Belden RS30-1602, RS30-2402, RS20-1700, RS20-2500, RS20-0800 User Manual

...
Page 1
User Manual
RS20/RS30-...U Family (unmanaged)
LS DA
1
LS DA
2
LS DA
1
LS DA
1
FAULT
+24V(P1) 0V 0V
P FAULT
LA learn
SW2
FAULT
+24V(P1) 0V 0V
3
4
P FAULT
5
6
LA learn
SW2
7
8
9
10
11
12
13
14
15
16
17
18
RS20
+24V(P2)
ON
RS20
+24V(P2)
LS DA
ON
19
21
23
LS
1
DA
1
LS DA
1
LS DA
1
20
LS DA
22
1
24
FAULT
3
4
5
6
7
8
9
10
11
12
+24V(P1) 0V 0V
LA learn
SW2
+24V(P2)
P FAULT
ON
3
4
5
6
7
8
9
10
RS30
19
FAULT
+24V(P1) 0V 0V
P FAULT
LA learn
SW2
20
RS30
+24V(P2)
ON
11
12
13
14
15
16
RS30
+24V(P2)
ON
3
4
LS DA
1
FAULT
+24V(P1) 0V 0V
P FAULT
LA learn
SW2
3
LS DA
1
4
LS
2
5
6
7
DA
8
Installation RS20/RS30-...U
Release 03 08/2019
13
14
15
16
17
18
21
22
23
24
25
26
LS DA
2
5
6
7
8
9
10
Technical support
https://hirschmann-support.belden.com
Page 2
The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone.
© 2019 Hirschmann Automation and Control GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, translation, conversion into any electronic medium or machine scannable form is not permitted, either in whole or in part. An exception is the preparation of a backup copy of the software for your own use.
The performance features described here are binding only if they have been expressly agreed when the contract was made. This document was produced by Hirschmann Automation and Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right to change the contents of this document without prior notice. Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network components or the associated operating software. In addition, we refer to the conditions of use specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com).
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany
Installation RS20/RS30-...U 13.8.19
Page 3

Contents

Safety instructions 5
About this Manual 14
Key 14
1 Description 15
1.1 Description of the device variants 16
1.1.1 Combination options for RS20/30-...U 16
1.1.2 Number of ports and media for RS20...U 18
1.1.3 Number of ports and media for RS30...U 21
1.2 Ethernet ports 23
1.2.1 10/100 Mbit/s twisted pair port 23
1.2.2 10/100/1000 Mbit/s twisted pair port 24
1.2.3 100 Mbit/s F/O port 25
1.2.4 1000 Mbit/s F/O port 25
1.3 Display elements 26
1.3.1 Device state 26
1.3.2 Port state 27
2 Installation 28
2.1 Checking the package contents 28
2.2 Installing and grounding the device 28
2.2.1 Installing the device onto the DIN rail 29
2.3 Grounding the device 29
2.4 Installing an SFP transceiver (optional) 29
2.5 Adjust DIP switch settings 30
2.6 Connecting the terminal block 31
2.6.1 Supply voltage 31
2.6.2 “FAULT” signal contact 32
2.7 Mounting the terminal block 32
2.8 Operating the device 32
2.9 Connecting data cables 32
2.10 Filling out the inscription label 33
Installation RS20/RS30-...U
Release 03 08/2019
3
Page 4
3 Monitoring the ambient air temperature 34
4 Maintenance and service 35
5Disassembly 36
5.1 Removing the device 36
5.2 Removing an SFP transceiver (optional) 37
6 Technical data 38
A Further support 47
Installation RS20/RS30-...U
4
Release 03 08/2019
Page 5

Safety instructions

WARNING
UNCONTROLLED MACHINE ACTIONS
To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Before you start any machine which is controlled via data transmission, be sure to complete the configuration of all data transmission devices.
Failure to follow these instructions can result in death, serious injury, or equipment damage.

General safety instructions

You operate this device with electricity. Improper usage of the device entails the risk of physical injury or significant property damage. The proper and safe operation of this device depends on proper handling during transportation, proper storage and installation, and careful operation and maintenance procedures. Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.The device is free of any service components. In case of a damaged
or malfunctioning the device, turn off the supply voltage and return the device to Hirschmann for inspection.

Certified usage

Use the device solely for the application cases described in the Hirschmann product information, including this manual. Operate the device solely according to the technical specifications.
See “Technical data” on page 38.

Supply voltage

The supply voltage is electrically isolated from the housing. The devices are designed for operation with safety extra-low voltage.
Connect only SELV circuits with voltage restrictions in line with IEC/EN 60950-1 to the supply voltage connections and signal contacts.
Connect only a supply voltage that corresponds to the type plate of
your device.
Installation RS20/RS30-...U
Release 03 08/2019
5
Page 6
Ground the device before connecting any other cables.Observe the maximum values for the contact load of the signal
contact.
Relevant for North America:
The device may only be connected to a Class 2 supply voltage that fulfills the requirements of the National Electrical Code, Table 11(b). If the voltage is being supplied redundantly (two different voltage sources), the combined supply voltages must fulfill the requirements of the National Electrical Code, Table 11(b).
Relevant for North America: For use in class 2 circuits.
Use 60/75 °C (140/167 °F) or 75 °C (167 °F) copper (Cu) wire only.
Internal fuses are triggered only in the case of a detected error in the
device. In case of damage or malfunction of the device, turn off the supply voltage and return the device to the plant for inspection.
Start connecting the electrical wires only if all the above safety requirements are fulfilled.
Enable the supply voltage for the device only when the following
requirements are fulfilled:
the housing is closedthe terminal blocks are wired correctlythe terminal blocks for the power supply are connected

Grounding the device

The housing is grounded via the separate ground screw on the bottom left of the front panel.
For the ground conductor, use a wire diameter of at least 1.0 mm². Ground the device before connecting any other cables.Disconnect the grounding only after disconnecting all other cables.

