Belkin F5D7010CE2 User Manual

CETECOM Inc.
CETECOM Inc.
411 Dixon Landing Road, Milpitas, CA-95035, USA Phone: +1 408 586 6200 Fax: +1 408 586 6299 www.cetecom.com
Issued test report consists of 25 Pages Page 1 (25)
FCC LISTED, REG. NO.: 101450
&
RECOGNIZED BY INDUSTRY CANADA
IC – 3925
Test report no.: EMC_381EN489-17_2002
ETSI EN 301 489-17 V1.1.1 (2000-09)
(BCM94306CB)
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 2 (25)
Table of Contents
1 General information
1.1 Notes
1.2 Testing laboratory
1.3 Details of applicant
1.4 Application details
1.5 Test item
1.6 Test standards
2 Technical test
2.1 Summary of test results
2.2 Test report
1 General information
1.1 Notes
The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM Inc. USA does not assume responsibility for any conclusions and generalisations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM Inc USA.
TEST REPORT PREPARED BY: EMC Engineer: Philip Kim
1.2 Testing laboratory CETECOM Inc. 411 Dixon Landing Road, Milpitas, CA-95035, USA Phone: +1 408 586 6200 Fax: +1 408 586 6299 E-mail: lothar.schmidt@cetecomusa.com Internet: www.cetecom.com
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 3 (25)
1.3 Details of applicant
Name : Broadcom corporation
Street : 190 Mathilda Place
City / Zip Code : Sunnyvale, 94086
Country : USA
Contact : Chris McGough
Telephone : 408-922-5810
Tele-fax : 408-543-3399
e-mail : cmcgough@broadcom.com
1.4 Application details
Date of receipt of application : 2002-12-19 Date of receipt test item : 2002-11-21 Date of test : 2002-12-06, 2002-12-13 and 2002-12-14
1.5 Test item
Manufacturer : See Applicant Model No. : BCM94306CB
Description : 54g Wireless Lan cardbus PC card
Additional information Frequency : 2412MHz – 2472MHz Type of modulation : OFDM (orthognal frequency division multiplexing) Number of channels : 13 Antenna : 1dBi external antenna Power supply : From Host Output power : 16.09dBm (40.64mW) max. EIRP Extreme temp. Tolerance : 0 to +50
1.6 Test standards: ETSI EN 301 489-17 V1.1.1 (2002-09)
o
C
ETSI EN 301 489-1 V1.2.1 (2000-08)
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 4 (25)
2 Technical test
2.1 Summary of test results
No deviations from the technical specification(s) were ascertained in the course of the tests
Performed
Final Verdict:
(only “passed” if all single measurements are “passed”)
Technical responsibility for area of testing:
2003-01-10 EMC & Radio Lothar Schmidt (Manager)
Date Section Name Signature
Responsible for test report and project leader:
Passed
2003-01-10 EMC & Radio Philip Kim (EMC Engineer)
Date Section Name Signature
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 5 (25)
2.2 Test report
TEST REPORT
Test report no. : EMC_381EN489-17_2002
(BCM94306CB)
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 6 (25)
SUMMARY OF TEST RESULTS 7
EMISSION (EMI) 7
IMMUNITY (EMS) 7
GENERAL PERFORMANCE CTIRERIA 8
EMISSION TEST: 9
RADIATED EMISSIONS 9
AC LINE CONDUCTED EMISSIONS 10
HARMONIC CURRENT EMISSIONS 11
FLICKER AND VOLTAGE FLUCTUATION 12
IMMUNITY TEST: 13
RADIATED, RF ELECTROMAGNETIC FIELDS 13
RF COMMON MODE 14
ELECTROSTATIC DISCHARGE 15
FAST TRANSIENTS COMMON MODE 16
SURGES COMMON & DIFFERENTIAL MODE (1-phase) 17
VOLTAGE DIPS 18
PLOTS 19
TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS 21
PHOTOGRAPHS 24
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 7 (25)
SUMMARY OF TEST RESULTS
EMISSION (EMI)
EMI
Phenomenon
