Berbel BLB 60 FL, BLB 90 FLE, BLB 90 FL, BLB 60 FLE Operating And Installation Instructions

Page 1
berbel-
Fan Module BLB
Operating and installation instructions for the models:
BLB 60 FL / BLB 90 FL
BLB 60 FLE / BLB 90 FLE
01/2011 (updated 08/2015)
English translation of the German original manual
Page 2
This manual helps you to use and install our product
as intended, safely and economically.
In the following text, our product the berbel-
Lüfterbaustein BLB 60 FL, BLB 90 FL, BLB 60 FLE
and BLB 90 FLE will be referred to as the 'device' in
short.
This manual is intended for the following persons:
§ Persons using the device
§ Persons cleaning the device
§ Persons disposing of the device
§ Persons installing the device
Everyone in these groups of people must have read
and understood the contents of this manual. Other
persons should not be permitted to use the device
unsupervised (children or persons with impaired
mental or sensory abilities for example).
You can increase the reliability and service life of the
equipment and minimise risks by following the
instructions in this manual.
Layout features in the text
The text in this manual is laid out in a standard way.
This helps you to easily distinguish between the
various elements:
Normal text
Cross references
§ Lists or
Ø Action steps.
Tips contain special information to help you
use the device economically.
Design features in the illustrations
The illustrations consist of greyscale representations.
If elements are referred to in the text or in the legends, these elements are marked with a position number 
Movements or actions to be carried out are indicated
by motion or direction arrows. If there are several steps
to be performed in sequence shown on one illustration,
the order is indicated by numbers (1., 2., etc.):
Page 3
3
Most functions (operation, maintenance) and the assembly of all devices which are described in these
instructions are identical.
All the following descriptions and illustrations are therefore valid for the berbel- fan fodule
BLB 60 FL, BLB 60 FLE, BLB 90 FL and BLB 90 FLE.
The few exceptions to this are referred to directly in the text at the appropriate places.
The berbel-Lüfterbaustein BLB 90 FL is mainly shown in the illustrations.
Contents
Safety.....................................................................................................................................................................5
Proper and intended use............................................................................................................................................5
Ban on independent conversions and modifications..................................................................................................5
Layout of hazard notices.............................................................................................................................................5
Layout of notices regarding damage to property or the environment.........................................................................5
General safety instructions......................................................................................................................................6
Basic safety instructions.............................................................................................................................................6
Safety instructions for the user................................................................................................................................6
Safety instructions for the installer...........................................................................................................................7
Operating instructions...........................................................................................................................................10
Description for the user.........................................................................................................................................10
Possible operating modes........................................................................................................................................10
Device view with closed lower section......................................................................................................................11
Device view with opened lower section....................................................................................................................12
Operating.............................................................................................................................................................13
Turning on the ventilation function............................................................................................................................13
Changing the power level.........................................................................................................................................14
Turning off the ventilation function............................................................................................................................15
Turning the lighting on and off..................................................................................................................................16
Cleaning...............................................................................................................................................................17
Cleaning intervals.....................................................................................................................................................17
Cleaning with normal soiling.....................................................................................................................................17
Cleaning when heavily soiled...................................................................................................................................18
Cleaning the surfaces...............................................................................................................................................20
Cleaning the rotary knob...........................................................................................................................................21
Maintenance.........................................................................................................................................................22
Maintaining the device..............................................................................................................................................22
Changing the bulbs...................................................................................................................................................22
Changing the filter filling (hybrid and recirculated air filters).....................................................................................22
Troubleshooting....................................................................................................................................................25
Page 4
4
Installation instructions..........................................................................................................................................27
Description for the installer....................................................................................................................................27
Possible operating modes........................................................................................................................................27
Information about extracted air mode.......................................................................................................................28
Basics about the device............................................................................................................................................33
Device view from above............................................................................................................................................34
Device view from underneath with a closed lower section.......................................................................................35
Device view from underneath with opened lower section........................................................................................36
Preparation for installation....................................................................................................................................37
Qualifications of personnel.......................................................................................................................................37
Prerequisites for the mechanical end assembly.......................................................................................................37
Brief overview of the installation...............................................................................................................................38
Tools and equipment needed...................................................................................................................................40
Unpacking.................................................................................................................................................................40
Check the delivery....................................................................................................................................................41
Remove the parts for installation..............................................................................................................................42
Remove the lower section........................................................................................................................................43
Remove the capillary trap.........................................................................................................................................43
Remove the bracket..................................................................................................................................................44
Create the installation cut-out...................................................................................................................................44
Installing the device..............................................................................................................................................45
Safety distances are observed.................................................................................................................................46
Fitting the bracket BLB 60 FL(E)..............................................................................................................................46
Fitting the bracket BLB 90 FL(E)..............................................................................................................................47
Hang the device........................................................................................................................................................48
Align the device horizontally.....................................................................................................................................49
Secure the lock.........................................................................................................................................................49
Only BLB 60 FLE / BLB 90 FLE: Connect the connection cable of the fan.............................................................50
Connecting the wall box and the window contact switch contacts...........................................................................51
Creating the exhaust air connection.........................................................................................................................54
Install the other parts................................................................................................................................................57
Connect the power supply........................................................................................................................................58
Initial cleaning.......................................................................................................................................................58
Cleaning the surfaces...............................................................................................................................................58
Cleaning the controls................................................................................................................................................58
Disassembling the device.....................................................................................................................................59
Disposal...............................................................................................................................................................60
Disposal of the packaging.........................................................................................................................................60
Gerät Disposal ..........................................................................................................................................................60
Technical specifications........................................................................................................................................61
Volume flow for operation with an external fan.........................................................................................................61
Fan module BLB 60..................................................................................................................................................61
Contact.................................................................................................................................................................62
Contacting the customer services of the manufacturer............................................................................................62
Page 5
General safety instructions
Safety 5
Safety
Proper and intended use
The device can be used to extract cooking vapours
when cooking in private households.
Ø Only use this device in private kitchens.
This device has been exclusively intended for this
purpose and must only be put to this use. The device
may only be used in the manner described in this
manual.
Any other use of or modification to the device is
considered improper usage and may lead to damage.
The manufacturer is not liable for damages which
occur as a result of improper use, incorrect installation
or incorrect operation. This device is not intended for
commercial use.
Ban on independent conversions and modifications
§ Do not undertake and independent modifications of
or conversions to the device. Conversions or
modifications without the approval of berbel
Ablufttechnik GmbH are not permitted.
§ Never bridge or bypass the protective equipment
found on the device.
Layout of hazard notices
In this manual you will find the following categories of
hazard notices:
DANGER
Notices with the word DANGER warn
of a hazardous situation which will
result in death or serious injuries.
WARNING
Notices with the word WARNING warn
of a hazardous situation which can
lead to death or serious injuries.
CAUTION
Notices with the word CAUTION warn
of a situation that can lead to minor or
moderate injuries.
Layout of notices regarding damage to property or the environment
ATTENTION
These notices warn of a situation that
can lead to damage to property or to
the environment.
Page 6
Safety
6 Safety
General safety instructions
Ø Read this chapter carefully before installing, using,
or cleaning the device.
Specific, important safety instructions can be
found:
- in the "Safety instructions for the installer" for
persons installing or removing the device.
- in the "Safety instructions for the user" for
persons operating or cleaning the device. Read
these chapters carefully to avoid danger, injuries
and damage.
Ø Follow the safety and danger notices during all
activities on the device.
Ø Make sure that only persons who have read and
understood the contents of this manual use the
device.
Children or other persons with impaired mental or
sensory abilities should not be permitted to use the
device unsupervised.
Ø Include this manual if you pass the device on.
Basic safety instructions
This section contains the basic safety instructions for
handling the device. Additional safety instructions,
concerning the particular actions and processes, can
be found in the respective chapters.
§ Take note of all safety instructions and danger
notices in this manual.
§ Check the device and all its parts for visible
damage. In the event of damage, contact your
dealer or berbel customer service. You may only
use the device if it is in perfect working order.
§ Always let qualified specialist personnel conduct
maintenance or repair work. Otherwise, you
endanger yourself and others.
§ Only use this device in private kitchens.
§ Use this device only when the capillary trap is fitted
and with the lower section closed.
§ Make sure that there are no unsupervised children
in the vicinity of the device and that they do not play
with it.
Safety instructions for the user
Read this chapter carefully before using or cleaning the
device.
Ø Follow the warning notices during all activities on
the device.
Avoiding dangers caused by electric shock
§ Do not use the device with a damaged electrical
connection cable.
§ The mains plug must be easily accessible so that
you can quickly and easily isolate the device from
the mains supply in the event of an emergency. If
the mains plug is inaccessible following installation,
an all-pole isolating device with a contact gap of at
least 3 mm must be installed and accessible.
§ In the event of a malfunction, disconnect the device
immediately from the mains. Only allow trained
specialist personnel to repair the device.
§ Do not kink or crush the mains cable.
§ Only use the device if it is connected and fused in
accordance with the technical data.
