Beko LG-BKE4500 D, LG-BKE 4600 D, LG-BKE 4450 D, LG-BKE 4700 D, LG-BKE 5605 D User Manual

...
Page 1
Room Air Conditioner
OWNER'S MANUAL
• Please read carefully and thoroughly this manual before operating this unit.
• Contact the authorized SVC man for repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• Young children should be supervised to ensure that they do not play with the appliance.
Prior to installation, this air-conditioning unit must be submitted for approval by the utility service which provides electricity (EN 6055-3 Norm).
Models :
LG-BKE 4450 D - LG-BKE 5455 D LG-BKE 4500 D - LG-BKE 5505 D LG-BKE 4600 D - LG-BKE 5605 D LG-BKE 4700 D - LG-BKE 4800 D
Page 2
2
Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips
WARNING
WARNING
WARNING
WARNING
CAUTION
CAUTION
WARNING
WARNING
Safety precautions
Safety Precautions
Warning ................................2
Caution .................................3
Operating Instructions
Preparation before operation
..4
About the Remote Control on
the System............................5
Operation Mode Selection
Button....................................6
Care and Maintenance
Care and Maintenance .......13
Operation Tips ....................14
Troubleshooting tips
Before You
Call For Service...............15
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring of instruction will cause harm or damage, the seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Plug in the power plug properly.
Otherwise,itwillcause electrical shock or fire due to heat generation.
Do not operate or stop the unit by inserting or pulling out the power plug.
It will cause electrical shock or fire due to heat generation.
Do not damage or use an unspecified power cord.
It will cause electrical shock or fire.
If the supply cord is damaged, it
must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
Do not modify power cord
length or share the outlet
with other appliances.
It will cause electrical shock or fire due to heat generation.
Do not operate with wet hand.
It may cause electrical shock.
Do not insert anything into the air inlet/air outlet.
Since the fan rotates at high speed, this may cause an injury or damage the unit.
Do not expose the skin directly to cool air for long periods of time.
This could damage your health.
When anabnormality (smell of burning, etc) occurs, stopthe air conditioner, and disconnect the powerplug or turn off the breaker.
If the unit continues to be operated in an abnormal condition, it may cause a fire, damage, etc. In this case, consult your dealer.
Repair or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.
Do not install, remove and reinstall the unit by yourself.
Improper installation will cause water leakage, electrical shock, or fire. Please consult authorized dealer or specialist for the installation work. Please note fault caused by improper installation is not covered by warranty.
Unit must be installed in an easily accessible area. Any additional cost required to hire a special equipment to service the unit will be the responsibility of the customer.
Installation precautions
Page 3
3
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips
CAUTION
CAUTION
When the air filter is to be
removed, do not touch the
metal parts of the indoor unit.
It may cause an injury.
Should be disconnected from
supply
Do not clean the air
conditioner with water.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
Ventilate well when used
together with a stove, etc.
An oxygen shortage may occur.
Contact the authorized Service technician for repair or maintenance of this unit.
Contact the installer for installation of this unit.
The air conditioner is not intended for use by young children or infirm persons
without supervision.
Young children should be supervised to ensure that they do not play with the air conditioner.
CAUTION
When the unit is to be
cleaned, switch off, and turn
off the circuit breaker.
Since the fan rotates at high speed during operation, it may cause an injury.
Do not put a pet or house
plant where it will be
exposed to direct air flow.
This could injure the pet or plant.
Do not leave on installation
stand which is damaged.
The unit may drop or fall down and cause an injury.
Do not apply an insecticide
or flammable spray.
It may cause a fire or deformation of the cabinet.
Do not put a stove, etc.
where is exposed to direct
air flow.
It may affect combustion.
Do not step on the
indoor/outdoor unit and do
not put anything on it.
It may cause an injury through dropping or falling down.
Do not insert hands through
vanes when the air conditioner
is operationg
It will cause an injury by the rotating blower.
When the unit is not going to
be used for a long time, turn
off the circuit breaker.
If not, dirt may collect and cause a fire.
Do not step onto an unstable
bench when cleaning and/or
maintaining the unit.
It may cause an injury, etc. by falling down.
