Your Beha-Amprobe product will be free from defects in material
and workmanship for three years from the date of purchase unless
local laws require otherwise. This warranty does not cover fuses,
disposable batteries or damage from accident, neglect, misuse,
alteration, contamination, or abnormal conditions of operation
or handling. Resellers are not authorized to extend any other
warranty on the behalf of Beha-Amprobe. To obtain service during
the warranty period, return the product with proof of purchase
to an authorized Beha-Amprobe Service Center or to an BehaAmprobe dealer or distributor. See Repair Section for details. THIS
WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES
- WHETHER EXPRESS, IMPLIED OR STATUTORY - INCLUDING
IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR
MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER
SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE
OR THEORY. Since some states or countries do not allow the exclusion
or limitation of an implied warranty or of incidental or consequential
damages, this limitation of liability may not apply to you.
Repair
All Beha-Amprobe tools returned for warranty or non-warranty
repair or for calibration should be accompanied by the following:
your name, company’s name, address, telephone number, and proof
of purchase. Additionally, please include a brief description of the
problem or the service requested and include the test leads with
the meter. Non-warranty repair or replacement charges should be
remitted in the form of a check, a money order, credit card with
expiration date, or a purchase order made payable to Beha-Amprobe.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before
requesting repair. During the warranty period, any defective test tool
can be returned to your Beha-Amprobe distributor for an exchange
for the same or like product. Please check the “Where to Buy”
section on beha-amprobe.com for a list of distributors near you.
Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Beha-Amprobe
distributor for a nominal charge. Please check the “Where to Buy”
section on beha-amprobe.com for a list of distributors near you.
Beha-Amprobe
Division and reg. trademark of Fluke Corp. (USA)
* United Kingdom
Germany
In den Engematten 14 52 Hurricane Way
79286 GlottertalNorwich, Norfolk
Germany NR6 6JB United Kingdom
The Netherlands - Headquarters
Science Park Eindhoven 5110
5692 EC Son
The Netherlands
Phone: +31 (0) 40 267 51 00
beha-amprobe.com
*(Correspondence only – no repair or replacement available from this address.
European customers please contact your distributor.)
**single contact address in EEA Fluke Europe BV
**
AM-500-EUR Digital Multimeter
4
7
8
1
32
5
6
1
LCD Display
2
SELECT Button
5
Input Terminal for voltage, diode, resistance and
continuity measurement
6
Input Terminal for battery test and AC/DC mA or μA
MAINTENANCE AND REPAIR .............................................14
BATTERY AND FUSE REPLACEMENT .................................. 15
1
SYMBOLS
Caution ! Risk of electric shock.
Caution! Refer to the explanation in this Manual
Alternating Current (AC)
Direct Current (DC)
The equipment is protected by double insulation
or reinforced insulation
Earth (Ground)
Audible tone
Battery
Complies with European Directives
Conforms to relevant Australian standards
Canadian Standards Association (NRTL/C)
Do not dispose of this product as unsorted
municipal waste. Contact a qualified recycler.
SAFETY INFORMATION
The Meter complies with:
IEC/EN 61010-1 3rd Edition, UL61010-1 2nd Ed. and CAN/
CSA-C22.2 No. 61010-1-04 + CSA Update No.1: 2008 to
Category III 600 Volts, Pollution degree 2
IEC/EN 61010-2-030
IEC/EN 61010-2-31 for test leads
EMC IEC/EN 61326-1
“This product has been tested to the requirements of
CAN/CSA-C22.2 No. 61010-1, second edition, including
Amendment 1, or a later version of the same standard
incorporating the same level of testing requirements”.
Measurement Category III (CAT III) is for measurements
performed in the building installation. Examples are
measurements on distribution boards, circuit- breakers,
wiring, including cables, bus-bars, junction boxes,
2
switches, socket-outlets in the fixed installation, and
equipment for industrial use and some other equipment,
for example, stationary motors with permanent
connection to the fixed installation.
