Bauknecht CPB1200, CPB1000 Instruction Manual

Page 1
Instructions Manual
Cooker Hood
CPB1000 CPB1200
Page 2
2 2
INDEX
RECOMMENDATIONS AND SUGGESTIONS ..................................................................................................................... 3
CHARACTERISTICS ............................................................................................................................................................. 4
INSTALLATION...................................................................................................................................................................... 5
USE ........................................................................................................................................................................................ 8
MAINTENANCE ..................................................................................................................................................................... 9
EN
Page 3
EN
3 3
RECOMMENDATIONS AND SUGGESTIONS
The Instructions for Use apply to several versions of this appliance. Accordingly, you may
find descriptions of individual features that do not apply to your specific appliance.
INSTALLATION
• The manufacturer will not be held liable for any damages resulting from incorrect or im­proper installation.
• The minimum safety distance between the cooker top and the extractor hood is 650 mm (some models can be installed at a lower height, please refer to the paragraphs on work­ing dimensions and installation).
• Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
• For Class I appliances, check that the domestic power supply guarantees adequate earthing.
Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm.
The route of the flue must be as short as possible.
• Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
• If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appli­ances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air. When the cooker hood is used in conjunction with appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0,04 mbar to prevent fumes being drawn back into the room by the cooker hood.
• In the event of damage to the power cable, it must be replaced by the manufacturer or by the technical service department, in order to prevent any risks.
USE
• The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells.
• Never use the hood for purposes other than for which it has been designed.
• Never leave high naked flames under the hood when it is in operation.
• Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
• Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
• Do not flambè under the range hood; risk of fire
• This appliance is not intended for use by persons (including children) with reduced physi­cal, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person respon­sible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• “ CAUTION: Accessible parts may become hot when used with cooking appliances.”.
MAINTENANCE
• Switch off or unplug the appliance from the mains supply before carrying out any mainte­nance work.
• Clean and/or replace the Filters after the specified time period (Fire hazard).
• Clean the hood using a damp cloth and a neutral liquid detergent.
The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be
handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of
correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by
inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your
household waste disposal service or the shop where you purchased the product
.
Page 4
EN
4 4
CHARACTERISTICS
Dimensions
*
**
Components
Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower,
Filters
2 1 Telescopic Chimney comprising:
2.1 1 Upper Section
2.2 1 Lower Section 8 1 Directioned grid ø 125 mm 9 1 Reducer Flange ø 150-120 mm 10 1 Flange ø 150 mm 10a 1 Damper 15 1 Air Outlet Connection 30 1 Comfort Panels Ref. Q.ty Installation Components
7.2.1 2 Upper Chimney Section Fixing Brackets 11 8 Wall Plugs 12a 8 Screws 4,2 x 44,4 12c 6 Screws 2,9 x 9,5 12e 2 Screws 2,9 x 6,5 Q.ty Documentation
1 Instruction Manual
a
* Dimensions of the hood in ducting version. ** Dimensions of the hood in recycling version.
Page 5
EN
5 5
INSTALLATION
Drilling the Wall and Fixing the Brackets
7.2.1
11
12a
X
116
1÷2
116
565
67
280280
650 mm min
15
Draw the following on the Wall:
• a Vertical line up to the ceiling or top surface, at the centre of the area in which the Hood is to be fitted;
• a Horizontal line: 650 mm min. above the Cooker Top.
• Rest the Bracket 7.2.1 as indicated, 1-2 mm from the ceiling or surface above the hood, aligning its cen­tre (grooves) with the vertical reference line.
• Mark the centres of the holes in the bracket.
• Rest the Bracket 7.2.1 as indicated, X mm under the first bracket (X = height of the Upper chimney provided), aligning its centre (grooves) with the vertical reference line.
• Mark the centres of the holes in the bracket.
• As shown in the drawing, mark a reference point 116 mm from the vertical reference line, and 565 mm above the horizontal reference line.
