Instructions for installation and operation
Measurement accessories
METPOINT® OCV
for the measurement in systems up to 40 bar
Dear customer,
Thank you for deciding in favour of the METPOINT® OCV measuring device with sampling probe. Please read these installation- and operating instructions carefully before mounting and starting up the METPOINT® OCV measuring device, and follow our directions. Perfect functioning of the METPOINT® OCV, and thus exact measurement and monitoring of the residual oil content in compressed air, can only be guaranteed when the provisions and notes stipulated here are strictly adhered to.
These instructions for installation and operation are a supplement to the installation and operating instructions METPOINT® OCV for the installation and operation of the measurement accessories to be applied in systems with an operating pressure of 40 bar.
The installation and operating instructions of the integrated components are not substituted by these, and they shall still be applied in their entirety. They should always be available during the operation of METPOINT® OCV in systems with an operating pressure of 40 bar.
2 Measurement accessories METPOINT® OCV 40 bar
1 Contents
1
Contents ......................................................................................................................................... 3
2
Operating conditions ...................................................................................................................... 4
2.1
Operating conditions METPOINT® OCV ........................................................................................ 4
2.2
Operating conditions ball valve 3/8“ for METPOINT® OCV ............................................................ 4
2.3
Operating conditions pressure reducer for METPOINT® OCV ....................................................... 4
3
General advice ............................................................................................................................... 5
4
Safety instructions .......................................................................................................................... 6
4.1
Safety labelling ............................................................................................................................... 6
4.2
Signal words in accordance with ANSI ........................................................................................... 6
4.3
General safety instructions ............................................................................................................. 7
4.4
Special advice for plants under pressure in accordance with the 97/23/EC Pressure Equipment
Directive.......................................................................................................................................... 8
4.5
Special safety instructions .............................................................................................................. 9
Contents
5
Field of application and proper use of the METPOINT® OCV 40 bar measurement accessories 10
6
Technical data .............................................................................................................................. 11
7
Transport and set-up .................................................................................................................... 12
8
Operating principle of the METPOINT® OCV 40 bar .................................................................... 13
9
Description structure and components ......................................................................................... 14
10
Details pressure reducer .............................................................................................................. 15
11
Installation .................................................................................................................................... 16
11.1 Mechanical installation ................................................................................................................. 16
11.2 Electrical installation / connection to the electric mains ............................................................... 16
12
Start-up ......................................................................................................................................... 16
12.1 Initial start-up ................................................................................................................................ 16
12.2 Restart .......................................................................................................................................... 16
13
Removal from service .................................................................................................................. 17
14
Maintenance ................................................................................................................................. 18
14.1 Care .............................................................................................................................................. 18
14.2 Calibration .................................................................................................................................... 18
15
Appendix....................................................................................................................................... 19
Measurement accessories METPOINT® OCV 40 bar 3
Operating conditions
2 Operating conditions
2.1 Operating conditions METPOINT® OCV
Max. permissible operating overpressure PS: 16 bar g
Working pressure compressed air: 7 bar g
Min. / max. permissible operating temperature
of the sensor unit: +5°C / +55°C
Min. / max. permissible operating temperature
of the evaluation unit: +5°C / +50°C
Min./max. ambient temperature: +5°C / +45°C
Supply voltage: 230 VAC 50 Hz
See also the separate instructions for installation and operation of the METPOINT® OCV.
2.2 Operating conditions ball valve 3/8“ for METPOINT® OCV
Max. permissible operating overpressure PS: 40 bar g
Working pressure compressed air: 38 bar g
Min. / max. permissible operating temperature: -30°C / +60°C
Min./max. ambient temperature: +5°C / +45°C
2.3 Operating conditions pressure reducer for METPOINT® OCV
Max. permissible operating overpressure PS: 40 bar g
Max. inlet pressure compressed air: 40 bar g
Max. outlet pressure compressed air: 10 bar g
Min. / max. permissible operating temperature: -30°C / +60°C
Min./max. ambient temperature: +5°C / +45°C
See also Chapter "Details pressure reducer", page 15 and Chapter "Appendix" (pressure governor), page 19.
4 Measurement accessories METPOINT® OCV 40 bar
3 General advice
Check, prior to reading the operating instructions, whether or not these instructions correspond to the device. Read these installation and operating instructions carefully prior to any intervention regarding the METPOINT® OCV in the version for the measurement in systems with an operating pressure of 40 bar. The operating instructions must be accessible at all times at the place of application of the device.
To ensure safe operation, the device must only be operated and maintained in accordance with the indications in the operating instructions. In addition, the national and operational statutory provisions and safety regulations, as well as the accident prevention regulations required for the respective case of application, need to be observed during employment. This applies accordingly when accessories are used.
Non-observance of the installation and operating instructions involves risks for persons and systems.
System performance tests, installation, setting and service measures must only be carried out by authorised skilled personnel.
