"
1974
5 3/4"
146
77 3/4"
1974
+ 1"(25)
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
35 5/8"
904
DOOR
WIDTH
5 1/2"
*
139
58 1/2"
1487
24 3/8"
620
35 15/16"
913
100°
35 15/16"
913
100°
24 3/8"
620
5 1/2"
58 1/2"
1487
139
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension For detailed handle dimensions see page 71
6 bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
TOP VIEW
36” Refrigerator Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product.
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
Required floor support 1532 lb (695 kg ) Electrical supply 115 V 60 Hz 218 W 2 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
7bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
36” Refrigerator Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130 Min.
25"
635
36" 914
a
a
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)
8 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
36” Refrigerator Column Panel Ready
Dimensions
REF36RCPRL left hinge REF36RCPRR right hinge
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
*
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
6 1/4"
158
58 5/8"
1489
24 1/4"
615
35 15/16"
913
100°
35 15/16"
913
100°
24 1/4"
615
6 1/4"
158
58 5/8"
1489
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension ** Width of 3/4” (19mm) Door Panel For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
9bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
TOP VIEW
36” Refrigerator Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
10 bertazzoni.com
Required floor support 1532 lb (695 kg )
Electrical supply 115 V 60 Hz 218 W 2 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN REFRIGERATOR COLUMNS
36” Refrigerator Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25"
635
FRONT VIEW
36" 914
a
a
b
83 7/8"
2130 Min.
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm) (b) Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
11bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
30” Refrigerator Column Panel Installed
Dimensions
REF30RCPIXL left hinge REF30RCPIXR right hinge
Handle choices
Professional Series: PROHKCOL Master series: MASHKCOL Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
29 5/8"
752
DOOR
WIDTH
77 3/4"
1974
5 3/4"
146
77 3/4"
1974
+ 1"(25)
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
29 5/8"
752
DOOR
WIDTH
4"
*
103
52 5/8"
1336
24 3/8"
620
29 15/16"
761
100°
29 15/16"
761
100°
24 3/8"
620
103
52 5/8"
4"
1336
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension For detailed handle dimensions see page 71
12 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product.
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
Required floor support 1257 lb (570 kg )
Electrical supply 115 V 60 Hz 218 W 2 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
13bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130 Min.
25" 635
30" 762
a
a
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)
14 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
30” Refrigerator Column Panel Ready
Dimensions
REF30RCPRL left hinge REF30RCPRR right hinge
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
*
5 1/4"
**
132
52 5/8"
1338
24 1/4"
615
29 15/16"
761
100°
29 15/16"
761
100°
24 1/4"
615
5 1/4"
52 5/8"
1338
132
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension ** Width of 3/4” (19mm) Door Panel For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
15bertazzoni.com
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
16 bertazzoni.com
Required floor support 1257 lb (570 kg )
Electrical supply 115 V 60 Hz 218 W 2 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN REFRIGERATOR COLUMNS
30” Refrigerator Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25" 635
FRONT VIEW
30"
762
a
a
b
83 7/8"
2130 Min.
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm) (b) Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
17bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
24” Refrigerator Column Panel Installed
Dimensions
REF24RCPIXL left hinge REF24RCPIXR right hinge
Handle choices
Professional Series: PROHKCOL Master series: MASHKCOL Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
23 5/8"
600
DOOR
WIDTH
77 3/4"
1974
5 3/4"
+ 1"(25)
146
77 3/4"
1974
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
23 5/8"
600
DOOR
WIDTH
3 1/2"
*
24 3/8"
89
46 5/8"
1185
620
24" 609
100°
24" 609
100°
24 3/8"
620
3 1/2"
46 5/8"
89
1185
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension For detailed handle dimensions see page 71
18 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
24” Refrigerator Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product.
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
Required floor support 992 lb (450 kg ) Electrical supply 115 V 60 Hz 163 W 1.5 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
19bertazzoni.com
BUILT-IN REFRIGERATOR COLUMNS
24” Refrigerator Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130 Min.