Do not use for special
purposes.
Do not use this air conditioner to preserve precision devices, food, animal, plants, and art objects. It may cause deterioration of quality, etc.
Do not operate for a long time in
high humidity, e.g. leaving a
door or window open.
Inthecoolingmode,ifitis operatedinaroomwithhigh humidity (80%RH or more) for a long time, water condensed in the air conditioner may drop and may wet and spoil furniture, etc.
Page 4
4
Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips
Signal
receptor
Operation indication lamps
Preparation before operation
Storage and Tips For Using the Remote Control
Theremotecontrolmaybestoredmountedona wall.
To operate the room air conditioner, aim the remote control at the signal receptor.
How to Insert the Batteries
Remove the battery cover by pulling it according to the arrow direction.
Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
Reattach the cover by sliding it back into position.
NOTES:
• Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries.
Signal Receptor
Receives the signals from the remote controller. (Signal receiving sound:two short beeps or one long beep.)
Operation Indication Lamps
On/Off : Lights up during the system operation. OFF Timer :Lights up during indoor unit operation.
Defrost Mode : Lights up during Defrost Mode or Hot Start operation.
(Heat pump model only)
ON
Indoor Unit
Operation
:Lights up during indoor unit operation.
Page 5
TEMP.
TIME
OFF
hr.
5
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips
4
1
2
5
6
8
3
7
About the remote control on the system
Features of the Remote Control
OPERATION DISPLAY
Displays the operation conditions.
AIRFLOW DIRECTION START/STOP BUTTON
Used to stop or start louver movement and set the desired up/down airflow direction.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
OFF TIMER BUTTON
Used to set the time of stopping operation.
START/STOP BUTTON
Operation starts when this button is pressed, and stops when the button is pressed again.
ROOM TEMPERATURE SETTING BUTTONS
INDOOR FAN SPEED SELECTION BUTTON
JET COOL
Used to start or stop the speed cooling. (Speed cooling operates super high fan speed in cooling mode.)
1
2
3
4
5
6
7
8
Signal transmitter
Transmits the signals to the room air conditioner.
Remote Controller
Page 6
TIME
OFF
hr.
TEMP.
6
Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips
Cooling Operation
Healthy Dehumidifacation Operation
Heating Operation
Cooling Operation
(Cooling Model)
(Heat pump Model)
Healthy Dehumidifacation Operation
1
3
2
4
Features of the Remote Control
(1) OPERATION MODE
(2) OPERATION PROCEDURE
Operation Mode Selection button
1st
2nd
3
rd
4th
Start/Stop Button
Operation Mode Selection Button
Room Temperature Setting Button
Indoor Fan Speed Selection Button
Page 7
TIME
OFF
hr.
TEMP.
7
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips
TEMP.
TIME
OFF
hr.
TIME
OFF
hr.
TEMP.
TIME
OFF
hr.
TEMP.
TIME
OFF
hr.
TEMP.
TIME
OFF
hr.
TEMP.
Cooling
Healthy
Dehumidification
Heating
(Heat pump model only)
To raise the temperature
To lower the temperature
TEMP.
TIME
OFF
hr.
TIME
OFF
hr.
TEMP.
Cooling
Healthy
Dehumidification
Beep, Beep
Press the Start/Stop Button.
Select Cooling Operation. Press the Operation Mode Selection Button. Each time the button is pressed, the operation mode is shifted in the arrow direction.
Set the temperature lower than the room temperature.
Thetemperaturecanbesetwithinarangeof18°C~30°C by 1°C.
Set the fan speed.
Select the fan speed in four steps-low, medium, high or CHAOS.
Each time the button is pressed, the fan speed mode is shifted.
The display shows high fan speed.
Cooling Operation
1
2
3
4
Natural wind by the CHAOS logic
For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to
CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.
Beep, Beep
Page 8
TIME
OFF
hr.
8
Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips
TEMP.
TIME
OFF
hr.
TIME
OFF
hr.
TEMP.
TIME
OFF
hr.
TEMP.
Cooling
Healthy
Dehumidification
Heating
(Heat pump model only)
Beep, Beep
TEMP.