Shielding ground

The overall shield of a connected shielded twisted pair cable is connected to the ground connector on the front panel as a conductor. Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
Installation RS20/RS30-...U
6
Release 03 08/2019
Page 7
Relevant for use in explosion hazard areas (Hazardous
Locations, Class I, Division 2):
Relevant for North America for devices certified for Hazardous Locations: Power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods [Article 501-4(b) of the National Electrical Code, NFPA 70] and in accordance with the authority having jurisdiction.
SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D HAZARDOUS LOCATIONS, OR NON-HAZARDOUS LOCATIONS ONLY. WARNING – EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABLE FOR CLASS I, DIVISION 2. WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS.
The USB connector is for temporary connection only. Do not use, connect, or disconnect unless area is known to be non-hazardous. Connection or disconnection in an explosive atmosphere could result in an explosion.
Peripheral equipment must be suitabel for the location it is used in. Use 60/75 °C (140/167 °F) or 75 °C (167 °F) copper (Cu) wire only.
Avertissement - Risque d'explosion - Ne pas débrancher tant que le circuit est sous tension à moins que l'emplacement soit connu pour ne contenir aucune concentration de gaz inflammable.
Avertissement - Risque d'explosion - La substitution de tout composant peut rendre ce matériel incompatible pour une utilisation en classe I, division 2.
Installation RS20/RS30-...U
Release 03 08/2019
7
Page 8
CONTROL DRAWING: Hazardous Locations Class I, Division 2, Groups A, B ,C ,D
Notes:
The nonincendive field wiring circuit concept allows interconnection of nonincendive field wiring apparatus and associated nonincendive field wiring apparatus using any of the wiring methods permitted for unclassified locations when certain parametric conditions are met.
C
a
Ci + C
Cable
; La Li + L
Cable
Nonincendive field wiring circuits must be wired in accordance with the National Electrical Code (NEC), NFPA 70 , article 501.
Nonincendive Field Wiring Parameters:
... for Class I, Division 2, Groups A,B,C,D =>
V
max
[V]
I
max
[mA]
C
i
[nF]
L
i
[µH]
Fault contacts
30 90 2.5 1.0
WARNING - EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR HAZARDOUS LOCATIONS OR EXPLOSIVE ATMOSPHERES.
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS.
DO NOT OPEN WHEN ENERGIZED.
:
CONTROL DRAWING for RS20, RS22, RS30, RS32 and RS40 Family
Size A4 Document No.: 000157671DNR Rev. 0 Date: 2011-09-21 Sheet 1 of 1
NON HAZARDOUS LOCATION
USB Port for Auto Configuration Adapter.
P1
P2
HAZARDOUS LOCATION
Fault contacts. Equipment with nonincendive field wiring parameters: V<30V I<90mA L
<1,0µH Ci<2.5nF
USB Port for Auto Configuration Adapter. For maintenance only – See Installation Instructions
USB Port for Auto Configuration Adapter. For maintenance only – See Installation
Power supply (Redundant: P1 P2) Type “P”: 48Vdc (47Vdc min. … 52Vdc max.)
Fault contacts. Equipment with nonincendive field wiring parameters: V<30V I<90mA L
i
<1,0µH Ci<2.5nF
Power supply: (Redundant: P1 P2) Type “D”: 9.6Vdc – 60Vdc
P1
P2
P1
P2
Instructions
i
Entity Parameters
Installation RS20/RS30-...U
8
Release 03 08/2019
Page 9
ATEX directive 94/9/EG – specific regulations for safe
operation
Relevant for RS20/RS30-...U devices when operating in explosive gas atmospheres according to ATEX Directive 94/9 EC, the following applies: List of standards:
EN 60079-0:2009 EN 60079-15:2010 Certificate No.: DEKRA 11ATEX0139 X.
Make sure that the device has the following label:
II 3 GEx nA IIC T4 Gc DEKRA 11ATEX0139 X
Ambient rating:
Ta: 0 °C ... +60 °C for “U” types
(item 17 of nomenclature breakdown).
The modules shall be installed in a suitable enclosure in accordance
with EN 60079-15 providing a degree of protection of at least IP54 according to EN 60529, taking into account the environmental conditions under which the equipment will be used.
When the temperature under rated conditions exceeds 70 °C at the
cable or conduit entry point, or 80 °C at the branching point of the conductors, the temperature specification of the selected cable and cable entries shall be in compliance with the actual measured temperature values.
Provisions shall be made to prevent the rated voltage from being
exceeded by transient disturbances of more than 119 V.
Connectors shall be connected or disconnected exclusively in dead-
voltage state.
DIP switches shall be switched exclusively in dead-voltage state.
The USB port shall remain disconnected.
Installation RS20/RS30-...U
Release 03 08/2019
9
Page 10

IECEx – Certification Scheme for Explosive Atmospheres

For RS20/RS30-...U devices labeled with an IECEx certificate number, the following applies:
List of standards: IEC 60079-0:2011 + Corr.2012 + Corr.2013 IEC 60079-15:2010
The equipment shall only be used in an area of not more than pollution
degree 2, as defined in IEC 60664-1.
Make sure that the device has the following label:
Ex nA IIC T4 Gc IECEx DEK 14.0077X
Ambient rating and temperature code:
T4: 0 °C ≤ Ta ≤ +60 °C for “S” types
(item 14 of nomenclature breakdown) or T4: −40 °C ≤ Ta ≤ +70 °C for “T” or “E” types (item 14 of nomenclature breakdown).
The modules shall be installed in a suitable enclosure in accordance
with IEC 60079-15 providing a degree of protection of at least IP54 according to EN 60529, taking into account the environmental conditions under which the equipment will be used.
When the temperature under rated conditions exceeds 70 °C at the
cable or conduit entry point, or 80 °C at the branching point of the conductors, the temperature specification of the selected cable and cable entries shall be in compliance with the actual measured temperature values.
Provisions shall be made to prevent the rated voltage from being
exceeded by transient disturbances of more than 119 V.
Connectors shall be connected or disconnected exclusively in dead-
voltage state.
DIP switches shall be switched exclusively in dead-voltage state. The USB port shall remain disconnected.
10
Installation RS20/RS30-...U
Release 03 08/2019
Page 11

Device casing

Only technicians authorized by the manufacturer are permitted to open the housing. Never insert pointed objects (narrow screwdrivers, wires, etc.) into the
device or into the connection terminals for electric conductors. Do not touch the connection terminals.
Keep the ventilation slits free to ensure good air circulation.
See “General technical data” on page 38.
Install the device in the vertical position.At ambient temperatures > 140 °F (60 °C):
The surfaces of the device housing may become hot. Avoid touching the device while it is operating.

Installation site requirements

When you are selecting the installation location, make sure you
observe the climatic threshold values specified in the technical data.
Operate the device at the specified ambient temperature (temperature
of the ambient air at a distance of 2 inches (5 cm) from the device) and at the specified relative humidity exclusively.
Use the device in an environment with a maximum pollution degree
that complies with the specifications in the technical data.
Install the device in a fire protected enclosure according to
EN 60950-1. If installed in a living area or office environment, the device must be operated only in switch cabinets with fire protection characteristics according to EN 60950-1.

Qualification requirements for personnel

Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the prerequisite for grounding and labeling circuits, devices, and systems in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.

National and international safety regulations

Verify that the electrical installation meets locally or nationally applicable safety regulations.
Installation RS20/RS30-...U
Release 03 08/2019
11
Page 12

CE marking

The labeled devices comply with the regulations contained in the following European directive(s):
2011/65/EU and 2015/863/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
2014/30/EU (EMC) Directive of the European Parliament and of the Council on the harmonisation of the laws of the Member States relating to electromagnetic compatibility.
In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address:
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen
The device can be used in the industrial sector.
Interference immunity: EN 61000-6-2Emitted interference: EN 55032
Warning! This is a class A device. This device can cause interference in living areas, and in this case the operator may be required to take appropriate measures.
Note: The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values.

LED or laser components

LED or LASER components according to IEC 60825-1 (2007): CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT

FCC note:

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation.
12
Installation RS20/RS30-...U
Release 03 08/2019
Page 13
Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations. These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment. The device creates and uses high frequencies and can also radiate these frequencies. If it is not installed and used in accordance with this operating manual, it can cause radio transmission interference. The use of this device in a residential area can also cause interference, and in this case the user is obliged to cover the costs of removing the interference.