25" 635
24"
610
aa
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)
20 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
BUILT-IN REFRIGERATOR COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
24” Refrigerator Column Panel Ready
Dimensions
REF24RCPRL left hinge REF24RCPRR right hinge
22 1/4"
565
5"
5"
127
127
2 3/4"
2 3/4"
70
70
5"
5"
127
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
4 1/4"
*
46 3/4"
1187
108
24 1/4"
615
24" 609
100°
24"
609
100°
24 1/4"
615
4 1/4"
46 3/4"
1187
108
*
**
2 3/4"
2 3/4"
70
70
19 7/8"
505
* Maximum Overall Handle Dimension ** Width of 3/4” (19mm) Door Panel For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
21bertazzoni.com
TOP VIEW
BUILT-IN REFRIGERATOR COLUMNS
24” Refrigerator Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
22 bertazzoni.com
Required floor support 992 lb (450 kg ) Electrical supply 115 V 60 Hz 163 W 1.5 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN REFRIGERATOR COLUMNS
24” Refrigerator Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25" 635
FRONT VIEW
aa
b
24"
610
83 7/8"
2130 Min.
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm) (b) Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
23bertazzoni.com
BUILT-IN FREEZER COLUMNS
30” - 24” - 18” Panel Ready and Panel Installed
24 bertazzoni.com
25bertazzoni.com
BUILT-IN FREEZER COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
30” Freezer Column Panel Installed
Dimensions
REF30FCPIXL left hinge REF30FCPIXR right hinge
Handle choices
Professional Series: PROHKCOL Master series: MASHKCOL Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
29 5/8"
752
DOOR
WIDTH
77 3/4"
1974
5 3/4"
146
77 3/4"
1974
+ 1"(25)
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
29 5/8"
752
DOOR
WIDTH
4"
*
103
52 5/8"
1336
24 3/8"
620
29 15/16"
761
100°
29 15/16"
761
100°
24 3/8"
620
103
52 5/8"
4"
1336
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension For detailed handle dimensions see page 71
26 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN FREEZER COLUMNS
30” Freezer Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product.
For instructions of product combinations please see the Multiple Installation Section (page 58).
FRONT VIEW
W
E
W
E
W
E
E
W
E
5"
127
W
W
E
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
Required floor support 1257 lb (570 kg )
A separate circuit breaker servicing only this appliance is recommended.
Electrical supply 115 V 60 Hz 327 W 3 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter assembly which must be mounted outside the unit. The appliance must be connected only to a potable water supply system. To connect to water supply system (for appliances equipped with ice maker) a ¼” waterline with accessible shut-off valve must be supplied. The solenoid connection on the appliance is ¾” diameter but is metric threaded (NPT). The system pressure must be between from 8 PSI to 75 PSI (between 0.5 bar and 5 bar). Different pressures can cause malfunctions or leaks in the water system. For information on how to purchase the water filter, please see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
Dimensions in parentheses are millimeters unless otherwise specified.
27bertazzoni.com
BUILT-IN FREEZER COLUMNS
30” Freezer Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130 Min.
25" 635
30"
762
a
a
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)
28 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
BUILT-IN FREEZER COLUMNS
30” Freezer Column Panel Ready
Dimensions
REF30FCPRL left hinge REF30FCPRR right hinge
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
*
5 1/4"
**
132
52 5/8"
1338
24 1/4"
615
29 15/16"
761
100°
29 15/16"
761
100°
24 1/4"
615
5 1/4"
52 5/8"
1338
132
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension ** Width of 3/4” (19mm) Door Panel For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
29bertazzoni.com
BUILT-IN FREEZER COLUMNS
TOP VIEW
30” Freezer Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
W
E
FRONT VIEW
W
E
W
E
E
W
E
5"
127
W
W
E
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
Required floor support 1257 lb (570 kg )
A separate circuit breaker servicing only this appliance is recommended.
