These instructions help you to use our product properly, safely and economically. In the following text, our berbel island extractor hood BIH 60 CB product is briefly referred to as device.
These instructions are intended for the following persons:
Persons who use the device
Persons who clean the device
Persons who dispose of the device.
Each of these persons must have read and understood the contents of these instructions.
Compliance with these instructions helps to avoid dangers and to increase the reliability and service life of the device.
Structural features in the text
Defined structural features are assigned to the elements contained in these instructions. A distinction can therefore be easily made between the following elements:
Normal text
Cross references
Lists or
¾ Action steps.
Tips contain special information on the economical use of the device.
Structural features in illustrations
The illustrations contain portrayals in various grey scales. Movements which are to be carried out are made clear using movement or direction arrows. If several action steps are portrayed in one illustration, the sequence is made clear using numbers (1., 2., ...):
If reference is made to elements in a legend or in the body text, these are provided with an item number (2):
2
1
3
Table of contents
Safety ..............................................................................................................................................................4
Proper use ..........................................................................................................................................................4
Ban on independent conversions and modifications ..........................................................................................4
Basic safety instructions .....................................................................................................................................4
Structural features of the information on dangers ..............................................................................................6
Structural features of notices regarding material or environmental damage......................................................7
Description.......................................................................................................................................................8
Possible operating modes ..................................................................................................................................8
View of the device with flap closed...................................................................................................................10
View of the device with flap open .....................................................................................................................11
View of the device from the left ........................................................................................................................12
Operation.......................................................................................................................................................13
Switching on the ventilation function ................................................................................................................13
Changing the output level.................................................................................................................................14
Switching off the ventilation function ................................................................................................................14
Switching on the run-on function ......................................................................................................................14
Switching the lighting on and off.......................................................................................................................15
Cleaning ........................................................................................................................................................17
Cleaning intervals .............................................................................................................................................17
Cleaning in the case of normal soiling..............................................................................................................17
Cleaning in the case of severe soiling ..............................................................................................................18
Cleaning surfaces .............................................................................................................................................21
Cleaning the rotary knob ..................................................................................................................................22
Maintenance ..................................................................................................................................................23
Maintaining the device......................................................................................................................................23
Maintaining the lighting.....................................................................................................................................23
Replacing the filter filling (hybrid and recirculating air filters)...........................................................................23
Rectifying malfunctions..................................................................................................................................30
Disposal.........................................................................................................................................................32
Disposing of packaging.....................................................................................................................................32
deviceDisposal..................................................................................................................................................32
Technical data ...............................................................................................................................................33
Model plate .......................................................................................................................................................33
Island Hood BIH 60 CB.....................................................................................................................................33
Contacting the manufacturer..........................................................................................................................34
Safety
4
Safety
Read through this chapter carefully before installing, using or cleaning the device.
¾ Observe all information on dangers during all
activities on the device.
¾ Enclose these instructions if you pass the device
on.
Proper use
The device can be used to extract cooking vapours during cooking.
The device is exclusively intended for this purpose and must only be put to this use. The device must only be used in the manner described in these instructions.
Any other use or modification of the device is regarded as improper and may lead to damage.
The manufacturer accepts no liability for damage caused as a result of improper use, incorrect installation or incorrect operation. The device is not intended for commercial use. Use the device in private kitchens only.
Ban on independent conversions and modifications
Do not undertake any independent conversions or modifications on the device. Conversions or modifications without the approval of berbel Ablufttechnik GmbH are impermissible.
Never bridge or bypass the protective facilities available on the device.
Basic safety instructions
This section contains basic safety instructions for handling the device. Additional safety instructions which affect certain actions and procedures can be found in the relevant chapters.
Heed all of the safety instructions and information
on dangers in these instructions.
Check the device and all parts for visible damage. In the event of damage, contact your specialist dealer or the berbel customer service. The device must only be used in flawless condition.
Always have repair and maintenance work carried out by qualified, specialist personnel. Otherwise, you endanger yourself and others.
Install the device with the enclosed brackets exclusively on load-bearing parts of buildings (solid construction).
In the case of other mountings, use correspondingly suitable mounting techniques. If in doubt, ask your specialist dealer. Otherwise, you endanger yourself and others.
Use the device in private kitchens only.
Safety
5
Avoiding dangers due to electric shock
Have work on the voltage supply carried out by a qualified, trained specialist electrician only. At the very least, the specialist electrician must have the following knowledge and skills:
Basics of electrical engineering
Knowledge of the country-specific regulations
and standards (in Germany e.g. DIN 57100/VDE 0100, Part 701)
Knowledge of the relevant safety regulations
Knowledge of the relevant legal regulations for
gas installations (in Germany e.g. the technical regulations for gas installations TRGI).
Only use the device if it is connected and fused according to the technical data.
Do not kink or crush the mains cable.
Do not operate the device with a damaged
electrical connection cable.
Disconnect the device from the current supply in the event of malfunctions.
The mains plug must be freely accessible so that the device can be easily and quickly disconnected from the mains power supply in an emergency. If the mains plug is inaccessible following installation, an all-pole isolating device with a contact opening of at least 3 mm must be provided in the installation.
If the device is brought into a warm environment from a cold environment, moisture may form inside the device. In this case, wait for approximately two to three hours before starting up the device.