§ Never open the housing of the device's fan unit.
§ Keep the device dry.
§ Avoid exposing the device to dripping or splashing
water or other fluids.
§ Do not place any objects filled with fluids, like vases
for example, above the device or on the device.
If fluid does enter the device:
- Immediately shut off the power supply
by removing the fuse, for example. -
Make sure that the power supply
of the device cannot be unintentionally
reconnected. Perhaps by designating a person to
prevent the fuse being switched on again.
- Allow the device to dry.
- Have the device checked and repaired by trained,
specialist personnel prior to using the device
again.
Page 7
Safety instructions for the
installer
Safety 7
Avoiding the risk of explosion
§ Do not operate the device in an environment with a
risk of explosion.
Avoiding the risk of fire
§ Do not use the device during a fire or when there is
an imminent danger of fire (e.g. a smell of gas) in
the household.
§ Make sure that the hob has cooled down before you
cover it.
A dirty device can cause fire hazards.
§ Keep the device in perfect working order and check
it regularly.
§ Regularly remove any grease residues which are
present. Grease residues pose a fire hazard.
Overheated oil and a naked flame can cause fire
hazards.
§ Do not flambé underneath the device. Naked flames
can cause damage to neighbouring cabinets for
example.
§ Never deep-fry food unattended under the device.
Overheated oil can spontaneously ignite.
When operating over a gas stove or a gas unit:
§ Make sure that the gas flame is kept low. Naked
flames should not appear beyond the edge of the
pan base.
In recirculated air mode:
§ A covered or sealed ventilation outlet can cause a
fire hazard. Do not place any objects like lids or
plates for example on or in front of the ventilation
slits of the device. In the case of recirculated air
devices, out flowing air must be able to escape
back into the kitchen through the ventilation slits
without impediment.
§ No objects should be mounted in the area of the
ventilation slits of the device which could impede
the air flow. Make sure that out flowing air is able to
flow into the kitchen without impediment.
Operating over a solid-fuel burning fireplace:
The device may only be used over a fireplace for solid
fuels (e.g. a coal-burning stove) if:
§ the fireplace has a sealed cover which cannot be
removed. Otherwise there is an increased fire risk
due to flying sparks.
§ the legal and country-specific regulations are
observed.
Avoiding risks of injury
§ To prevent the risk of falling, use a stable step-
ladder for all work on the device, for example
replacing the filter and cleaning the device.
§ To prevent the risk of injury by falling parts, do not
place any objects on the device.
Avoiding the risk of suffocation
If the device and an open fireplace which uses air from
the room for its oxygen supply, gases or waste gases
may be drawn into the room.
§ Ensure there is an adequate supply of fresh air into
the dwelling.
§ Never let children play with the foil or other parts of
the packaging.
§ Store the film or other parts of the packaging in a
location which is inaccessible to children.
§ Make sure that all of the permits required for
operation in your country have been obtained (e.g.
the master chimney sweep).
§ Make sure that all standards and guidelines for
operating the device in your country are observed.
Avoiding environmental damage
§ Dispose of the device and its accessories in
accordance with the legal regulations.
Safety instructions for the installer
The safety instructions concerning the device's
installation can be found in this section. Additional
safety instructions, concerning the particular actions
Page 8
Safety
8 Safety
and processes, can be found in the respective
chapters.
Ø Read this chapter carefully before installing the
device.
Ø Follow all the safety and danger notices during all
activities on the device.
Ø Only install this device in private kitchens.
Ø Make sure that the power cable is free from voltage
during installation.
Ø Check the device and all its parts for visible
damage. In the event of damage, contact your
dealer or berbel customer service. You may only
install the device if it is in perfect working order.
Ø Mount the device using the supplied brackets only
on load bearing building parts (solid construction).
Ø Use appropriate fastening mechanisms for any
other sort of installation. If in doubt, please check
with the dealer. Otherwise, you endanger yourself
and others.
Ø Always let qualified specialist personnel conduct
repair work. Otherwise, you endanger yourself and
others.
Avoiding dangers caused by electric shock
§ Only let trained, qualified electricians work on the
power supply.
The electricians must have the following knowledge
and abilities as a minimum:
§ Basic knowledge of electrical engineering
§ Knowledge of country-specific regulations
and standards (e.g. in Germany,
DIN 57100/VDE 0100, part 701)
§ Knowledge of the applicable
safety regulations
§ Knowledge of the applicable legal
regulations for gas installations (e.g.
in Germany the technical rules for gas
installations TRGI).
§ Only install the device if it is connected and fused in
accordance with the technical data.
§ Do not kink or crush the mains cable.
§ Do not use the device with a damaged electrical
connection cable.
§ In the event of a malfunction, disconnect the device
immediately from the mains.
§ The mains plug must be easily accessible so that
you can quickly and easily isolate the device from
the mains supply in the event of an emergency. If
the mains plug is inaccessible following installation,
an all-pole isolating device with a contact gap of at
least 3 mm must be installed and accessible.
§ If the device is moved from a cold environment into
a hot one, condensation may form inside the
device. In this case wait about 2 to 3 hours before
bringing the device into service.
§ Avoid exposing the device to liquids.
§ Keep the device dry.
Avoiding the risk of explosion
§ Do not install the device in an environment with a
risk of explosion.
Avoiding the risk of fire
§ Make sure that the hob has cooled down before you
cover it.
In recirculated air mode:
§ A covered or sealed ventilation outlet can cause a
fire hazard. In the case of recirculated air devices,
out flowing air must be able to escape back into the
kitchen through the ventilation slits without
impediment.
§ You may not install any objects that could impede
the airflow. Make sure that out flowing air is able to
flow into the kitchen without impediment.
Page 9
Safety instructions for the
installer
Safety 9
The device may only be installed over a fireplace for
solid fuels (e.g. a coal-burning stove) if:
§ the fireplace has a sealed cover which cannot be
removed. Otherwise there is an increased fire risk
due to flying sparks.
§ the legal and country-specific regulations are
observed.
Avoiding risks of injury
§ To prevent the risk of falling, use a stable
stepladder for all work on the device, for example
replacing the filter, installing and cleaning the
device.
§ To prevent the risk of injury by falling parts, do not
place any objects on the device.
§ To prevent injury from falling parts, only use
suitable fastening materials.
§ To prevent cuts from broken glass, use suitable
protective gloves.
Avoiding the risk of suffocation
If the device and an open fireplace which uses air from
the room for its oxygen supply, gases or waste gases
may be drawn into the room.
§ Make sure that all of the permits required for
operation in your country have been obtained (e.g.
the master chimney sweep).
§ Make sure that all standards and guidelines for
operating the device in your country are observed.
§ Ensure there is an adequate supply of fresh air into
the dwelling.
§ Never let children play with the foil or other parts of
the packaging.
§ Store the film or other parts of the packaging in a
location which is inaccessible to children.
Minimising the danger of collapse
In extracted air mode:
§ The wall breakthrough that is needed must be
created by technically qualified persons. Wall
breakthroughs affect the building's structural
stability. Improperly made wall breakthroughs could
result in the building collapsing.
Page 10
Operating instructions
10 Operating instructions
Operating instructions
Description for the user
The following illustrations show the way the
possible operating modes work. The devices
used are shown as symbols. The illustrations are
meant to serve as a guide. The illustrated device
shapes may differ from your device.
With this device you can suck in and clean cooking
vapours. Cleaning the room air that is sucked in is
done in several cleaning stages. Dirt particles, such as
fat and oil particles, are trapped on the upper and lower
sections.
Possible operating modes
The device can work in different operating modes:
§ Recirculated air mode
§ Extracted air mode
§ Hybrid mode
The individual operating modes are described in the
next sections.
Extracted air mode
The device draws room air in and filters dirt particles
out of the air. The cleaned air is discharged outside.
Recirculated air mode
The filter filling must be replaced at regular
intervals in recirculated air mode.
The device draws room air in and filters dirt particles
out of the air.
The filter filling in the recirculated air filter neutralises
any smelly odours present. The odour-free, cleaned
room air is fed back into the room.
Hybrid mode
The filter filling must be replaced regular intervals
in hybrid mode.
The device draws room air in and filters dirt particles
out of the air. Part of the cleaned air is discharged
outside. The filter filling in the hybrid filter neutralises
the existing odour components of the remaining air
sucked in from the room. The odourless, cleaned room
air is then fed back into the room.
Page 11
Description for the
user
Operating instructions 11
Device view with closed lower section
fan module BLB 90 FL Rotary knob (on and off switch)
Lower section Illumination
All the following descriptions and illustrations are therefore valid for the berbel- fan module
BLB 60 FL, BLB 60 FLE, BLB 90 FL and BLB 90 FLE.
The berbel- fan module BLB 90 FL is mainly shown in the illustrations.
Page 12
Description for the user
12 Operating instructions
Device view with opened lower section
fan module BLB 90 FL Capillary trap
Upper section Lower section
All the following descriptions and illustrations are therefore valid for the berbel- fan module
BLB 60 FL, BLB 60 FLE, BLB 90 FL and BLB 90 FLE.