CENELEC Directives
The instruments conform to CENELEC Low-voltage
directive 2006/95/EC and Electromagnetic compatibility
directive 2004/108/EC
Warning: Read Before Using
• To avoid possible electrical shock or personal injury,
follow these instructions and use the Meter only as
specified in this manual.
• Do not use the Meter or test leads if they appear
damaged, or if the Meter is not operating properly.
If in doubt, have the Meter serviced.
• Always use the proper function and range for
measurements.
• Before rotating the function range selection switch,
disconnect test probe from circuit under test.
• Verify the Meter’s operation by measuring on a
known voltage source.
• Do not apply more than the rated voltage, as
marked on the Meter, between the test probe or
between any test probe and earth ground.
• Use the Meter with caution for voltages above 30
Vac rms, 42 Vac peak, or 60 Vdc. These voltages pose
electrical shock hazards.
• Disconnect circuit power and discharge all highvoltage capacitors before testing resistance.
• Do not use the Meter around explosive gas or vapor.
• When using the test leads, keep your fingers behind
the finger guards.
• Remove test leads from the Meter before opening
the Meter case or battery door.
• if the meter is used in a manner not specified in
the users manual, the protection provided by the
equipment may be impaired
3
UNPACKING AND INSPECTION
Your shipping carton should include:
1 AM-500-EUR Multimeter
1 Pair of test leads
2 1.5V alkaline AAA battery (installed)
1 Users manual
If any of the items are damaged or missing, return
the complete package to the place of purchase for an
exchange.
FEATURES
Easy to use digital multimeter designed for the
homeowner or DIY enthusiast. Install, troubleshoot or
repair light fixtures, fans, appliances, or automotive
electrical problems with easy and safety of a CAT III 600V
rated product. Check for voltage in electrical sockets,
extension cords, batteries and other electrical circuits. Let
the power of a professional Amprobe multimeter keep
you safe and help you solve all your electrical challenges.
• Measurements: Voltage up to 600V AC/DC, AC/DC
Current and Resistance
• Audible continuity
• Diode Test
• Data hold
• Auto power off
• Low battery warning
• Safety: CAT III 600V
4
MAKING MEASUREMENT
1. Use the proper function and range for
measurements.
2. To avoid possible electrical shock, personal injury or
damages to the Meter, disconnect circuit power and
discharge all high-voltage capacitors before testing
resistance and diode.
3. Connecting test leads:
• Connect the common (COM) test lead to the circuit
before connecting the live lead.
• After measurement, remove live lead before
removing the common (COM) test lead from the
circuit.
4. Symbol “OL” is displayed on LCD when the
measurement is out of range.
Rotary Switch Positions
Switch PositionMeasurement Function
AC or DC voltage measurement (use
SELECT button for switching to AC
or DC).
Resistance measurement
Voltage measurement of diode PN
junction
Continuity measurement
For measurement of dry batteries of
9V
not exceeding 15Vdc
For measurement of dry batteries of
1.5V
not exceeding 2Vdc
AC or DC current measurement (use
SELECT button for switching to AC
or DC).
μA
V
mA A
5
Press to select altemate measurement
SELECT
Button
functions on the rotary switch.
DATA
Display freezes present reading
HOLD
SELECT Button
Press the yellow SELECT button to select alternate
measurement functions on the rotary switch.
DATA HOLD Button
Press DATA HOLD button to freeze present reading on
display. Press again to resume normal operation.
Auto Power OFF
Auto power off: approx. 15 minutes.
When the Meter is in auto power off mode, press SELECT
or DATA HOLD button to resume normal operation.
Measuring AC and DC Voltage
Press SELECT button to switch to DC voltage
measurement function.
Do not apply on a voltage source higher than
AC/DC 600V.
6
Measuring Resistance
Disconnect circuit power and discharge all
high-voltage capacitors before testing resistance.