Standard Basic standard
Conducted
Interference voltage,
0.15 – 30*MHz Radiated
Interference Field
Strength
30 – 1000*MHz
Harmonic Current
Emissions
Flicker & Voltage
Fluctuation
IMMUNITY (EMS)
EMS
Phenomenon
Standard
Electrostatic
discharge
(ESD)
RF-electro-magnetic
field
Fast transients,
BURST
Surge
Transients & Surges
vehicular
evironment
RF Common mode
Vol. Dips,
interruptions &
fluctuations (AC
Power)
na=not applicable
Port Requirements EUT set-
AC Mains
Enclosure
AC mains
input port
AC mains
input port
ETSI EN 301 489-1,
2000-08
Chap. 8.4
ETSI EN 301 489-1,
2000-08
Chap. 8.2
ETSI EN 301 489-1,
2000-08
Chap. 8.5
ETSI EN 301 489-1,
2000-08
Chap. 8.6
EN 55022:1998
+Corr.2001 + A1:2000
EN 55022:1998
+Corr.2001 + A1:2000
EN 61000-3-2: 2000 na Complies Not Applicable
EN 61000-3-3: 2000 na Complies Not Applicable
Port Requirements EUT set-
Basic standard
ETSI EN 301 489-1,
Enclosure
Enclosure
Powerline
AC / DC
Powerline
(1 phase)
Powerline
(car
charger)
Powerline
AC/DC
signal lines
Input & output AC ports only
2000-08
Chap. 9.3
--
ETSI EN 301 489-1,
2000-08
Chap. 9.2
--
ETSI EN 301 489-1,
2000-08
Chap. 9.4
--
ETSI EN 301 489-1,
2000-08
Chap. 9.8
--
ETSI EN 301 489-1,
2000-08
Chap. 9.6
--
ETSI EN 301 489-1,
2000-08
Chap. 9.5
--
ETSI EN 301 489-1,
2000-08
Chap. 9.7
--
EN 61000-4-2: 1995 +A1: 1998+A2:2001
EN 61000-4-3: 1996 +A1: 1998+A2:2001
EN 61000-4-4: 1995
+A1: 2001
EN 61000-4-5: 1995
+A1: 2001
ISO 7637-1/2:1990
(12/24VDC)
EN 61000-4-6: 1996
+A1: 2001
EN 61000-4-11: 1994
+A1: 2001
Result Applicability
up
na Complies Not Applicable
na Complies Applicable
Result Applicability
up
na Complies Applicable
na Complies Applicable
na Complies Not Applicable
na Complies Not Applicable
na Complies Not Applicable
na Complies Not Applicable
na Complies Not Applicable
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 8 (25)
GENERAL PERFORMANCE CRITERIA The performance criteria are:
-performance criteria A for immunity tests with phenomena of a continuous nature;
Communication between the BCM94306CB and BCM94306MP in the form of pings should not drop during the test.
-performance criteria B for immunity tests with phenomena of a transient nature;
N/A
-performance criteria C for immunity tests with power interruptions exceeding a certain time.
N/A
NOTE: For details see subclause 6.2 ETSI EN 301 489-17
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 9 (25)
EMISSION TEST: RADIATED EMISSIONS
This test assessses the ability of ancilliary equipment to limit their internal noise from being radiated from the enclosure.
According to EMC basic standard (EN 55022)
Measurement according to EMC basic standard, but performed in the anechoic chamber with a reduced measuring distance of 3m. The reduction of the measuring distance and the existing floor absorber are corrected with the chamber factor (Method Dr. Garn, Austrian Research Centre, Seibersdorf). The test results of the anechoic chamber correspond to the 10m-OATS results
Test setup
EUT was setup in an anechoic chamber
Limits
Freq. Range
Limit (Quasi peak)
30MHz – 230MHz 30dBµV/m
230MHz – 1000MHz 37dBµV/m
EUT Type and S/N or EUT set-up no.
Plot
No.
1.1 -- 0 º - 360º h/v
Remarks: All measurements were carried out in peak mode. As long as the values stay under the average limit line No QP measurements are carried out.
receiving
antenna
directed to
Set.
angle of
turntable
polari-sation
(h / v)
comment
(e.g. operating mode or
operating mode no.)
