Index: C / 923-1886
Limit Switch for Bypass Level Indicator
Features / Description
All GK switches have bi-stable reed contacts. They can be mounted in any
position around the tube of a magnet-controlled level indicator with stainless
steel clamps, however the cable direction should preferably be downward.
The magnet system in the float will switch over the contact whenever the switch
is passed. This permits an arbitrary arrangement of many switches on the tube
surface without the switches disturbing each other. The switch position must
be checked before installation; it can be set with a ring magnet or the float.
The switch hysteresis depends on the distance to the magnet system in the
float and is smallest when the switches are installed closely along the indication
rail.
Applications
Limit value measuring on magnetically controlled level indicators
Technical Data
Housing:
GK03/GK03L/GK03EXI:
Cable:
GK03:
GK03-EXI:
GK03L:
Protection class: IP 65
Switching power:
GK03:
GK03-EXI:
GK03L:
Temperature range:
GK03:
GK03-EXI:
GK03L:
Option:
GK03:
Approvals:
GK03-EXI:
1,4305 and M16 x1,5 cable gland
Silicone 3x0,5 mm² or
PVC 3x0,34 mm², length 1, 3 or 5 m
PVC 3x0,34 mm², length 1, 3 or 5 m
PVC 4x0,55 mm², length 2 mother lengths or
versions on request
220 V AC/1,0 A/60 VA,
220 V DC/1,0 A/40
W28 V/50 mA
24 V DC/1,0 A/40 W
for Si cable:
-55 °C...+140 °C
-40 °C...+75 °C
Grounding clip (incl. in case of GK03-EXI)
for PVC cable:
-10 °C...+80 °C
-10 °C...+75 °C
-10 °C...+80 °C
` ISSeP08ATEX016X II G Ex ia IIC T6
` II1GD Ex iaD 2D T100
Level
Dimensions (mm / inch)
Type GK03 Limit SwitchesType GK03
Type GK03 Limit SwitchesType GK03
When larger contact ratings are needed than the reed contacts allow,
suitable relays must be used.
When frequently changing process requirements make a permanent
contact position difficult to handle we recommend to order our
transmitters with 4 ...20 mA output and separate trip amplifier UAS 3,
which enables set point changes by touching a keypad and many
additional features.
Order Numbers
Order No.Limit Switch
0303-031GK03 1m PVC cable
0303-028GK03 1m Si cable
0303-032GK03 3 m PVC cable
0303-029GK03 3m Si cable
0303-033GK03 5 m PVC cable
0303-030GK03 5m Si cable
0303-035GK03-EXI 1m PVC cable
0303-027GK03-EXI 3 m Si cable
0303-036GK03-EXI 5 m PVC cable
0303-038GK03L-EXI 2 m PVC cable
Barksdale
Circuit diagram
Subject to technical changes.
1