Bellcome VIDEO DOOR PHONE KIT 3.5 operation manual

4 Wires
1/2/3 Families VIDEO DOOR PHONE KIT 3.5”/7”
User manual
EN
INSTALLATION INSTRUCTIONS – VIDEO DOOR PHONE KIT
Thank you for choosing the BELLCOME products. We will assist you throughout the entire warranty period. For technical support and assistance you can contact us at ELECTRA Building Communications GmbH +43 1 810 20 99, support@bellcome.com.
KIT INSTALLATION. Follow the steps below, in the described order.
STEP 1. Read the diagrams in this brochure and the technical manuals of the KIT (VPA, VTx, SCU). STEP 2. Make the electrical connections to the terminals (ATM, VTM, VTA) and then to the VPA outdoor panel. STEP 3. Make the electrical connections of the LCK door lock and LOCK SUPPLY to the terminals of the SCU central unit and, if necessary, the connections to: the EXIT button; AUX additional installations; BAT; Vcam analog video camera. STEP 4. AUTHORIZED PERSONNEL!!! READ THE SAFETY INSTRUCTIONS FROM THE MANUAL OF THE SCU CENTRAL SUPPLY UNIT!!! DISCONNECT the fuses and make the L,N, connections to the SCU CONNECT the fuses to the power network. The , S2 LEDs turn on, and S1 turns on only if the battery (12V/max. 42Ah) is connected. STEP 5.1. PROGRAMMING THE MAIN ENTRANCE PANEL: RFID CARDS/TAGs At the SCU, long press (3 sec.) the PROG button (point 6). The PROG Red LED turns on Go to the VPA panel from the main entrance and touch each RFID CARD to the (RFID) area for one second. For each programmed RFID CARD/TAG, the panel issues two beeps. Follow the same steps for programming all the RFID CARDS/TAGs, for all the residents of the building. Return to the SCU and short press the PROG button. The Red LED turns off. The main panel keeps address 1, which
EN
is set from the factory and is ready to function. STEP 5.2. PROGRAMMING THE ADDITIONAL PANEL: NEW ADDRESS and RFID CARDS/TAGs. If the access in the building is made through two entrances, the VPA2 additional panel (point 11) from entrance 2 must be set up with address 2. At SCU 2 long press the PROG button. The PROG Red LED turns on. At the VPA2 panel, long touch the Fam.1 key (long confirmation beep), then short touch the Fam.1 key, twice. The panel confirms the storage of address 2 with two short beeps. Continue programming the CARDS/TAGs in the VPA2 panel. Each touch of the CARD/TAG to the area is confirmed by the VPA2 with two beeps. Return to the SCU2 and short press the PROG button. The Red LED turns off. The VPA2 and VPA1 panels are ready to function, with all the terminals in the building. STEP 6.1 PROGRAMMING THE ADDRESS OF THE Fam.1 TERMINAL. The terminals keep Address 1, which is set by the manufacturer. STEP 6.2 PROGRAMMING THE ADDRESS OF THE Fam.2, Fam.3 or more TERMINALS. The terminals for Family 2 will have address 2, the terminals for Family 3 will have address 3 and so on for 4, 5 etc. Program the new addresses as follows: At SCU 1 long press (3 sec.) the PROG button. The PROG Red LED turns on At the terminals for Family 2, long touch the key. The terminal confirms with one long beep. Short touch the key twice. Two short beeps are issued. The terminal stores address 2. Continue programming address 3 at Family 3 following the same steps. Long touch the key and after the long beep, short touch the key three times. Storage is confirmed with three short beeps. Return to the SCU and short press the PROG button. The Red LED turns off. The terminals are ready to function.
RECOMMENDED CABLES (point 1) Maintain the same wire colors for the same connections.
1) Max. 75 ml 4 x 0.5 mm (H03VV-F4G 0.5)
2) Max. 150 ml 4 x 0.75 mm (H05VV-F4G 0.75)
Out of electrical safety reasons, we recommend installing a grounding cable (minimum 1.00 mm – Green/Yellow) from the panel (VPM) to the central unit (SCU).