EUT operating mode 3 Passed
result
(passed /
failed)
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 10 (25)
AC LINE CONDUCTED EMISSIONS
According to EMC basic standard (EN 55022 [7] Class-B)
1.For the table top EUT the distance to the reference ground plane (wall) should be 40 cm.
2.AC input line plugged into LISN
EUT Operating mode
Tx at middle. channel
Plot no. Powerline
(L,N)
-- L+N QP Final measurement
Note: This test does not apply due to the fact that EUT’s power is host dependant.
EUT operating mode or
operating mode no.
Detector
(Peak,
AV, QP)
Additional (scan-) information
(e.g. Pre-test Fastscan,
Maxhold,
Final measurement)
Result
(passed /
failed )
N/A
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 11 (25)
HARMONIC CURRENT EMISSIONS
This test was performed as per EMC Basic Standard EN 61000-3-2(Dec-2000)
EUT Operating mode
Tx at middle. channel
Plot No. Port EUT operating mode or
operating mode no.
-- AC input Tx at mid. channel N/A
Note: This test does not apply due to the fact that EUT’s power is host dependant.
Result
(passed / failed )
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 12 (25)
FLICKER AND VOLTAGE FLUCTUATION
This test was performed as per EMC Basic Standard EN 61000-3-3
EUT Operating mode
Tx at middle. channel
Plot No. Port EUT operating mode or
-- AC input Tx at mid. channel N/A
Note: This test does not apply due to the fact that EUT’s power is host dependant.
Result
operating mode no.
(passed / failed )
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 13 (25)
IMMUNITY TEST: RADIATED, RF ELECTROMAGNETIC FIELDS
According to EMC basic standard (EN 61000-4-3[9])
· The distance between the turn-table axis and TX-antenna is 3m.
· Field strength = 3V/m
· Start Frequency = 80MHz Stop Frequency = 1000MHz
· Frequency Step = lin 1MHz
· Modulation = AM, 1KHz, 80%
Failure Criteria
Describe applicable failure criteria for EUT
Example
1.Continuous data transfer between EUT and Mini PCI Access Point
2.Transmitting following data: 65 bytes from 192.168.1.1 icmp_seg = xxx + H = 255 time = xxx
3.If connection drops then the the program will display “Request Timed out”
Failure Criteria obesrved
Describe how failure criteria was observed
Example
1. Observe continuous scrolling “# ” on the screen
Plot
no.
5.1 vertical Front No reactions recognized passed
5.2 horizontal Front No reactions recognized passed
Antenna
Polarity
Radiation to
Reaction of the EUT
During and after test
Performance criteria A observed
Result
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 14 (25)
RF COMMON MODE
According to EMC basic standard (EN 61000-4-6[10]) Start Frequency = 150KHz Stop Frequency = 80MHz Frequency Step = 50KHz in the range of 150KHz – 5MHz 1% increment in the range of 5MHz – 80MHz Field strength = 3V/m Modulation = AM, 1KHz, 80%
Test setup
Injection via CDN or BIC clamp
Failure Criteria
Failure Criteria obesrved
Plot no.
Injection on
Injection Via Reaction of EUT during and after test Result
-- AC input power line CDN No reactions recognized N/A
Performace criteria A observed
Note: This test does not apply due to the fact that EUT’s power suuply is host dependant.