Electrical supply 115 V 60 Hz 327 W 3 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter assembly which must be mounted outside the unit. The appliance must be connected only to a potable water supply system. To connect to water supply system (for appliances equipped with ice maker) a ¼” waterline with accessible shut-off valve must be supplied. The solenoid connection on the appliance is ¾” diameter but is metric threaded (NPT). The system pressure must be between from 8 PSI to 75 PSI (between 0.5 bar and 5 bar). Different pressures can cause malfunctions or leaks in the water system. For information on how to purchase the water filter, please see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
30 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN FREEZER COLUMNS
30” Freezer Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25" 635
FRONT VIEW
30"
762
a
a
b
83 7/8"
2130 Min.
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm) (b) Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
31bertazzoni.com
BUILT-IN FREEZER COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
24” Freezer Column Panel Installed
Dimensions
REF24FCPIXL left hinge REF24FCPIXR right hinge
Handle choices
Professional Series: PROHKCOL Master series: MASHKCOL Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
23 5/8"
600
DOOR
WIDTH
77 3/4"
1974
5 3/4"
+ 1"(25)
146
77 3/4"
1974
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
23 5/8"
600
DOOR
WIDTH
3 1/2"
*
24 3/8"
89
46 5/8"
1185
620
24"
609
100°
24"
609
100°
24 3/8"
620
3 1/2"
46 5/8"
89
1185
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension For detailed handle dimensions see page 71
32 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN FREEZER COLUMNS
24” Freezer Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product..
For instructions of product combinations please see the Multiple Installation Section (page 58).
FRONT VIEW
W
E
W
E
W
E
E
W
E
5"
127
W
W
E
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
Required floor support 992 lb (450 kg )
A separate circuit breaker servicing only this appliance is recommended.
Electrical supply 115 V 60 Hz 327 W 3 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter assembly which must be mounted outside the unit. The appliance must be connected only to a potable water supply system. To connect to water supply system (for appliances equipped with ice maker) a ¼” waterline with accessible shut-off valve must be supplied. The solenoid connection on the appliance is ¾” diameter but is metric threaded (NPT). The system pressure must be between from 8 PSI to 75 PSI (between 0.5 bar and 5 bar). Different pressures can cause malfunctions or leaks in the water system. For information on how to purchase the water filter, please see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
Dimensions in parentheses are millimeters unless otherwise specified.
33bertazzoni.com
BUILT-IN FREEZER COLUMNS
24” Freezer Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130 Min.
25" 635
24"
610
aa
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)
34 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
BUILT-IN FREEZER COLUMNS
24” Freezer Column Panel Ready
Dimensions
REF24FCPRL left hinge REF24FCPRR right hinge
22 1/4"
565
5"
5"
127
127
2 3/4"
2 3/4"
70
70
5"
5"
127
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
4 1/4"
*
46 3/4"
1187
108
24 1/4"
615
24"
609
100°
24"
609
100°
24 1/4"
615
4 1/4"
46 3/4"
1187
108
*
**
2 3/4"
2 3/4"
70
70
19 7/8"
505
* Maximum Overall Handle Dimension ** Width of 3/4” (19mm) Door Panel For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
35bertazzoni.com
TOP VIEW
BUILT-IN FREEZER COLUMNS
24” Freezer Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
W
E
FRONT VIEW
W
E
W
E
E
W
E
5"
127
W
W
E
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
Required floor support 992 lb (450 kg )
A separate circuit breaker servicing only this appliance is recommended.
Electrical supply 115 V 60 Hz 327 W 3 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter assembly which must be mounted outside the unit. The appliance must be connected only to a potable water supply system. To connect to water supply system (for appliances equipped with ice maker) a ¼” waterline with accessible shut-off valve must be supplied. The solenoid connection on the appliance is ¾” diameter but is metric threaded (NPT). The system pressure must be between from 8 PSI to 75 PSI (between 0.5 bar and 5 bar). Different pressures can cause malfunctions or leaks in the water system. For information on how to purchase the water filter, please see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
36 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN FREEZER COLUMNS
24” Freezer Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25" 635
FRONT VIEW
aa
b
24"
610
83 7/8"