Recycling note

After usage, this device must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state, and country.
Installation RS20/RS30-...U
Release 03 08/2019
13
Page 14

About this Manual

The “Installation” user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device.
Key
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
14
Installation RS20/RS30-...U
Release 03 08/2019
Page 15

1 Description

You can choose from between a wide range of variants. You have the option to set up your device individually based on different criteria:
Number of portsTransmission speedMedia typeTypes of connectorsTemperature rangeCertifications
The RS20/RS30-...U devices are designed for the special requirements of industrial automation. They meet the relevant industry standards, provide very high operational reliability, even under extreme conditions, and also long-term reliability and flexibility.
The devices allow you to set up switched industrial Ethernet networks that conform to the IEEE 802.3 standard using copper wires or optical fibers in a line structure.
The devices work without a fan.
The voltage is supplied redundantly.
The device is mounted by latching in place on a DIN rail.
Depending on the device variant, you can choose various media to connect terminal devices and other infrastructure components:
twisted pair cablemultimode F/Osinglemode F/O
The twisted pair ports support:
AutocrossingAutonegotiation Autopolarity
The Hirschmann network components help you ensure continuous communication across all levels of the company.
Installation RS20/RS30-...U
Release 03 08/2019
15
Page 16

1.1 Description of the device variants

The devices differ with regard to the number of interfaces and the media type for connecting segments.
The table below shows 2 port categories for each product variant: uplink­ports, and other ports. The table also shows for each product category the number of ports you can select, and the type of ports. In the port type column, the abbreviations F/O (optical fiber) and TP (twisted pair) designate the media type. The abbreviations DSC, ST, SFP, and RJ45 indicate the socket type.
Uplink ports Other ports
Variant NumberType Number Type
RS20-...U 2 10/100 Mbit/s,
media selectable, DSC, ST, RJ45
3 10/100 Mbit/s,
media selectable, DSC, ST, RJ45
RS30-...U 2 1000 Mbit/s,
media selectable, SFP, RJ45
4 2x100/1000 Mbit/s,
2x 100 Mbit/s, F/O, SFP
6, 14, 22 10/100 Mbit/s,
TP, RJ45
6, 14, 22 10/100 Mbit/s,
TP, RJ45
8, 16, 24 10/100 Mbit/s,
TP, RJ45
6, 14, 22 10/100 Mbit/s,
TP, RJ45
Table 1: Number and type of ports

1.1.1 Combination options for RS20/30-...U

The product designation of your device is made from combining the desired product characteristics in accordance with the following table. You will find the corresponding short designation in columns 3 and 4. You have numerous options of combining the device characteristics. You can determine the possible combinations using the configurator which is available in the Belden E-Catalog (www.e-catalog.beldensolutions.com) on the web page of the device.
Position Characteristic Ident. Ident.2 a)Property
1 to 4 Product RS20 Rail Switch without gigabit ports
RS30 Rail Switch with gigabit ports
5 - (hyphen) -
Table 2: Combination options for the RS20...U/RS30...U device variants
Installation RS20/RS30-...U
16
Release 03 08/2019
Page 17
Position Characteristic Ident. Ident.2 a)Property
6 bis 7 Number of 10/100
Mbit/s ports
08 8 × 10/100 Mbit/s Ethernet 09 9 × 10/100 Mbit/s Ethernet 16 16 × 10/100 Mbit/s Ethernet 17 17 × 10/100 Mbit/s Ethernet 24 24 × 10/100 Mbit/s Ethernet 25 25 × 10/100 Mbit/s Ethernet
8 and 9 Number of
1000 Mbit/s ports
10 and 11
a)
Uplink port(s) 1 port (Ident. column) or alternatively 2 ports (Ident.2 column)
12 and 13
a)
See items 10 and
00 0 × 1000 Mbit/s Ethernet 02 2 × 1000 Mbit/s Ethernet T1 Twisted Pair TX, RJ45
b)
M2 MM M4 NN S2 VV S4 UU L2 LL
b)
O6 OO Z6 ZZ
Multimode FX, DSC, 100 Mbit/s
b)
Multimode FX, ST, 100 Mbit/s
b)
Singlemode FX, DSC, 100 Mbit/s
b)
Singlemode FX, ST, 100 Mbit/s Singlemode Longhaul, DSC, 100 Mbit/s
c)
SFP slot, 100d)/1000 Mbit/s
c)
SFP slot, 100 Mbit/s
11
14 Temperature range S Standard: +32 °F to +140 °F (0 °C to +60
°C)
T Extended −40 °F to +158 °F (−40 °C to
+70 °C )
e)
E Extended −40 °F to +158 °F (−40 °C to
+70 °C ), Conformal Coating
d)
15 Voltage range D 9.6 V DC to 60 V DC or
18 V AC to 30 V AC
16 Approval A CE, UL508, ISA 12.12.01 (UL1604)
f)
H
CE, UL508, ISA 12.12.01 (UL1604), GL, Railway (along track), Sub Station
e)
B
CE, UL508, ISA 12.12.01 (UL1604), GL, Railway (along track), Sub Station, Hazardous Location/ATEX/IECEx
17 Software variant U Unmanaged
Table 2: Combination options for the RS20...U/RS30...U device variants
a. For device variants with 2 uplink ports you use the “Ident.” column for items 10+11 and for
items 12+13. For device variants with 3 uplink ports you use the “Ident.2” column for items 10+11 and the “Ident.” column for items 12+13. For device variants with 4 uplink ports you use the “Ident.2” column for items 10+11 and for
items 12+13. b. For RS20-0900...U, RS20-1700...U, RS20-2500...U c. In combination with “2nd uplink port” “ZZ” and “1st uplink port” “OO”. d. Only for “OO” combination e. Not when using GG or G2 transceivers. f. Without railway certification EN50155 (Train).
Installation RS20/RS30-...U
Release 03 08/2019
17
Page 18

1.1.2 Number of ports and media for RS20...U

RS20
LS DA
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
2
LS DA
1
3
5
7
4
6
8
P FAULT
ON
RS20-0800M2M2...D...U
RS20-0800M2T1...D...U
RS20
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
LS DA
1
3
5
7
4
6
8
P FAULT
ON
DA
2
LS
RS20
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
1
3
5
7
2
4
6
8
P FAULT
ON
RS20-0800T1T1...D...U
4
5
5
1
2
3
Figure 1: Device variants with 8 * 10/100 Mbit/s ports (RS20-0800...U)
1 – plug-in terminal block, 6-pin
2 – LED display elements
3 – 2-pin DIP switch
4 – ports in compliance with 10/100BASE-T(X) (RJ45 connections)
5 – port 1 + port 2, free choice of connections:
T1: Twisted-pair T(X), RJ45, 10/100 Mbit/s
M2: Multimode FX, DSC, 100 Mbit/s
M4: Multimode FX, ST, 100 Mbit/s
S2: Singlemode FX, DSC, 100 Mbit/s
S4: Singlemode FX, ST, 100 Mbit/s
L2: Singlemode Longhaul FX, DSC, 100 Mbit/s
G2: Singlemode Longhaul+ FX, DSC, 100 Mbit/s, 200 km
18
Installation RS20/RS30-...U
Release 03 08/2019
Page 19
Figure 2: Device variants with 16 * 10/100 Mbit/s ports (RS20-1600...U)
RS20
LS DA
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
2
LS DA
1
P FAULT
ON
3
5
7
9
4
6
8
10
11
13
15
12
14
16
RS20-1600M2M2...D...U
RS20-1600T1T1...D...U
RS20
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
1
3
5
7
2
4
6
8
9
11
13
15
10
12
14
16
P FAULT
ON
RS20-1600M2T1...D...U
RS20
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
LS DA
1
P FAULT
ON
3
5
7
9
4
6
8
10
11
13
15
12
14
16
2
DA
LS
4
44
5
5
1
2
3
1 to 5 – see figure 1
FAULT
+24V(P1) 0V 0V
3
4
LS DA
1
5
LS DA
5
6
7
8
9
10
11
12
13
14
P FAULT
LA learn
SW2
ON
5
2
RS20-2400M2M2...D...U RS20-2400M2T1...D...U
Figure 3: Device variants with 24 * 10/100 Mbit/s ports (RS20-2400...U)
15
17
16
18
RS20
+24V(P2)
1
2
3
RS20
FAULT
+24V(P1) 0V 0V
+24V(P2)
3
20
19
22
21
23
24
LS DA
1
4
DA
2
LS
5
7
9
11
13
15
17
4
6
LA learn
8
10
12
14
16
18
P FAULT
ON
SW2
19
20
21
22
23
24
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
+24V(P1) 0V 0V
LA learn
FAULT
P FAULT
ON
SW2
RS20
+24V(P2)
17
18
19
20
21
22
23
24
44
RS20-2400T1T1...D...U
1 to 5 – see figure 1
Installation RS20/RS30-...U
Release 03 08/2019
19
Page 20
Figure 4: Device variants with 3 uplink ports (100 Mbit/s)
RS20
+24V(P1) 0V 0V
FAULT
+24V(P2)
4
6
8
10
12
14
16
18
5
7
9
11
13
15
17
19
20
22
24
21
23
25
RS20
+24V(P1) 0V 0V
FAULT
+24V(P2)
4
6
8
10
5
7
9
11
12
14
16
13
15
17
RS20
+24V(P1) 0V 0V
FAULT
+24V(P2)
4
6
8
5
7
9
LS DA
2
LS DA
1
LS DA
3
LS DA
2
LS DA
1
LS DA
3
LS DA
2
LS DA
1
LS DA
3
LA learn
SW2
P FAULT
ON
LA learn
SW2
P FAULT
ON
LA learn
SW2
P FAULT
ON
4
44444
5
6
6
5
6
6
5
6
6
RS20-2500MMM2...D...U RS20-1700MMM2...D...U RS20-0900MMM2...D...U
1
2
3
1 to 4 – see figure 1
5 – port 3, free choice of connection:
T1: Twisted-pair T(X), RJ45, 10/100 Mbit/s
M2: Multimode FX, DSC, 100 Mbit/s
M4: Multimode FX, ST, 100 Mbit/s
S2: Singlemode FX, DSC, 100 Mbit/s
S4: Singlemode FX, ST, 100 Mbit/s
L2: Singlemode Longhaul FX, DSC, 100 Mbit/s
G2: Singlemode Longhaul+ FX, DSC, 100 Mbit/s, 200 km
6 – port 1 + port 2, free choice of connections:
MM: Multimode FX, DSC, 100 Mbit/s
NN: Multimode FX, ST, 100 Mbit/s
VV: Singlemode FX, DSC, 100 Mbit/s
UU: Singlemode FX, ST, 100 Mbit/s
Installation RS20/RS30-...U
20
Release 03 08/2019
Page 21

