SBE Biomedical >?
A UNIT OF BC GROUP INTERNATIONAL, INC
DIGITAL PRESSURE METERS
DPM-2001PLUS |
DPM-2100 |
USER |
MANUAL |
|
BC BIOMEDICAL |
|
|
|
|
DPM-2001/2001 |
PLUS/2100 |
|
|
|
TABLE OF CONTENTS |
|
|
|
DESCRİPTİON |
|
|
hn |
3 |
SYSTEM INDICATORS «οκ |
|
5 |
||
KEYS: |
|
\ |
|
|
DPM-2001 |
|
|
> |
6 |
DPM-2001 PLUS ie |
|
8 |
||
DPM-2100 ικα |
aaa |
|
10 |
|
SETUP MODE |
|
arnertt |
12 |
|
INPUTS e |
μμ υ------ |
|
13 |
|
STATUS DANS |
|
a a |
nr |
14 |
COMMUNICATIONS |
me |
a |
nn |
15 |
MANUAL REVISIONS |
enem |
|
ως |
20 |
WARRANTY |
|
eat |
20 |
|
SPECIFICATIONS |
e |
|
21 |
|
NOTES |
|
|
nu |
26 |
NOTICE
BC GROUP INTERNATIONAL, INC. RESERVES THE RIGHT TO
MAKE |
CHANGES TO |
ITS PRODUCTS OR SPECIFICATIONS AT |
ANY |
TIME, WITHOUT |
NOTICE, IN ORDER TO IMPROVE THE |
DESIGN OR PERFORMANCE AND TO SUPPLY THE BEST
POSSIBLE |
PRODUCT. THE INFORMATION IN THIS MANUAL |
|
HAS BEEN CAREFULLY CHECKED AND IS BELIEVED TO BE |
||
ACCURATE. |
HOWEVER, |
NO RESPONSIBILITY IS ASSUMED |
|
FOR |
INACCURACIES. |
CONTACT |
INFORMATION |
|
BC |
BIOMEDICAL |
|
BC GROUP |
INTERNATIONAL, INC. |
|
PO |
BOX 25125 |
|
9415 |
GENTRY |
AVE |
ST. LOUIS, MO |
63125 |
|
|
USA |
|
1-800-242-8428
314-638-3800
www.bcqroupintl.com
sales@bcgroupintl.com
Manual DPM-2001, 2001 PLUS, 2100 |
Copyright © |
2006 |
www.bcgroupintl.com |
MADE IN THE |
USA |
05/06 |
Rev |
07 |
BC GROUP
DPM-2001/2001 PLUS/2100
DIGITAL PRESSURE METERS
The Model OPM-2001 |
Series |
is a |
Microprocessor |
based Digital |
Pressure |
Meter |
family. |
|||||
They |
measure |
both |
gas |
and liquid |
pressures |
and provide |
multiple |
engineering |
unit |
displays |
||
for the |
results. |
The |
DPM-2100 |
Series adds |
temperature |
measurement. The |
following are |
|||||
highlights of some |
of the main |
features. |
А |
|
|
|
|
|
ОРМ-2001:
»-13.50 TO 100.00 PSI RANGE
0.1% FS ACCURACY (Pressure)
PRESSURE SCALES INCLUDE PSI, inH20, cmH20, AND mmHg DIGITAL CALIBRATION — NO POTS TO TURN
5 DIGIT LCD PLUS SCALE INDICATION BATTERY LIFE DISPLAY (0 to 100%) PROGRAMMABLE DIGITAL FILTER
LCD CONTRAST IS SOFTWARE ADJUSTABLE
16 BIT PRESSURE MEASUREMENT DIGITAL ZERO ADJUST
DPM-2001 PLUS:
Includes all the features of the DPM-2001 and:
« |
MAX and MIN PRESSURE VALUE STORAGE |
e |
RS232 SERIAL COMMUNICATIONS |
DPM-2100:
Includes all the features of the DPM-2001 and:
eMAX and MIN PRESSURE VALUE STORAGE RS232 SERIAL COMMUNICATIONS
YSI 700 TEMPERATURE PROBE INTERFACE 0.0-100.0 C / 32.0-212.0 F TEMPERATURE RANGE 0.5% FS ACCURACY (Temperature)
MAX and MIN TEMPERATURE VALUE STORAGE
DPTIONAL ACCESSORIES:
BE2000PU
BE2000PE
DPM2000C
BC20-01004
BC20-01005
120 |
VAC |
BATTERY |
ELIMINATOR, |
U.S. |
|
220 |
VAC |
