Baxi DUO-TEC COMPACT 30 GA, LUNA DUO-TEC 1.33 GA, LUNA DUO-TEC 40 GA Instructions For The End User

A
DUO-TEC COMPACT 30 GA
LUNA DUO-TEC 40 GA
LUNA DUO-TEC 1.33 GA
en CONDENSING GAS FIRED WALL MOUNTED COMBINATION BOILER
Instructions for the end user
fr CHAUDIÈRE MURALE À GAZ À CONDENSATION À DEUX SERVICES
Dear Customer, We are sure your new boiler will comply with all your requirements.
Purchasing one of the BAXI products saties your expectations: good functioning, simplicity and ease of use. Do not dispose of this booklet without reading it: you can nd here some very useful information, which will help you to run your boiler correctly and efciently.
Do not leave any parts of the packaging (plastic bags, polystyrene, etc.) within children's reach as they are a potential source of
danger.
CONTENT
SPECIAL ATTENTION BOXES ..........................................................................................................................................3
1. DESCRIPTION ...................................................................................................................................................................4
2. USER CONTROLS .............................................................................................................................................................4
3. OPERATING THE BOILER ................................................................................................................................................5
3.1 TEMPERATURE CONTROL ..............................................................................................................................................5
3.2 BOILER INFORMATION MENU ........................................................................................................................................5
3.3 ERROR MESSAGES AND RESETTING THE BOILER .....................................................................................................6
3.4 OPERATING MODES.........................................................................................................................................................6
4. CENTRAL HEATING SYSTEM PRESSURE ......................................................................................................................7
5. SHUTTING OFF THE BOILER ...........................................................................................................................................7
6. FROST PROTECTION MODE ...........................................................................................................................................7
7. ROUTINE MAINTENANCE INSTRUCTIONS ....................................................................................................................8
8. CHECK LIST.......................................................................................................................................................................8
9. IMPORTANT NOTES .........................................................................................................................................................8
9.1 BOILER LOCATION ...........................................................................................................................................................8
9.2 FLUE TERMINAL ...............................................................................................................................................................8
9.3 POWER FAILURE ..............................................................................................................................................................8
9.4 ADDITIONAL BATHROOM FITTINGS ...............................................................................................................................8
9.5 CLEANING .........................................................................................................................................................................8
9.6 SERVICING ........................................................................................................................................................................8
9.7 GAS LEAK ..........................................................................................................................................................................8
9.8 ELECTRICAL SUPPLY .......................................................................................................................................................8
10. MAINTENANCE SCHEDULES ..........................................................................................................................................9
USER Section (en)
7703471.01 (1-03/18) 2

SPECIAL ATTENTION BOXES

DANGER
"DANGER" indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
"WARNING" indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. If
the information in this manual is not followed exactly, a re or explosion may result causing property damage, personal
injury or loss of life.
CAUTION
"CAUTION" indicates a potentially damaging situation which, if not avoided, could result in minor injuries and substantial product or property damage.
"Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance"
Do not use this boiler if any part has been under water. Immediately call a qualied service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water.
USER Section (en)
BAXI a leading European manufacturer of hi-tech boilers and heating systems, has developed
CSQ-certied quality management (ISO 9001), environmental (ISO 14001) and health and safety (OHSAS 18001) systems. This means that BAXI S.p.A. includes among its objectives the safeguarding of the environment, the reliability and quality of its products, and the health and
safety of its employees.
Through its organization, the company is constantly committed to implementing and improving these aspects in favor of customer satisfaction.
3
7703471.01 (1-03/18)

1. DESCRIPTION

The boiler is a wall mounted, fan assisted room-sealed combination boiler, providing both central heating and domestic hot water
for the LUNA DUO-TEC 40 and DUO-TEC COMPACT 30 models and only the heating for LUNA DUO-TEC 1.33 model.
After initial lighting of the boiler, it will provide central heating (as required). Hot water is always available whenever a hot tap is open.

2. USER CONTROLS

To light the boiler correctly, proceed as follows:
• Check that the system pressure is correct;
• Power the boiler;
• Open the gas tap (yellow, positioned under the boiler);
Select the required heating mode (see section 3.4: "OPERATING MODES").
WARNING
If the information in these instructions is not followed exactly, a re or explosion may result causing property damage,
personal injury or death.
- Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a qualied installer, service agency or the gas supplier.
BUTTONS Key
SYMBOLS Key
USER Section (en)
DHW temperature adjustment
(+ to increase the temperature and – to decrease it)
Heating water temperature adjustment
(+ to increase the temperature and – to decrease it)
Boiler operating information
Operating mode:
DHW – DHW & Heating – Heating Only
Off – Reset – Exit menu/functions
Off: heating and DHW disabled (only boiler frost protection is active)
Ignition fault DHW operating mode enabled
Boiler/system water pressure low Heating mode enabled
Call a qualied service technician Programming menu
Manually resettable fault ( )
Burner lit
Boiler information menu