1.1.3 Number of ports and media for RS30...U

RS30-0802T1T1...D...U
RS30
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
3
5
7
9
4
6
8
10
P FAULT
ON
DA
2
LS
DA
1
LS
RS30-0802O6T1...D...U
RS30
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
LS DA
1
P FAULT
ON
DA
2
LS
3
5
7
9
4
6
8
10
RS30-0802O6O6...D...U
RS30
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
P FAULT
ON
LS DA
1
LS DA
2
3
5
7
9
4
6
8
10
4
5
5
1
2
3
Figure 5: Device variants with 2 * 1000 Mbit/s ports and 8 * 10/100 Mbit/s ports
(RS30-0802...U) 1 – plug-in terminal block, 6-pin 2 – LED display elements 3 – 2-pin DIP switch 4 – ports in compliance with 10/100BASE-T(X) (RJ45 connections) 5 – port 1 + port 2, free choice of connections: T1: Twisted-pair T(X), RJ45, 10/100/1000 Mbit/s O6: SX/LX, SFP slot, 1000 Mbit/s
Installation RS20/RS30-...U
Release 03 08/2019
21
Page 22
Figure 6: Device variants with 2 * 1000 Mbit/s ports and 16 * 10/100 Mbit/s ports
RS30
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
3
5
7
9
4
6
8
10
11
13
15
17
12
14
16
18
P FAULT
ON
RS30-1602T1T1...D...U
2
DA
DA
1
DA
LS
RS30-1602O6O6...D...U RS30-1602O6T1...D...U
RS30
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
P FAULT
ON
3
5
7
9
4
6
8
10
11
13
15
17
12
14
16
18
LS DA
1
2
DA
LS
RS30
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
P FAULT
ON
3
5
7
9
4
6
8
10
11
13
15
17
12
14
16
18
LS DA
1
LS DA
2
44
5
5
4
1
2
3
RS30
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
3
5
7
9
11
13
15
17
4
6
8
10
12
14
16
18
19
21
23
25
20
22
24
26
P FAULT
ON
RS30-2402T1T1...D...U
2
DA
LS
1
DA
LS
RS30-2402O6T1...D...U
RS30
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
P FAULT
ON
3
5
7
9
11
13
15
17
4
6
8
10
12
14
16
18
19
21
23
25
20
22
24
26
LS DA
1
2
DA
LS
RS30-2402O6O6...D...U
RS30
LA learn
+24V(P1) 0V 0V
FAULT
+24V(P2)
SW2
P FAULT
ON
3
5
7
9
11
13
15
17
4
6
8
10
12
14
16
18
19
21
23
25
20
22
24
26
LS DA
1
LS DA
2
44
5
5
4
1
2
3
(RS30-1602...U)
1 to 5 – see figure 5
Figure 7: Device variants with 2 * 1000 Mbit/s ports and 24 * 10/100 Mbit/s ports
22
(RS30-2402...U)
1 to 5 – see figure 5
Installation RS20/RS30-...U
Release 03 08/2019
Page 23
Figure 8: Device variants with 4 uplink ports
RS30
+24V(P1) 0V 0V
FAULT
+24V(P2)
5
7
9
11
13
15
17
19
6
8
10
12
14
16
18
20
21
23
25
22
24
26
RS30
+24V(P1) 0V 0V
FAULT
+24V(P2)
5
7
9
11
6
8
10
12
13
15
17
14
16
18
RS30
+24V(P1) 0V 0V
FAULT
+24V(P2)
5
7
9
6
8
10
LS DA
1
LS DA
2
LS DA
3
LS DA
4
LS DA
1
LS DA
2
LS DA
3
LS DA
4
LS DA
1
LS DA
2
LS
3
LS DA
4
LA learn
SW2
P FAULT
ON
DA
LA learn
SW2
P FAULT
ON
LA learn
SW2
P FAULT
ON
44 4 44
6
5
5
6
6
5
5
6
6
5
5
6
RS30-2402OOZZ...D...U RS30-1602OOZZ...D...U RS30-0802OOZZ...D...U
1
2
3
1 to 4 – see figure 5 5 – port 3 + port 4: ZZ: FX, SFP slot, 100 Mbit/s 6 – port 1 + port 2: OO: FX/SX/LX, SFP slot, 100/1000 Mbit/s

1.2 Ethernet ports

You can connect end devices and other segments to the device ports using twisted pair cables or optical fibers (F/O).

1.2.1 10/100 Mbit/s twisted pair port

This port is an RJ45 socket. The 10/100 Mbit/s twisted pair port offers you the ability to connect network components according to the IEEE 802.3 10BASE-T/100BASE-TX standard.
Autonegotiation Autopolarity Autocrossing
The socket housing is electrically connected with the front panel.
Installation RS20/RS30-...U
Release 03 08/2019
23
Page 24
Pin Function
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 RD+ Receive path 2RD− Receive path 3 TD+ Transmission path 6TD− Transmission path 4,5,7,8 —
Table 3: Pin assignment of the 10/100 Mbit/ twisted pair port, RJ-45 socket, MDI-X
mode

1.2.2 10/100/1000 Mbit/s twisted pair port

This port is an RJ45 socket. The 10/100/1000 Mbit/s twisted pair port offers you the ability to connect network components according to the IEEE 802.3 10BASE-T/100BASE­TX/1000BASE-T standard. This port supports:
Autonegotiation Autopolarity Autocrossing
Delivery state: autonegotiation active The socket housing is electrically connected with the front panel. The pin assignment corresponds to MDI-X.
Pin Function
1BI_DB+ 2BI_DB− 3BI_DA+ 4 BI_DD+ 5BI_DD− 6BI_DA− 7 BI_DC+ 8BI_DC−
Table 4: Pin assignment of 10/100/1000 Mbit/s twisted pair port, RJ45 socket,
1000 Mbit/s mode, MDI-X mode
24
Installation RS20/RS30-...U
Release 03 08/2019
Page 25

1.2.3 100 Mbit/s F/O port

In device variants RS20...U, these ports are DSC connectors or ST connectors. In device variants RS30...U, these ports are SFP slots. The 100 Mbit/s F/O port offers you the ability to connect network components according to the IEEE 802.3 100BASE-FX standard. This port supports:
Full duplex mode
Default setting: Full duplex
Note: Verify that the LH ports are connected only with LH ports, SM ports only with SM ports, and MM ports only with MM ports.

