B&B Electronics FOSTCDRI-ST Quick Start Guide

0 (0)
p/n 8405 FOSTCDRI-Sx-1112qsg-1/4
© 2009 by B&B Electronics. All rights reserved.
www.bb-elec.com orders@bb-elec.com support@bb-elec.com
European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
PRODUCT INFORMATION B&B ELECTRONICS
FOSTCDRI-Sx
Quick Start Guide
Package Contents
FOSTCDRI-Sx Industrial Serial To Single-mode Fiber
Optic Converter
Datasheet (One per shipment)
Power Terminal Block (installed)
Serial Terminal Block (installed)
Fiber Optic Dust Cover (installed)
If any item is missing or damaged, contact B&B Electronics
for a replacement
Front Panel
1
Power TB
2 Position, Removable
2
PWR LED
ON When Power Applied
3
Fiber Port
Single-mode, SC or ST Connectors
4
Fiber RX LED
Flashes when data received
4
Fiber TX LED
Flashes when data transmitted
5
Serial Port TB
5 Position, Removable
6
Serial Switch
Selects RS-232 or RS-422/485 Mode
7
DIP Switch
12 Position
Wiring Terminal
Information
1. Copper Wire Only
2. One Conductor Per Terminal
3. Wire Range 28 to 16 AWG
4. Tightening Torque, 1.7 lb-in.
5. Temperature Rating of Field Wiring - 105°C (221° F)
minimum sized for 60° C (140°F) ampacity.
Note: The label
for the serial
connection
terminal block is
not visible with
the TB installed.
This detail is
provided for
reference.
DIP Switch (SW1)
Pos
ON
OFF
1
RS-485
RS-422
2
HALF-DUPLEX
FULL-DUPLEX
3
2-WIRE
4-WIRE
4
2-WIRE
4-WIRE
5
TERMINATION IN
TERMINATION OUT
6
TX BIAS OUT
TX BIAS IN
7
RX BIAS OUT
RX BIAS IN
8
57.6 KBPS
9
38.4 KBPS
10
19.2 KBPS
11
9.6 KBPS
12
MULTI-DROP
POINT-TO-POINT
Terminal Block
Terminal
RS-232
T-
Output
T+
Not Used
R-
Input
R+
Not Used
G
Ground
Terminal
RS 4852-Wire
RS-422/4854-Wire
T-
Data A(-)
TD A(-)
T+
Data B(+)
TD B(+)
R-
Not Used
RD A(-)
R+
Not Used
RD B(+)
G
Ground
Ground
RS-422/485 Baud Rate /
Timeout
SW1
SW1
SW1
SW1
Timeout
Baud
8
9
10
11
(ms)
9600
OFF
OFF
OFF
ON
1.30
19.2K
OFF
OFF
ON
OFF
0.56
38.4K
OFF
ON
OFF
OFF
0.27
57.6K
ON
OFF
OFF
OFF
0.22
76.8K
ON
OFF
ON
ON
0.14
115.2K
ON
OFF
ON
OFF
0.10
p/n 8405 FOSTCDRI-Sx-1112qsg-2/4
© 2009 by B&B Electronics. All rights reserved.
www.bb-elec.com orders@bb-elec.com support@bb-elec.com
European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
PRODUCT INFORMATION B&B ELECTRONICS
RS-485 2-Wire
1. Loosen the screws to open the Serial TB Lead Clamps for the T-,
T+, and G terminals.
2. Insert the RS-485 2-Wire Signals Leads. The TB will accept 12 to
28 AWG wire.
3. Tighten the screws to close the Serial TB Lead Clamps. Ensure
the clamps hold the leads securely. However, do not over tighten.
4. Position the 422/485/232 Switch to the 422/485 position.
5. Configure the DIP Switch on the bottom of the converter for RS-
485 2-Wire operation.
Installation Notes:
In 2-Wire mode, T(-) and T(+) terminals are tied to the R(-) and
R(+) terminals with DIP Switch SW1-3 and SW1-4.
If Termination is required, a 120Ω resister can be placed
across the R(-) and R(+) terminals by setting SW1-5 to ON.
This converter has 1.2 KΩ pull-up/down bias resistors built
in. To use this bias, set SW1-6 and SW1-7 to ON.
B&B Electronics’ RS-485 Application Note contains more
information about termination and biasing. This reference is
available on our web site.
For a replacement TB, order part number 7466.
RS-422 / RS-485 4-Wire
1. Loosen the screws to open the Serial TB Lead Clamps for the
T-, T+, R-, R+, and G terminals.
2. Insert the RS-422/485 4-Wire Signal Leads. The TB will
accept 12 to 28 AWG wire.
3. Tighten the screws to close the Serial TB Lead Clamps.
Ensure the clamps hold the leads securely. However, do not
over tighten.
4. Position the 422/485/232 Switch to the 422/485 position.
5. Configure the DIP Switch on the bottom of the converter for
RS-422/485 4-Wire operation.
Installation Notes:
If Termination is required, a 120Ω resister can be placed
across the R(-) and R(+) terminals by setting SW1-5 to ON.
This converter has 1.2 KΩ pull-up/down bias resistors
built in. To use this bias, set SW1-6 and SW1-7 to ON.
B&B Electronics’ RS-485 Application Note contains more
information about termination and biasing. This reference
is available on our web site.
For a replacement TB, order part number 7466.