Behringer MS-1-BK, MS-1-BU, MS-1-RD MS-1-BK, Calibration

Synthesizers and Samplers
MS-1-BK / MS-1-BU / MS-1-RD
Analog Synthesizer with 32 Full-Size Keys, 3340 VCO with 4 Simultaneous Waveforms, VCF, NovaMod FM Sources, 32-Step Sequencer, Arpeggiator and Live Performance Kit
User Support Bulletin
Introduction
The unit is carefully calibrated at the factory. The performance may change over time or due to environmental changes, and the following recalibration procedures can be used to bring it back to its factory settings.
Equipment required
1. A multimeter (with 1 mv resolution)
2. A 3.5 mm cable (mono or stereo should be ne)
985-40000-01104 Rev.A 2021-02-03
Condential, for internal use only. Not to be reproduced.
page 1 of 5
Synthesizers and Samplers
MS-1-BK / MS-1-BU / MS-1-RD
Preparation
Make sure your MS-1 has been powered on for at least 30 minutes, and that it is situated in a place where the temperature will not change drastically during calibration.
Remove all unused cables from the MS-1.
Set the controls 1 to 8 to the position shown in the right hand column of this table. Set all the other faders, knobs and switches shown in the photo.
4
2
1
3
No. Control Set to
1 LFO RATE M
2 WAVE FORM
3 GLIDE M
4 RANGE 2’
5 MAIN
6 SUB OSC 2 OCT DOWN
7 VCA GAT E
8 ENVELOPE GAT E
5 6
7
8
Calibration Procedure
Follow all steps in the order in which they are presented.
No. CV type Description
1 Internal CV Calibrates the internal CV
2 Output CV Tunes the CV output
3 External CV Compensate oscillator oset for external CV in
page 2 of 5page 2 of 5
Loading...
+ 3 hidden pages