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 15 (25)
ELECTROSTATIC DISCHARGE
According to EMC basic standard (EN 61000-4-2[10])
For the table top EUT the distance to the reference ground plane should be 80 cm. Direct contact discharge on conducting surfaces of EUT Indirect air discharge on insulating surfaces of EUT ±2kV, ±4kV direct discharge & ±2kV, ±4kV, ±8KV air discharger
Test setup
Failure Criteria
Failure Criteria obesrved
10 Single impulses at each test point and for each test voltage
Contact discharge
to conducted surfaces and to coupling planes
Direct contact discharge Indirect contact discharge
Test voltage Reaction of EUT / result Reaction of EUT / result Reaction of EUT / result
+2 kV
-2 kV
+4 kV
-4 kV
+6 kV
-6 kV
+8 kV
-8 kV
Remarks: n.r.r = no reaction recognized
Performance Criteria A observed
n.r.r. passed n.r.r. passed n.r.r. passed n.r.r. passed
-
-
-
-
n.r.r. passed n.r.r. passed n.r.r. passed n.r.r. passed
-
-
-
-
Air discharge
at insulating surfaces
n.r.r. passed n.r.r. passed n.r.r. passed n.r.r. passed
n.r.r. passed n.r.r. passed
-
-
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 16 (25)
FAST TRANSIENTS COMMON MODE
According to EMC basic standard (EN 61000-4-4[11])
1.For the table top EUT the distance to the reference ground plane should be 80 cm.
2.The test level for ac mains power input ports shall be 1KV open curcuit.
Test setup
Burst on Power Line (direct injection)
Failure Criteria
Failure Criteria obesrved
Adjustment on UCS 500 M4: Trigger: "AUTO", Burst length: 15 ms
Testing on power line(direct injection)
Test
voltage
-0,5 kV
+0,5 kV
-1,0 kV
+1,0 kV
n.r.r = no reaction recognized, N/A = not applicable
repetition
frequency
5 kHz 5 kHz 5 kHz 5 kHz
L1=> GND (+=> GND)
n.r.r.
n.r.r
n.r.r.
n.r.r
reaction of the test object during and after test result
L2=> GND
N/A N/A N/A N/A
Performance Criteria A observed
Note: This test does not apply due to the fact that EUT’s power suuply is host dependant.
testing time: n 60 s for every voltage and polarity ¨ 120 s for every voltage and polarity
L3=> GND
N/A N/A N/A N/A
N => GND
n.r.r. n.r.r. n.r.r. n.r.r.
PE=> GND
N/A N/A N/A N/A
L1, N,
=>
GND
n.r.r. n.r.r. n.r.r. n.r.r.
passed passed passed passed
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 17 (25)
SURGES COMMON & DIFFERENTIAL MODE (1-phase)
According to EMC basic standard (EN 61000-4-5[14])
1.For the table top EUT the distance to the reference ground plane should be 80 cm.
2.1KV open circuit for common mode & 0.5KV open circuit for differential mode.
Failure Criteria
Failure Criteria obesrved
5 pulses for each polarity and test voltage, alternating negative/positive, triggered in case of AC-powerline: 0°, 45°, 90°, 180°, 270° referred to the line frequency (L1), repetition rate is 1 per min.
Test voltage 0°/pulse no. 1, 2 45°/no. 3, 4 90°/no. 5, 6 180°/no. 7, 8 270°/no. 9, 10
reaction of the test object during and after test by trigger angle/pulse no. (coupling on DC-lines => trigger angle not relevant)
Result
capacitive coupling on AC lines: L 1 => N or DC lines + => - (R = Ri = 2 W / C = 18 µ F )
-0,5 kV +0,5 kV
-1,0 kV +1,0 kV
-2,0 kV +2,0 kV
- kV + kV
Performance Criteria A observed
no reaction
recognized
no reaction
recognized
N/A N/A N/A N/A N/A --
N/A N/A N/A N/A N/A --
no reaction recognized no reaction recognized
no reaction recognized no reaction recognized
no reaction recognized no reaction recognized
no reaction recognized no reaction recognized
passed
passed
Note: This test does not apply due to the fact that EUT’s power suuply is host dependant.
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 18 (25)
VOLTAGE DIPS
According to EMC basic standard (EN 61000-4-11 [13])
1.For the table top EUT the distance to the reference ground plane should be 80 cm.
