DUT SPECIFICATIONS
Rated Voltage (Vrms)100-240
Rated Current (Arms)8-4
Rated Frequency (Hz)50-60
Rated Power (W)550
TypeATX12V
Cooling
Semi-Passive Operation✗
Cable DesignFully Modular
135mm Fluid Dynamic Bearing Fan
(SIW3-13525-HF-26)
POWER SPECIFICATIONS
Rail3.3V5V12V112V212V312V45VSB-12V
Max. Power
Amps2424
Watts130549.6153.6
Total Max. Power (W)550
18182020
30.3
45.8
CABLES AND CONNECTORS
Modular Cables
DescriptionCable CountConnector Count (Total)GaugeIn Cable Capacitors
ATX connector 20+4 pin (600mm)1118-22AWGNo
4+4 pin EPS12V (700mm)1116AWGNo
6+2 pin PCIe (600mm)2218AWGNo
SATA (550mm+150mm+150mm)1318AWGNo
SATA (550mm+150mm+150mm+150mm)1418AWGNo
SATA (550mm+150mm+150mm) / 4 pin Molex (+150mm)13 / 118AWGNo
SATA (550mm+150mm) / 4 pin Molex (+150mm+150mm)12 / 218AWGNo
FDD Adapter (+150mm)1122AWGNo
AC Power Cord (1380mm) - C13 coupler1118AWG-
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 1/8
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
RESULTS
Temperature Range (°C /°F)30-32 / 86-89.6
Average Efficiency91.159
Efficiency With 10W (≤500W) or 2% (>500W) Load -115V0.000
Average Efficiency 5VSB81.214
Standby Power Consumption (W) -115V0.0343709
Standby Power Consumption (W) -230V0.0888220
Average PF0.967
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Avg Noise Output13.27
Efficiency Rating (ETA)ETA-A
Noise Rating (LAMBDA)LAMBDA-A++
be quiet! E11-550
TEST EQUIPMENT
Chroma 6314A x2
Electronic Loads
AC SourcesChroma 6530, Chroma 61604
Power AnalyzersN4L PPA1530, N4L PPA5530
OscilloscopesPicoscope 4444 & 3424, Keysight DSOX3024A, Rigol DS2072A
VoltmeterKeithley 2015 THD 6.5 Digit
Sound AnalyzerBruel & Kjaer 2250-L G4
MicrophoneBruel & Kjaer Type 4955-A, Bruel & Kjaer Type 4189
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH
be quiet! E11-550
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/8
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSB
0.042A0.211
1
5.069V0.280115.04V
0.087A0.443
2
5.068V0.544115.05V
0.542A2.736
3
5.045V3.217115.04V
1.002A5.039
4
5.028V6.009115.04V
1.502A7.524
5
5.010V9.223115.04V
DC/AC
(Watts)
EfficiencyPF/AC Volts
75.357%
81.434%
85.048%
83.858%
81.579%
0.040
0.075
0.295
0.378
0.423
be quiet! E11-550
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSB
0.042A0.211
1
5.070V0.341230.17V
0.087A0.443
2
5.069V0.611230.17V
0.542A2.736
3
5.047V3.331230.16V
1.002A5.033
4
5.023V6.078230.17V
1.502A7.529
5
5.013V9.224230.17V
DC/AC
(Watts)
EfficiencyPF/AC Volts
0.015
61.877%
0.026
72.504%
0.129
82.137%
0.206
82.807%
0.266
81.624%
6
3.002A14.836
4.942V18.564115.04V
VAMPIRE POWER -230V
79.918%
0.480
6
3.002A14.847
80.485%
4.946V18.447230.17V
0.355
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/8
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
be quiet! E11-550
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
PAGE 5/8
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS
Test
#
1
2
3
4
5
12V5V3.3V5VSB
2.766A1.994A1.957A0.995A54.831
12.011V5.023V3.370V5.023V63.10546.39°C230.25V
6.576A2.991A2.945A1.196A109.809
12.003V5.013V3.360V5.007V120.74146.87°C230.26V
10.739A3.499A3.460A1.401A164.902
11.994V5.004V3.350V4.995V179.10047.57°C230.26V
14.903A4.006A3.948A1.603A219.785
11.985V4.993V3.339V4.984V237.90948.40°C230.26V
18.723A5.014A4.952A1.810A274.700
11.977V4.981V3.329V4.969V297.36549.12°C230.26V
DC/AC
(Watts)
Fan
Efficiency
86.889%2406.0
90.946%2406.0
92.073%2906.5
92.382%3948.9
92.378%54010.4
Speed
(RPM)
PSU Noise
(dB[A])
be quiet! E11-550
Temps
(In/Out)
38.95°C0.819
39.22°C0.923
39.60°C0.956
40.09°C0.972
40.42°C0.983
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
22.556A6.038A5.967A2.016A329.711
92.155%66514.1
11.967V4.970V3.316V4.954V357.77750.12°C230.26V
26.393A7.056A6.987A2.225A384.681
91.845%85017.4
11.958V4.959V3.305V4.939V418.83650.69°C230.26V
30.227A8.089A8.014A2.435A439.612
91.424%101225.4
11.950V4.948V3.293V4.922V480.84951.48°C230.26V
34.507A8.609A8.556A2.440A494.683
91.026%119429.5
11.942V4.938V3.284V4.915V543.45352.84°C230.26V
38.534A9.136A9.075A3.070A549.542
90.452%134932.3
11.933V4.928V3.273V4.883V607.55454.28°C230.25V
43.158A9.153A9.095A3.074A604.413
89.968%140033.5
11.926V4.919V3.265V4.877V671.80955.83°C230.26V
0.100A16.028A16.004A0.004A133.931
86.131%107025.5
11.988V4.969V3.316V5.040V155.49651.62°C230.32V
45.785A1.003A1.003A1.002A560.033
91.218%136132.4
11.942V4.953V3.300V4.980V613.94754.35°C230.26V
41.09°C0.987
41.40°C0.990
41.72°C0.992
42.72°C0.992
43.56°C0.993
44.75°C0.993
42.48°C0.949
44.09°C0.993
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 7/8
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
Anex
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)16.20
AC Loss to PWR_OK Hold Up Time (ms)14.60
PWR_OK Inactive to DC Loss Delay (ms)1.60
be quiet! E11-550
CERTIFICATIONS
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 8/8
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.