BC Biomedical ESU-2050 User Manual

Electrosurgical
Unit Analyzer
ESU-2050
PRELIMINARY
BC BIOMEDICAL
ESU-2050
TABLE OF CONTENTS
WARNINGS, CAUTIONS, NOTICES ........................................................................... 2
DESCRIPTION............................................................................................................. 6
OVERVIEW.................................................................................................................. 7
KEYS............................................................................................................................ 15
POWER UP SETTINGS............................................................................................... 17
GRAPH MODE............................................................................................................. 19
ERROR MESSAGES ................................................................................................... 22
®
DFA
TECHNOLOGY .................................................................................................. 23
PC INTERFACE........................................................................................................... 24
MANUAL REVISIONS.................................................................................................. 33
WARRANTY................................................................................................................. 33
SPECIFICATIONS ....................................................................................................... 34
NOTES......................................................................................................................... 36
1
WARNING - USERS
The ESU-2050 Analyzers are for use by
skilled technical personnel only.
WARNING - USE
The ESU-2050 Analyzers are intended for testing
only and they should never be used in
diagnostics, treatment or any other capacity
where they would come in contact with a patient.
WARNING - MODIFICATIONS
The ESU-2050 Analyzers are intended for use
within the published specifications. Any
application beyond these specifications or any
unauthorized user modifications may result in
hazards or improper operation.
WARNING - CONNECTIONS
All connections to patients must be removed
before connecting the Device Under Test (DUT)
to the Analyzer. A serious hazard may occur
if the patient is connected when
testing with the Analyzer.
Do not connect any leads from the patient
directly to the Analyzer or DUT.
WARNING – POWER ADAPTOR
Unplug the Power Adaptor before
cleaning the surface of the Analyzer.
WARNING - LIQUIDS
Do not submerge or spill liquids on the Analyzer.
Do not operate the Analyzer if internal
components not intended for use with fluids may
have been exposed to fluid, as the internal
leakage may have caused corrosion and be a
potential hazard.
2
CAUTION - SERVICE
The ESU-2050 Analyzers are intended to be
serviced only by authorized service personnel.
Troubleshooting and service procedures
should only be performed by
qualified technical personnel.
CAUTION - ENVIRONMENT
The ESU-2050 Analyzers are intended to function
between 15 and 30 °C. Exposure to temperatures outside this range can adversely affect the performance of the Analyzer.
CAUTION - CLEANING
Do not immerse. The Analyzer should be
cleaned by wiping gently with a damp, lint-free
cloth.
CAUTION - INSPECTION
The ESU-2050 Analyzers should be
inspected before each use for wear and
the Analyzer should be serviced
if any parts are in question.
3
NOTICE – SYMBOLS
Symbol Description
Caution
(Consult Manual for Further Information)
Center Positive
Direct Current
RF Current Transformer
NOTICE – ABBREVIATIONS
Amps Ampheres
c centi- (10
C Celsius
CF Crest Factor
° degree
DFA Digital Fast Acquisition
DUT Device Under Test
hrs hours
Hz hertz k kilo- (10
kg kilograms kHz kilohertz
lbs pounds
L1, L2, L3 Location 1, 2, 3
M Mega- (10
MHz Megahertz
µ micro- (10
µA microampere
m milli- (10
mA milliampere
mHz millihertz
mm millimeter
ms millisecond
mV millivolts
ohm
PC Personal Computer
Pk peak
RF Radio Frequency
RMS Root Mean Square
US United States
V volt
VDC Direct Current Voltage
3
)
-3
-2
)
6
)
-6
)
)-
4
USER ASSUMES FULL RESPONSIBILITY FOR UNAUTHORIZED EQUIPMENT MODIFICATIONS OR APPLICATION OF EQUIPMENT OUTSIDE OF THE PUBLISHED INTENDED USE AND SPECIFICATIONS. SUCH MODIFICATIONS OR APPLICATIONS MAY RESULT IN EQUIPMENT DAMAGE OR PERSONAL INJURY.
BC GROUP INTERNATIONAL, INC. RESERVES THE RIGHT TO MAKE CHANGES TO ITS PRODUCTS OR SPECIFICATIONS AT ANY TIME, WITHOUT NOTICE, IN ORDER TO IMPROVE THE DESIGN OR PERFORMANCE AND TO SUPPLY THE BEST POSSIBLE PRODUCT. THE INFORMATION IN THIS MANUAL HAS BEEN CAREFULLY CHECKED AND IS BELIEVED TO BE ACCURATE. HOWEVER, NO RESPONSIBILITY IS ASSUMED FOR INACCURACIES.
NOTICE – CONTACT INFORMATION
NOTICE – DISCLAIMER
NOTICE – DISCLAIMER
BC BIOMEDICAL
BC GROUP INTERNATIONAL, INC.