1.2.4 1000 Mbit/s F/O port

This port is an SFP slot. The 1000 Mbit/s F/O port offers you the ability to connect network components according to the IEEE 802.3 100BASE-SX/1000BASE-LX standard. This port supports:
Autonegotiation
For device variants with the designation RS30-...02OOZZ... and RS32­...02OOZZ... (4 uplink ports with SFP slot), you have the option of using either Gigabit Ethernet SFP transceivers or Fast Ethernet SFP transceivers at the two top ports, and Fast Ethernet SFP transceivers at the two bottom ports.
See “Accessories” on page 44.
Note: Verify that you connect LH ports only with LH ports, SX ports only with SX ports, and LX ports only with LX ports.
Installation RS20/RS30-...U
Release 03 08/2019
25
Page 26

1.3 Display elements

P
FAULT
After the supply voltage is switched on, the device performs a self-test.

1.3.1 Device state

These LEDs provide information about conditions which affect the operation of the whole device.
Figure 9: Device status LEDs
P - Power (green/yellow LED)
Glowing green Both supply voltages are on Glowing yellow There is only one supply voltage (P1 or P2) on Not glowing Supply voltages P1 and P2 are too low
FAULT - detected error, signal contact (red LED)
Glowing red The signal contact is open, i.e. it is reporting a detected error. Not glowing The signal contact is closed, i.e. it is not reporting
a detected error.
a
a. If the manual adjustment is active on the “FAULT” signal contact, then the detected error
display is independent of the setting of the signal contact.
Installation RS20/RS30-...U
26
Release 03 08/2019
Page 27

1.3.2 Port state

These LEDs display port-related information.
LS
1
DA
DA
1
LS
LS DA
1132
Figure 10: Port status LEDs
1 – Port status LEDs for isolated or single-row RJ45 sockets: one green and one yellow LED per port. 2 – Port status LEDs for double-row RJ45 sockets: one LED per port, glowing/flashing either green or yellow. 3 – Port status LEDs for DSC, ST, SFP
LS - link status (green LED)
Not glowing No valid connection. Lights up green Valid connection. Not glowing, and flashes
approx. every 5 seconds Glowing green, and goes out
briefly approx. every 5 seconds
DA - data (yellow LED)
Not glowing No data reception at corresponding port Flashing yellow Data reception at corresponding port
Link monitoring is enabled for the port - no valid connection
Link monitoring is enabled for the port - valid connection
Installation RS20/RS30-...U
Release 03 08/2019
27
Page 28

2 Installation

The devices have been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation.
Perform the following steps to install and configure the device:
Checking the package contentsInstalling and grounding the deviceInstalling an SFP transceiver (optional)Adjust DIP switch settingsConnecting the terminal blockMounting the terminal blockOperating the deviceConnecting data cablesFilling out the inscription label

2.1 Checking the package contents

Proceed as follows: Check whether the package includes all items named in the section
“Scope of delivery” on page 43.
Check the individual parts for transport damage.

2.2 Installing and grounding the device

WARNING
FIRE HAZARD
Install the device in a fire protected enclosure according to EN 60950-1.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
28
Installation RS20/RS30-...U
Release 03 08/2019
Page 29

2.2.1 Installing the device onto the DIN rail

Verify that the device maintains the minimum clearing in order to meet the climatic conditions:
Top and bottom device side: 3.94 in (10 cm)Left and right device side: 0.79 in (2 cm)
To mount the device onto a horizontally mounted 35 mm DIN rail according to DIN EN 60715, proceed as follows:
Slide the upper snap-in guide of the device into the DIN rail.Pull down the locking gate using a screwdriver and press the lower part
of the device against the DIN rail. Snap in the device by releasing the locking gate.
Note: The overall shield of a connected shielded twisted pair cable is connected to the ground connector on the front panel as a conductor.

2.3 Grounding the device

For the ground conductor, use a wire diameter of at least 1.0 mm². The device is grounded by the separate ground screw on the front panel.

2.4 Installing an SFP transceiver (optional)

Use only Hirschmann SFP transceivers which are suitable for usage with the device.
See “Accessories” on page 44.
Installation RS20/RS30-...U
Release 03 08/2019
29
Page 30
Proceed as follows:
LA learn
SW2
ON
Remove the protective cap from the SFP transceiver.Push the SFP transceiver with the lock closed into the slot until it latches
in.

2.5 Adjust DIP switch settings

The 2-pin DIP switch on the front panel of the device gives you the following options:
Figure 11: 2-pin DIP switch
LAlearn switch Position
ON on on OFF off off
Learn ports Link monitoring
Note: DIP switch “SW2” is not being used, so the switch setting has no effect.
State on delivery: both DIP switches “OFF”. No ports have been learned, and link monitoring is disabled on the ports. Before starting operation of the device, check whether the default settings
of the DIP switch correspond to your requirements.
30
Installation RS20/RS30-...U
Release 03 08/2019
Page 31

2.6 Connecting the terminal block

FAULT
G G
+24V(P1) 0V 0V +24V(P2)
FAULT
+24V(P1) 0V 0V +24V(P2)
+-
-+
1 1 2 2
WARNING
ELECTRIC SHOCK
Connect only a supply voltage that corresponds to the type plate of your device. Never insert sharp objects (small screwdrivers, wires, etc.) into the connection terminals for electric conductors, and do not touch the terminals. Observe the maximum values for the contact load of the signal contact.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
The supply voltage and the signal contact are connected via a 6-pin terminal block with a snap lock.

2.6.1 Supply voltage

The supply voltage can be connected redundantly. Both inputs are uncoupled. There is no distributed load. With redundant supply, the power supply unit with the higher output voltage supplies the device on its own. The supply voltage is electrically isolated from the housing.
You can choose between DC or AC voltage when connecting the supply voltage. You use the +24V and 0V pins to connect the AC voltage (see
figure 12).
Figure 12: Connecting the supply voltage at the 6-pin terminal block
With a non-redundant supply of the supply voltage, the device reports the loss of a supply voltage. You can prevent this message by changing the configuration in the Management.
Installation RS20/RS30-...U
Release 03 08/2019
1 – DC voltage, voltage range: 9.6 V DC to 60 V DC 2 – AC voltage, voltage range: 18 V AC to 30 V AC
31
Page 32

2.6.2 “FAULT” signal contact

The signal contact (“FAULT”, for pin assignment of terminal block, see
figure 12) monitors the functioning of the device, thus enabling remote
diagnostics.
The potential-free signal contact (relay contact, closed circuit) reports through a break in contact:
The detected inoperability of at least one of the two voltage supplies
(voltage supply 1 or 2 is below the threshold value).
The device is not operational.The defective link status of at least one port with active link monitoring. In
delivery state, link monitoring is inactive.
Failure of the ring redundancy reserve.Errors detected during the self-diagnostic test.
Pull the terminal block off the device and connect the power supply and
signal lines.