The berbel- fan module BLB 90 FL is mainly shown in the illustrations.
Page 13
Operating
Operating instructions 13
Operating
WARNING
Suffocation risk due to low oxygen
levels when operating the device.
Ø Ensure there is an adequate supply
of fresh air into the dwelling.
Ø Make sure that the device is
connected to a window contact
switch for safe operation.
Ø Make sure that all country-specific
statutory regulations are observed
(e.g. in Germany the requirements of
the federal state's fire regulations).
The functions of the device are controlled using the
control panel. This device is fitted with a rotary knob
(ThinCoder) for operation.
The rotary knob is located on the bottom side of the
device.
You can find out how to operate all the device functions
using this rotary knob in the following sections.
Turning on the ventilation function
WARNING
Explosion risk and fire hazard from gas
or explosive or flammable gas mixtures
in the kitchen when operating electrical
equipment.
If you smell gas or there is a suspicion
of flammable gas:
Ø Do not operate or switch on any
electrical equipment.
Ø Ensure there is an adequate supply
of fresh air into the dwelling.
Ø Leave the building.
Ø Call the fire brigade.
WARNING
Risk of burns from flambéing, naked
flames or overheated fat/oil under the
device.
Naked flames can cause burns, e.g. to
the skin.
Ø Always keep naked flames small
(e.g. with a gas cooker). The gas
flame should not extend beyond the
base of the pan.
Ø Prepare foods using fats or oils only
under supervision.
Ø Do not flambé underneath the
device.
Page 14
Operating
14 Operating instructions
ATTENTION
Risk of fire due to flambéing or
overheated oil and fat under the
device.
Naked flames can cause damage to
neighbouring cabinets and objects for
example.
Ø Never leave deep fat fryers
unattended during use.
Ø Do not flambé underneath the
device.
The following tip only applies for recirculated air mode.
Ø If you turn the device on and notice unpleasant
odours, then you should replace the filter's
filling.
See Cleaning starting at page 17.
If you turn on the device and notice that the fan noise
has increased, you should clean the device.
See Cleaning starting at page 17.
After six hours of continuous operation the device
automatically switches off the ventilation mode.
Ø If required, turn the device on again.
To remove cooking vapours best:
Ø Turn the device on when you start cooking.
Ø If you are frying, turn the device to its highest
power setting.
Use the run-on function in hybrid and
recirculated air modes so that the filter used
(BHF or BUF) is dried after the actual cooking
process. This prevents smells developing and
ensures it reaches its maximum service life.
You can operate the device in four different power
levels.
To turn the device on, proceed as follows:
Ø Turn the rotary knob clockwise from level "0" to the
desired power level.
The rotary knob snaps into each power level.
The device operates immediately at the selected power
level.
Changing the power level
During operation, you can set a different power level at
any time.
Ø Turn the rotary knob from the current position to
the position of the desired power level.
The rotary knob snaps into each power level.
The device operates at the selected power level.
After six hours of continuous operation the device
automatically switches off the ventilation mode.
Ø If required, turn the device on again.
Page 15
Operating
Operating instructions 15
Turning off the ventilation function
To turn off the ventilation function, proceed as follows:
Ø Turn the rotary knob anti-clockwise to the "0"
position.
The rotary knob snaps into each power level.
The device turns off the ventilation function.
Page 16
Operating
16 Operating instructions
Turning the lighting on and off
The device is fitted with an energy saving LED light to
light up the hob.
The lighting can be used independently from the fan.
Turn the lighting on
To turn on the lighting, proceed as follows:
Ø Press on the rotary knob with a finger.
The lighting is switched on.
Turn the lighting off
To turn off the lighting, proceed as follows:
Ø Press on the rotary knob with a finger.
The lighting is switched off.
Page 17
Cleaning
Operating instructions 17
Cleaning
DANGER
Fatal electrical shocks through liquids
that get into the device.
Ø Never spill liquids into the device.
Ø Ensure that fluids never get into the
device.
WARNING
Risk of fire from grease residues in
and on the device.
Ø You should regularly clean the
device.
ATTENTION
Damage to the surfaces from sharp
objects or abrasive cleaning agents.
Ø Never use sharp objects, abrasive or
aggressive cleaning agents.
Ø Use a soft, damp cloth.
Cleaning intervals
Usage Time interval
Little or
occasional
use.
After each cooking session.
See Cleaning with normal soiling on
page 17.
Daily or
heavy
use.
At least every three weeks.
See Cleaning when heavily soiled on
page 18.
Cleaning with normal soiling
The device is designed to capture foreign particles
from the room air that is sucked in and to collect them
in a grease tray.
Proceed as follows to clean the device at normal
soiling levels:
Ø Turn off the device.
Ø Open the lower section by pulling the rounded
edge on the front side downwards.
Ø Use a soft, damp cloth or kitchen paper towels for
cleaning.
Ø Wipe off the upper and lower sections.
Close the lower section.
Ø Close the lower section by pushing it upwards until
the two magnetic fasteners can be heard to click
together.
Page 18
Cleaning
18 Operating instructions
Cleaning when heavily soiled
If the device is heavily soiled, you must remove the
lower section and the capillary trap. These can be
easily removed and refitted, and they can be reused
after they have been cleaned.
Proceed as follows to clean the device at heavy soiling
levels:
Remove the lower section
Ø Turn off the device.
Ø Open the lower section by putting the rounded
edge downwards.
Ø Use a soft, damp cloth or kitchen paper towels for
cleaning.
Ø Wipe off the upper and lower sections.
Ø Grasp the lower section on its sides with both
hands when it is hanging down perpendicularly.
Ø Lift the lower section about 2 cm (1.).
Ø Release the lower section by pulling it forwards
(2.).
Ø Remove the lower section.
Page 19
Cleaning
Operating instructions 19
Remove the capillary trap
Ø Grasp the sides of the capillary trap with both
hands.
Ø Pull the capillary trap downwards.
Clean the parts
ATTENTION
Damage to the lower section by
improper cleaning.
Ø Clean the lower section e.g. with a
damp cloth.
Ø Clean the lower section e.g. with a damp cloth.
Ø Clean the upper section e.g. with a damp cloth.
Ø Clean the capillary trap e.g. in the dish washer.
Ø Clean the four surfaces of the recess for the
capillary trap e.g. with a damp cloth.
Ø Clean the two edges above the recess for the
capillary trap e.g. with a damp cloth.
After cleaning replace the cleaned and dry parts as
follows:
Insert the capillary trap
Ø Make sure that the capillary trap is completely dry
before re-inserting.
Ø Insert the capillary trap into the device by pressing
it firmly upwards with both hands.
The capillary trap snaps into place.
Page 20
Cleaning
20 Operating instructions
Reassemble the lower section.
Ø Grip the lower section with both hands.
Ø Insert the lower section into the device from below
until the guide grooves of the lower section are in
front of the device guide pins at the same time.
Ø Press the lower section rearwards into the device
(1.).
Ø Pull the lower section downwards (2.) until it clicks
into place.
Ø Make sure that the lower section is fitted correctly.
The lower section is fitted correctly when you can
move it easily.
Close the lower section.
Ø Close the lower section by pushing it upwards until
the two magnetic fasteners can be heard to click
together.
Cleaning the surfaces
ATTENTION
Damage to the surfaces from sharp
objects or abrasive cleaning agents.
Ø Never use sharp objects, abrasive or
aggressive cleaning agents.
Ø Use a soft, damp cloth.
Clean the surfaces with a soft, damp cloth and a mild
household cleaner.
Page 21
Cleaning
Operating instructions 21
Cleaning the rotary knob
The rotary knob (ThinCoder) is fitted to the device on
one axis. This axis has been milled off on one side. A
matching opening is found as a counterpart on the
underside of the rotary knob. The rotary knob can only
be attached if the milled sides are turned so they match
each other.
Removing the rotary knob
Ø Pull off the rotary knob.
Cleaning the rotary knob
Ø Clean the rotary knob in the dishwasher or using a
damp cloth.
Fitting the rotary knob
ATTENTION
Damage to the rotary knob through
misalignment.
Ø Turn the rotary knob around to the
correct installation position.
Ø Install the rotary knob by pushing it upwards (1)
when it is in the correct installation position.
Page 22
Maintenance
22 Operating instructions
Maintenance
Maintaining the device
The device is maintenance-free.
Changing the bulbs
The device is fitted with LED lighting. The bulbs have a
service life of approximately 50,000 operating hours.
Ø If you have any problems, contact your berbel
dealer or customer services.
Changing the filter filling (hybrid and recirculated air filters)
Replace the filter filling in accordance with the following
table:
Usage Time interval
Little or
occasional
use
At least every 24 months or when there
are odours in the exhaust air.
Daily or
heavy use
At least every 12 months or when there
are odours in the exhaust air.
WARNING
Risk of falling when changing the filter
or during work carried out at height.
