These publications can help you install the air conditioner
or heat pump. You can usually find these at your local
library or purchase them directly from the publisher. Be
sure to consult current edition of each standard.
National Electrical Code........................ANSI/NFPA 70
Standard for the Installation................... ANSI/NFPA
90A
of Air Conditioning and
Ventilating Systems
Standard for Warm Air .......................... ANSI/NFPA
90B
Heating and Air
Conditioning Systems
Load Calculation for .............................. ACCA Manual J
Residential Winter and
Summer Air Conditioning
For more information, contact these
publishers:
ACCAAir Conditioning Contractors of America
1712 New Hampshire Ave. N.W.
Washington, DC 20009
Telephone: (202) 483-9370
Fax: (202) 234-4721
ANSIAmerican National Standards Institute
11 West Street, 13th Floor
New York, NY 10036
Telephone: (212) 642-4900
Fax: (212) 302-1286
ASHRAE American Society of Heating, Refrigerating,
Duct Design for Residential................... ACCA Manual
D Winter and Summer Air Conditioning
and Equipment Selection
Manufactured under the following U.S. patent numbers:
5,485,878; 5,301,777; 5,002,116; 4,924,934;
4,875,520; 4,825,936; 4,432,409
NFPANational Fire Protection Association
Batterymarch Park
P.O. Box 9101
Quincy, MA 02269-9901
Telephone: (800) 344-3555
Fax: (617) 984-7057
Manual 2100-348
Page 1
WALL MOUNT GENERAL INFORMATION
AIR CONDITIONING WALL MOUNT MODEL NOMENCLATURE
MODEL NUMBER
CAPACITY
60 - 5 Ton
FEATURE CODE
3 - 3 ton air openings
on 5 ton cabinet
2 - 2 ton air openings
on 5 ton cabinet
NOTE: All vent options are without exhaust capability. May require separate field supplied barometric relief in building.
REVISIONS
WA 60 2 3 A 10 X N X X X A
COLOR OPTIONS
X - Beige (Standard)
1 - White
2 - Mesa Tan
4 - Buckeye Gray
VOLTS & PHASE
A - 230/208/60/1
B - 230/208/60/3
KW
VENTILATION OPTIONS
B - Blank-off Plate
FILTER OPTIONS
N - No Filter WA4823, WA6023, WA602N models ONLY
X - One Inch Throwaway Filter WA4822, WA6022 models ONLY
W- One Inch Washable Filter WA4822, WA6022 models ONLY
P - Two Inch Pleated Filter WA4822, WA6022 models ONLY
Model WA602N is identical to Model WA6023. All references in this
manual to WA6023 apply to WA602N also.
CONTROL MODULES
COIL OPTIONS
X - Standard
1 - Phenolic Coated Evaporator
2 - Phenolic Coated Condenser
3 - Phenolic Coated Evaporator
and Condenser
OUTLET OPTIONS
X - Front (Standard)
TABLE 1
ELECTRIC HEAT TABLE
sledoMA3206AWYLNOYLNOB3206AW
1-V0421-V8021-V0421-V802
WKSPMAHUTBSPMAHUTBSPMAHUTBSPMAHUTB
0.58.02050,711.81008,21--------------------
0.9--------------------7.12006,037.81030,32
0.016.14031,432.63006,52--------------------
WA4822A, WA4822B, WA4823A, WA4823B, WA6022A, WA6022B are not
approved for use with electric heat.
Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.
j
Based on 75° C copper wire. All Wiring must conform to NEC and all local codes.
k
These “minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National
l
Electric Code (latest revision), article 310 for power conductor sizing. CAUTION: When more than one field power
conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of table
310 regarding Ampacity Adjustment Factors when more than 3 conductors are in a raceway.