2.7 Mounting the terminal block

Mount the terminal block for the voltage supply and signal contact on the
front of the device using the snap lock. Verify that the snap lock latches in place.

2.8 Operating the device

By connecting the supply voltage via the terminal block, you start the
operation of the device.

2.9 Connecting data cables

In general, adhere to the following recommendations for data cable connections in environments with high electrical interference levels:
Keep the length of the data cables as short as possible. Use optical data cables for the data transmission between the buildings.
32
Installation RS20/RS30-...U
Release 03 08/2019
Page 33
When using copper cables, provide a sufficient separation between the
power supply cables and the data cables. Ideally, install the cables in
separate cable channels.
Used shielded cables (SF/UTP cables as per ISO/IEC 11801:2002).
Connect the data cables according to your requirements.
For further information see “Description of the device variants” on page 16.

2.10 Filling out the inscription label

The information field for the IP address helps you identify your device.
RS20
+24V(P2)
LS DA
1
FAULT
+24V(P1) 0V 0V
PFAULT
LA learn
ON
SW2
1
IP-ADDRESS
LS DA
2
2
Aufkleber MAC-Adresse
3
4
5
6
7
8
Figure 13: Label area for IP address of device
1 – IP address of device (label area) 2 – MAC address of device (label)
Installation RS20/RS30-...U
Release 03 08/2019
33
Page 34

3 Monitoring the ambient air temperature

Operate the device below the specified maximum ambient air temperature exclusively.
See “General technical data” on page 38.
The ambient air temperature is the temperature of the air at a distance of 2 in (5 cm) from the device. It depends on the installation conditions of the device, e.g. the distance from other devices or other objects, and the output of neighboring devices.
34
Installation RS20/RS30-...U
Release 03 08/2019
Page 35

4 Maintenance and service

When designing this device, Hirschmann largely avoided using high-wear
parts. The parts subject to wear and tear are dimensioned to last longer
than the lifetime of the product when it is operated normally. Operate this
device according to the specifications.
Relays are subject to natural wear. This wear depends on the frequency
of the switching operations. Check the resistance of the closed relay
contacts and the switching function depending on the frequency of the
switching operations.
Depending on the degree of pollution in the operating environment, check
at regular intervals that the ventilation slots in the device are not
obstructed.
Note: You will find information about the complaints and returns procedures on the Internet under
http://www.beldensolutions.com/en/Service/Repairs/index.phtml .
Installation RS20/RS30-...U
Release 03 08/2019
35
Page 36

5 Disassembly

5.1 Removing the device

WARNING
ELECTRIC SHOCK
Disconnect the grounding only after disconnecting all other cables.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Proceed as follows:
Disconnect the data cables.Disable the supply voltage.Disconnect the terminal blocks.Disconnect the grounding.Insert a screwdriver horizontally below the housing into the locking gate.Without tilting the screwdriver, pull the locking gate down and tilt the
device upwards.
Installation RS20/RS30-...U
36
Release 03 08/2019
Page 37

5.2 Removing an SFP transceiver (optional)

1
2
Proceed as follows:
Pull the SFP transceiver out of the slot by means of the opened lock.
Close the SFP transceiver with the protective cap.
Installation RS20/RS30-...U
Release 03 08/2019
37
Page 38

6 Technical data

General technical data

Dimensions W × H × D
Weight RS20-08..., RS20-09..., RS30-0802
Power supply Supply voltage
Overload current protection at input
Insulation voltage between supply voltage connections and housing
“FAULT” signal contact
Environment Storage temperature
Operating temperature
Pollution degree 2 Protection classes Laser protection Class 1 in compliance with IEC
RS20-08..., RS20-09..., RS30-0802 RS20-16..., RS20-17..., RS30-1602 RS20-24..., RS20-25..., RS30-2402
RS20-16..., RS20-17..., RS30-1602 RS20-24..., RS20-25..., RS30-2402
Rated voltage range DC Rated voltage range AC
Max. voltage range DC Max. voltage range AC
Peak inrush current < 15 A
Switching current max. 1 A, SELV Switching voltage max. 60 V DC or max. 30 V AC, SELV
(ambient air)
Humidity 10 % ... 95 %
Air pressure Up to 2000 m (795 hPa), higher
Minimum clearance around the device
Standard 0 °C ... +60 °C (+32 °F ... +140 °F) Extended −40 °F ... +158 °F (−40 °C ...
Degree of protection IP20
2.91 in. × 5.16 in. × 4.37 in. (74 mm × 131 mm × 111 mm)
4.33 in. × 5.16 in. × 4.37 in. (110 mm × 131 mm × 111 mm)
4.33 in. × 5.16 in. × 4.37 in. (110 mm × 131 mm × 111 mm)
410 g 600 g 650 g
12 V ... 48 V 24 V AC Safety extra-low voltage (SELV), redundant inputs disconnected Relevant for North America: NEC Class 2 power source max. 5A.
min. 9.6 to max. 60 V DC min. 18 to max. 30 V AC (Not applicable under UL regulations)
Non-replaceable fuse
800 V DC Protective elements limit the insulation voltage to 90 V DC (1 mA)
Standard: −40 °F ... +158 °F (−40 °C ... +70 °C ) Extended −40 °F ... +185 °F (−40 °C ... +85 °C)
(non-condensing)
altitudes on request Top and bottom device side: 3.94 in
(10 cm) Left and right device side: 0.79 in (2 cm)
+70 °C)
60825-1
a
a. Use SFP transceivers with the “EEC” extension only, otherwise the standard temperature
range applies.
Installation RS20/RS30-...U
38
Release 03 08/2019
Page 39

Dimension drawings

mm
inch
0.14
3,5
106
14
0.554.17
5.12
130
110
4.33
mm
inch
72
106
14
0.554.172.84
130
5.12
3,5
0.14
Figure 14: Dimensions of device variants RS20...U/RS30...U with 8 to max. 10 ports
Figure 15: Dimensions of device variants RS20...U/RS30...U with 16 to max. 26
ports
Installation RS20/RS30-...U
Release 03 08/2019
39
Page 40

EMC and immunity

EMC compliance – IEC/EN 61000-6-2:2005 EMI TYPE tests,
A
a)
test acc. to:
IEC/EN 61000-4-2 Electrostatic discharge
Contact discharge Air discharge
4kV 8 kV
IEC/EN 61000-4-3 Electromagnetic field
80 MHz ... 3000 MHz 10 V/m 20 V/m 20 V/m
IEC/EN 61000-4-4 Fast transients (burst)
Power line Data line
2kV 1 kV
IEC/EN 61000-4-5 Voltage surges
Power line, line / line Power line, line / ground Data line
0.5 kV 1 kV 1 kV
IEC/EN 61000-4-6 Conducted disturbances
10 kHz - 150 kHz 150 kHz ... 80 MHz
3 V 10 V
EN 61000-4-9 Pulse magnetic fields — 300 A/m 300 A/m
EMC interference emission A
a)
EN 55032 Class A Yes Yes Yes FCC 47 CFR Part 15Class A Yes Yes Yes
a)
B
8 kV 15 kV
4kV 4kV
1 kV 2kV 4kV
3 V 10 V
a)
B
a)
H
8 kV 15 kV
4kV 4kV
1 kV 2kV 4kV
3 V 10 V
a)
H
German Lloyd Classification + Construction Guidelines VI-
—YesYes
7-3 Part 1 Ed.2001
Stability A
Vibration IEC 60068-2-6 Test FC test level according
a
Yes Yes Yes
to IEC 61131-2 Germanischer Lloyd Guidelines for the
—YesYes
Performance of Type Tests Part 1 IEC 870-2-2 table 3 normal installation
—YesYes
according to EN 61850-3
Shock IEC 60068-2-27 Test Ea test level according
Yes Yes Yes
to IEC 61131-2 IEC 870-2-2 table 3 normal installation
—YesYes
according to EN 61850-3
a. Product code A: Approval = CE, UL
Product code B: Approval = CE, UL, GL, railway (trackside), Substation, HazLoc/ATEX/IECEx Produktcode H: Zulassung = CE, UL, GL, Bahn (Gleisbereich), Sub Station
B
a)
H
a)
40
Installation RS20/RS30-...U
Release 03 08/2019
Page 41