Ø Use a stable step-ladder.
WARNING
Risk of injury from hot parts.
Ø Ensure that the cooking hob and the
device have cooled down.
Ø Let all parts cool down before
beginning work.
WARNING
Risk of injury from falling parts.
Ø Ensure that no-one is beneath the
working area when working on the
device.
ATTENTION
Damage caused by falling parts.
Ø Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
The filter must be easily accessible.
Ø Remove all the screens and other attached
modifications. The filter must be easily accessible.
The filter is easily accessible.
Page 23
Maintenance
Operating instructions 23
Removing the hybrid filter
To change the filter filling, proceed as follows:
Ø Remove the exhaust pipe from the socket.
Ø Remove the socket from the filter.
Ø Remove the exhaust pipe from the hybrid filter.
Ø Lift the filter at least 3 cm (1.).
Ø Remove the filter to the front (2.).
The filter is removed.
Remove the recirculation air filters.
To change the filter filling, proceed as follows:
Ø Lift the filter at least 3 cm (1.).
Ø Remove the filter to the front (2.).
The filter is removed.
Change the filter filling
The method for changing the filter's filling is
described separately in an instruction manual for
the filter filling.
Ø Change the filter's filling.
Page 24
Maintenance
24 Operating instructions
Replace the filter
To make sure that the filter is installed correctly,
a guide is installed on the filter seating.
Ø Insert the filter into the device from the top.
The filter is inserted correctly when the bottom edge of
the filter is parallel to the top edge of the fan's housing
and the gap is approximately 5 mm wide.
Ø Make sure that the filter is inserted correctly.
If the filter is not correctly fitted, proceed as follows:
Ø Remove the filter.
Ø Replace the filter again.
Only in hybrid operation:
Ø Push the exhaust pipe onto the filter collar.
Ø Seal the transition between the exhaust pipe and
the guide with the help of sealing tape.
Ø Ensure that the exhaust pipe is correctly fitted.
Ø Fit the screens or other attached modifications.
The filter filling has been exchanged.
Page 25
Troubleshooting
Operating instructions 25
Troubleshooting
DANGER
Fatal electric shock due to improperly
carried out repairs.
Ø Ensure that all repairs are carried out
by the manufacturer or by
authorised, specialised personnel.
Fault Possible cause Remedy
No power supply. Check that the all-pole mains switch is
turned on.
Switch the mains switch on.
Fan and lighting do not
work.
The fuse may have been tripped or is
defective.
Check to see if the fuse has tripped.
When you use electric circuit breakers, turn
the circuit breaker on again.
For other types of fuse, consult a qualified
electrician.
The extractor hood is not switched on. Check all possible power levels.
See Turning on the ventilation function on
page 13.
The fan does not work.
The extractor hood is connected to a
window contact switch and the window
is closed.
Open the window.
BLB 60 FLE/90 FLE:
External fan does not
function.
No power supply or connecting cable is
not plugged in or connected.
Please consult your berbel dealer.
The lighting does not
work.
The bulb has blown. Please consult your berbel dealer.
Smells occur during
operation.
The filter filling is used up. Change the filter filling.
See Changing the filter filling (hybrid and
recirculated air filters) on page 22.
Page 26
Troubleshooting
26 Operating instructions
Fault Possible cause Remedy
The recirculated air filter is clogged. Replace the filter filling of the recirculated
air filter.
See Changing the filter filling (hybrid and
recirculated air filters) on page 22.
The hybrid filter is blocked. Replace the filter filling of the hybrid filter.
See Changing the filter filling (hybrid and
recirculated air filters) on page 22.
Poor device
performance.
The exhaust pipe was not properly
connected or installed.
Please consult your berbel dealer or berbel
customer services.
Ø If the fault persists, please contact your berbel
dealer or berbel customer services.
Page 27
Installation instructions
Installation instructions 27
Installation instructions
Description for the installer
Possible operating modes
The following illustrations show the way the
possible operating modes work. The devices
used are shown as symbols. The illustrations are
meant to serve as a guide. The illustrated device
shapes may differ from your device.
The device can be fitted in different operating modes:
§ Recirculated air mode
§ Extracted air mode
§ Hybrid mode
Depending on the desired operating mode, the
installation of the device varies. The different
installations of the individual operating modes are
described in the following sections.
Ø Make sure that all safety instructions and
regulations are adhered to during installation.
Installation for recirculated air mode
In this installation a BUF recirculated air filter is fitted to
the device's fan outlet.
Ø Make sure that the cross-section of the ventilation
slits in the top structure is more than 300 cm².
Ø Make sure that the air can flow freely out of the
device.
Ø Ensure that you can change the filter filling at a
later date.
The filter's filling needs to be regularly replaced.
Installation for extracted air mode
Observe and follow the information concerning
the exhaust pipe in the Information about
extracted air mode chapter.
In this installation the exhaust pipe is fitted to the
device's fan outlet.
Ø Make sure that the exhaust pipe has a diameter of
at least 125 mm.
Ø Make sure that the air can flow freely out of the
device.
Page 28
Installation instructions
28 Installation instructions
Installation for hybrid mode
In this installation a BHF hybrid filter is fitted to the
device's fan outlet. The exhaust pipe is connected to
the hybrid filter.
Ø Make sure that the cross-section of the ventilation
slits in the top structure is more than 200 cm².
Ø Make sure that the exhaust pipe has a diameter of
at least 125 mm.
Ø Make sure that the air can flow freely out of the
device.
Ø Ensure that you can change the filter filling at a
later date.
The filter's filling needs to be regularly replaced.
Information about extracted air mode
DANGER
Danger of suffocation due to lack of
oxygen when the device is operated at
the same time as there is an open fire.
Ø If the device is operated at the same
time as devices which work using
room air (e.g. gas stove, fire places
or gas heaters), no gases or exhaust
gases are drawn into the room.
Ø Ensure there is an adequate supply
of fresh air into the dwelling.
Ø Make sure that the legal provisions
of the fire regulations (FeuV in
Germany) applicable to your
location/federal state are observed.
Ø Make sure that you have obtained
the permit from your master chimney
sweep to operate the extractor hood,
if required.
Measures to ensure a sufficient supply of fresh air:
§ Operate the device only when a window contact
switch is fitted.
§ Open the window.
§ Open the door.
§ Install a berbel BMK wall box.
§ Ensure that the prescribed forced ventilation of the
open fire is working.
Page 29
Installation instructions
Installation instructions 29
WARNING
Suffocation risk due to low oxygen
levels when operating the device.
Ø Ensure there is an adequate supply
of fresh air into the dwelling.
Ø Make sure that the device is
connected to a window contact
switch for safe operation.
Ø Make sure that all country-specific
statutory regulations are observed
(e.g. in Germany the requirements of
the federal state's fire regulations).
If there is to be simultaneous operation of an extractor
hood and a room-air supplied fireplace (e.g. gas, oil, or
coal fired heaters, fireplaces, water heaters, gas hobs
or ovens), the following requirements must be met:
Ø Your local master chimney sweep has approved
the installation of the extractor hood.
Ø The installation must be done taking the country-
specific regulations of your federal state into
account (e.g. the state fire regulations).
Ø The installation must be done taking all the
regulatory and legal requirements into
consideration (e.g. state building codes).
In extracted air mode, the device draws in air from the
room and expels it outwards through the exhaust pipe.
The device can only extract the amount of air that is
drawn into the kitchen.
The cross-section, length, type and course of the
exhaust pipe affect the extraction efficiency of an
extractor hood greatly.
Power loss and noise can be created by tightly diverted
air in the exhaust pipe.
To ensure optimum performance of the device, you
should ensure that, when installing the exhaust hose:
§ The exhaust hose is as short and direct as possible.
§ The room air to be extracted is able to flow freely
through the exhaust pipe without turbulence and
back pressure.
§ The prescribed cross-section of the exhaust pipe is
observed.
§ The recommended composition of the exhaust pipe
is maintained throughout its length.
The following section explains what the requirements
and properties of the exhaust pipe should be.
Exhaust in a separate exhaust duct.
DANGER
Suffocation risk from smoke or fumes.
Ø Make sure that the exhaust channel
used is only used and designed for
operating an exhaust hood.
Ø Ensure that the exhaust channel is
only used by this device. If
connecting the device to an active
exhaust duct, like a ventilation shaft
or chimney, gases or fumes could be
drawn into the room.
DANGER
Fire hazard due to flammable exhaust
pipe.
Running a flammable exhaust pipe
through a second room or attic could
spread a fire into other rooms.
Ø Ensure that the exhaust pipe is
made of non-combustible material in
accordance with DIN 4102 class A1.
You may only extract the room air through a separate
and suitably designed exhaust channel to the outside.
Ø Ensure that the exhaust channel used is only used
by this device as an exhaust pipe.
Page 30
Installation instructions
30 Installation instructions
Exhaust pipe optimisation
Room air extracted on the direct route
Lead the room air extracted directly and via the
shortest route to the outside. Long routes create
additional, unwanted air resistance.
