80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
Ecos ID #
Manufacturer
Model Number
Serial Number
Year
Type
Test Date
Input Voltage
Input Current
Input Frequency
Rated Output Power
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 11.94%, 50% Load)
I
PF
RMS
A
0.92 0.95 32.41% 10% 100.20 11.9/0 3.3/1.6 5.1/1.6 5.1/0.3 85.58
1.72 0.97 23.69% 20% 192.21 11.9/0.1 3.3/3.2 5.1/3.2 5.1/0.5 171.22
4.19 0.99 11.94% 50% 478.10 11.9/0.1 3.3/8 5.1/8 5.1/1.3 427.22
8.68 1.00 6.34% 100% 995.20 12/0.3 3.3/16 5/15.9 5/2.5 846.14
1200.00
1000.00
800.00
600.00
400.00
Power (Watts)
200.00
20% 50% 100%
3664
Be Quiet
Z1-850W
212s3161000094
2013
ATX12V
7/29/13
I
(%)
THD
Input and Output Power
Input Watts
Loading (% of Rated Output Power)
Load
(%)
Input
Watts
Output Watts
100-240 Volts
10-5 Amps
50-60 Hz
850 Watts
12V (cumulative of 12V1, 12V2, etc.)
89.36%
87.82%
YES
Input Current and Voltage Waveforms
200
150
100
50
0
0 0.003 0.006 0.009 0.012 0.015
-50
Voltage (V)
-100
-150
-200
DC Terminal Voltage (V)/ DC Load Current (A)
12.1/5.8
12/11.7
12/29.3
12/58.3
100%
90%
80%
70%
60%
50%
40%
Efficiency (%)
30%
20%
10%
0% 25% 50% 75% 100% 125%
Loading (% of Rated Output Power)
Time (s)
Voltage Current
Efficiency of the Power Supply
Output
Watts
Efficiency %
Efficiency
85.41%
89.08%
89.36%
85.02%
8
6
4
2
0
-2
Current (A)
-4
-6
-8
%
These tests were conducted by a third party independent testing firm on
behalf of the 80 PLUS Program. 80 PLUS is a certification program to
promote highly-efficient power supplies (greater than 80% efficiency in the
active mode) in technology applications. http://www.80plus.org/