General advice
In the event of improper use of the METPOINT® OCV in the version for the measurement in systems with an operating pressure of 40 bar, or in the event of non-observance of these instructions, warranty and liability claims are excluded.
If you have any queries regarding these instructions, please contact BEKO TECHNOLOGIES GMBH.
This symbol stands for actions which can also be implemented by the operators, provided that they are skilled and authorised accordingly.
Measurement accessories METPOINT® OCV 40 bar 5
Safety instructions
4 Safety instructions
In addition to these operating instructions, it is imperative to adhere to the relevant accident prevention regulations, the generally accepted safety rules, the EU directives and country-specific standards and provisions.
4.1 Safety labelling
Safety instructions whose non-observance represents a threat to life and physical condition or can lead to property damage are labelled in accordance with DIN 4844 and ANSI Z535.
Safety pictograms in accordance with DIN 4844
General danger symbol
Compressed gas
Note
Observe operating instructions
Disconnect from voltage
4.2 Signal words in accordance with ANSI
Danger!
Warning!
Imminent hazard
Serious injury or death
Potential hazard
Serious injury or death
Caution!
Notice!
Important!
6 Measurement accessories METPOINT® OCV 40 bar
Imminent hazard
Injury or property damage
Potential hazard
Injury or property damage
Additional advice, info, hints
No danger
4.3 General safety instructions
DANGER!
Compressed gas!
Risk of serious injury or death through contact with quickly or suddenly escaping compressed gas or through bursting plant components.
It is the obligation of the operator to ensure that the connected pressure generator is protected against the exceeding of the maximum operating overpressure and of the temperature limits at the METPOINT® OCV in the version for the measurement in systems with an operating pressure of 40 bar.
Make sure that the system is pressureless prior to integrating the METPOINT® OCV in the version for the measurement in systems with an operating pressure of 40 bar into the compressed gas system!
Any installation works must only be carried out on the pressureless system. Only use fittings and connecting elements that are approved for this application. It is of vital importance to observe the specifications of the respective manufacturer.
Unpressurise the plant prior to any maintenance or repair works!
Check all connections prior to the initial start-up and retighten them if necessary.
Do not exceed the max. permissible operating pressure (see type plate).
Safety instructions
The max. permissible operating overpressure is specified on the type plate and in the technical data (see "Technical data" section).
Sudden impact through pressure build-up can cause damage and escape of compressed gas.
Avoid a sudden pressure build-up by operating the valves slowly.
Maintenance, inspection and installation works must be carried out by authorised and skilled personnel only. Prior to undertaking any measures on the METPOINT® OCV in the version for the measurement in systems with an operating pressure of 40 bar, the skilled personnel shall read up on the device by carefully studying the operating instructions. The operator is responsible for the adherence to these provisions. The respective directives in force apply to the qualification and expertise of the skilled personnel.
Never make structural modifications to the plant!
Use genuine spare parts and accessories only!
The general safety and accident prevention regulations apply!
DANGER!
Supply voltage!
The operation and maintenance of electrically-powered machines and devices must only be undertaken by correspondingly qualified and authorised personnel. Prior to carrying out service measures, no matter which type, the following notes must be considered:
Make sure that no parts of the system are energised and that the METPOINT® OCV cannot be connected with the electric supply mains during service measures.
WARNING!
Unauthorised interventions!
Any modification of the components that has not been checked and approved by the manufacturer is potentially dangerous and will void any warranty and liability on the manufacturer's part.
Measurement accessories METPOINT® OCV 40 bar 7
Safety instructions
In the event of fire, do not use water to extinguish it (neither in the vicinity of the system nor directed directly at the system).
4.4 Special advice for plants under pressure in accordance with the 97/23/EC Pressure Equipment Directive
The proper use of the measuring device is the basic requirement for safe operation. Therefore, the user must proceed as follows:
The METPOINT® OCV in the version for the measurement in systems with an operating pressure of 40 bar must only be employed within the pressure and temperature range limits indicated by the manufacturer on the type plate.
No welding measures must be undertaken at the housing parts of the devices.
The maximum operating pressure indicated by the manufacturer on the type plate must not
be exceeded. It is the user's responsibility to install the appropriate safety and control devices.
The documents related to the METPOINT® OCV in the version for the measurement in systems with an operating pressure of 40 bar (manual, operating instructions, manufacturer's declaration etc.) must be kept safe for future reference.
No objects whatsoever must be installed at or placed on the METPOINT® OCV in the version for the measurement in systems with an operating pressure of 40 bar and the connecting lines.
DANGER!
High pressure!
Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or through bursting plant components.
Never make structural modifications to the plant!
Use genuine spare parts and accessories only!
WARNING!
Unauthorised intervention!
Unauthorised interventions may endanger persons and plants and lead to malfunction.
Unauthorised interventions, modification and abuse of the pressure devices are prohibited. User of the devices must observe the local and national pressure equipment regulations in the country of installation.
8 Measurement accessories METPOINT® OCV 40 bar