TIME
OFF
hr.
TIME
OFF
hr.
TEMP.
Cooling
Healthy
Dehumidification
Press the Start/Stop Button.
Select Healthy Dehumidification Operation. Press the operation Mode Selection Button.
Each time the button is pressed, the operation mode is shifted in the arrow direction.
You can select the fan speed in four steps-low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted.
Healthy Dehumidification Operation Mode
This mode dehumidifies without overcooling.
1
2
3
During Healthy Dehumidification Operation:
If you select the dehumidification mode on the operation selection button, the airconditioner starts to
run the dehumidification function, automatically setting the room temp. and airflow volume to the best condition for dehumidification based on the sensed current room temp.
In this case, however, the setting temp. is not displayed in the remote control and you are not able to control the room temp. either.
During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status and makes the room condition healthy and comfortable even in the high humidity season.
Beep, Beep
Page 9
9
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips
Beep, Beep
TIME
OFF
hr.
TEMP.
TEMP.
TIME
OFF
hr.
TIME
OFF
hr.
TEMP.
TEMP.
TIME
OFF
hr.
TIME
OFF
hr.
TEMP.
TIME
OFF
hr.
TEMP.
Cooling
Healthy
Dehumidification
Heating
(Heat pump model only)
To raise the temperature
To lower the temperature
Press the OFF Time Button.
1. Press the OFF Time Button.
2. Check the OFF Time LED of the room air conditioner.
3. The Timer is programmed by 1 hour each pressing the OFF Time button from 1 hour to 7 hours.
OFF Timer control Setting
OFF TIMER CONTROL SETTING
Press the Start/Stop button. The unit will respond with a beep.
To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Set the temperature higher than the room temperature. The temperature can be set within a range of 16°C~30°Cin 1°C increments.
Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps–low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted.
Heating Operation(Heat pump model only)
1
2
3
4
TIME
hr.
Beep, Beep
Page 10
10
Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips
or
or
or
TIME
OFF
hr.
TEMP.
NOTE:
During the JET COOL function at any moment, the A/C starts to blow the cool air at
extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. in the shortest time in a hot summer.
In heat pump mode the JET COOL function is not available. In order to return to the normal cooling mode from the JET COOL mode, you just press
either the operation mode selection button, airflow volume selection or temp. setting button or the JET COOL button again.
Press the Start/Stop button. The unit will respond with a beep.
Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes.
To cancel the Jet Cool mode, press the Jet Cool button again or the fan speed button or the room temperature setting button and the unit will operate in high fan speed on cooling mode.
Jet Cool Operation
1
2
3
TIME
hr.
Page 11
11
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips
Press the Start/Stop Button. (Confirm the unit on operation.)
Press the Airflow Direction Control Button and the vertical louvers swing up and down automatically.
Press again the Airflow Direction Control Button to set the vertical louver at the desired airflow direction.
Caution
Always use the remote controller to adjust the airflow direction. Manually moving the vertical airflow direction louver by hand could cause operation errors.
When air conditioner operation is stopped, the vertical airflow direction louver will close the air outlet vent of room air conditioner.
Horizontal Airflow Direction Control (Optional)
Adjust the horizontal airflow direction by manually moving the horizontal airflow direction louver by hand.
Airflow Direction Procedure
Airflow Direction Control
The airflow direction can be adjusted as desired by using the remote controller. This is effective when you want to cool yourself directly, such as after taking a bath.
1
2
3
Page 12
Power
button
Open the front panel upward
Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips
12
Operation procedures when the remote control can't be used. The operation will be started if the power button is pressed. If you want to stop operation, re-press the button.
Forced Operation
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. So there is no need of activating this function by pressing any key or button. In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later. As
Additionally, in order to cancel auto restart operation press power button let it be pressed for about 6 seconds. To operate auto restart operation again, press power button for about 6 seconds as well.
the compressor starts, the fan speed also resumes its previous setting mode.
Heat pump Model
Cooling Model
Room Temp. 24°C 21°C Room Temp. < 24°C Room Temp. < 21°C
Operating mode Cooling Cooling Healthy Dehumidification Heating
Indoor FAN Speed
High High High High
Setting Temperature
22°C22°C23°C24°C
Helpful information
Fan speed and cooling capacity. The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool the room quickly.