BATTERY |
ELIMINATOR, |
EUROPE |
|
RS-232 |
CABLE |
|
|
|
|
HARD CARRYING |
CASE |
|
|
||
UNIVERSAL PRESSURE |
ADAPTER |
KIT |
|
|
|
|
|
|
|
|
SYSTEM |
INDICATORS |
|
|
|
|
|
|
|
|
|
|||||||
Four indicators are provided to identify the Current Operating |
Mode. |
|
|
|
|
|
|
||||||||||||||||||
PRESSURE |
SCALE |
- The |
pressure scale is indicated by |
an identifier bar. |
The |
RANGE |
|||||||||||||||||||
key will |
toggle |
the |
pressure |
units among |
PSI, |
mmHG, |
inH2O |
and |
cmH2O. |
The |
following is |
||||||||||||||
a breakdown |
of the |
available |
pressure |
scales |
and |
the |
measurement |
range |
for |
each scale: |
|||||||||||||||
|
Identifier |
Bar |
|
|
|
Pressure |
|
Units |
|
|
|
|
Pressure |
Range |
|
||||||||||
|
|
a |
|
|
|
|
|
|
|
PSIG |
|
|
|
|
|
|
-13.50 |
to |
100.00 |
|
|||||
|
|
pm |
|
|
|
|
|
|
|
mmHg |
|
|
|
|
|
|
|
-701 |
to |
5190 |
|
||||
|
|
=- |
|
|
|
|
|
|
|
inH2O |
|
|
|
|
|
|
|
-374 |
to |
2773 |
|
||||
|
|
= (flashing) |
|
|
|
|
|
cmH20 |
|
|
|
|
|
|
-951 |
to |
7043 |
|
|||||||
|
bar |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
pa |
no |
bar |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: If |
the |
measured |
pressure |
is outside of |
the |
range |
of |
the |
instrument, |
the display |
will |
||||||||||||||
display -HI- or -Lo-. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
NOTE: |
InH20, |
cmH20 and |
mmHg |
ranges |
are |
calibrated |
for |
20 |
degrees |
Celsius. |
|
|
|||||||||||||
TEMPERATURE |
SCALE |
(MODEL |
DPM-2100 |
|
ONLY)— |
The |
temperature |
can |
be |
displayed |
|||||||||||||||
in either degrees |
Celsius or Fahrenheit. |
When |
temperature |
is |
displayed, |
the |
RANGE |
key |
|||||||||||||||||
will toggle |
the |
temperature |
units between Fahrenheit and Celsius. |
|
|
|
|
|
|
||||||||||||||||
|
|
Temperature |
Units |
|
|
|
|
|
Temperature |
Range |
|
|
|
|
|
||||||||||
|
|
|
Degrees |
C |
|
|
|
|
|
|
|
|
|
0.0 |
to |
100.0 |
|
|
|
|
|
|
|||
|
|
|
Degrees |
F |
|
|
|
|
|
|
|
|
|
32.0 |
to |
212.0 |
|
|
|
|
|
|
|||
NOTE: |
If the |
measured |
temperature |
is outside |
of |
the |
range |
of |
the instrument, |
the display |
|||||||||||||||
will display -HI- or -Lo-. |
If |
a probe |
is |
not |
connected, |
the display |
will |
show |
“no |
probe”. |
|
||||||||||||||
LOW |
BATTERY |
— |
When |
the |
battery |
life reaches |
10 |
percent, |
|
the |
display |
will |
show |
the |
|||||||||||
message |
“lo |
bat” |
once |
every |
minute. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LINE POWER - When meter is running from the optional Battery Eliminator (BE2000PU, BE2000PE), the display will show “Line” instead of the battery life remaining.