Network range

Note: The line lengths specified for the transceivers apply for the
respective fiber data (fiber attenuation and BLP/dispersion).
Product code M-SFP-...
-SX/LC... MM 850 nm 50/125 µm 0-7.5 dB 0-550 m 3.0 dB/km 400 MHz×km
-SX/LC... MM 850 nm 62.5/125 µm 0-7.5 dB 0-275 m 3.2 dB/km 200 MHz×km
-MX/LC EEC
-MX/LC EEC
-LX/LC... MM 1310 nm
-LX/LC... MM 1310 nm
-LX/LC... SM 1310 nm 9/125 µm 0-10.5 dB 0-20 km
-LX+/LC... SM 1310 nm 9/125 µm 5-20 dB 14-42 km 0.4 dB/km 3.5 ps/(nm×km)
-LH/LC... LH 1550 nm 9/125 µm 5-22 dB 23-80 km 0.25 dB/km 19 ps/(nm×km)
-LH+/LC LH 1550 nm 9/125 µm 15-30 dB 71-108 km 0.25 dB/km 19 ps/(nm×km)
-LH+/LC LH 1550 nm 9/125 µm 15-30 dB 71-128 km 0.21 dB/km
Wave length
MM 1310 nm 50/125 µm 0-12 dB 0-1.5 km 1.0 dB/km 800 MHz×km
MM 1310 nm 62.5/125 µm 0-12 dB 0-500 m 1.0 dB/km 500 MHz×km
Fiber System
attenuatio n
c
50/125 µm 0-10.5 dB 0-550 m 1.0 dB/km 800 MHz×km
c
62.5/125 µm 0-10.5 dB 0-550 m 1.0 dB/km 500 MHz×km
Example for F/O line length
a
d
Fiber attenuatio n
0.4 dB/km 3.5 ps/(nm×km)
(typically)
BLPb/ dispersion
19 ps/(nm×km)
Table 5: Fiber port 1000BASE-FX (SFP fiber optic Gigabit Ethernet Transceiver)
a. including 3 dB system reserve when compliance with the fiber data is observed b. Using the bandwidth length product is inappropriate for expansion calculations. c. With F/O adapter compliant with IEEE 802.3-2002 clause 38 (single-mode fiber offset-
launch mode conditioning patch cord) d. including 2.5 dB system reserve when compliance with the fiber data is observed
Product code M-SFP­BIDI...
Type A LX/LC EEC
Type B LX/LC EEC
Type A LH/LC EEC
Type B LH/LC EEC
Wave length TX
SM 1310 nm 1550 nm 9/125 µm 0-11 dB 0-20 km 0.4 dB/km 3.5 ps/(nm×km)
SM 1550 nm 1310 nm 9/125 µm 0-11 dB 0-20 km 0.25 dB/km 19 ps/(nm×km)
LH 1490 nm 1590 nm 9/125 µm 5-24 dB 23-80 km 0.25 dB/km 19 ps/(nm×km)
LH 1590 nm 1490 nm 9/125 µm 5-24 dB 23-80 km 0.25 dB/km 19 ps/(nm×km)
Wave length RX
Fiber System
attenuat ion
Example for F/O line length
a
Fiber attenuatio n
Dispersion
Table 6: F/O port (bidirectional Gigabit Ethernet SFP Transceiver)
a. including 3 dB system reserve when compliance with the fiber data is observed
Installation RS20/RS30-...U
Release 03 08/2019
41
Page 42
Product code M-FAST­SFP-...
-MM/LC... MM 1310 nm 50/125 µm 0-8 dB 0-5 km 1.0 dB/km 800 MHz×km
-MM/LC... MM 1310 nm 62.5/125 µm 0-11 dB 0-4 km 1.0 dB/km 500 MHz×km
-SM/LC... SM 1310 nm 9/125 µm 0-13 dB 0-25 km 0.4 dB/km 3.5 ps/(nm×km)
-SM+/LC... SM 1310 nm 9/125 µm 10-29 dB 25-65 km 0.4 dB/km 3.5 ps/(nm×km)
-LH/LC... SM 1550 nm 9/125 µm 10-29 dB 47-104 km 0.25 dB/km 19 ps/(nm×km)
-LH/LC... SM 1550 nm 9/125 µm 10-29 dB 55-140 km 0.18 dB/km
Wave length
Fiber System
attenuatio n
Example for F/O line length
a
Fiber attenuation
BLP/ dispersion
b
18 ps/(nm×km)
Table 7: Fiber port 100BASE-FX (SFP fiber optic Fast Ethernet Transceiver)
a. including 3 dB system reserve when compliance with the fiber data is observed b. with ultra-low-loss optical fiber
Product code
-M2, -MM MM 1300 nm 50/125 µm 0-8 dB 0-5 km 1.0 dB/km 800 MHz×km
-M2, -MM MM 1300 nm 62.5/125 µm 0-11 dB 0-4 km 1.0 dB/km 500 MHz×km
-S2, -VV SM 1300 nm 9/125 µm 0-16 dB 0-30 km 0.4 dB/km 3.5 ps/(nm×km)
-L2, -LL LH 1550 nm 9/125 µm 7-29 dB 24-86 km 0.3 dB/km 19 ps/(nm×km)
Wave length
Fiber System
attenuatio n
Example for F/O line length
a
Fiber attenuati on
BLP/ dispersion
Table 8: F/O port 100BASE-FX
a. including 3 dB system reserve when compliance with the fiber data is observed
MM = Multimode, SM = Singlemode, LH = Singlemode Longhaul
10/100/1000 Mbit/s twisted pair port
Length of a twisted pair segment max. 100 m (for cat5e cable)

Power consumption/power output

Device name Device model Maximum
power consumption
2 uplink ports:
RS20-0800... 2xTX port 5.3 W 18.1 Btu (IT)/h RS20-0800... 1xFX port, 1xTX port 6.5 W 22.2 Btu (IT)/h RS20-0800... 2xFX port 7.3 W 26.3 Btu (IT)/h RS20-1600... 2xTX port 9.4 W 32.1 Btu (IT)/h RS20-1600... 1xFX port, 1xTX port 10.6 W 36.2 Btu (IT)/h RS20-1600... 2xFX port 11.8 W 40.3 Btu (IT)/h RS20-2400-... 2xTX port 12.1 W 41.3 Btu (IT)/h RS20-2400-... 1xFX port, 1xTX port 13.3 W 45.4 Btu (IT)/h RS20-2400-... 2xFX port 15.5 W 52.9 Btu (IT)/h RS30-0802-... 2xTX port 8.9 W 30.4 Btu (IT)/h RS30-0802-... 1xFX port, 1xTX port 8.6 W 29.4 Btu (IT)/h RS30-0802-... 2xFX port 8.3 W 28.4 Btu (IT)/h
Power output
Table 9: Power consumption/power output RS20-...U/RS30-...U
Installation RS20/RS30-...U
42
Release 03 08/2019
Page 43
Device name Device model Maximum
power consumption
RS30-1602-... 2xTX port 13.0 W 44.4 Btu (IT)/h RS30-1602-... 1xFX port, 1xTX port 12.7 W 43.4 Btu (IT)/h RS30-1602-... 2xFX port 12.4 W 42.4 Btu (IT)/h RS30-2402-... 2xTX port 15.7 W 53.6 Btu (IT)/h RS30-2402-... 1xFX port, 1xTX port 15.4 W 52.6 Btu (IT)/h RS30-2402-... 2xFX port 15.1 W 51.6 Btu (IT)/h
3 uplink ports:
RS20-0900-... 3xFX port 9.6 W 32.8 Btu (IT)/h RS20-1700-... 3xFX port 13.7 W 46.7 Btu (IT)/h RS20-2500-... 3xFX port 16.4 W 56.0 Btu (IT)/h
4 uplink ports:
RS30-0802-... 4xFX port 12.7 W 43.3 Btu (IT)/h RS30-1602-... 4xFX port 16.8 W 57.3 Btu (IT)/h RS30-2402-... 4xFX port 19.5 W 66.5 Btu (IT)/h
Power output
Table 9: Power consumption/power output RS20-...U/RS30-...U