Ø Ensure that the exhaust pipe is directly fed outside
via the shortest route.
Use pipes with low air resistance
Only use tubes with a smooth surface on the inside.
Such pipes have a low air resistance.
Avoid the installation of:
§ Spiral hoses
§ Flexible tubes
§ Flat corner pieces.
These types of tubes have a higher air resistance and
reduce the performance of the extractor hood.
Ø Make sure that the exhaust pipe has a smooth
surface on the inside.
Only use bends with optimal air paths and a smooth
surface on the inside. These bends have low air
resistance (e.g. berbel bends).
Avoid using bends with sharp-edged air guides.
These bends have a high air resistance and produce
noises. These bends reduce the performance of the
extractor hood.
Ø Make sure that the bends in the exhaust pipe have
a smooth surface on the inside and that the air
path is optimised (e.g. berbel bends).
Use a suitable cross-section
The minimum cross-section for the exhaust pipe for the
125-systems (BEH 60/90 and BLB 60 FL/90FL) is 125
mm and for the 150 systems (all other berbel extractor
hoods) is 150 mm.
Every reduction in the exhaust hose causes unwanted
air resistance, performance reduction and noises.
Avoid:
§ Exhaust pipes of a smaller diameter.
§ Sharp-edged exhaust flat air ducts.
§ Conventional wall boxes.
These have a high air resistance and cause noises.
They reduce the performance of the extractor hood.
Ø Make sure that the minimum cross-section of the
exhaust pipe is not less than the cross-section of
the fan outlet.
Ø Use berbel pipes, bends and the optimal berbel
BMK wall box, for example.
Exhaust pipe through an old chimney
DANGER
Suffocation risk from smoke or fumes.
Ø A master chimney sweep must
approve the use of the chimney as
an exhaust pipe prior to installing the
extractor hood.
DANGER
Fire hazard due to flammable exhaust
pipe.
Running a flammable exhaust pipe
through a second room or attic could
spread a fire into other rooms.
Ø Ensure that the exhaust pipe is
made of non-combustible material in
accordance with DIN 4102 class A1.
If you use a chimney as the exhaust pipe, you must
expect increased air resistance in relation to the length
of the chimney.
Page 31
Installation instructions
Installation instructions 31
The extracted air must be introduced into the chimney
using a 90° bend pointing upwards. This will prevent a
possible back pressure.
Ø Make sure that the connection to the chimney is via
a 90° bend which points upwards.
Exhaust pipe through the roof
DANGER
Fire hazard due to flammable exhaust
pipe.
Running a flammable exhaust pipe
through a second room or attic could
spread a fire into other rooms.
Ø Ensure that the exhaust pipe is
made of non-combustible material in
accordance with DIN 4102 class A1.
ATTENTION
Water damage to the device caused by
lack of a condensation trap.
Ø Fit a condensation trap to the
exhaust pipe.
If you run the exhaust pipe out through the roof, you
must ensure that:
§ The pipe diameter of the fan outlet is not larger than
the diameter of the roof feed through.
§ The roof feed through does not reduce the cross-
section of the exhaust pipe.
§ A sufficiently large condensation trap is integrated
into the exhaust pipe that does not reduce the
cross-section of the exhaust pipe.
Exhaust pipe through the exterior wall
DANGER
Fire hazard due to flammable exhaust
pipe.
Running a flammable exhaust pipe
through a second room or attic could
spread a fire into other rooms.
Ø Ensure that the exhaust pipe is
made of non-combustible material in
accordance with DIN 4102 class A1.
If you run the exhaust pipe out through an exterior wall,
you must ensure that:
§ The diameter along the exhaust pipe is not smaller
than the diameter of the fan outlet.
§ The wall feed through does not reduce the diameter
of the exhaust pipe.
The wall box must meet the following requirements:
§ The diameter of the fan outlet must not be larger
than that of the wall box.
§ The wall box's louvred cover must have a large vent
area.
Page 32
Installation instructions
32 Installation instructions
Ensure that:
§ The slats of the wall box's louvred cover are not
narrow and thick.
§ The slats of the wall box's louvred cover do not
hang straight down.
§ There is no insect screen fitted in the wall box.
Insect screens impair the cross-section of the
exhaust pipe completely.
Ø Use only flow optimised wall boxes (e.g. BMK F/L).
Page 33
Description for the installer
Installation instructions 33
Basics about the device
The BLB 60 FLE and BLB 90 FLE devices are
operated with an external fan.
To ensure the device functions optimally, it is
essential to observe the prescribed volume flows!
These devices can only be used in extracted air
mode.
The diameter of the pipe connection for the BLB
60 FL and BLB 90 FL devices
is Ø 125 mm.
The diameter of the pipe connection for the BLB
60 FLE and BLB 90 FLE devices
is Ø 150 mm.
The BLB 60 FLE and BLB 90 FLE devices can
also be delivered with a side (right or left) 150
mm x 80 mm large flat duct connection.
The device is designed to be installed flush in
cupboards.
The device is controlled using the controls in the
middle of the front panel.
Page 34
Description for the installer
34 Installation instructions
Device view from above
Fan module BLB 60 FL Right bracket
Fan module BLB 90 FL Left bracket
As a option, only for BLB 60 FLE and BLB 90 FLE:
Side flat channel connector 150 mm x 80 mm
Only BLB 60 FLE and BLB 90 FLE:
Connection socket for external fan
Fan outlet
Mains plug
Contact terminals for the window switch and the
wall box
Page 35
Description for the installer
Installation instructions 35
Device view from underneath with a closed lower section
Fan module BLB 90 FL Lower section
Fan module BLB 60 FLE Illumination
Rotary knob (on and off switch)
Page 36
Description for the installer
36 Installation instructions
Device view from underneath with opened lower section
Fan module BLB 90 FL Capillary trap
Fan module BLB 60 FLE Lower section
Upper section
Page 37
Preparation for installation
Installation instructions 37
Preparation for installation
In this chapter you will learn what the prerequisites are
for installation. Perform all the steps in this guide one
after the other.
Ø Make sure that all the safety instructions from the
chapters "General Safety Instructions" and "Safety
Instructions for the Installer" are followed.
WARNING
Risk of injury from falling parts with
improper fastening or too low bearing
capacity of the cabinet.
Ø Ensure that the cabinet has sufficient
bearing capacity.
Do not attempt to carry out the
installation where the required
bearing capacity cannot be assured.
Ø Only use suitable fastening
materials.
The supplied fastening material is
only to be used for fastening into a
stable cabinet (e.g. 16 mm wooden
sheets). If there are other installation
conditions, you can ask your
architect for example, about
alternative fastening methods before
installation.
Ø Ensure that the device is correctly
suspended.
Ø Ensure that the power supply meets the voltage
supply specified on the ratings plate.
Ø Ensure that the connection to the power supply is
made after the device is installed.
Ø Make sure that the device can be disconnected on
all poles from the electricity supply after
installation.
Qualifications of personnel
Two persons are required to mechanically install the
device.
These technicians must have sufficient craftsman skills
and knowledge.
The required specialist skills include:
§ Knowledge of the regulations on safety at work
§ Ability to read technical drawings
§ Experienced in using electrical and mechanical
tools
§ Knowledge of fastening systems
§ Basic knowledge of ventilation systems
§ It would be ideal to have several years experience
in installing extraction hoods and further additional
qualifications, like an apprenticeship as a carpenter
for example.
Persons without this specialist knowledge must be
trained by an experienced technician in the installation.
Prerequisites for the mechanical end assembly
The required prerequisites for the installation include:
§ The cabinet is has sufficient bearing capacity.
§ The socket for the power supply is to be provided
on-site, installed by a qualified electrician.
§ For the BLB 60 FLE and BLB 90 FLE:
The external fan is fitted.
The cable to control the external fan is laid on-site
to the installation position.
§ For exhausted air and hybrid operation:
The connection cables for the wall boxes and/or
window contact switches are laid on-site to the
installation position.
§ For exhausted air and hybrid operation:
The exhaust pipe is laid on-site to the installation
location.
Page 38
Preparation for installation
38 Installation instructions
Brief overview of the installation
The installation is done in the following steps:
§ Remove the lower section.
§ Remove the capillary trap.
§ Tighten up the lever of the fastening mechanism.
§ Remove the bracket.
§ Determine the exact installation location.
§ Make the installation cut-out here.
§ Install the brackets.
§ Mount the device.
§ Secure the device.
§ For the BLB 60 FLE and BLB 90 FLE:
Connect the control cable from the external fan.
§ When using a wall box or a window contact switch:
connect the cable.
§ When in recirculated air or hybrid mode:
insert the filter.
§ When in exhausted air or hybrid mode:
attach the exhaust pipe.
§ Plug in the plug for the power supply.
§ Attach the remaining parts.
Prepare the plug socket for the power supply
DANGER
Lethal electric shock caused by
improper connection.
