10 Technical Data
|
BPS3000 |
Measuring element |
Ceramic sensor |
|
optional: piezoresistive sensor |
|
at 600 bar: piezoresistive sensor only |
|
|
Measuring ranges |
0 ... 0.2 bar to 0 ... 600 bar, 0 ... 3 psi to 0 ... 9000 psi, gauge pressure |
|
0 …1 bar to 0 … 10 bar, 0 …15 psi to 0 … 150 psi, absolute |
|
|
Display |
4-digit 14-segment LED display, red, digit height 9 mm |
|
|
Transistor switching outputs PNP |
1 or 2 x NO/NC function (programmable), |
|
adjustable switching time delay 0 ... 9.9 s |
|
|
Operating temperature range |
-10 ... +70 °C / +14 ... +158 °F |
|
|
Media temperature range |
-25 ... +100 °C / -13 ... +212 °F |
|
|
Storage temperature range |
-30 … +80°C / -22 … + 176 °F |
|
|
Process connection |
G ¼" M, G ½" front-flush, 1/4" NPT, 1/2" NPT, 7/16 – 20 UNF, JIC 37° C, |
(fitting "A" without adapter) |
7/16 SAE-4 |
|
|
Protection system/class |
IP65/IP67/III NEMA 6 |
|
|
Electrical connection |
Plug 4/5-pin, M 12x1 |
|
|
Auxiliary power |
15... 32 V DC |
|
|
For further technical data and options please refer to the data sheets
Operating and display elements/Dimensions Dimensions (example) in mm (inch)
(3.38) |
39.8 (1.57) |
(2.00) |
|
51 |
|
85.8 |
|
|
|
1 |
2 |
|
M12x1 |
|
Approx 25.4 (1.00) |
32 (1.26) |
|
Item 1: LEDs
AL (red) – Alarm
S1 (red) – switching point 1
S2 (red) – switching point 2
Item 2: Keys
For functions refer to chapter 7 "Programming" on page 5.
12
Operating Instructions
Dual Pressure Switch BPS3000
1 |
Intended Applications ................................................................................................... |
2 |
|
2 |
Safety Instructions......................................................................................................... |
2 |
|
3 |
Standards ....................................................................................................................... |
3 |
|
4 |
Warranty/Guarantee....................................................................................................... |
3 |
|
5 |
Installation ...................................................................................................................... |
3 |
|
6 |
Commissioning/Operation ............................................................................................ |
5 |
|
7 |
Programming.................................................................................................................. |
5 |
|
|
7.1 |
Parameters............................................................................................................. |
6 |
|
7.2 |
Menu Structure....................................................................................................... |
8 |
8 |
Maintenance/Cleaning ................................................................................................. |
11 |
|
9 |
Decommissioning ........................................................................................................ |
11 |
|
10 |
Technical Data............................................................................................................... |
12 |
|
|
|
|
|
Barksdale Inc.
3211 Fruitland Avenue
Los Angeles, CA 90058-0843 U.S.A.
Phone: (323) 589-6181 Fax: (323) 589-3463
e-mail: sales@barksdale.com www.barksdale.com
Art. no.: 923-1966
Index B, 23.05.2014
Software version: 1.2
Specifications are subject to changes without notice!
Barksdale GmbH
Dorn-Assenheimer Straße 27
D-61203 Reichelsheim
Phone: |
+49 (6035) |
949-0 |
Fax: |
+49 (6035) |
949-111 and 949-113 |
e-mail: |
info@barksdale.de |
www.barksdale.de
1
1 Intended Applications
The dual pressure switch monitors system pressures and has up to two switching outputs and one analog output.
DANGER
The switch may only be used in the specified fields of application.
The temperature ranges must be within the permissible limits. Do not exceed rated pressure and electrical load values.
Observe also the applicable national and local safety instructions for assembly, commissioning and operation of the switch.
The switch is not designed to be used as the only safety device in pressurized systems according to “Pressure Equipment Directive 97/23/EC (PED)”.
2 Safety Instructions
The safety instructions are intended to protect the user from dangerous situations and/or prevent material damage.
In the operating instructions the seriousness of the potential risk is designated by the following signal words:
DANGER
Refers to imminent danger to users.
Nonobservance may result in fatal injuries.
WARNING
Refers to a recognizable danger.
Nonobservance may result in fatal injuries, and destroy the equipment or plant parts.
CAUTION
Refers to a danger.
Nonobservance may result in light injuries and material damage to the switch and/or to the plant.
IMPORTANT
Refers to important information essential to the user.
Disposal
The switch must be disposed of correctly in accordance with the national or local regulations for electric/electronic equipment.
The switch must not be disposed of with the household garbage!
2
3 Standards
The standards applied during development, manufacture and configuration are listed in the CE conformity and manufacturer's declaration.
4 Warranty/Guarantee
Our scope of delivery and services is governed by the legal warranties and warranty periods.
Terms of guarantee
We guaranty for function and material of the dual pressure switch under normal operating and maintenance conditions in accordance with the statutory provisions.
Loss of guaranty
The agreed guaranty period will expire in case of:
incorrect use,
incorrect installation or
incorrect handling or operation contrary to the provisions of these operating instructions.
No liability is assumed for any damage resulting therefrom, or any consequential damage.
See also Barksdale “Standard Terms and Conditions”
5 Installation
CAUTION
Jolts and heavy vibrations must be avoided during transport. Even if the switch casing remains undamaged, inside parts may be damaged and cause malfunctions.
The pressure switch may only be installed and electrically connected by instructed staff.
DANGER
The switch may only be installed in systems where the maximum pressure Pmax is not exceeded (see type label).
Only install the switch when deenergized (electrically and hydraulically/pneumatically).
Mount the pressure switch from the bottom to the fitting using a wrench SW 27 and tighten it to a torque of 45 Nm.
3