• As shown in the drawing, mark a reference point 280 mm from the vertical reference line, and 67 mm above the horizontal reference line.
• Repeat this operation on the other side.
N.B. Should installation of the lower bracket 7.2.1 interfere in any way with that of the hood canopy,
the lower bracket 7.2.1 may be omitted.
• Drill the points marked using a ø 8 mm drill bit.
• Insert the plugs 11 into the holes.
• Fix the lower bracket 7.2.1, if it is to be fitted, using the screws 12a (4.2 x 44.4 ) provided.
• Fix the upper bracket 7.2.1 and the bracket supporting connection 15 together, using the 2 screws 12a (4.2 x 44.4 ) provided.
• Tighten the 2 screws 12a (4.2 x 44.4) provided in the hood canopy fixing bores, leaving a gap of 5-6 mm between the wall and the heads of the screws.
Page 6
EN
6 6
Hood body installation
• Before hooking the hood body it is necessary to tighten 2 Vr screws placed in the fixing points of the body.
• Hook the hood body on the 12a screws.
• Tighten completely 12a support screws.
• The correct hood body position can be levelled with Vr screws.
• Fix the hood definitively by tightening the 12a security screws.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe the choice of which is left to the installer.
To install a ø 150
• To install the dumper 10a ø 150.
• Fix the pipe using the pipe clamps 25(not included).
To install a ø 120
• To install a ø 120 mm air exhaust connection, insert the re­ducer flange 9 on the dumper 10a.
• Fix the pipe using the pipe clamps 25(not included).
• Remove any activated charcoal filters.
9
ø 120ø 150
10
10
AIR OUTLET - RECIRCULATION VERSION
• Connect the Flange ø150 10 to the bottom end of the Connec­tor 15
• Join the Hood canopy outlet to the Flange on the bottom part of the Connector, using a rigid or flexible pipe ø150 mm, selec­tion of which is at the discretion of the installation technician.
• Make sure that the Activated charcoal odour filter has been fitted.
ø 150
15
10
Page 7
EN
7 7
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav­ing a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.
Fitting the Chimney
Upper chimney
• Open the two side pieces out slightly, hook them up behind the brackets 7.2.1 and bring them back together again until they are in contact.
N.B. The bottom bracket may be omitted.
• Fix the sides of the Brackets using 4 Screws 12c (2.9 x 9.5), provided.
• Make sure that the Connector outlet is in correspondence with the Chimney openings.
Lower chimney
• Open out the two Chimney side flaps, hook them up between the upper chimney and the wall and then close them up again until they touch.
• Fix the lower part to the Hood canopy at the sides, using 2 screws 12c (2.9 x 9.5) provided.
• Fit the Comfort Panel on the body using the fixing pins provided, and hook up the safety catch.
7.2.1
2.1
2.2
2
15
1
30
12c
12c
12c
1
2
Page 8
EN
8 8
USE
A B C D E F G H
Control board
Key Function Display
A
Switches the extractor motor on and off at the latest selected speed
Indicates the selected speed.
B
Decreases the suction speed.
C
Increases the suction speed.
D
By pressing this key it is possible to activate the intensive speed from any previously se­lected speed. The intensive speed can be acti­vated even when the motor is OFF. This speed has been timed at 10 minutes. After that time the system activates automatically the latest selected speed. This function is suitable for cooking conditions when vapours and smells are of the utmost emission.
HI appears. The spot down on the right side flashes once a second.
E By pressing this key it is possible to set up the
motor to a suction speed at 100 m
3
/h lasting 10 minutes every hour. After this the motor switches off automatically.
When the filter saturation is going on it is pos­sible to reset the alarm by pressing this key for about 3 seconds. The indication is visible only when the motor is off.
Indicates the 24-function. The spot down on the right side flashes and the motor is on.
Once the process is finished the previous indi­cation disappears: FF Indicates that the metal grease filters
saturation alarm has been triggered, and the filters need to be washed. The alarm is triggered after 100 working hours.