PO BOX 25125
9415 GENTRY AVE
ST. LOUIS, MO 63125
USA
1-800-242-8428
314-638-3800
www.bcgroupintl.com
sales@bcgroupintl.com
Manual ESU-2050 Series Copyright © 2007
www.bcgroupintl.com
Made in the USA
2/07 Rev 03
5
BC BIOMEDICAL
ESU-2050
ELECTROSURGICAL UNIT ANALYZER
The Model ESU-2050 Electrosurgical Unit Analyzer is a high accuracy True RMS RF Voltmeter designed to be used in conjunction with an RF Current Transformer to measure various parameters relating to Electrosurgical Units. It is microprocessor based and utilizes a combination of unique hardware and software to provide meaningful and accurate results even from difficult signals (like Spray). The Patent Pending DFA system to digitize the signal, analyze its components and provide highly accurate results. It may be used as a stand-alone meter or in conjunction with a PC utilizing the provided software.
The following are highlights of some of the main features:
®
TRUE RMS READINGS USING DFA
TECHNOLOGY
MV, MV PEAK, MA, CREST FACTOR AND WATTAGE RANGES
LARGE GRAPHICS DISPLAY WITH CURSOR SELECTION
OF OPTIONS AND SETUP OF PARAMETERS
®
Technology allows the
1% MEASUREMENT ACCURACY
DIGITAL DATA OUTPUT VIA USB AND RS232
PC BASED INTERFACE PROGRAM
DIGITAL CALIBRATION – NO POTS TO TURN
SELECTABLE DISPLAY OPTIONS
DISPLAY CONTRAST IS SOFTWARE ADJUSTABLE
TACTILE KEYS WITH AUDIO FEEDBACK
GRAPHICAL REPRESENTATION OF MEASURED SIGNAL
STANDARD RANGE USES 0.1:1 RF CURRENT TRANSFORMER
SPECIAL LOW RANGE USES 1:1 RF CURRENT TRANSFORMER
INTERNALLY PROTECTED INPUT CIRCUITRY
INTERNAL DATA STORAGE FOR 3 FULL DATA SETS
ACCESSORIES:
BC20 – 21xxx UNIVERSAL POWER SUPPLY BC20 – 41xxx COMMUNICATIONS CABLE (USB) BC20 – 41xxx COMMUNICATIONS CABLE (RS232) BC20 – 31xxx CD, ESU2050 INTERFACE SOFTWARE BC20 – 30xxx SOFT SIDED CARRYING CASE
6
OVERVIEW
This section looks at the layout of the ESU-2050 and gives descriptions of the elements that are present.
Backlit LCD Graphical Display
RF Current Transformer (Donut ) Input
10 Light Touch Keys for Selecting Parameters and Settings:
High Impact Plastic Case
Swivel and Locking Handle
Power
2.1 mm Jack
USB
RS232 DB9
7
Power Switch Rocker Switch
MAIN SCREENS
– There are six main screens, 5 Display Screens which have 1, 2, 3, 4
and 5 display zones respectively and the Quick Config screen which displays the current
hardware configuration. In the Display Screens, each Display Zone can be customized to
show the desired parameter of mV RMS, mA RMS, Watts, mV Peak or Crest Factor.
The available screens can be toggled through using .
Display Screens
One Display Zone Screen with mV parameter selected
Two Display Zone Screen with mV and Watts parameters selected
Three Display Zone Screen with mV, Watts and mA parameters selected
Four Display Zone Screen with mV, Watts, mA and mV
8
Peak parameters selected
A
Quick Config Screen:
Five Display Zone Screen with mV, Watts, mA and mV Peak and CF parameters selected
Donut Atten
0.1 : 1 1 : 1
NOTE: Load Resistance can be
djustable or Selected from the table of available resistor combinations. (See Load Table for more information).
Load
Resistance
0 –
6,500.0
ohms
The Quick Config Screen allows the user to see the current configuration and provide a
quick method of changing the RF Current Transformer (Donut) Attenuation or Load
Resistance parameters.
Use to highlight the parameter to change and then to sequence through
the available options.
NOTE: On power up, the Quick Config Screen will display for a few seconds to indicate the
current configuration and then the default Display Screen will be displayed. The Quick
Config Screen can be accessed using .
9
DISPLAY PARAMETERS
– There are five options of parameters that can be selected for
each Display Zone on the Main Screens. This allows users to custom configure the
displays to best suit their needs.
Use to highlight the Display Zone to change and then to sequence through
the available parameters.
NOTE: To save a custom configuration, see Power Up Settings section.
SYSTEM CONFIGURATION SCREEN – The SETUP Mode allows the user to adjust the
configuration of the unit. The Setup screen can be entered using the key.
The parameters can be changed by using to highlight the line and to
toggle the available options. The Setup screen can be exited using the key.
Typical Setup Screen
10