Avoid exposing the device to dripping or splashing water. Never place objects filled with fluids, such as e.g. vases, on the device.
Keep the device dry.
If fluid nevertheless enters the device:
Immediately shut off the current supply by
removing the fuse.
Make sure that the device's current supply
cannot be unintentionally reactivated. E.g.
designate a person to prevent the fuse from being switched on.
Allow the device to dry.
Have the device checked and repaired by
trained, specialist personnel before using the device again.
Avoiding risk of explosion
Do not operate the device in an explosive environment.
Avoiding fire hazard
Make sure that the cooker top has cooled down before covering it.
A soiled device may cause fire hazards.
Keep the device in flawless condition and check it regularly.
Regularly remove any grease residues which are present. Grease residues pose a fire hazard.
Do not flambé beneath the device. Naked flames may e.g. damage neighbouring cupboards.
Only have repair work on the device carried out by personnel trained for this purpose.
In recirculated air mode:
A covered or sealed ventilation outlet may cause fire hazards. Do not place any objects such as e.g. cloths or plates on or in front of the device's ventilation slits. In the case of recirculated air devices, outflowing air must be able to escape back into the kitchen through the ventilation slits without impediments.
No objects which may impede the air flow may be installed above the device. Make sure that the outflowing air is able to flow into the kitchen without impediments.
Safety
6
The device may only be installed above a fireplace for solid fuels (e.g. coal-fired stove) if:
the fireplace has a sealed cover which cannot be
removed. Otherwise, e.g. there is an increased fire hazard due to flying sparks.
the legal and country-specific regulations are adhered to.
Avoiding risks of injury
In order to prevent the risk of falling, use a stable stepladder for all work on the device, such as e.g. replacing the filter, installing and cleaning the device.
In order to prevent risks of injury due to falling parts, use suitable mounting material.
In order to prevent cuts due to broken glass, use suitable protective gloves.
Avoiding the risk of suffocation
If the device and an open fireplace which is dependent on the room air are operated simultaneously, gases or waste gases may be drawn into the room.
Make sure that all of the permits required for operation in your country are available (e.g. those of the master chimney sweep).
Make sure that all standards and guidelines for operating the device in your country are observed.
Ensure an adequate fresh air supply in the dwelling.
Do not allow children to play with film or other parts of the packaging.
Store film or other parts of the packaging in a location which is inaccessible to children.
Preventing the risk of collapse
The necessary wall passage must be created by a specialist company. Wall passages influence the building's statics. Improperly created wall passages may lead to the collapse of the building.
Avoiding environmental damage
Dispose of the device and its accessories according to the legal regulations.
Preventing risks of poisoning
Batteries may contain poisonous substances. Keep batteries out of the reach of children. Children may place batteries in their mouths and swallow them.
Structural features of the information on dangers
The following categories of information on dangers are contained in these instructions:
DANGER
Notices containing the word DANGER warn of a hazardous situation which leads to death or severe injuries.
WARNING
Notices containing the word WARNING warn of a hazardous situation which may lead to death or severe injuries.
CAUTION
Notices containing the word CAUTION warn of a situation which may lead to slight or moderate injuries.
Safety
7
Structural features of notices regarding material or environmental damage
ATTENTION
These notices warn of a situation which leads to material or environmental damage.
Description
8
Description
The following illustrations show the way in which the possible operating modes function. The devices which are used are shown as symbols. The illustrations are intended to provide assistance. The device forms which are shown may deviate from your devices.
The device can be used to extract and clean cooking vapours.
Possible operating modes
The device is able to operate in various operating modes:
Recirculated air mode
Air extraction mode
Hybrid mode
The individual operating modes are described in the following sections.
Recirculated air mode
The device intakes room air, filters the room air and returns the cleaned room air into the room.
Cleaning is carried out in several cleaning stages. The first cleaning stage removes e.g. grease and air particles from the intaken room air. The next cleaning stage filters light, flying particles (e.g. fluff) from the intaken room air. The filter filling in the recirculating air filter neutralises existing odour contents. The odour-free, cleaned room air is returned into the room.
The filter filling must be replaced at regular intervals.
Air extraction mode
The device intakes room air, filters the room air and conducts the cleaned room air outside. Cleaning is carried out in several cleaning stages. The first cleaning stage removes e.g. grease and air particles from the intaken room air. The next cleaning stage filters light, flying particles (e.g. fluff) from the intaken room air. The cleaned room air is conducted into the open air.
Description
9
Hybrid mode
The device intakes room air, filters the room air and conducts part of the cleaned room air outside. The remaining part of the intaken air is conducted back into the room via the hybrid filter. Cleaning is carried out in several cleaning stages. The first cleaning stage removes e.g. grease and air particles from all
of the intaken room air. The next cleaning stage filters light, flying particles (e.g. fluff) from all of the intaken room air. Whilst part of the cleaned room air is conducted outside, the filter filling in the hybrid filter neutralises odour contents which are present in the remainder of the intaken room air. This odour­free, cleaned room air is returned into the room.
The filter filling must be replaced at regular intervals.
Description
10
View of the device with flap closed
1
2
3
Rotary knob (ThinCoder) Flap with lower grease tray
Lighting
Description
11
View of the device with flap open
12
3
Upper grease tray Flap with lower grease tray
"Capillar Trap"
Loading...
+ 24 hidden pages