Document No. 422LCOR0812- pg. 1/2
www.bb-elec.com orders@bb-elec.com support@bb-elec.com
International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
PRODUCT INFORMATION B&B ELECTRONICS
DECLARATION OF CONFORMITY
Manufacturer’s Name: B&B Electronics Manufacturing Company
Manufacturer’s Address: P.O. Box 1040
707 Dayton Road
Ottawa, IL 61350 USA
Model Numbers: 422LCOR
Description: RS-232/422 Converter w/LEDs
Type: Light industrial ITE equipment
Application of Council Directive: 89/336/EEC
Standards: EN 50082-1 (IEC 801-2, IEC 801-3, IEC 801-4)
EN 50081-1 (EN 55022, IEC 1000-4-2)
EN 61000 (-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11)
ENV 50204
EN 55024
Robert M. Paratore, Director of Engineering
RS-232 to RS-422 Converter
Model 422LCOR
This RS-232 to RS-422 converter converts unbalanced RS-232 signals to balanced
voltage digital interface to allow communications of 90K bits per second on cable lengths
of 4000 feet. Ten receivers can be connected to any one driver for use in multi-drop
systems.
The RS-232 port uses a female DB-25 type of connector with pins 2 (TD input) and 3 (RD
output) supported. Protective Ground (pin 1) and Signal Ground (pin 7) are also connected. The RS-422 port uses a male
DB-25 type of connector with the Send Data outputs on pins 2 and 14, and the Receive Data inputs on pins 5 and 17.
Protective Ground (pin 1) and Signal Ground (pin 7) are connected through to the RS-232 connector.
INTERCONNECTION OF THE CONVERTER WITH ANOTHER RS-422 DEVICE:
1. The polarity of the two RS-422 lines must be correct. With no data being sent the RS-232 line should be negative
and the RS-422 "A" terminal should be negative with respect to the "B" terminal.
2. The wire recommended in the RS-422 Standard is number 24 AWG copper conductor, twisted-pair telephone cable
with a shunt capacitance of 16 pF per foot.
3. For long runs and/or high data rates it is recommended that the wires be terminated with a resistor at the receive
end. The twisted pair usually used has an impedance of abeout 100 ohms, therefore a 100 ohm resistor is normally used for
the termination. The RS-422 side of the converter requires more power as the transmission line is increased and as the
termination resistor value is reduced, therefore it may be necessary to use a termination resistor that is larger than 100 ohms.
4. The RS-422 driver has the ability to drive 10 RS-422 receivers connected in parallel. A system of multiple receivers
may require some experimentation with location and size of termination resistors, line lengths, grounding, etc.
5. The RS-422 Standard recommends that Protective Ground (pin 1) be connected to a good "green wire" ground. This
may be already connected in your RS-232 equipment. Protective Ground and Signal Ground should be connected to each
other using a 100 ohm 1/2 watt resistor at one end only. If a shielded twisted pair is used the shield be connected to
Protective Ground.
Document No. 422LCOR0812- pg. 2/2
www.bb-elec.com orders@bb-elec.com support@bb-elec.com
International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
PRODUCT INFORMATION B&B ELECTRONICS