2130 Min.
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm) (b) Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
37bertazzoni.com
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
BUILT-IN FREEZER COLUMNS
18” Freezer Column Panel Installed
Dimensions
REF18FCIPIXL left hinge REF18FCIPIXR right hinge
Handle choices
Professional Series: PROHKCOL Master series: MASHKCOL Heritage Series: HERHKCOL
22 1/4"
565
17 5/8"
447
DOOR
WIDTH
*
2 1/2"
63
17 15/16"
456
127
127
5"
2 3/4"
5"
24 3/8"
100°
620
2 1/2"
63
40 3/4"
1034
*
77 3/4"
80 3/4"
2050
+
1"(25)
70
19 7/8"
505
22 1/4"
565
80 3/4"
2050
+
1"(25)
1974
5 3/4"
+ 1"(25)
146
77 3/4"
1974
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
17 5/8"
447
DOOR
WIDTH
40 3/4"
1034
24 3/8"
620
17 15/16"
456
100°
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension For detailed handle dimensions see page 71
38 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN FREEZER COLUMNS
18” Freezer Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product.
For instructions of product combinations please see the Multiple Installation Section (page 58).
FRONT VIEW
W
E
W
E
W
E
E
W
E
5"
127
W
W
E
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
Required floor support 694 lb (315 kg )
A separate circuit breaker servicing only this appliance is recommended.
Electrical supply 115 V 60 Hz 327 W 3 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter assembly which must be mounted outside the unit. The appliance must be connected only to a potable water supply system. To connect to water supply system (for appliances equipped with ice maker) a ¼” waterline with accessible shut-off valve must be supplied. The solenoid connection on the appliance is ¾” diameter but is metric threaded (NPT). The system pressure must be between from 8 PSI to 75 PSI (between 0.5 bar and 5 bar). Different pressures can cause malfunctions or leaks in the water system. For information on how to purchase the water filter, please see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
Dimensions in parentheses are millimeters unless otherwise specified.
39bertazzoni.com
BUILT-IN FREEZER COLUMNS
18” Freezer Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130 Min.
a
25" 635
18"
457
a
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)
40 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
BUILT-IN FREEZER COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
18” Freezer Column Panel Ready
Dimensions
REF18FCIPRL left hinge REF18FCIPRR right hinge
22 1/4"
565
127
127
5"
2 3/4"
5"
82
615
17 15/16"
456
100°
17 15/16"
456
100°
24 1/4"
615
3 1/4"
40 3/4"
1036
*
82
**
3 1/4"
*
71 1/8"
80 3/4"
2050
+
1"(25)
70
19 7/8"
505
22 1/4"
565
80 3/4"
2050
+
1"(25)
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
40 3/4"
1036
24 1/4"
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension ** Width of 3/4” (19mm) Door Panel For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified.
41bertazzoni.com
TOP VIEW
BUILT-IN FREEZER COLUMNS
18” Freezer Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
W
E
FRONT VIEW
W
E
W
E
E
W
E
5"
127
W
W
E
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
Required floor support 694 lb (315 kg )
A separate circuit breaker servicing only this appliance is recommended.
Electrical supply 115 V 60 Hz 327 W 3 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter assembly which must be mounted outside the unit. The appliance must be connected only to a potable water supply system. To connect to water supply system (for appliances equipped with ice maker) a ¼” waterline with accessible shut-off valve must be supplied. The solenoid connection on the appliance is ¾” diameter but is metric threaded (NPT). The system pressure must be between from 8 PSI to 75 PSI (between 0.5 bar and 5 bar). Different pressures can cause malfunctions or leaks in the water system. For information on how to purchase the water filter, please see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
42 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
18” BUILT-IN FREEZER COLUMNS
18” Freezer Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25" 635
FRONT VIEW
a
a
b
18"
457
83 7/8"
2130 Min.
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm) (b) Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
43bertazzoni.com
BUILT-IN WINE COLUMNS
24” - 18” Panel Ready and Panel Installed
44 bertazzoni.com
45bertazzoni.com
BUILT-IN WINE COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
24” Wine Column Panel Installed
Dimensions
REF24WCPIXL left hinge REF24WCPIXR right hinge
Handle choices
Professional Series: PROHKCOL Master series: MASHKCOL Heritage Series: HERHKCOL
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
23 5/8"
600
DOOR
WIDTH
77 3/4"
1974
5 3/4"
+ 1"(25)
146
77 3/4"
1974
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
23 5/8"
600
DOOR
WIDTH
3 1/2"
*
24 3/8"
89
46 5/8"
1185
620
24"
609
100°
24"
609
100°
24 3/8"
620
3 1/2"
46 5/8"
89
1185
*
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension For detailed handle dimensions see page 71
46 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
TOP VIEW
BUILT-IN WINE COLUMNS
24” Wine Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product.