Note: On a higher resistance measurement (>1MΩ), the
measurement may take a few seconds to get stable reading.
Measuring Continuity
Disconnect circuit power and discharge all high-
voltage capacitors before testing continuity.
7
Measuring Diode
Disconnect circuit power and discharge all high-
voltage capacitors before testing diode.
Battery Test
Applying a voltage source or incorrect battery type
under battery test may cause personal Injury or damage
to the Meter.
Battery 1.5V range is for dry battery not exceeding 2Vdc.
The resistance load is around 30Ω.
Battery 9V range is for dry battery not exceeding 15Vdc.
The resistance load is around 1KΩ.The resistance load is
around 1KΩ.
8
Measuring AC and DC Current
Press SELECT button for switching to DC current
measurement function.
To avoid personal injury or damage to the Meter:
1. Do not attempt to make an in-circuit current
measurement when the open-circuit potential to
earth ground exceeding 600 V.
2. Switch to proper function and range for your
measurement.
3. Do not place the test probe in parallel with a circuit
when the test leads are connected to the current
terminals.
4. Connect the test leads to the correct input A/mA μA
current terminal and to the circuit before powering
the circuit under test.
5. After measurement, switching OFF the circuit’s
power before removing test leads from the circuit.
or
for
for
For current range from 8-10A, do not measure current
for more than one (1) minute. Wait for 10 minutes
before taking another measurement.
9
SPECIFICATION
Ambient temperature: 23°C ±5°C (73.4°F ±9°F)
Relative temperature: ≤ 75%
Accuracy: ±(% of reading + digits)
Maximum voltage between input terminal and earth
Storage temperature: -10°C ~ +50°C (14°F ~ 122°F)
Electromagnetic compatibility: In an RF filed of 1V/m =
Specified accuracy ±5%
Battery: 2 x 1.5V AAA alkaline battery or equivalent
Low battery indication:
Dimensions (L x W x H): 150 mm x 83 mm x 40 mm (5.9 in
x 3.3 in x 1.6 in)
Weight: Approx. 290g (0.64lb) with batteries installed
10
1. DC Voltage Measurement
RangeResolutionAccuracy
200.0mV0.1mV±(0.8%+3dgt)
2.000V1mV
±(0.8%+1dgt)20.00V10mV
200.0V100mV
600V1V±(1.0%+3dgt)
Input impedance: around 10M; (Input impedance > 3G
for DC 200mV range)
Overload protection: 600VDC or AC rms
2. AC Voltage Measurement
RangeResolutionAccuracy
2.000V1mV
±(1.0%+3dgt)20.00V10mV
200.0V100mV
600V1V±(1.2%+3dgt)
Input impedance: around 10M
Frequency response: 45Hz ~ 400Hz
Overload protection: 600VDC or AC rms
3. Resistance Measurement
RangeResolutionAccuracy
200.0Ω0.1Ω
2.000kΩ1Ω
200.0kΩ100Ω
2.000MΩ1kΩ±(1.2%+2dgt)
20.00MΩ10kΩ±(1.5%+5dgt)
±(1.2%+5dgt) at ≤5Ω
±(1.2%+3dgt) at >5Ω
±(1.0%+2dgt)20.00kΩ10Ω
11
200Ω range: Measured value = (Measured display value)
– (Short-circuiting value of probe)
Open circuit voltage: around 0.5V
Overload protection: 600V
4. : Continuity : Diode measurement
Range ResolutionAccuracy
Open circuit voltage is around 0.5V.
Resistance >150Ω, buzzer will not
0.1Ω
Overload protection: 600V
1mV
sound.
Resistance ≤10Ω, buzzer will sound.
11 < Resistance < 150.........Not
Specified.
Open-circuit voltage is around 1.5V.
Normal voltage is around 0.5V to
0.8V for silicon PN junction.