High
Speed
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes. During test operation, if remote controller signal is received, the unit operates as remote controller sets. If you want to use this operation, open the front panel upward and Press the power button let it be pressed for about 3 seconds. If you want to stop the operation, re-press the button.
Page 13
13
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips
G
a
s
o
l
i
n
e
P
o
w
d
e
r
(Side)
(Rear)
Air intake vents
Air outlet vents
Piping Drain Hose
Vertical louver
Horizontal louver
Air filters
(behind front panel)
Air outlet vent
Air inlet vent
Care and maintenance of the air conditioner
CAUTION: Before performing any maintenance, turn off the main power to the system.
Indoor Unit
Grille, Case, and Remote Control
Turn the system off before cleaning. To
clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
NOTE:
Supply power must be disconnected before cleaning the indoor unit.
AIR FILTERS
The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary.
Never use any of the followings:
Water hotter than 40°C Could cause deformation and/or discoloration.
Volatile substances Could damage the surfaces of the air conditioner.
Lift the front access panel and pull the filter tab slightly forward to remove the filter.
Clean the filter with a vacuum or warm, soapy water.
If dirt is conspicuous, wash with a solution of detergent in lukewarm water.
If hot water (40°C or more) is used, it may be deformed.
After washing with water, dry well in the shade.
Re-install the air filter.
1
2
3
4
Outdoor Unit
The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned.
NOTE:
Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.
Page 14
14
CAUTION
Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips
When air conditioner is not going to be used for a long time.
When the air conditioner is to be used again.
Turn off the circuit breaker, and disconnect the plug.
Remove the batteries from the remote control.
Whentheairconditionerisnotgoingtobeusedforalongtime.
Turn off the circuit breaker when the air conditioner is not going to be used for a long time.
Dirt may collect and may cause a fire.
Clean the air filter and install it in the indoor unit. (Refer to page 13 for cleaning filters.)
Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
Do not overcool the room.
This is not good for the health and wastes electricity.
Make sure that the doors and windows are shut tight.
Avoid opening doors and windows as much as possible to keep the cool air in the room.
Keep blinds or curtains closed.
Do not let direct sunshine enter the room when the air conditioner is in operation.
Clean the air filter regularly.
Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects. Clean at least once every two weeks.
Keep the room temperature uniform.
Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room.
Ventilate the room occasionally.
Since windows are kept closed, it is a good idea to open them and ventilate the room now and then.
Operation Tips
Page 15
15
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips
?
Before you call for service...
Check the following points before requesting repairs or service.... If the fault persists, please
contact your dealer or service center.
Troubleshooting Tips! Save time and money!
Case Explanation See page
The air conditioner does not operate.
The room has a peculiar odor.
It seems that condensation is leaking from the air conditioner.
Air conditioner does not operate for about 3 minutes when restarted.
Does not cool or heat effectively.
The air conditioner operation is noisy.
Remote control display is faint, or no display at all.
Crack sound is heard.
Have you made a mistake in timer operation?
Has the fuse blown or has the circuit breaker
been tripped?
Check that this is not a damp smell exuded by the walls, carpet, furniture, or cloth items in the room.
Condensation occurs when the airflow from the air conditioner cools the warm room air.
This is the protector of the mechanism.
Wait about three minutes and operation will
begin.
Is the air filter dirty? See air filter cleaning instructions.
Has the temperature been set incorrectly?
Are the indoor unit's air inlet or outlet vents
obstructed?
For a noise that sounds like water flowing.
-This is the sound of freon flowing inside the
air conditioner unit.
For a noise that sounds like the compressed air releasing into atmosphere.
-This is the sound of the dehumidifying water
being processed inside the air conditioning unit.
Are the batteries depleted?
Are the batteries inserted in the opposite (+)
and (-) directions?
This sound is generated by the expansion/constriction of the front panel, etc. due to changes of temperature.
-
-
-
-
13
7
-
-
4
-
NOTE
WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT.
The indoor side is not water resistant and should not be exposed to excess water.
Loading...