User Guide
High Efficiency Wall Hung Condensing Gas Boiler
Baxi Combi
224 – 228 – 424 — 428
Dear Customer,
Thank you very much for buying this appliance.
Please read through the manual carefully before using the product, and keep it in a safe place for later reference. In order to
ensure continued safe and efficient operation we recommend that the product is serviced regularly. Our service and customer
service organisation can assist with this.
We hope you enjoy years of problem-free operation with the product.
Danger
This boiler can be used by children aged 8 years and above and
by persons with reduced physical, sensory or mental capabilities
or lack of experience and knowledge when they have been given
supervision or instruction concerning the safe use of the device
and understand the resulting risks. Children must not be allowed
to play with the appliance. Cleaning and user maintenance must
not be carried out by children without supervision.
Danger
If you smell gas:
1. Turn off the gas supply at the meter.
2. Open windows and doors in the hazardous area.
3. Do not operate light switches.
4. Do not operate any electrical equipment.
5. Do not use a telephone in the hazardous area.
6. Extinguish any naked flame and do not smoke.
7. Warn any other occupants and vacate the premises.
8. Telephone the National Gas Emergency Service on:- 0800
111 999.
Fig.1Taps ON and OFF
Note
If a water or gas leak occurs or is suspected, the boiler can be iso
lated at the inlet valves by turning their taps through 90° (1/4 turn)
downwards.
AON
BOFF
For advice please contact your Installer, Annual Service Provider
or Baxi Customer Support - The Service Division of Baxi. You can
contact Baxi Customer Support on telephone number 0344 871
1545.
When contacting Baxi Customer Support it will be useful to have
the "Benchmark Checklist " at the back of the Installation & Serv
ice Manual to hand as it includes details relevant to the boiler and
installation.
Warning
Do not touch flue/chimney pipes. Depending on the settings of the
appliance, the temperature of flue/chimney pipes may exceed 60
°C.
Do not touch radiators for long periods. Depending on the settings
of the appliance, the temperature of radiators may reach 85 °C.
Take precautions with domestic hot water. Depending on the set
tings of the appliance, domestic hot water temperature may reach
65 °C.
Caution
Do not neglect to service the appliance. Contact a qualified pro
fessional or take out a maintenance contract for the annual servic
ing of the appliance.
1 Safety
67661618 - 1 - 04072016
1.2 Recommendations
Caution
Only qualified professionals are authorised to work on the boiler
and the installation.
The appliance has an integral frost protection mode as long as
there is power to the boiler.
Note
Regularly check the water pressure in the system (recommended
pressure is 1.5 bar).
Keep the appliance accessible at all times.
Do not remove or cover the user information and serial number la
bels affixed to the boiler control flap. They must remain legible
throughout the lifetime of the boiler.
1.2.1
Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme
which aims to improve the standards of installation and commissioning of
domestic heating and hot water systems in the UK and to encourage regu
lar servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by Heating and Hotwater Industry
Council. For more information visit www.centralheating.co.uk
1.2.2
Please ensure that the installer has fully completed the Benchmark Check
list on the inside back pages of the installation instructions supplied with
the product and that you have signed it to say that you have received a full
and clear explanation of its operation. The installer is legally required to
complete a commissioning checklist as a means of complying with the ap
propriate Building Regulations (England and Wales).
All installations must be notified, by the installer, to Local Area Building
Control either directly or through a Competent Persons Scheme. A Build
ing Regulations Compliance Certificate will then be issued to the customer
who should, on receipt, write the Notification Number on the Benchmark
Checklist.
This product should be serviced annually to optimise its safety, efficiency
and performance. The service engineer should complete the relevant sec
tion of the Benchmark Service Record in the Installation & Service manual
after each service.
The completed Benchmark Checklist & proof of annual servicing (where
applicable) will be required in the event of any warranty work.
The Benchmark Scheme
Benchmark Commissioning Checklist
1.3
Liabilities
1.3.1 User's liability
To guarantee optimum operation of the system, you must abide by the fol
lowing instructions:
Read and follow the instructions given in the manuals provided with the
appliance.
Call on a qualified professional to carry out installation and initial com
missioning.
Get your installer to explain your installation to you.
Have the required inspections and maintenance carried out by a quali
fied installer.
Keep the instruction manuals in good condition close to the appliance.
1 Safety
7661618 - 1 - 040720167
1.3.2 Installer's liability
The installer is responsible for the installation and initial commissioning of
the appliance. The installer must abide by the following instructions:
Read and follow the instructions given in the manuals provided with the
appliance.
Install the appliance in compliance with prevailing legislation and stand
ards.
Carry out initial commissioning and any checks necessary.
Explain the installation to the user.
If maintenance is necessary, warn the user of the obligation to check the
appliance and keep it in good working order.