Ø Working on the power supply may
only be done by qualified, trained
electricians adhering to the country-
specific regulations and standards
(e.g. in Germany DIN 57100 / VDE
0100, part 701).
DANGER
Danger, for example of a fatal electric
shock by faults caused by an
inaccessible plug socket.
Ø Ensure that the power plug is freely
accessible so that you can easily
and simply isolate the device from
the power supply in an emergency.
Ø If the plug socket is not easily
accessible, an all-pole isolating
device (with a contact gap of at least
3 mm) must be provided on-site.
Ø Only allow the required plug socket to be installed
by a qualified electrician.
Ø Ensure that a plug socket is installed at a
maximum separation distance of 1.2 metres.
Ø Make sure that the building electrical supply is
properly earthed.
Ø Make sure that the power supply voltage meets the
value on the ratings plate on the inside of the
device.
Ø Ensure that the connection to the power supply is
made after the device is installed.
Page 39
Preparation for installation
Installation instructions 39
Prepare the connection cable for the power supply
The connection to the in-house power supply is made
using a power plug. The power cable fitted to the
device is 1.3 metres long.
Ø Make sure that the device can be disconnected on
all poles from the electricity supply after installation
(the switch should have a minimum 3 mm opening
gap).
Ø Make sure that the power supply voltage meets the
value on the ratings plate on the inside of the
device.
Ø Make sure that the mains voltage is turned off for
the remainder of the installation of the device.
Prepare the connection cables for wall box and window contact switch
You can connect the device to a window contact switch
and a berbel wall box (e.g. BMK F). The cable clamps
are fitted to the device's housing. The connection
cables should be laid prior to installing the device.
Wiring diagram for the window contact and the wall box contact
ATTENTION
You can damage the electronics if you
connect the control cables with the
wrong polarity.
Ø Make sure that you connect the right
poles of the control cable.
Ø Connect wire 1 to connector 1, and
wire 2 to connector 2.
Terminal for the multi-function contact (F-K)
Terminal for the wall box (BMK)
Control cable
Power supply
Wall box BMK F
Control contact, potential-free
Control box of the berbel extractor hood
Page 40
Preparation for installation
40 Installation instructions
Tools and equipment needed
For installation you need the following tools, materials
and documents:
Folding ruler
Pencil  Cross-head screwdriver  2.5 mm ball Allen key  Jigsaw  Thick cardboard e.g. to protect the cooking hob
and the work surface
These installation instructions
Unpacking
CAUTION
Risk of injury from broken glass.
Ø Wear protective gloves.
Ø Unpack the device carefully.
Ø Do not touch broken glass.
ATTENTION
Damage to the surfaces from improper
unpacking.
Ø Cut the packing tape and straps with
scissors.
Ø Do not cut into the protective
cardboard packaging.
ATTENTION
Scratched surfaces from metallic,
sharp-edged objects, e.g. belt buckles
or tools during transport.
Ø Transport the device without any
contact to objects that could scratch
the device.
Ø Remove the packing foil and the cardboard
packaging.
Ø If present, cut off the holding strap with scissors.
Page 41
Preparation for installation
Installation instructions 41
Ø Cut the packing tape using scissors.
Ø Take the loose parts out of the packaging.
CAUTION
Risk of injury from the heavy extractor
hood falling.
Ø Lift the device only with two persons.
Ø Protect the surfaces of the working area, e.g. using
thick cardboard.
Ø Remove the parts from the packaging.
Ø Place the pars on a level, protected surface.
Check the delivery
Ø Makes sure that all the parts are complete as
described in the following section.
Ø Check the delivered parts for damage.
Ø If any parts are damaged or missing, contact your
berbel dealer or customer services.
Scope of delivery BLB 60 FL(E)
Fan module BLB 60 FL(E)
Left bracket
Right bracket
Installation Instructions
6 x screws (cross-head) 4.5 x 16 mm
Only for BLB 60 FLE:
The connection cable for an external fan (e.g.
BAL 150) is included with the fan. The cable is 5
m long.
Page 42
Preparation for installation
42 Installation instructions
Scope of delivery BLB 90 FL(E)
Fan module BLB 90 FL(E)
Left bracket
Right bracket
Installation Instructions
8 x screws (cross-head) 4.5 x 16 mm
Only for BLB 90 FLE:
The connection cable for an external fan (e.g.
BAL 150) is included with the fan. The cable is 5
m long.
Optional accessories
Only for hybrid mode:
Hybrid filter BHF 125
Only for recirculated air mode:
Recirculated air filter BUF 125 +
Wall box BMK F/L
Remove the parts for installation
Prior to installation, there are individual components
that must be removed or dismantled to be able to
safely install the device.
Ø Perform the following steps sequentially.
Ø Place the device on its back on a flat, clean and
protected surface.
The following illustrations show a device that is
already installed. They are only as a guide for the
installer. The device must lie on its back for the
following steps, and the actions are to be
implemented according to the perspective.
Page 43
Preparation for installation
Installation instructions 43
Remove the lower section
Ø Open the lower section by pulling the lower section
downwards on the rounded edge.
Ø Grasp the lower section on its sides with both hands
when it is hanging down perpendicularly.
Ø Lift the lower section about 2 cm (1.).
Ø Loosen the lower section by pulling it forwards (2.).
Ø Remove the lower section.
Remove the capillary trap
Ø Grasp the sides of the capillary trap with both hands.
Ø Pull the capillary trap downwards using both hands.
Page 44
Preparation for installation
44 Installation instructions
Remove the bracket
To remove the bracket from the device, proceed as
follows:
Ø Press both levels at the side in the bay for the
capillary trap backwards (1.) until they are heard to
click into place.
Ø Pull off both brackets (2.).
Ø Label the brackets "Left" and "Right".
Create the installation cut-out
The installation cut-out must have the following
dimensions:
BLB 60 FL
BLB 60 FLE
BLB 90 FL
BLB 90 FLE
Width "X"
(in mm)
540 mm 840 mm
Depth "Y"
(in mm)
338 mm 338 mm
Minimum distance
"Z"
to the rear wall
(in mm)
15 mm 15 mm
You need a saw for this work step (e.g. jigsaw).
Ø Protect all the surfaces of your working area from
damage, e.g. using thick cardboard or foam.
Page 45
Installing the device
Installation instructions 45
Ø Cut out the installation cut-out in accordance with the
dimensions specified for your device.
Installing the device
WARNING
Risk of injury from falling parts.
Ø Ensure that no-one is below the working
area during the work.
WARNING
Risk of injury from falling parts if improperly
fastened.
Ø Ensure that the cabinet has sufficient
bearing capacity.
Ø Only use suitable fastening materials.
The supplied fastening material is only to
be used for fastening into a stable cabinet
(e.g. 16 mm wooden sheets). If there are
other installation conditions, you can ask
your architect for example, about
alternative fastening methods before
installation.
Ø Ensure that the device is correctly
suspended.
ATTENTION
Damage caused by falling parts.
Ø Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
The device is suspended using two brackets.
Page 46
Installing the device
46 Installation instructions
Safety distances are observed
The following illustrations show the operation or
dimensions.
The devices used are shown as symbols. The
illustrations are meant to serve as a guide. The
illustrated device shapes may differ from your
device.
The following statutory minimum separation distances
must be observed:
Description Size
Y 0 mm
X For gas hobs:
at least 650 mm.
For electric hobs:
at least 350 mm.
Recommended distance:
550 mm
Fitting the bracket BLB 60 FL(E)
The supplied brackets are suitable for 16 mm to
22 mm thick cabinet bases. The corresponding
dimension must be adjusted by the installer.
For this work step you need a large Phillips
screwdriver.
Both removed brackets are screwed from above onto
the base plate of the cabinet.
The brackets are pre-set in the factory for 16 mm thick
base plates. The brackets must only be adjusted for
thicker base plates.
The brackets consist of two parts which are screwed
together. One part of the bracket is fitted with slotted
holes. You can adjust the bracket to the base plate
thickness by sliding it.
Ø Loosen both screws.
Ø Adjust to the required dimension by sliding the upper
part of the bracket accordingly.
Ø Re-tighten up both screws.
Ø Ensure that both brackets are correctly adjusted.
Both bent metal tabs are above and point to the interior
of the cabinet.
Ø Place the right-hand bracket from above on the rear
corner of the installation cut-out (1.) until the
fastening tabs lie on the base plate.
Ø Ensure that the bracket lies flush.
Ø Screw the bracket flush to the side edge (2.).
Ø Slide the bracket rearwards (3.) until the bracket lies
flush to the rear edge.
Ø Ensure that the bracket is flush with the rear and the
side edges of the installation cut-out.
Ø Fasten the bracket with the cross-head screws (4.)
included in delivery.
Ø Tighten up the cross-head screws.
Page 47
Installing the device
Installation instructions 47
Ø Ensure that the bracket is firmly mounted in the
correct installation position.
Ø Repeat this process with the left-hand bracket.
Fitting the bracket BLB 90 FL(E)
The supplied brackets are suitable for 16 mm to
22 mm thick cabinet bases. The corresponding
dimension must be adjusted by the installer.