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
Required floor support 992 lb (450 kg )
Electrical supply 115 V 60 Hz 152 W 1.4 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
47bertazzoni.com
BUILT-IN WINE COLUMNS
24” Wine Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130 Min.
25" 635
24"
610
aa
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)
48 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
BUILT-IN WINE COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
24” Wine Column Panel Ready
Dimensions
REF24WCPRL left hinge REF24WCPRR right hinge
22 1/4"
565
5"
127
2 3/4"
70
5"
127
80 3/4"
2050
+
1"(25)
80 3/4"
2050
+
1"(25)
19 7/8"
505
22 1/4"
565
71 1/8"
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
*
**
24 1/4"
4 1/4"
108
46 3/4"
1187
615
24"
609
100°
24"
609
100°
46 3/4"
1187
24 1/4"
615
4 1/4"
108
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension ** Width of 3/4” (19mm) Door Panel For detailed handle dimensions see page 71
Dimensions in parentheses are millimeters unless otherwise specified. For custom panel dimensions and window cutout see page 69.
49bertazzoni.com
TOP VIEW
BUILT-IN WINE COLUMNS
24” Wine Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the Multiple Installation Section (page ).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
50 bertazzoni.com
Required floor support 992 lb (450 kg )
Electrical supply 115 V 60 Hz 152 W 1.4 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN WINE COLUMNS
24” Wine Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25" 635
FRONT VIEW
aa
b
24"
610
83 7/8"
2130 Min.
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm) (b) Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
51bertazzoni.com
BUILT-IN WINE COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
18” Wine Column Panel Installed
Dimensions
REF18WCPIXL left hinge REF18WCPIXR right hinge
Handle choices
Professional Series: PROHKCOL Master series: MASHKCOL Heritage Series: HERHKCOL
22 1/4"
565
127
127
5"
2 3/4"
5"
63
24 3/8"
620
17 15/16"
456
100°
17 15/16"
456
100°
24 3/8"
620
2 1/2"
63
40 3/4"
1034
*
2 1/2"
*
77 3/4"
80 3/4"
2050
+
1"(25)
70
19 7/8"
505
22 1/4"
565
80 3/4"
2050
+
1"(25)
1974
5 3/4"
+ 1"(25)
146
77 3/4"
1974
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
17 5/8"
447 DOOR WIDTH
40 3/4"
1034
2 3/4"
70
19 7/8"
505
5 3/4"
146
+ 1"(25)
* Maximum Overall Handle Dimension For detailed handle dimensions see page 71
17 5/8"
447
DOOR
WIDTH
Dimensions in parentheses are millimeters unless otherwise specified.
52bertazzoni.com
TOP VIEW
BUILT-IN WINE COLUMNS
18” Wine Column Panel Installed
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product.
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
53 bertazzoni.com
Required floor support 694 lb (315 kg )
Electrical supply 115 V 60 Hz 152 W 1.4 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
BUILT-IN WINE COLUMNS
18” Wine Column Panel Installed
Flush installation
SIDE VIEW
TOP VIEW
b
FRONT VIEW
83 7/8"
2130 Min.
a
25" 635
18"
457
a
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
54bertazzoni.com
BUILT-IN WINE COLUMNS
SIDE VIEW
FRONT VIEW TOP VIEW
SIDE VIEW
FRONT VIEW TOP VIEW
18” Wine Column Panel Ready
Dimensions
REF18WCPRL left hinge REF18WCPRR right hinge
22 1/4"
565
127
127
5"
2 3/4"
5"
3 1/4"
*
71 1/8"
80 3/4"
2050
+
1"(25)
70
19 7/8"
505
22 1/4"
565
80 3/4"
2050
+
1"(25)
1808
71 1/8"
1808
83 1/2"
2120
+
1"(25)
83 1/2"
2120
+
1"(25)
**
40 3/4"
1036
24 1/4"
615
17 15/16"
82
456
100°
17 15/16"
456
100°
24 1/4"
615
3 1/4"
82
40 3/4"
1036
*
**
2 3/4"
70
19 7/8"
505
* Maximum Overall Handle Dimension ** Width of 3/4” (19mm) Door Panel For detailed handle dimensions see page 71
55 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. For custom panel dimensions and window cutout see page 69.