2.The test level shall be – a vol. Reduction of the supply vol. of 30% for 10ms; 60% for 100ms and >95% for 5000ms
Failure Criteria
Failure Criteria obesrved
for each test 3 repetitions in an interval of 10 s time for decrease or increase of supply voltage: T down/up < 5 µs (due to switching
ominal supply
voltage
U 1
100% UN:
n 230V
¨
100% UN:
n 230V
¨
100% UN:
n 230V
¨
n.r.r – no reaction recognized
Note: This test does not apply due to the fact that EUT’s power suuply is host dependant.
start by trigger
angle (AC)
0°° 10 ms
0°° 100 ms
0°° 5000 ms
duration of
test voltage
T U2 U 2
test voltage
70% U
n 161 V
N
¨
40% U
N
n 92 V
¨
0% U
N
0 V
reaction of EUT during and after
test
n.r.r – performance criteria A
observed
n.r.r – performance criteria A
observed
performance criteria C observed N/A
result
N/A
N/A
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 19 (25)
PLOTS Plot 1.1
Marker: 455.711423 MHz 33.24 dBµV/m
Level [dBµV/m]
90
80
60
40
20
0
-20 30M 50M 70M 100M 200M 300M 500M 700M 1G
Frequency [Hz]
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 20 (25)
Plot 5.1 Polarization: Vertical
Marker: 1 GHz 0 -
EUT Nogo [-]
1.5
1.0
0.5
0.0
-0.5 80M100M 200M 300M 400M 500M600M 800M 1G
Frequency [Hz]
Marker: 1 GHz 3.018376 V/m
Immunity Level [V/m]
20
15
10
5
0
80M 100M 200M 300M 400M 500M600M 800M 1G
Frequency [Hz]
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 21 (25)
Plot 5.2 Polarization: Horizontal
Marker: 1 GHz 0 -
EUT Nogo [-]
1.5
1.0
0.5
0.0
-0.5 80M100M 200M 300M 400M 500M600M 800M 1G
Frequency [Hz]
Marker: 1 GHz 2.965052 V/m
Immunity Level [V/m]
20
15
10
5
0
80M 100M 200M 300M 400M 500M600M 800M 1G
Frequency [Hz]
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 22 (25)
TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS
No Instrument/Ancillary Manufacturer Type/Model Serial No. 1A Spectrum Analyzer Rohde & Schwarz ESIB 40 100107 1B Digital Radio Comm. Tester Rohde & Schwarz CMU 200 101821 1C Harmonic / Flicker tester Voltech PMI 304644 1 Spectrum Analyzer Rohde & Schwarz FSEM 30 826880/010 2 Digital Radio Comm. Tester Rohde & Schwarz CMD 55 847958/008 5 Audio Analyzer Rohde & Schwarz UPL 16 838205/005 6 Signal Generator Rohde & Schwarz SMY02 836878/011 7 Power Meter Rohde & Schwarz NRVD 836875/020 8 10V Insertion Unit 50ohm Rohde & Schwarz URV5-Z2 836029/034 9 10V Insertion Unit 50ohm Rohde & Schwarz URV5-Z2 836029/035 10 Power Amplifier Amplifier Research 250W1000 300031 11 Power Amplifier Amplifier Research 3051G3 29254 12 Power Amplifier Amplifier Research 100A 250AM1 28835 13 Climatic Chamber Votsch VT4004 G1115 14 Programmable AC Source Chroma 6520 2098 15 LISN Rohde & Schwarz ESH 3-Z6 836154/011 16 LISN Rohde & Schwarz ESH3-Z5 836679/003 17 Vertical Coupling Plane Amplifier Research 28259 18 Immunity Tester Amplifier Research UCS 500 M4 28256 19 ESD Gun Amplifier Research 28256 20 Power Splitter Hewlett Packard 11667B 645348 21 Pre-Amplifier Miteq JS4-00102600 00616 22 Pre-Amplifier Miteq AFS4-00101 800-55-LN 23 Notch Filter-1 Weinschel System integrated 24 Notch Filter-2 Weinschel System integrated 25 Notch Filter-3 Weinschel System integrated 22 High Pass Filter Trilithic Inc. 5HC2700 9926013 23 High Pass Filter Trilithic Inc. 5HC2700 9926014 24 High Pass Filter Trilithic Inc. 4HC1600 9922307 25 High Pass Filter Trilithic Inc. 4HC1600 9922308 26 High Pass Filter-1 Weinschel System integrated --­27 High Pass Filter-2 Weinschel System integrated --­28 DC Power Supply Hewlett Packard E3610A KR83021224 29 DC Power Supply Hewlett Packard E3610A KR83023316 30 Attenuator JFW Industries 50FHE-006-200 319740 0051 31 Attenuator NARDA 776B-10 5173 32 Attenuator NARDA 770B-10 --­33 Attenuator Weinshel Corp. 1433-3 MG678 34 V-Network Rohde & Schwarz --- 836154/04 35 Reference Impd. Network Voltech IEC Standard 555 IB27/2233 36 Power Sensor Rhode & Schwarz URV5-Z2 DE30807 37 Power Sensor Rhode & Schwarz URV5-Z2 DE30808
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 23 (25)
No Instrument/Ancillary Manufacturer Type/Model Serial No.
