1.1What's in the box..................................................................................................................................................................................7
2.1Stand base plate mounting..........................................................................................................................................................10
2.3Display position adjustment ........................................................................................................................................................12
3.1Recommendations for daily operation ..................................................................................................................................16
3.3OSD menu use...................................................................................................................................................................................16
3.4OSD menu locking/unlocking.....................................................................................................................................................17
3.7sRGB color space.............................................................................................................................................................................17
3.9White point selection.......................................................................................................................................................................18
3.10 Power save mode.............................................................................................................................................................................19
3.11OSD menu language ......................................................................................................................................................................19
5 Important information.................................................................................................................................................................................23
5.3Biological hazard and returns ....................................................................................................................................................27
5.6Explanation of symbols..................................................................................................................................................................31
Thank you for choosing this Nio Color 2MP 23" display!
Barco's Nio Color 2MP 23" display (MDNC-2123) has everything it takes for your dental practice. It brings
sharp and bright images to your desktop in a stylish but cleanable design.
Did you know?
New regulations (DIN 6868-157) in the dental market define strict standards for displays. It means you'll need
a specific monitor, depending on the lighting conditions in your work environment.
That's why Barco developed a range of displays for the dental practice. One for every environment. Ready to
use out of the box.
Reliable diagnosis in your dental office
The Nio Color 2MP 23" display has been built for use in your reading or treatment room (room classes 5 and 6
as defined by DIN 6868-157). Its high brightness and contrast make subtle details, such as early caries or
microcracks, more visible. So you can make a precise diagnosis based on reliable images.
Automated quality control
The Nio Color 2MP 23" is always up to standard because of Barco's luminance sensor technology and
MediCal QAWeb software. By constantly measuring and monitoring display brightness, we can ensure that
your dental images will look consistent and accurate over time and across displays. It also ensures that the
display conforms with DIN 6868-157, automatically.
Compliant with medical safety standards
The Nio Color 2MP 23" display is available with a protective cover (optional) for easy cleaning while complying
with the medical 60601-1 safety standard. We recommend the version with optional cover if you want to give
your patients a clear picture of their oral health.
CAUTION: Read all the important safety information before installing and operating your Nio Color
2MP 23". Please refer to the dedicated chapter in this user guide.
Warnings, cautions, notes and tips
There are four levels of precautionary or advisory statements that may be used in this user guide. In
descending order of importance, they are:
WARNING: Describes hazards or dangers that might result in personal injury or death.
CAUTION: Describes hazards that could damage the product.
K5902134 /04 Nio Color 2MP 23"
5
Page 6
Welcome!
Gives additional information about the described subject.
Gives extra advice about the described subject.
K5902134 /04 Nio Color 2MP 23"6
Page 7
1.1 What's in the box
123
4
5
6
Overview
•1x Nio Color 2MP 23" display
•1x stand base plate
•1x user guide
•1x system disc
•1x documentation disc
•1x video signal cable
•1x USB cable
•1x set of AC power cords (depending on the region of operation)
Keep your original packaging. It is designed for this display and is the ideal protection during
transport and storage.
1.2 Product overview
Front
Welcome!
Image 1-1
1. Stand base plate
2. Stand pillar
3. Jog dial
•Push long (5 sec):
-to put display in standby mode
•Push short:
-to exit standby mode
-to active the OSD menu
-to confirm selections in the OSD menu
•Turn right
-to scroll up in the OSD menu
-to increase values in the OSD menu
K5902134 /04 Nio Color 2MP 23"7
Page 8
8
1234675
Welcome!
•Turn left
-to scroll down in the OSD menu
-to decrease values in the OSD menu
4. Front sensor
5. Ambient light sensor
6. Power status LED
•Off: Display is in normal operation mode, or display is not powered
•Blinking orange: Display is entering standby mode
•Steady orange: Display is in standby mode
Back
Image 1-2
1. Kensington security slot
2. USB-B 2.0 upstream connector
3. USB-A 2.0 downstream connectors (2x)
4. DisplayPort video input
5. Earth pin
6. DVI-D video input
7. 100 - 240 VAC mains power input (IEC C14)
8. VESA 100 mm mounting screw holes (4x)
K5902134 /04 Nio Color 2MP 23"8
Page 9
Installation2
WARNING: Read all the important safety information before installing and operating your monitor.
Please refer to the dedicated chapter in this user guide.
WARNING: Sufficient expertise is required to install this equipment. All devices and complete setup
must be tested before taking into operation.
CAUTION: When the display is assembled in the medical system, take care of the fixation of all
cables, to avoid unwanted detachment.
CAUTION: The monitor is not intended to be sterilized.
K5902134 /04 Nio Color 2MP 23"
9
Page 10
Installation
2.1 Stand base plate mounting
To mount the stand base plate
1.Put the display face down on a clean and soft surface. Be careful not to damage the panel.