Fault in progress Set unit of measurement (SI/US)
7703471.01 (1-03/18) 4

3. OPERATING THE BOILER

PRODUCT AND SAFETY INFORMATION
Do not block ow of combustion or ventilation air to boiler.
Should overheating occur or gas supply fail to shut off, do not turn off or disconnect electrical supply to circulator. Instead, shut
off the gas supply at a location external to the appliance.
Do not use this boiler if any part has been under water. Immediately call a qualied service technician to inspect the boiler and to replace any part of the control system and any gas control that has been under water.
PRIMARY WATER
If you have an old system with cast iron radiators, thoroughly ush the system (without boiler connected) to remove sediment. The high-efciency heat exchanger can be damaged by build-up or corrosion due to sediment.
• Do not use petroleum-based cleaning or sealing compounds in boiler system. Gaskets and seals in the system may be damaged. This can result in substantial property damage.
Do not use "homemade cures" or "boiler patent medicines." Substantial property damage, damage to boiler, and/or serious personal injury may result.
Continual fresh make-up water will reduce boiler life. Mineral build up in the heat exchanger reduces heat transfer, overheats
the stainless steel heat exchanger, and causes failure. Addition of oxygen carried in by make-up water can cause internal corrosion to system components. Leaks in boiler or piping must be repaired at once to prevent make-up water.
FREEZE PROTECTION FLUIDS
CAUTION
NEVER use automotive or standard glycol antifreeze. Even ethylene glycol made for hydronic systems. Use only inhibited propylene glycol solutions, which are specically formulated for hydronic systems. Ethylene glycol is toxic and can attack gaskets and seals used in hydronic systems.

3.1 TEMPERATURE CONTROL

Press and respectively to adjust the CH and DHW ow temperature (if an indirect storage tank is tted). When the burner is lit, the display shows the symbol .
HEATING: while the boiler is operating in the heating mode, the display shows the ashing symbol and the heating ow temperature °F / °C.
When connected to an Outdoor Temperature Sensor, indirectly adjust the room temperature (factory setting 68°F / 20°C).
DHW: While the boiler is operating in the DHW mode, the display shows the ashing symbol and the heating ow temperature °F / °C.

3.2 BOILER INFORMATION MENU

Press and hold down for at least 1 second, to display the information indicated in the table. Press to exit.
DESCRIPTION DESCRIPTION
Secondary fault internal code
00
Heating ow temperature (°F/°C)
01
Outdoor temperature (°F/°C)
02
Indirect Tank DHW temperature (boiler CH only)
03
Domestic hot water temperature
04
(boiler with plate exchanger) Water pressure in heating system (PSI/bar)
05
Heating return temperature (°F/°C)
06
Thermo fuse status (000/001)
07
Not used
08
10/11
Setpoint Central Heating (°F/°C)
09
Manufacturing information
Flue sensor temperature (°F/°C)
12
Manufacturing information
13
Identication Open Therm communication
14
Manufacturing information
15
Manufacturing information
16
Fan speed (“i17”x100)
17
Manufacturing information
18
USER Section (en)
5
7703471.01 (1-03/18)

3.3 ERROR MESSAGES AND RESETTING THE BOILER

ERROR description OPERATION
09 10 15 20
28-29
40
50
53
55
83-84-85
86-87
98
109
110
118
125
128
130 - 131
133
134
135 160 162 317 321
384
385
Gas valve connection fault. Call an authorized SERVICE technician
Outdoor sensor fault . Call an authorized SERVICE technician
Gas valve error. Call an authorized SERVICE technician
Central Heating NTC sensor fault. Call an authorized SERVICE technician
Flue NTC heat exchanger sensor fault Call an authorized SERVICE technician
Return NTC sensor fault. Call an authorized SERVICE technician Domestic Hot Water NTC sensor fault
(only for heating-only model with storage boiler).
Obstruction in the ue pipe.
PCB not programmed. Call an authorized SERVICE technician Communication problem between boiler board and
control unit. Probable short circuit on wiring. Internal error. Call an authorized SERVICE technician Pre-circulation alarm (temporary fault). Call an authorized SERVICE technician
Safety thermostat tripped due to over temperature
(pump probably blocked or air in heating circuit).
Hydraulic pressure too low.
No circulation safety trip
(control performed via a temperature sensor).
Loss of ame.
Flue NTC sensor tripped due to over temperature. Call an authorized SERVICE technician
Ignition failure (5 attempts).
Gas supply valve blocked.
Internal error. Call an authorized SERVICE technician Fan fault. Call an authorized SERVICE technician Flue pressure switch (contact open) Call an authorized SERVICE technician Incorrect power supply frequency. Incorrect power supply frequency. NTC domestic hot water sensor faulty . Call an authorized SERVICE technician
Fault ame (parasitic ame).
Input voltage too low. Call an authorized SERVICE technician
If the this fault persists, call an authorized SERVICE technician
If the this fault persists, call an authorized SERVICE technician
If the this fault persists, call an authorized SERVICE technician
If the this fault persists, call an authorized SERVICE technician
If the this fault persists, call an authorized SERVICE technician
If the this fault persists, call an authorized SERVICE technician
If the this fault persists, call an authorized SERVICE technician
Call an authorized SERVICE technician
Switch off the boiler for a few seconds
Call an authorized SERVICE technician
Press the RESET (R) button for at least 2 seconds
Rell the heating system by open the cold water tap
(section 4: central heating system pressure)
Press the RESET (R) button for at least 2 seconds
Press the RESET (R) button for at least 2 seconds
Press the RESET (R) button for at least 2 seconds
Press the RESET (R) button for at least 2 seconds
Press the RESET (R) button for at least 2 seconds
To RESET the boiler press the button ( ) for at least 2 seconds.
USER Section (en)

3.4 OPERATING MODES

SYMBOL
DISPLAYED
OPERATING MODE
DHW
DHW & HEATING
HEATING ONLY
To enable the appliance in DHW - Heating or Heating only press
and choose one of the three available modes.
To disable the boiler operating modes whilst keeping the function enabled, press for at least 3 seconds. Just the symbol appears
on the display (the display backlighting ashes if the boiler is blocked).
repeatedly
frost protection
7703471.01 (1-03/18) 6