Baxi Solo HE A Owner's Manual

© Baxi Heating UK Ltd 2012
Please keep these instructions in a safe place.
If you move house, please hand them over to the next occupier.
Solo HE A Range
Wall Mounted Powered Flue Condensing
Boilers Gas Fired Central Heating Units
User’s Operating Instructions &
2
© Baxi Heating UK Ltd 2012
Natural Gas
Baxi Solo 12 HE A
G.C.No41 075 65
Baxi Solo 15 HE A
G.C.No41 075 66
Baxi Solo 18 HE A
G.C.No41 075 67
Baxi Solo 24 HE A
G.C.No41 075 68
Baxi Solo 30 HE A
G.C.No41 075 69
© Baxi Heating UK Ltd 2012 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988.
Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address:
The Company Secretary, Baxi Heating UK Ltd, Brooks House, Coventry Road, Warwick. CV34 4LL
Full acknowledgement of author and source must be given.
WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages.
1.0 Quick Reference Guide 3
2.0 Troubleshooting 4
3.0 Clearances 6
4.0 Care of the Boiler 7
5.0 Legislation 8
6.0 Notes 9
7.0 Emergency 11
8.0 Warranty & Service 12
Section Page
Contents
Boiler Controls - see opposite page
for Operating Quick Reference Guide
0086
ISO 9001
FM 00866
The Benchmark Scheme
Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk
1.0 Quick Reference Guide
3
© Baxi Heating UK Ltd 2012
ON
Lockout
(Red Light)
Burner On
(Green Light)
Mains On
(Green Light)
Boiler Temperature Control Knob
(No OFF Position)
Reset Button
If Lockout Light is ON, press the Reset Button. If Lockout occurs persistently consult your Installer or Service Engineer.
This indicates that the Burner has fired up and is heating your system.
This indicates that there is electricity to the Boiler.
Turn the Boiler Temperature Control Knob clockwise to increase or anticlockwise to decrease the temperature.
The Reset Button should extinguish the Lockout Light and normal operation commence.
Boiler Temperature Control
Turn the Boiler Temperature Control Knob clockwise to increase or anticlockwise to decrease the temperature.
Reset Button
If the Red Lockout Light ( ) is ON or FLASHING, press the Reset button until the red light goes OFF. If this occurs frequently a fault is indicated and you should contact your installer.
Lockout LED Light
(Red)
Key to Controls
Reset
High
Low
Reset
High
Reset
ON
ON
Low
High
Low
2.0 Troubleshooting
4
© Baxi Heating UK Ltd 2012
Boiler not working
START
Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker).
NO
If no gas, consult your supplier.
Is there electricity to the boiler ? (Green Mains ON Light lit).
Mains ON Light (Green)
Check electrical supply to
boiler is switched on.
NO
YES
Is the Green Burner ON Light lit).
Burner ON Light (Green)
Boiler operating
satisfactorily.
NO
YES
YES
YES
Is the Red Lockout Light illuminated or flashing ?
YES
Press the Reset Button until the red light goes off.
Lockout (Red)
Reset Button
If the light does not go out or keeps coming on.
CONTACT YOUR
INSTALLER OR
SERVICE
ENGINEER.
Reset
ON
High
Low
Reset
High
Low
ON
Reset
Reset
High
Low
ON
High
Low
ON