7.0 CLEANING INSTRUCTIONS
Never immerse the base console in water.
ISOLATE FROM MAINS SUPPLY BEFORE CLEANING
1.0 The machine should be cleaned every day.
2.0 Empty filler hopper into a container and cover over for future use.
DO NOT TOP UP A HALF FULL CONTAINER.
3.0 Wash outside of filler unit and the entire lid with a mild detergent/sanitiser and hot
water.
4.0 Dismantle the pump unit at the base of the filler by removing the thumb screws (1)
that hold the pump to the chamber (2) .
5.0 Dismantle the pump chamber components as shown above and wash thoroughly.
6.0 Dry the components and reassemble the impellers (3) on the correct spindles with
the recessed side facing down.
DO NOT USE FORCE
7.0 Replace the impellor unit in the pump chamber ensuring the seal (4) is in place and
fasten with the thumb screws (1)
These screws should only be finger tight as the use of tools to over tighten could lead
to the chamber cover fracturing.
8.0 Wipe over all external surfaces with mild detergent/sanitiser and hot water.
FG053 -JAMMER 22-08-14 Rev A14