Installation instruction protective cover HS35
Features
Protective cover for encoder HS35 – matched for motor flange NEMA 56C (4,5“) and fan cover.
For attachment to a fan cover hammer head bolts are recommended (not included).
Scope of delivery
- 1x protective cover HS35
- 1x contact protection clip
- 3x cylinder screw (0.75 inch long)
- 3x flat washer
- 3x lock washer
- 1x protective label
02.12 – SAP-No.:11085289
Subject to modification in technic and design.
www.baumer.com Errors and omissions excepted.
Mounting protective cover HS35
• The incremental encoder must be slide on to
driveshaft by hand. Do not force! If necessary check
screw customer-supplied
and verify the driveshaft diameter.
• The torque support on mounting side (e.g. motor Bshield) shown in graphic [1] fastening without
pressure. Tightening torque max. 1700 oz-in (max.
12 Nm).
• The incremental encoder shaft fastening with the
clamping ring on the motor shaft. Tightening torque
of the clamping ring screw max. 312 oz-in (2.2 Nm).
[1]
• Protective cover according to graphics [2] put on the
mounting side and attach with the supplied
accessories (3x cylinder screw (0.75 inch long) with
flat washer and lock washer).
Tightening torque max. 2690 oz-in (max. 19 Nm).
[2]
• Set the contact protection clip into the opening
of the protective cover (connector/cable gland)
(graphics [3]).
[3]
opening for
contact protection
clip
contact protection
clip
• Protection label glue centred on the opening
of the protective cover (graphics [4]).
[4]
Installation instruction protective cover HS35.doc 2/2 www.baumer.com/motion
2012-02-21/rnik