38 Log periodic Antenna EMCO 3148 1186 39 Log periodic Antenna EMCO 3148 1187 40 Biconical Antenna EMCO 3109 0005-3250 41 Biconical Antenna EMCO 3110B 0004-3356 42 Biconical Antenna EMCO 3110B 0004-3357 43 Biconilog Antenna EMCO 3141 0005-1186
44 Horn Antenna Amplifier Research AT4002A 29068 45 Horn Antenna AH Systems SAS-200/571 325 46 Horn Antenna AH Systems SAS-200/571 326 47 Horn Antenna AH Systems SAS-200/572 141 48 Coupling Clamp 125W FCC F-2031-23mm 335 49 Coupling Clamp Amplifier Research --- 28256 50 Decoupling Clamp FCC F-2031-DCN-23mm 111 51 Calibration Fixture FCC F-2031-CF-23mm 350 52 Calibration Fixture FCC F-BCICF-4 185 53 CDN FCC FCC-801-S25 2074 54 CDN FCC FCC-801-M2-32A 2056 55 CDN FCC FCC-801-S9 2076 56 CDN FCC FCC-801-C1-BNC-50 2026 57 CDN FCC FCC-801-M3-32A 20100 58 CDN FCC FCC-801-T4 2047 59 CDN FCC FCC-801-S15 2075 60 CDN FCC FCC-801-T2 2048 61 Isotropic Field Probe Holaday HI6005 105107 62 Current Probe 10K-500M FCC F-52 105 63 Current Probe 10K-230M FCC F-120-9A 232 64 Probe Set (9K-1G) Rohde & Schwarz H2-14.1026.7744.02 832655/0013 65 Passive Impd. Adaptor FCC FCC-801-150-50CDN 20155 66 Passive Impd. Adaptor FCC FCC-801-150-50CDN 20156 67 Passive Impd. Adaptor FCC FCC-801-150-50CDN 20161 68 Passive Impd. Adaptor FCC FCC-801-150-50CDN 20162 69 Passive Impd. Adaptor FCC FCC-801-150-50CDN 20163 70 Passive Impd. Adaptor FCC FCC-801-150-50CDN 20164 71 Passive Impd. Adaptor FCC FCC-801-150-50CDN 20165 72 Passive Impd. Adaptor FCC FCC-801-150-50CDN 20166
73 Audio Box TS-SBOX Rohde & Schwarz 1119.4815.02 338968/001
74 Acoustic Calibrator Bruel & Kjaer 4231 2253349 75 Mouth Simulator Bruel & Kjaer 4227 2255310 76 Telephone test head Bruel & Kjaer 4602B 2255251 77 Probe Microphone Bruel & Kjaer 4182 1510112 78 Nexus Conditioning Ampl. Bruel & Kjaer --- 2039582
79 Microphone Bruel & Kjaer 2669 2039582 80 System Control Interface Unit Rohde & Schwarz SCIU 338802/003 81 Directional Coupler Unit Rohde & Schwarz DCU 338965/001
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 24 (25)
PHOTOGRAPHS
Radiated Immunity
Radiated Emissions
CETECOM Inc.
Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 25 (25)
ESD
Loading...