For this work step you need a large Phillips
screwdriver.
Both removed brackets are screwed from above onto
the base plate of the cabinet.
The brackets are pre-set in the factory for 16 mm thick
base plates. The brackets must only be adjusted for
thicker base plates.
The brackets consist of two parts which are screwed
together. One part of the bracket is fitted with slotted
holes. You can adjust the bracket to the base plate
thickness by sliding it.
Ø Loosen both screws.
Ø Adjust to the required dimension by sliding the upper
part of the bracket accordingly.
Ø Re-tighten up both screws.
Ø Ensure that both brackets are correctly adjusted.
Both bent metal tabs are above and point to the interior
of the cabinet.
Ø Place the right-hand holder from above onto the base
plate (1.) until the fastening tabs lie on the base
plate.
Ø Ensure that the bracket lies flush.
Ø Slide the bracket (2.) to the side edge of the
installation cut-out until the bracket lies flush.
Ø Ensure that the bracket lies flush with the base plate.
Ø Ensure that the bracket lies flush to the side edge of
the installation cut-out.
Ø Fasten the bracket with the cross-head screws (3.)
included in delivery.
Ø Tighten up the cross-head screws.
Page 48
Installing the device
48 Installation instructions
Ø Ensure that the bracket is firmly mounted in the
correct installation position.
Ø Repeat this process with the left-hand bracket.
Hang the device
DANGER
Danger from falling parts if improperly
fastened.
Ø The supplied fastening material is
only to be used for installation into
an installation cut-out in a bearing
and stable wooden cabinet (e.g.
cabinet body).
Ø Make sure that the bearing capacity
is sufficient and use appropriate
fastening material.
For this step you do not require any tools.
Ø Ensure that both levers in the side of the capillary
trap bay are locked into the rear.
Ø With two persons, lift the device from underneath into
the base panel with the installation cut-out.
In the end position, the levers engage automatically
and hold the device.
Ø Push the device upwards until both levers engage.
Ø Ensure that both levers have engaged.
Page 49
Installing the device
Installation instructions 49
Align the device horizontally
For this step you do not require any tools.
You can slightly adjust the horizontal alignment of the
device. Proceed as follows:
Ø Push the device into the desired position by pushing
against the device on the side with your hand.
Secure the lock
For this work step you need a 2.5 mm ball Allen key.
To secure the lever after installing the device, proceed
as follows:
Ø Tighten the lever using your thumb.
Ø Screw both levers tight with the corresponding screw.
Page 50
Installing the device
50 Installation
instructions
Only BLB 60 FLE / BLB 90 FLE: Connect the connection cable of the fan
DANGER
Lethal electric shock caused by
improper connection.
Ø Only allow work on the power supply
to be carried out by qualified, trained
electricians adhering to the country-
specific regulations and standards
(e.g. in Germany DIN 57100 / VDE
0100, part 701).
WARNING
Risk of falling during work carried out
at height.
Ø Use a stable step-ladder.
CAUTION
Risk of injury from falling parts.
Ø Ensure that no-one is underneath
the working area while you are
working.
ATTENTION
Damage caused by falling parts.
Ø Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
The connection cable must be laid from the external
fan to the receptacle on the device.
Only BLB 60 FLE / BLB 90 FLE: Receptacle pin assignments
The receptacle is wired as follows:
Receptacle pin no. Description
1 Level 1
2 Level 2
3 Level 3
4 Level 4
5 N
6 PE
Only BLB 60 FLE / BLB 90 FLE: Controlling the individual fan speeds
Ø Ensure that only one power level can be switched
on at any one time.
Level 1 PE
Level 2 N
Level 3 L
Level 4
For this work step, you do not need any tools to
connect the berbel connection cable.
Proceed as follows:
Ø Push the plug of the connection cable firmly into the
receptacle on the device.
The connection cable for the fan is connected.
Page 51
Installing the device
Installation instructions 51
Connecting the wall box and the window contact switch contacts
DANGER
Lethal electric shock caused by
improper connection.
Ø Only allow work on the power supply
to be carried out by qualified, trained
electricians adhering to the country-
specific regulations and standards
(e.g. in Germany DIN 57100 / VDE
0100, part 701).
Ø Only allow a qualified electrician to carry out the
following steps.
You can connect the device to a window switch and a
berbel wall box (e.g. BMK F). The cable clamps for this
are attached to the fan housing of the device.
Wiring diagram for the window contact and the wall box contact
ATTENTION
You can damage the electronics if you
connect the control cables with the
wrong polarity.
Ø Make sure that you connect the right
poles of the control cable.
Ø Connect wire 1 to connector 1, and
wire 2 to connector 2.
Terminal for the multi-function contact (F-K)
Terminal for the wall box (BMK)
Control cable
Power supply
Wall box BMK F
Control contact, potential-free
Control box of the berbel extractor hood
Terminals for the wall box
The terminals for the wall box automatically control the
remote-controlled BMK wall box.
The control cable needs to be laid from the wall box to
the connection terminals for the wall box in the
extractor hood.
The terminals are marked in the extractor hood with
"BMK" or "wall box".
To connect the control cable, you need to attach the
two wires of the control cable to the terminals 1 and 2
for the wall box in the extractor hood. The wires are
marked with numbers. The control contact is potential-
free.
Page 52
Installing the device
52 Installation
instructions
§ The wall box is closed when the control contacts in
the extractor hood are open (see wiring diagram).
§ The wall box is open when the control contacts in
the extractor hood are closed.
In the following section, the connection of the BMK F
model series wall box is described.
For this work step, you need a small Phillips
screwdriver for the connection terminals in the berbel
extractor hood.
Ø Lay the control cable from the wall box to the
extractor hood.
Ø Make sure that the terminals for the wall box are
accessible in the extractor hood.
In the top corner of the control box are the terminals for
the window contact switch and the wall box contacts.
The terminals are labelled with "Fensterschalter"
(window switch) and "BMK" or "Mauerkasten" (wall
box). The terminal pairs are marked with 1 and 2.
To connect the control cable, proceed as follows:
Ø Open the screw of the BMK terminal 1.
Ø Take the wire 1 of the control cable.
Ø Insert wire 1 into terminal 1.
Ø Make sure that the wire-end ferrule of the control
cable is completely inserted into the terminal.
Ø Make sure that the insulation of the control cable is
not in the terminal.
Ø Tighten the screw of terminal 1.
Page 53
Installing the device
Installation instructions 53
Ø Connect the cable wire 2 in the same way to the
BMK terminal 2.
The control cable for the wall box is now connected.
Terminals for the window contact switch
You can connect a window contact switch to the
terminals for the window contact switch. The extractor
hood's fan is only operational when the window is
open.
The control cable needs to be laid from the window
switch to the connection terminals for the window
contact switch in the extractor hood.
The terminals for the window contact switch are
marked in the extractor hood with "Fensterschalter"
(window switch).
To connect the control cable, you need to attach the
two wires of the control cable to the terminals 1 and 2
for the window contact switch in the extractor hood.
The following step describes how the window contact
switch is connected.
For this work step, you need a small Phillips
screwdriver for the connection terminals in the berbel
extractor hood.
Ø Lay the window switch's control cable to the
device.
Ø Make sure that the terminals for the window
contact switch are accessible in the extractor hood.
In the top corner of the fan box are the terminals for the
window contact switch and the wall box contacts. The
terminals are labelled with "Fensterschalter" (window
switch) and "BMK" or "Mauerkasten" (wall box). The
terminal pairs are marked with 1 and 2.
To connect the control cable, proceed as follows:
Ø Open the screw of the "Fensterschalter" terminal 1.
Ø Take the wire 1 of the control cable.
Ø Insert wire 1 into terminal 1.
Ø Make sure that the wire-end ferrule of the control
cable is completely inserted into the terminal.
Ø Make sure that the insulation of the control cable is
not in the terminal.
Page 54
Installing the device
54 Installation
instructions
Ø Tighten the screw of terminal 1.
Ø Connect the cable wire 2 in the same way to the
"Fensterschalter" terminal 2.
The control cable for the window contact switch is now
connected.
Creating the exhaust air connection
You can install the device for different operating
modes:
§ Recirculated air mode
§ Extracted air mode
§ Hybrid mode
The installation for the individual operating modes is
described in the following sections.
Installing the device for recirculated air mode
WARNING
Risk of falling when changing the filter
or during work carried out at height.
Ø Use a stable step-ladder.
CAUTION
Risk of injury from falling parts.
Ø Ensure that no-one is underneath
the device while working.
ATTENTION
Damage caused by falling parts.
Ø Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
To make sure that the filter are installed correctly,
a guide is fitted to the device's filter seating.
The filter is inserted correctly when the bottom edge of
the filter is parallel to the top edge of the fan's housing
and the gap is approximately 5 mm wide.
Ø Insert the recirculated air filter from the top onto the
guide of the fan housing.
Ø Make sure that the filter is fitted correctly.