Scope of delivery

Device Scope of delivery
RS20-...U, RS30-...U Device
Terminal block for supply voltage and signal contact Installation user manual and CD-ROM

Order numbers/product description

The order numbers correspond to the product codes of the devices.
See “Combination options for RS20/30-...U” on page 16.
Installation RS20/RS30-...U
Release 03 08/2019
43
Page 44

Accessories

Note that products recommended as accessories may have different characteristics to those of the device, which may limit the application range of the overall system. For example, if you add an accessory with IP 20 to a device with IP 65, the IP of the overall system is reduced to 20.
Gigabit Ethernet SFP transceiver Order number
M-SFP-TX/RJ45 943 977-001 Note the following for the M-SFP-TX/RJ45 transceiver:
Can be used with:
- HiOS from software version 03.0.00
- Classic Switch Software from software version 04.1.00
- HiSecOS from software version 01.2.00 Not for use with the following devices:
- SPIDER II
- MSP/MSM
- EES
Twisted pair ports that are implemented using this transceiver have increased link failure
detection times compared to twisted pair ports that are directly available in the device.
When using this SFP transceiver, expect increased switching times with the RSTP.Cannot be used in combo ports.
M-SFP-SX/LC 943 014-001 M-SFP-SX/LC EEC 943 896-001 M-SFP-MX/LC EEC 942 108-001 M-SFP-LX/LC 943 015-001 M-SFP-LX/LC EEC 943 897-001 M-SFP-LX+/LC 942 023-001 M-SFP-LX+/ LC EEC 942 024-001 M-SFP-LH/LC 943 042-001 M-SFP-LH/LC EEC 943 898-001 M-SFP-LH+/LC 943 049-001
Bidirectional Gigabit Ethernet SFP transceiver Order number
M-SFP-BIDI Type A LX/LC EEC 943 974-001 M-SFP-BIDI Type B LX/LC EEC 943 974-002 M-SFP-BIDI Type A LH/LC EEC 943 975-001 M-SFP-BIDI Type B LH/LC EEC 943 975-002 M-SFP-BIDI Bundle LX/LC EEC (type A + B) 943 974-101 M-SFP-BIDI Bundle LH/LC EEC (type A + B) 943 975-101
Fast Ethernet SFP transceiver Order number
M-FAST SFP-TX/RJ45 942 098-001 M-FAST SFP-TX/RJ45 EEC 942 098-002 Note the following for the M-FAST SFP-TX... transceiver:
Can be used with:
- HiOS from software version 03.0.00
- On the PRP ports of the RSP devices starting with software version 02.0.01
- On the PRP ports of the EES devices starting with software version 02.0.02
- Classic Switch Software from software version 08.0.00
- HiSecOS ab Software-Version 01.2.00
Twisted-pair ports realized through this transceiver have longer link failure detection times
compared with twisted-pair ports provided by the device directly.
When using these SFP transceivers, assume a higher switching time for RSTP.Not applicable for combo ports.
44
Installation RS20/RS30-...U
Release 03 08/2019
Page 45
Fast Ethernet SFP transceiver Order number
M-FAST SFP-MM/LC 943 865-001 M-FAST SFP-MM/LC EEC 943 945-001 M-FAST SFP-SM/LC 943 866-001 M-FAST SFP-SM/LC EEC 943 946-001 M-FAST SFP-SM+/LC 943 867-001 M-FAST SFP-SM+/LC EEC 943 947-001 M-FAST SFP-LH/LC 943 868-001 M-FAST SFP-LH/LC EEC 943 948-001
Other accessories Order number
6-pin terminal block (50 pcs.) 943 845-006 Rail Power Supply RPS 30 943 662-003 Rail Power Supply RPS 80 EEC 943 662-080 Rail Power Supply RPS 120 EEC (CC) 943 662-121
Installation RS20/RS30-...U
Release 03 08/2019
45
Page 46

Underlying technical standards

Standard
EN 50121-4 Railway applications - EMC - emitted interference and interference
immunity for signal and telecommunication systems
EN 55032 Electromagnetic compatibility of multimedia equipment – Emission
Requirements
IEC/EN 60079-15 Explosive atmospheres – Part 15: Equipment protection by type of
protection “n”
EN 60950-1 Information technology equipment – Safety – Part 1: General
requirements
EN 61000-6-2 Electromagnetic compatibility (EMC) – Part 6-2: Generic standards
– Immunity for industrial environments
EN 61131-2 Programmable controllers – Part 2: Equipment requirements and
tests FCC 47 CFR Part 15 Code of Federal Regulations Germanischer Lloyd Rules for Classification and Construction VI-7-2 – GL IEC/EN 61850-3 Communication networks and systems in substations – Part 3:
General requirements IEEE 1613 IEEE Standard Environmental and Testing Requirements for
Communication Networking Devices in Electric Power Substations CSA C22.2 No. 213 Canadian National Standard(s) for Nonincendive Electrical
Equipment for Use in Class I, Division 2 Hazardous Locations Korean Register of
Shipping UL 508 Safety for Industrial Control Equipment
Rules for the Classification of Steel Ships – KR
Table 10: List of the technical standards
The device has an approval based on a specific standard only if the approval indicator appears on the device casing. If your device has a shipping approval according to Germanischer Lloyd, you find the approval mark printed on the device label. You will find out whether your device has other shipping approvals on the Hirschmann website under www.hirschmann.com in the product information. The device generally fulfills the technical standards named in their current versions.
46
Installation RS20/RS30-...U
Release 03 08/2019
Page 47

A Further support

Technical questions
For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly.
You find the addresses of our partners on the Internet at
http://www.hirschmann.com.
A list of local telephone numbers and email addresses for technical support directly from Hirschmann is available at
https://hirschmann-support.belden.com.
This site also includes a free of charge knowledge base and a software download section.
Hirschmann Competence Center
The Hirschmann Competence Center is ahead of its competitors on three counts with its complete range of innovative services:
Consulting incorporates comprehensive technical advice, from system
evaluation through network planning to project planning.
Training offers you an introduction to the basics, product briefing and user
training with certification. You find the training courses on technology and products currently available at http://www.hicomcenter.com.
Support ranges from the first installation through the standby service to
maintenance concepts.
With the Hirschmann Competence Center, you decided against making any compromises. Our client-customized package leaves you free to choose the service components you want to use.
Internet:
http://www.hicomcenter.com
Installation RS20/RS30-...U
Release 03 08/2019
47