5. Battery Test
RangeResolutionAccuracy
1.5V
9V
Overload protection:
10mV±(10%+3dgt)
F1 fuse, 0.5A H 700V fast-fuse, 6.3x32mm
For 1.5V range: Load resistance is around 30Ω.
For 9V range: Load resistance is around 1kΩ.
12
6. DC Current Measurement
RangeResolutionAccuracy
200.0μA0.1μA
μA
2000μA1μA
20.00mA10μA
mA
200.0mA0.1mA
2.000A1mA
A
10.00A10mA
Overload protection:
±(1.0%+2dgt)
±(1.2%+3dgt)
mA /μA input:
F1 fuse, 0.5A H 700V fast-fuse, 6.3x32mm
10 A input:
F2 fuse, 10A H 600V fast-fuse, 6x25mm
7. AC Current Measurement
RangeResolutionAccuracy
200.0μA0.1μA
μA
2000μA1μA
20.00mA10μA
mA
200.0mA0.1mA
2.000A1mA
A
10.00A10mA
Frequency response: 45Hz ~ 400Hz
Overload protection:
±(1.2%+2dgt)
±(1.5%+3dgt)
mA /μA input:
F1 fuse, 0.5A H 700V fast-fuse, 6.3x32mm
10 A input:
F2 fuse, 10A H 600V fast-fuse, 6x25mm
13
MAINTENANCE AND REPAIR
If the Meter fails to operate, check battery, test leads, etc.,
and replace as necessary.
Double check the followings:
1. Replace the fuse or battery if the meter does not
work.
2. Review the operating instructions for possible
mistakes in operating procedure.
Except for the replacement of the battery, repair of the
meter should be performed only by an Authorized Service
Center or by other qualified instrument service personnel.
The front panel and case can be cleaned with a mild
solution of detergent and water.
Apply sparingly with a soft cloth and allow to dry
completely before using. Do not use aromatic
hydrocarbons, Gasoline or chlorinated solvents for
cleaning.
14
BATTERY AND FUSE REPLACEMENT
WARNING
To avoid shock, injury, or damage to the Meter:
Disconnect test leads before opening case.
Use ONLY fuses with the amperage, interrupt,
voltage, and speed ratings specified.
Replacing BATTERY follow below steps:
1. Disconnect the test lead probe from measuring
circuit.
2. Turn the Meter to OFF position.
3. Remove the screws from the battery cover and
open the battery cover
4. Remove the batteries and replace with two
1.5V Alkaline Batteries (AAA) or equivalent. Pay
attention to the polarity signs.
5. Put the battery cover back and re-fasten the screw.
Battery: 1.5V Alkaline Batteries (AAA) or equivalent
15
Replacing FUSE follow below steps:
1. Disconnect the test lead probe from measuring
circuit.
2. Turn the Meter to OFF position and remove the
holster.
3. Remove the screws from the enclosure and open
the enclosure.
4. Remove the broken fuse and replace with new
specified fuse.