Page 55
Installing the device
Installation instructions 55
Installing the device for extracted air mode
WARNING
Risk of falling during work carried out
at height.
Ø Use a stable step-ladder.
CAUTION
Risk of injury from falling parts.
Ø Ensure that no-one is underneath
the device while working.
ATTENTION
Damage caused by falling parts.
Ø Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
Ø Push the exhaust pipe firmly into place on the
guide on the fan.
Ø Seal the transition between the exhaust pipe and
the guide with the help of sealing tape.
Ø Ensure that the exhaust pipe is correctly fitted.
Page 56
Installing the device
56 Installation
instructions
Installing the device for hybrid mode
WARNING
Risk of falling when changing the filter
or during work carried out at height.
Ø Use a stable step-ladder.
CAUTION
Risk of injury from falling parts.
Ø Ensure that no-one is underneath
the device while working.
ATTENTION
Damage caused by falling parts.
Ø Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
To make sure that the filter are installed correctly,
a guide is fitted to the device's filter seating.
The filter is inserted correctly when the bottom edge of
the filter is parallel to the top edge of the fan's housing
and the gap is approximately 5 mm wide.
Ø Place the hybrid filter onto the guide on the fan
housing from above.
Ø Make sure that the filter is fitted correctly.
Ø Push the exhaust pipe onto the filter collar.
Ø Ensure that the exhaust pipe is correctly fitted.
Page 57
Installing the device
Installation instructions 57
Install the other parts
After installation, fit the parts removed as follows:
Insert the capillary trap
Ø Place the capillary trap with both hands into the
device, and push it firmly upwards.
The capillary trap snaps into place.
Reassemble the lower section.
Ø Grip the lower section with both hands.
Ø Insert the lower section into the device from below
until the guide grooves of the lower section are in
front of the device guide pins at the same time.
Ø Press the lower section rearwards into the device
(1.).
Ø Pull the lower section downwards (2.) until it clicks
into place.
Ø Make sure that the lower section is fitted correctly.
The lower section is fitted correctly when you can
move it easily.
Close the lower section.
Ø Close the lower section by pushing it upwards until
the two magnetic fasteners can be heard to click
together.
Ø Remove any remaining protective foil from the
device.
Page 58
Initial cleaning
58 Installation i
nstructions
Connect the power supply
DANGER
Lethal electric shock caused by
improper connection.
Ø Only allow work on the power supply
to be carried out by qualified, trained
electricians adhering to the country-
specific regulations and standards
(e.g. in Germany DIN 57100 / VDE
0100, part 701).
Ø Insert the mains power plug into a power outlet.
The berbel extractor hood is installed and ready for
use.
Initial cleaning
ATTENTION
Damage to the surfaces from sharp
objects or abrasive cleaning agents.
Ø Never use sharp objects, abrasive or
aggressive cleaning agents.
Ø Use a soft, damp cloth.
Cleaning the surfaces
Ø Clean the surfaces with a soft, damp cloth and a
mild household cleaner.
Ø Dry the surfaces using a soft cloth.
Cleaning the controls
Ø Clean the surface of the control panel with a soft,
damp cloth.
Ø Dry the surfaces using a soft cloth.
Page 59
Disassembling the device
Installation instructions 59
Disassembling the device
DANGER
Lethal electric shock caused by
improperly performed electrical work.
Ø Only allow work on the power supply
to be carried out by a qualified
electrician adhering to the country-
specific regulations and standards
(e.g. in Germany DIN 57100 / VDE
0100, part 701).
WARNING
Risk of falling when changing the filter
or during work carried out at height.
Ø Use a stable step-ladder.
CAUTION
Risk of injury from falling parts.
Ø Ensure that no-one is underneath
the device while working.
ATTENTION
Damage caused by falling parts.
Ø Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
To remove the device you need a second person.
For this work step, you need a small flat-head
screwdriver, a Phillips screwdriver and a 2.5 mm ball
Allen key.
To remove the device, proceed as follows:
Ø Disconnect the power supply to the device on all
poles.
Ø Remove the mains plug.
Ø Remove the connection cables for the wall box and
the multi-function contact, if fitted.
Only BLB 60 FLE and BLB 90 FLE:
Ø Remove the connection cable for the fan.
Only for hybrid and extracted air mode:
Ø Remove the exhaust pipe.
Only for hybrid and recirculated air mode:
Ø Remove the filter.
Ø Open the lower section.
Ø Remove both screws on the levers.
ATTENTION
Damage caused by falling parts.
Ø Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
Ø Support the device with two people.
Ø Push both levers backwards until they lock.
Ø Lower the device with two people.
Ø Loosen the screws on the brackets.
Ø Remove the screws on the brackets.
Ø Remove the brackets.
The device is disassembled.
Page 60
Disposal
60 Installation
instructions
Disposal
Disposal of the packaging
DANGER
Danger of suffocation from packaging
components (e.g. foils and
polystyrene).
Ø Store the film or other parts of the
packaging in a location which is
inaccessible to children.
ATTENTION
Environmental damage caused by
incorrect packaging disposal.
Ø The packaging must not be disposed
of in normal household waste.
Ø Bring or send the packaging to an
environmentally friendly and correct
recycling facility.
The packaging is there to protect against damage
during transportation.
Only the original packaging guarantees sufficient
protection during transportation.
Ø Keep the packaging during the warranty period.
The packing materials were chosen with environmental
considerations in mind and are made from recyclable
materials. The packing materials can be returned into
the raw material cycle after use. As a result valuable
resources can be saved.
§ The outer packaging is made from cardboard.
§ The filling materials and layers are of cardboard of
polystyrene.
§ The protective foils and bags are made of
polyethylene.
Ø Dispose of the packaging, separated into material
groups, in an environmentally friendly way.
Disposal
ATTENTION
Environmental damage caused by
improper device disposal.
Ø Do not throw the device away with
the normal household waste.
Ø Check with your town or local council
about the facilities available for a
environmentally friendly and correct
recycling facility or a disposal site.
Ø Make the device unusable after disassembly, by
cutting the disconnected power cable for example.
Ø Dispose of the device according to legal
requirements using a waste management
company.
Page 61
Technical specifications
Installation instructions 61
Technical specifications
Ratings plate (type label)
The ratings plate is found inside the device behind the
lower section.
The following information
can be found on the ratings plate:
§ Manufacturer
§ Address of manufacturer
§ Device type
§ Voltage
§ Total power
§ Serial number
§ Year of manufacture
§ Symbols of compliance with the legal requirements
and test symbols.
The device was manufactured in compliance with the
regulations of VDE 60335-2-31 and meets the following
regulations and laws:
§ EMC regulation (EC directive 2004/104/EEC)
§ Low Voltage Directive 2006/95/EC.
Subject to technical changes.
Volume flow for operation with an external fan
If you want to operate the device in conjunction with an
external fan, the minimum volume flow rates at the fan
box outlet must be set:
Power level 1: min. 200 m³/h
Power level 2: min. 300 m³/h
Power level 3: min. 400 m³/h
Power level 4: min. 500 m³/h
Fan module BLB 60
BLB 60 FL BLB 60 FLE BLB 90 FL BLB 90 FLE
Width 550 mm 550 mm 850 mm 850 mm
Depth 350 mm 350 mm 350 mm 350 mm
Height 350 mm 245 mm* 350 mm 245 mm*
Max. fan power free
blowing
615 m³/h nom. volume 615 m³/h nom. volume
Pipe connection
(outlet on top)
Ø 125 mm Ø 150 mm Ø 125 mm Ø 150 mm
Pipe connection
(outlet on side)
nom. volume 150 mm x 80 mm
flat duct
nom. volume 150 mm x 80 mm
flat duct
Weight::
(without filter)
approx. 20 kg
approx. 9.5 kg
approx. 22.0 kg
approx. 12.5 kg
Power consumption 160 W 8 W 160 W 10 W
LED lighting 2x3.6 W/24 V 2x3.6 W/24 V 1x7.2 W/24 V 1x7.2 W/24 V
Supply voltage 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz
Page 62
62
Contact
If you have suggestions or queries, please choose from the following possibilities:
Post: berbel Ablufttechnik GmbH
Sandkampstraße 100
D-48432 Rheine
Telephone: +49 (0)5971 / 80 80 9-0
Mon to Thu 08.00 to 17.00 and Fri 08.00 to 14.00
Fax: +49 (0)5971 / 80 80 9-10
Internet: www.berbel.de
Contacting the customer services of the manufacturer
You can contact our customer service department in different ways: Choose from the following options:
Telephone: +49 (0)5971 / 80 80 9660
Mon to Thu 10:00 to 17:00 CET, Fri 10:00 to 14:00
Fax: +49 (0)5971 / 80 80 9 - 650
Page 63
Contact
63
Page 64
64
German language original manual created by: B. Gebhardt - Büro für Technische Dokumentation 45891 Gelsenkirchen www.tddv.de Printed in Germany Version: 04.08.2015 16:21
6001431 Subject to alterations without notice
Loading...