EF Indicates that the charcoal filter satura-
tion alarm has been triggered, and the fil­ter has to be replaced; the metal grease filters must also be washed. The charcoal filter is triggered after 200 working hours.
F
By pressing this key it is possible to set the delayed shutdown of the appliance to 30 min­utes. This function is suitable for a complete elimination of the residual smells. It can be activated at any position, and it is deactivated by pressing the key again or by switching off the motor.
Indicates alternately the selected speed of the hood and the time left before the hood shut­down. The spot down on the right side flashes.
G
Turns the light on and off .
H
Turns the light on and off at reduced intensity.
Page 9
EN
9 9
MAINTENANCE
REMOTE CONTROL (OPTIONAL)
The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03­AAA type (not included).
• Do not place the remote control near to heat sources.
• Used batteries must be disposed of in the proper manner.
Cleaning the Comfort Panels
• Pull the Comfort Panel to open it.
• Unhook the security chain by opening the spring catch.
• Disconnect the panel from the hood canopy by sliding the fix­ing pin lever.
• The comfort panel must never be washed in a dishwasher.
• Clean the outside by using a damp cloth and neutral liquid de­tergent.
• Clean the inside as well by using a damp cloth and neutral de­tergent; do not use wet cloths or sponges, or jets of water; do not use abrasive substances.
• When the above operation has been completed, hook the panel back and the spring catch to the hood canopy and close it by turning the knob in the opposite direction.
1
2
Page 10
EN
1
10
Metal grease filters
The Filters can be washed in the dishwashing. They need to be washed when FF-sign appears on the display or in any case every 2 months, or even more frequently in case of particularly inten­sive use of the hood.
Alarm reset
• Switch off the hood and the lights. If the 24h-function has been activated this has to be deactivated.
• Press the E-key till the display is unlit.
Cleaning the filters
• Pull the comfort panels to open them.
• Remove the filters one by one pushing them towards the back side of the hood unit and simultaneously pulling downwards.
• Any kind of bending of the filters has to be avoided when washing them. Before fitting them again into the hood make sure that they are completely dry. (The colour of the filter sur­face may change throughout the time but this has no influence to the filter efficiency).
• When fitting the filters into the hood pay attention that they are mounted in correct position the handle facing outwards.
• Close the comfort panel.
Page 11
EN
1
11
Charcoal filter (recycling version)
• This filter cannot be washed or regenerated. It must be replaced when the EF appears on the display or at least once every 4 months.
Activation of the alarm signal
• In the recycling version hoods the filter saturation alarm must be activated during the instal­lation or later.
• Switch off the hood and the lights.
• Disconnect the hood from the mains supply.
• When restoring the connection press and hold B-key.
• When releasing the key two rotating rectangles appear on the display.
Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly:
• 2 flashes with EF - charcoal filter saturation alarm ACTIVATED
• 1 flash with EF - charcoal filter saturation alarm DEACTIVATED.
REPLACING THE CHARCOAL FILTER
Reset of the alarm signal
• Switch off the hood and the lighting. If the 24h-function has been activated this has to be deactivated.
• Press the E-key until the display is unlit.
Replacing of the filter
• Open the comfort panels by pulling them downwards.
• Remove the metal grease filters.
• Remove the saturated charcoal filter by releasing the fixing hooks.
• Fit the new filter and fasten it in its correct position.
• Put the metal grease filters in their seats.
• Close the comfort panels.
Lighting unit
REPLACING OF THE LED UNIT
LED
• To remove the lighting unit a screwdriver can be used in order to slightly press the side part of the unit.
• Remove the unit, remove the electrical connector and replace the unit with a new one. ("To purchase contact technical support")
Warning: This appliance is fitted with a white LED lamp classed as 1M according to EN 60825-1: 1994 + A1:2002 + A2:2001 standards; maxi­mum optical power emitted @439nm: 7µW. Do not look directly at the light through optical devices (binoculars, magnifying glasses…).
Page 12
436005895_ver1
Loading...