TOP VIEW
BUILT-IN WINE COLUMNS
18” Wine Column Panel Ready
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factory­installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance with the provisions of applicable legislation. Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is recommended.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
Required floor support 694 lb (315 kg )
Electrical supply 115 V 60 Hz 152 W 1.4 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
Dimensions in parentheses are millimeters unless otherwise specified.
56bertazzoni.com
BUILT-IN WINE COLUMNS
18” Wine Column Panel Ready
Flush installation
SIDE VIEW
TOP VIEW
b
25" 635
FRONT VIEW
a
a
b
18"
457
83 7/8"
2130 Min.
(a) Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm) (b) Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual
57 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
MULTIPLE INSTALLATIONS
58 bertazzoni.com
TOP VIEW
MULTIPLE INSTALLATIONS
Multiple installations
Installation requirements
INSTALLATION
All Bertazzoni columns can be installed in a standard 25” depth cutout. Finish the edges of the opening because they may be visible when the door is open. For a built-in installation, to cover gaps between the appliances and the adjacent cabinets, special side profiles are factory-installed and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliances must be performed in accordance with the provisions of applicable legislation. Be sure that support of these appliances is perpendicular to the front facing of the wall or cabinet before you perform the installation. The floor must be flat and must be capable of supporting the weight of all the appliances when in use. Please see any single product installation manual for required floor support.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed. Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations. Placement within the opening may require additional cabinet depth.
E
E E
FRONT VIEW
EE E
5"
127
MAX
A separate 10 Amp circuit breaker servicing only these appliances is recommended.
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter assembly which must be mounted outside the unit. The appliance must be connected only to a potable water supply system. To connect to water supply system (for appliances equipped with ice maker) a ¼” waterline with accessible shut-off valve must be supplied. The solenoid connection on the appliance is ¾” diameter but is metric threaded (NPT). The system pressure must be between from 8 PSI to 75 PSI (between 0.5 bar and 5 bar). Different pressures can cause malfunctions or leaks in the water system. For information on how to purchase the water filter, please see Use and Maintenance Manual.
For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.
60 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified.
MULTIPLE INSTALLATIONS - 42” DOUBLE CONFIGURATIONS
42” Double Configurations
Flush installation
POSSIBLE COMBINATIONS
REF24RCPIX(L/R) REF18FCPIX(L/R)
REF24RCPR(L/R) REF18FCPR(L/R)
REF24RCPIX(L/R) REF18WCPIX(L/R)
REF24RCPR(L/R) REF18FCPR(L/R)
25"
635
bc
TOP VIEW
FRONT VIEW
83 7/8"
2130 Min.
42"
1067
a
(a) Spacers - Included with appliance (b) All Freezer and Wine Columns are supplied with a vertical connector trim for multiple columns installations. No addition accessories are needed
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel. c: Optional 42 inch bridge toe kick accessory is available. For details see page 72
61bertazzoni.com
MULTIPLE INSTALLATIONS - 48” DOUBLE CONFIGURATIONS
48” Double Configurations
Flush installation
POSSIBLE COMBINATIONS
REF30RCPIX(L/R) REF18FCPIX(L/R)
REF30RCPR(L/R) REF18FCPR(L/R)
REF30RCPIX(L/R) REF18WCPIX(L/R)
REF30RCPR(L/R) REF18WCPR(L/R)
REF24RCPIX(L/R) REF24FCPIX(L/R)
REF24RCPR(L/R) REF24FCPR(L/R)
25"
635
b
c
TOP VIEW
FRONT VIEW
a
48"
1219
83 7/8"