5. Put the enclosure back and re-fasten the screw.
Amprobe garantit l’absence de vices de matériaux et de fabrication
de ce produit pendant une période d’un an prenant effet à la
date d’achat, sauf disposition contraire prévue par la loi. Cette
garantie ne s’applique pas aux fusibles, aux piles jetables ni à tout
produit mal utilisé, modifié, contaminé, négligé ou endommagé
par accident ou soumis à des conditions anormales d’utilisation
et de manipulation. Les revendeurs n’ont pas l’autorisation
de prolonger toute autre garantie au nom d’Amprobe. Pour
bénéficier de la garantie, renvoyez le produit accompagné d’un
justificatif d’achat auprès d’un centre de services agréé par
Amprobe ou d’un distributeur ou d’un revendeur Amprobe. Voir la
section Réparation pour tous les détails. LA PRÉSENTE GARANTIE
EST LE SEUL ET EXCLUSIF RECOURS DE L’UTILISATEUR TOUTES
AUTRES GARANTIES, EXPLICITES, IMPLICITES OU STATUTAIRES,
NOTAMMENT LE CAS ÉCHÉANT LES GARANTIES DE QUALITÉ
MARCHANDE OU D’ADAPTATION À UN OBJECTIF PARTICULIER
SONT EXCLUES PAR LES PRÉSENTES. LE FABRICANT NE SERA EN
AUCUN CAS TENU RESPONSABLE DE DOMMAGES PARTICULIERS,
INDIRECTS, ACCIDENTELS OU CONSÉCUTIFS, NI D’AUCUNS DÉGATS
OU PERTES DE DONNÉES, SUR UNE BASE CONTRACTUELLE, EXTRACONTRACTUELLE OU AUTRE. Étant donné que certaines juridictions
n’admettent pas les limitations d’une condition de garantie
implicite ou l’exclusion ou la limitation de dégâts accidentels ou
consécutifs, il se peut que les limitations et les exclusions de cette
garantie ne s’appliquent pas à votre cas.
Réparation
Tous les outils de test renvoyés pour être réparés au titre de la
garantie ou pour étalonnage doivent être accompagnés des
éléments suivants : nom, raison sociale, adresse, numéro de
téléphone et justificatif d’achat. Ajoutez également une brève
description du problème ou du service demandé et incluez les
cordons de test avec l’appareil. Les frais de remplacement ou
de réparation hors garantie doivent être acquittés par chèque,
mandat, carte de crédit avec date d’expiration, ou par bon de
commande payable à l’ordre de Amprobe®.
Remplacements et réparations sous garantie – Tous pays
Veuillez lire la déclaration de garantie et vérifiez la pile avant
de demander une réparation. Pendant la période de garantie,
tout outil de test défectueux peut être renvoyé auprès de votre
distributeur Amprobe® pour être échangé contre un produit
identique ou similaire. Consultez la section « Where to Buy » sur le
site www.amprobe.com pour obtenir la liste des distributeurs dans
votre région. Les appareils sous garantie devant être remplacés
ou réparés au Canada et aux États-Unis peuvent également être
envoyés dans un centre de services Amprobe® (voir les adresses
ci-dessous).
Remplacements et réparations hors garantie – Canada et États-Unis
Les appareils à réparer hors garantie au Canada et aux ÉtatsUnis doivent être envoyés dans un centre de services Amprobe®.
Appelez Amprobe® ou renseignez-vous auprès de votre lieu
d’achat pour connaître les tarifs en vigueur de remplacement ou de
réparation.
Aux États-Unis et au Canada
Amprobe Amprobe
Everett, WA 98203 Mississauga, ON L4Z 1X9Canada
Tél. : 877-AMPROBE (267-7623) Tél. : 905-890-7600
Remplacements et réparations hors garantie – Europe
Les appareils européens non couverts par la garantie peuvent
être remplacés par votre distributeur Amprobe® pour une somme
nominale. Consultez la section « Where to Buy » sur le site www.
metermantesttools.com pour obtenir la liste des distributeurs dans
votre région.
Adresse postale européenne*
Amprobe® Test Tools Europe
Beha-Amprobe GmbH
In den Engematten 14
79286 Glottertal, Allemagne
Tél. : +49 (0) 7684 8009 - 0
www.beha-amprobe.com
*(Réservée à la correspondance – Aucun remplacement ou
réparation n’est possible à cette adresse. Nos clients européens
doivent contacter leur distributeur.)
Multimètre numérique AM-500-EUR
4
7
8
1
32
5
6
1
Afficheur LCD
2
Bouton de sélection
5
Borne d’entrée pour les mesures de tension, de
résistance, le contrôle de diode et de continuité
6
Borne d’entrée pour le test des piles et les mesures mA
ou μA ac/dc
7
Borne d’entrée pour les mesures A ac/dc jusqu’à 10 A