2
2
3) Max. 250 ml UTP cat5e (AWG24) or UTP cat6e (AWG23)
2
DETAILED PRODUCT CODES
VPA - advanced video outdoor panel; Product codes: 1Fam.VPA.1S(F)R02.xxy04; 2Fam.VPA.2S(F)R02.xxy04; 3Fam.VPA.3S(F)R02.xxy04; 5Fam.VPA.5S(F)R02.xxy04 (S= Surface mounting, F= Flush mounting, R= RFID CARD/TAG access)
RFID access CARD/TAG (secured at reading and copying). They are stored and can be deleted from the VPM. ATM - smart+ audio terminal; Product code: ATM.0S402.xxy04 VTM - smart+ 3.5” video terminal; Product code: VTM.3S402.xxy04 VTM/VTA - smart+/advanced 7” video terminal; Product codes: VTM.7S402.xxy04/ VTA.7S902.xxy04 VCB – Video connection box (1 video input/4 video outputs - 4 Fam.); Product code: VCB.4DN02.xxy04
1
VSB – Video selection box; Product code: VSB.4DN02.xxy04 (4 video inputs/1 video output) SCU – Central supply unit for 1 Fam; Product code: SCU.VDR02.xxy14 (110-230 Va.c., 50 Hz / 13,5 Vd.c.-2 Ad.c.). Central supply unit for 3 Fam; Product code: SCU.VDR02.xxy34 (110-230 Va.c., 50 Hz / 13,5 Vd.c.-2 Ad.c.). PSU – Additional supply unit; Product code: PSU.VDR02.xxy04 (110-230 Va.c., 50 Hz / 13,5 Vd.c.-2 Ad.c.), necessary when, due to various reasons, the supply voltage (+U, GND) at the hubs of the terminals drops below 12V. Vcam – Additional video camera connection, analogic 1Vv-v, PAL LCK/LCK – Connection of an alternating current lock (max.5Aa.c./24Va.c.), a direct current lock (max.3Ad.c./24Vd.c.) or an electromagnetic lock (max.3Ad.c./ 24Vd.c.) LOCK SUPPLY – Connection of the door lock supply (max. 24 Va.c./24Vd.c.). A direct current lock of max. 0.6Ad.c./12Vd.c. can be powered directly from the SCU by making the connections at the +U - GND connections of the VIDEO DOOR PANEL connector. NO/NCSetting of the door lock functioning. NO-Normal Open - LCK relay normal open; NC-Normal Closed - LCK relay normal closed. EXIT/EXIT – Connection of EXIT button (mounted inside the building) AUX1/AUX2 – Connection of additional installations – auto gate, garage door, outdoor lighting etc. (point 4) + BAT/- BAT – Connection of rechargeable battery DBL1/DBL2 – Connection of entrance doorbell (apartment doorbell) GONG1/GONG2 – Connection of distance call doorbell (GONG)
PARALLEL CONNECTION OF THE ADDITIONAL TERMINALS (See the diagram from point 10)
Inside the residence you can install TL additional terminals (ATM/VTM 3.5”/ VTM 7”/ VTA 7”) using the same type of cable, for the same connections (+U, C/D, GND, Vin/Vout). All the terminals in one apartment will have the address of the main terminal. For Fam.1 the terminals have address 1 set by the producer. For Fam. 2, 3 (Fam. 4, 5 or more), program the terminals with addresses 2, 3 (or 4, 5 etc.). See Step 6.2.
PARALLEL CONNECTION OF TWO OUTDOOR PANELS (See the diagram from point 11)
If the building has multiple entrances, you can install VPA outdoor panels with their own SCU central supply unit, which will command its own gate. The VPA1 main outdoor panel keeps address 1, set by the manufacturer and only the RFID access cards/tags will be programmed at the VPA1 (see Step 5.1). The VPA2 additional panel is programmed with address 2 and with the RFID access cards/tags (see Step 5.2).
EN
TROUBLESHOOTING AND SERVICE FOR THE VIDEO DOOR PHONE SYSTEM
B.
1. Normal functioning mode, without BAT: the and +U LEDs are green. The PROG and BAT LEDs are turned off.
2. Normal functioning mode, with BAT connected: the , BAT and +U LEDs are green.
3. The system functions only on battery (the installation functions correctly until the full discharge of the battery): the BAT LED is green, the and +U LEDs are turned off. Check the fuses on the SCU (FUSE T-1, 6A) and 2x6A from the network .
4. The system functions with a broken battery. The , +U LEDs are green, the BAT LED is turned off. Change the battery!
5. The outdoor panel does not function (the red LED from the outdoor panel does not blink, the call keys are not backlighted):
The , BAT and +U LEDs are green. At the SCU, the VIDEO DOOR PANEL LED is red. Check the continuity and the accuracy of the +U and GND connections from the SCU to the panel.
6. A terminal does not function (the keys are not backlighted when touched, there is no image and sound): the , BAT and +U LEDs are green. One of the OUT1, OUT2 or OUT3 LEDs is red. Check the continuity and accuracy of the +U or GND connections from the SCU to the terminal.
7. The lock does not function (LCK, LCK): check the accuracy of the connections from the SCU to the lock.
8. The display of the terminal is blue (during call, the terminal is blue, there is sound): check the continuity and accuracy of the Vin, Vout and GND connections from the outdoor panel to the video terminal.
9. The terminals are not called, the PROG LED is red: check the continuity and the accuracy of the C/D, +U and GND
connections from the outdoor panel to the video terminal.
10. The terminal for Family 2, Family 3 or with higher addresses cannot be called (The Family 1 terminal is always called): reprogram the terminal with the correct address (the number of the apartment) according to the procedure in the user manual of the terminal.
2