Give all the instruction manuals to the user.
1.3.3 Manufacturer's liability
Our products are manufactured in compliance with the requirements of the
various Directives applicable. They are therefore delivered with the
marking and any documents necessary. In the interests of the quality of
our products, we strive constantly to improve them. We therefore reserve
the right to modify the specifications given in this document.
Our liability as manufacturer may not be invoked in the following cases:
Failure to abide by the instructions on installing the appliance.
Failure to abide by the instructions on using the appliance.
Faulty or insufficient maintenance of the appliance.
2 About this manual
87661618 - 1 - 04072016
2 About this manual
2.1 General
Warning
Installation, repair and maintenance must only be carried out only
by a competent person.
All Gas Safe registered engineers carry an ID card with their licence num
ber and a photograph. You can check your engineer is registered by tele
phoning 0800 408 5500 or online at www.gassaferegister.co.uk
This manual is intended for the user of the Baxi Combi boiler. If the appli
ance is sold or transferred, or if the owner moves leaving the appliance
behind you should ensure that the manual is kept with the appliance for
consultation by the new owner and their installer.
The appliance is designed as a boiler for use in residential domestic envi
ronments on a governed meter supply only. The selection of this boiler is
entirely at the owner’s risk. If the appliance is used for purposes other than
or in excess of these specifications, the manufacturer will not accept any
liability for resulting loss, damage or injury.
The manufacturer will not accept any liability whatsoever for loss, damage
or injury arising as a result of failure to observe the instructions for use,
maintenance and installation of the appliance.
2.2 Additional documentation
2.3 Symbols used
Various timers, external controls, etc. are available as optional extras. Full
details are contained in the relevant sales literature.
2.3.1 Symbols used in the manual
This manual uses various danger levels to draw attention to special in
structions. We do this to improve user safety, to prevent problems and to
guarantee correct operation of the appliance.
Danger
Risk of dangerous situations that may result in serious personal
injury.
Danger of electric shock
Risk of electric shock.
Warning
Risk of dangerous situations that may result in minor personal in
jury.
Caution
Risk of material damage.
Note
Please note: important information.
See
Reference to other manuals or pages in this manual.
2.4
Abbreviations/glossary
CHCentral heating
DHWDomestic hot water
7661618 - 1 - 040720169
PCUPCB for managing burner operation
PncCondensing output
SUSafety PCB
2 About this manual
3 Technical specifications
107661618 - 1 - 04072016
3 Technical specifications
3.1 Homologations
3.1.1 Certifications
Tab.1Certifications
CE certificate number0085CQ0192
NOx class5 (EN 15502)
Boiler typeC13, C
33
3.2
Tab.2General
Tab.3Heating circuit specifications
Tab.4Domestic water circuit specifications
Technical data
3.2.1
Baxi Combi224228424428
Gas council numbers47–077–2147–077–2247–077–2347–077–24
Note
Where low flow taps or fittings are intended to be used in the DHW system connected to the boiler,
it is strongly recommended that the DHW flow rate DOES NOT fall below 2.5 l/min. This will ensure
reliable operation of the DHW function.
Tab.5Electrical specifications
Baxi Combi224228424428
Electrical power supply voltageV230230230230
Electrical power supply fre
quency
Nominal electrical powerW84948494
External fuse ratingAmp3A3A3A3A
Hz50505050
1
2
3
4
567
8
700
279
395
PN-0000264
A
*
5.0
6
B*
285
700
3
95
PN-0000205
5.0
178
3 Technical specifications
7661618 - 1 - 0407201611
Tab.6Other specifications
Baxi Combi224228424428
Degree of protection against humidi
IPIPX5DIPX5DIPX5DIPX5D
ty (EN 60529)
Net weight when empty/water loadkg26/2826/2826/2826/28
Clearances (above/below casing)
front (for servicing)/(in operation)
side (left hand/right hand)
mm
mm
mm
178/250*
1000*/6
5/5
178/250*
1000*/6
5/5
178/250*
1000*/6
5/5
178/250*
1000*/6
5/5
* These are recommended dimensions. See fig. 3 for Minimum allowable clearances
Note
All data in this section are nominal values and subject to normal
production tolerances.
Fig.2
Fig.3
Dimensions and connections
Clearances
3.2.2
1
2
3
4
5
6
7
8
Dimensions and connections/clearances
Safety valve
Heating circuit water flow
Condensates discharge
Heating system/boiler drain tap
Domestic hot water outlet
Gas inlet
Mains cold water inlet
Heating circuit water return
A*Clearances below — 200mm minimum, 250mm recommended
B*Clearances in front — 450mm minimum, 1000mm recommended
The clearances shown in the diagram are minimum requirements to allow
for case removal, spanner access and air movement. These should be ob
served at all times and kept clear of obstructions.