2130 Min.
REF24RCPIX(L/R) REF24WCPIX(L/R)
REF24RCPR(L/R) REF24WCPR(L/R)
(a) Spacers - Included with appliance (b) All Freezer and Wine Columns are supplied with a vertical connector trim for multiple columns installations. No addition accessories are needed
62 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel. c: Optional 48 inch bridge toe kick accessory is available. For details see page 72
MULTIPLE INSTALLATIONS - 54” DOUBLE CONFIGURATIONS
54” Double Configurations
Flush installation
POSSIBLE COMBINATIONS
REF30RCPIX(L/R) REF24FCPIX(L/R)
REF30RCPR(L/R) REF24FCPR(L/R)
REF30RCPIX(L/R) REF18WCPIX(L/R)
REF30RCPR(L/R) REF18WCPR(L/R)
REF36RCPIX(L/R) REF18FCPIX(L/R)
REF36RCPR(L/R) REF18FCPR(L/R)
TOP VIEW
FRONT VIEW
83 7/8"
2130 Min.
25"
635
b
a
54"
1372
REF36RCPIX(L/R) REF18WCPIX(L/R)
REF36RCPR(L/R) REF18WCPR(L/R)
(a) Spacers - Included with appliance (b) All Freezer and Wine Columns are supplied with a vertical connector trim for multiple columns installations. No addition accessories are needed
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
63bertazzoni.com
MULTIPLE INSTALLATIONS - 60” DOUBLE CONFIGURATIONS
60” Double Configurations
Flush installation
POSSIBLE COMBINATIONS
REF30RCPIX(L/R) REF30FCPIX(L/R)
REF30RCPR(L/R) REF30FCPR(L/R)
REF36RCPIX(L/R) REF24WCPIX(L/R)
REF36RCPR(L/R) REF24WCPR(L/R)
REF36RCPIX(L/R) REF24FCPIX(L/R)
REF36RCPR(L/R) REF24FCPR(L/R)
83 7/8"
2130
Min.
TOP VIEW
b
25"
635
FRONT VIEW
60"
1524
a
(a) Spacers - Included with appliance (b) All Freezer and Wine Columns are supplied with a vertical connector trim for multiple columns installations. No addition accessories are needed
64 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
MULTIPLE INSTALLATIONS - 60” TRIPLE CONFIGURATIONS
(
60” Triple Configurations
Flush installation
POSSIBLE COMBINATIONS
REF24RCPIX(L/R) REF18FCPIX(L/R) REF18WCPIX(L/R)
REF24RCPR(L/R) REF18FCPR(L/R) REF18WCPR
L/R)
83 7/8"
2130 Min.
TOP VIEW
b
25"
635
FRONT VIEW
60"
1524
a
(a) Spacers - Included with appliance (b) All Freezer and Wine Columns are supplied with a vertical connector trim for multiple columns installations. No addition accessories are needed
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
65bertazzoni.com
MULTIPLE INSTALLATIONS - 66” TRIPLE CONFIGURATIONS
(
66” Triple Configurations
Flush installation
POSSIBLE COMBINATIONS
REF30RCPIX(L/R) REF18FCPIX(L/R) REF18WCPIX(L/R)
REF30RCPR(L/R) REF18FCPR(L/R) REF18WCPR
L/R)
83 7/8"
2130
Min.
25" 635
b
TOP VIEW
FRONT VIEW
66"
1676
a
(a) Spacers - Included with appliance (b) All Freezer and Wine Columns are supplied with a vertical connector trim for multiple columns installations. No addition accessories are needed
66 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
MULTIPLE INSTALLATIONS - 72” TRIPLE CONFIGURATIONS
(
72” Triple Configurations
Flush installation
POSSIBLE COMBINATIONS
REF24RCPIX(L/R) REF24FCPIX(L/R) REF24WCPIX(L/R)
REF24RCPR(L/R) REF24FCPR(L/R) REF24WCPR
L/R)
83 7/8"
