Baxi Combi 133 HE Plus, Combi 100 HE Plus, Combi 80 HE Plus User Operating Instructions Manual

Please keep these instructions safe.
Should you move house, please hand
them over to the next occupier.
Baxi Combi 133 HE Plus
Baxi Combi 100 HE Plus
Baxi Combi 80 HE Plus
Gas Fired Wall Mounted Condensing
User’s Operating Instructions
2
Baxi is one of the leading manufacturers of domestic
heating products in the UK.
Our first priority is to give a high quality service to our
customers. Quality is designed into every Baxi product -
products which fulfil the demands and needs of customers,
offering choice, efficiency and reliability.
To keep ahead of changing trends, we have made a
commitment to develop new ideas using the
latest technology - with the aim of continuing to
make the products that customers want to buy.
Everyone who works at Baxi has a commitment to quality
because we know that satisfied customers mean continued
success.
We hope you get a satisfactory service from Baxi. If not,
please let us know.
Natural Gas
Baxi Combi 133 HE Plus
G.C.No47 075 14
Baxi Combi 100 HE Plus
G.C.No47 075 15
Baxi Combi 80 HE Plus
G.C.No47 075 16
The boiler meets the requirements of Statutory Instrument “ The
Boiler (Efficiency) Regulations 1993 N
o
3083” and is deemed to
meet the requirements of Directive 92/42/EEC on the energy
efficiency requirements for new hot water boilers fired with liquid
or gaseous fuels:-
Type test for purpose of Regulation 5 certified by:
Notified Body 0086.
Product/Production certified by:
Notified Body 0086.
Ref: 86-BL-647
For GB/IE only.
Baxi is a BS-EN ISO 9001
Accredited Company
This product has an energy rating (A) on a scale of A to G.
For more information see www.boilers.org.uk. This is a certification mark.
1.0 Introduction
3
1.1 Introduction
1. Your Baxi Combi 133 - 100 - 80 HE Plus are gas fired,
room sealed, powered flue condensing combination
boilers, providing central heating for your home and mains
fed domestic hot water. It is fully automatic and does not
have a pilot light. Boiler frost protection and pump
protection are an integral part of the appliance.
2. Due to the high efficiency and the resulting low flue gas
temperature a white plume of condensate will be emitted
from the flue outlet terminal. This will be particularly
evident during periods of low outdoor temperatures.
3. The very high efficiency of these boilers also results in
the flue gasses cooling to the point where part of their
moisture content condenses inside the boiler, giving up
further heat as it does so. The condensate is drained to a
suitable disposal point through the plastic waste pipe at the
bottom left of the boiler. This must must not be modified
or blocked.
4. Priority is given to the hot water mode - when a hot
water tap is turned on the supply of heat to the central
heating circuit is interrupted.
1.2 Operating the Boiler
1. The externally mounted Baxi Intellistat, integral Baxi 12
Hour Timer Kit or other type of clock should have been
fitted in your system, together with heating controls. Full
instructions on the use of these controls will have been
supplied with them.
2. Hot water will always be available when a hot tap is
opened.
3. Central heating will be available if the Summer/Winter
switch is set to Winter and the timer (or other clock) is set
correctly. It is also dependent on the setting of any room
thermostats or thermostatic radiator valves. Refer also to
Section 3.2 Protection & Precautions on Page 5.
To access the control panel, hinge down the lower door
panel (Fig. 1).
When the boiler is in its standby state, the only visible light
should be the Green ‘Mains ON’.
Lower Door Panel
Fig. 1
NOTE: All Illustrations show the Combi 133 HE Plus unless otherwise stated.
2.0 Operating the Boiler
4
2.1 Temperature Control
Central Heating
The boiler will automatically achieve the optimum flow
temperature for maximum comfort and efficiency.
1. However, in the case of the elderly, infirm or very young,
a lower radiator surface temperature may be desirable. If
so, the central heating flow temperature can be adjusted
between approx 55 °C minimum and approx 82 °C
maximum by turning the Central Heating Maximum
Radiator Temperature Control Knob (Fig. 2).
2. The boiler will light automatically on demand and the
Green ‘Burner ON’ light will be lit whilst water is being
heated (Fig. 2).
3. Priority is given to domestic hot water. The boiler
control system has an automatic time delay built in for
central heating. It is normal that following a shutdown by
the boiler thermostat, timer or other heating control, there
is a delay of around 3 minutes, before re-lighting.
Domestic Hot Water
The boiler will automatically achieve the optimum flow
temperature for maximum comfort and efficiency.
1. The temperature of the domestic hot water can be
adjusted between approx 45 °C minimum and approx
55 °C maximum by turning the Domestic Hot Water
Temperature Control Knob (Fig. 2).
2. The boiler will light automatically on demand. The Green
‘Domestic Hot Water ON’ light will be lit from the tap
being opened until the tap is shut and water has been
heated to the set temperature. The Green ‘Burner ON’
light will be lit whilst water is being heated. (Fig. 2).
Intelligent Pre-Heat: The boiler incorporates an intelligent
pre-heat feature. This ensures that the domestic hot water
to the tap is pre-heated only when the user required hot
water the previous week. The pre-heat switches the boiler
on for approximately 1 minute every 40 minutes when
required. During the first week of operation from power
on, no pre-heating will occur.
Summer/Winter Button
Summer setting (Button Out) - hot water will be provided
when a tap or shower is turned on. Central heating will be
off even if the Timer or other control is set to On.
Winter setting (Button In) - central heating will operate on
demand or the hot water will be provided when a tap or
shower is turned on (Fig. 2).
Domestic Hot Water Temperature Control
Domestic Hot Water
Light - Green
Central Heating
Maximum Radiator
Temperature Control
Burner ON
Light - Green
Mains ON
Light - Green
Summer/Winter
Button
Fig. 2
Low
High
ON
Reset
Low
High
Flame Failure
Light - Red
Reset
Button