2130 Min.
25" 635
b
TOP VIEW
FRONT VIEW
72"
1829
a
(a) Spacers - Included with appliance (b) All Freezer and Wine Columns are supplied with a vertical connector trim for multiple columns installations. No addition accessories are needed
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
67bertazzoni.com
MULTIPLE INSTALLATIONS - 90” TRIPLE CONFIGURATIONS
(
90” Triple Configurations
Flush installation
POSSIBLE COMBINATIONS
REF36RCPIX(L/R) REF30FCPIX(L/R) REF24WCPIX(L/R)
REF36RCPR(L/R) REF30FCPR(L/R) REF24WCPR
L/R)
b
TOP VIEW
25"
635
b
FRONT VIEW
a
90"
2286
83 7/8"
2130 Min.
(a) Spacers - Included with appliance (b) All Freezer and Wine Columns are supplied with a vertical connector trim for multiple columns installations. No addition accessories are needed. Optional 42 inch bridge toe kick accessory is available. For details see page 72
68 bertazzoni.com
Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.
MULTIPLE INSTALLATIONS - CUSTOM DOOR PANEL
CUSTOM HANDLE MOUNTING AREA
REAR PANEL DRILLING
CUSTOM HANDLES MOUNTING AREA
DOOR WINDOW DIMENSIONS
CUSTOM HANDLES MOUNTING AREA
CUSTOM HANDLES MOUNTING AREA
DOOR WINDOW DIMENSIONS
Custom Door Panel
70 3/4"
1797
50"
1272
27 1/8"
690
REAR PANEL DRILLING
A
B B
6 1/2"
165
1/2"
13
4 3/8"
112
76"
1929
DOOR WINDOW DIMENSIONS
5 1/2"
139
C
7 7/8"
200
61 7/8"
1572
5 1/2"
139
CUSTOM HANDLES MOUNTING AREA
D D
CUSTOM HANDLE MOUNTING AREA
ON LEFT SWING DOOR
ON RIGHT SWING DOOR
1 3/8"
34
A 35 3/4” (908) 29 3/4” (756) 23 3/4” (604) 17 3/4” (451)
B 16 1/2” (418) 13 1/2” (343) 10 7/8” (275) 7 7/8” (200)
C 12 7/8” (327) 6 7/8” (177)
D 7 1/8” (182) 6” (152) 4 3/4” (121) 3 5/8” (92)
1 3/8"
34
36” 30” 24” 18”
Dimensions in parentheses are millimeters unless otherwise specified.
69bertazzoni.com
MULTIPLE INSTALLATIONS - RECOMMENDED INSTALLATIONS
Recommended Installations
RECOMMENDED INSTALLATIONS
NOT RECOMMENDED INSTALLATIONS
70 bertazzoni.com
MULTIPLE INSTALLATIONS - REFRIGERATION HANDLES
Refrigeration Handles
PROFESSIONAL SERIES MASTER SERIES PROHKCOL MASHKCOL
1 1/2"
37
2 1/8"
53
BERTAZZONI HANDLES DRILLING ON RIGHT SWING DOOR
1 5/8"
42
35 3/8"
900
1 3/4"
45
HERITAGE SERIES HERHKCOL
1 1/4"
31
2 3/8"
59
BERTAZZONI HANDLES DRILLING ON LEFT SWING DOOR
1 5/8"
42
2 3/8"
59
35 3/8"
900
20 1/4"
514
HANDLE INSTALLATION ON CUSTOM PANELS
In case a custom panel is to be mounted on any of the models listed below with Bertazzoni handles,it will be necessary to install M5 x 0.8 mm brass tapping inserts in order to secure the handle properly on the custom panel. Recommended drill bit size to drill the pilot hole is 3/8”. Suitable inserts can be ordered at www.encompassparts.com
20 1/4"
514
Part Number: 95631A100, contains n°4 M5 brass hardwood inserts and 1 M5 installation bit. Do not use a power tool to mount the inserts. Installation of the inserts with improperly calibrated power tools risk damaging the panels.
Dimensions in parentheses are millimeters unless otherwise specified.
71bertazzoni.com
MULTIPLE INSTALLATIONS - TOEKICK PANEL
Toekick Panel
Part number 901560 Part number 901561
Installation of multiple column units with a continuous cabinet toe kick are possible. Details are provided in the Bertazzoni Columns installation manual
72 bertazzoni.com
BERTAZZONI.COM
TO COOK BEAUTIFULLY
Loading...