2.Rotate the stand pillar 90° counterclockwise.
Image 2-1
3.Attach the stand base plate to the pillar by fixing the dedicated screw as shown below.
Image 2-2
2.2 Cable connections
To connect the cables
1.Connect one or more video source(s) to the corresponding video inputs. Use the appropriate video cable(s) to
do this.
The input source to be displayed can be selected in the OSD menus (see “Input source selection”, page 17).
K5902134 /04 Nio Color 2MP 23"10
Page 11
Installation
Image 2-3
2.Connect the USB upstream connector to a PC USB host to make use of QAWeb or any of the display USB
downstream connectors (e.g. to connect a keyboard, mouse or other peripheral).
Image 2-4
3.Connect the mains power input to a grounded power outlet.
Image 2-5
4.If necessary for your application, earth the Nio Color 2MP 23" by connecting the earth pin to a grounded outlet
by means of a yellow/green AWG18 wire (maximum admitted cable length according to national regulation
requirements).
Image 2-6
5.Route all cables through the provided cable routing clip at the back of the display stand.
K5902134 /04 Nio Color 2MP 23"11
Page 12
Installation
2.3 Display position adjustment
To adjust the display position
You can safely tilt, raise and lower the display as desired.
Image 2-7
CAUTION: Although the display can be physically rotated to portrait position, this mode is
functionally not supported.
2.4 VESA-mount installation
To mount the display on a VESA arm
The display panel, standard attached to the stand, is compatible with the VESA 100 mm standard.
1. Unscrew the four fixation screws to detach the panel from the stand.
Image 2-8
K5902134 /04 Nio Color 2MP 23"12
Page 13
T
W
L
min
L
max
Installation
2. Use 4 M4 screws to attach the panel to a VESA approved arm. Please respect the following rule to select
an appropriate screw length:
•L
•L
Image 2-9
= T + W + 6 mm
min
= T + W + 14 mm
max
K5902134 /04 Nio Color 2MP 23"13
Page 14
Installation
K5902134 /04 Nio Color 2MP 23"14
Page 15
Operation3
15K5902134 /04 Nio Color 2MP 23"
Page 16
Operation
3.1 Recommendations for daily operation
Optimize the lifetime of your display
Enabling the Display Power Management System (DPMS) of your display will optimize its lifetime by
automatically switching off the backlight when the display is not used for a specified period of time. By default,
DPMS is enabled on your display, but it also needs to be activated on your workstation. To do this, go to
“Power Options Properties” in the “Control Panel”.
Barco recommends setting DPMS activation after 20 minutes of non-usage.
Use a screen saver to avoid image retention
Prolonged operation of an LCD with the same content on the same screen area may result in a form of image
retention.
You can avoid or significantly reduce the occurrence of this phenomenon by using a screen saver. You can
activate a screen saver in the “Display properties” window of your workstation.
Barco recommends setting screen saver activation after 5 minutes of non-usage. A good screen
saver displays moving content.
In case you are working with the same image or an application with static image elements for several hours
continuously (so that the screen saver is not activated), change the image content regularly to avoid image
retention of the static elements.
Understand pixel technology
LCD displays use technology based on pixels. As a normal tolerance in the manufacturing of the LCD, a
limited number of these pixels may remain either dark or permanently lit, without affecting the performance of
the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels.
To learn more about LCD technology and missing pixels, consult the dedicated white papers
available at www.barco.com/healthcare.
Maximize quality assurance
QAWeb guarantees optimum and stabilized image quality in every private practice.
The front sensor on the Nio Color 2MP 23" works seamlessly with QAWeb to ensure a consistent image over
time. It automatically stabilizes the image from the moment you switch on the display. What's more, QAWeb
provides you with instant feedback on the status of the display.
3.2 Standby switching
About
•Push the jog dial long (5 sec) to put your display in standby mode
•Push the jog dial short (1 sec) to exit standby mode and activate your display
3.3 OSD menu use
To open the OSD menu
Shortly push the jog dial during normal operation to open the OSD menu. If the OSD locked message
appears, first unlock it as described in “OSD menu locking/unlocking”, page 17.
The OSD main menu comes up in the left top of the screen. If no further actions are taken within the next 20
seconds, the OSD menu will disappear again (and the keyboard will lock if enabled).
K5902134 /04 Nio Color 2MP 23"16
Page 17
Operation
To navigate the OSD menu
•Turn the jog dial left or right to scroll through the different menu pages, to change values or to make
selections.
•Push the jog dial to go into a submenu or confirm adjustments and selections.
3.4 OSD menu locking/unlocking
About
To avoid unwanted or accidental activation of the OSD menu, a lock mechanism can be enabled. This
mechanism will automatically lock the OSD menu when it's not in use.
To lock the OSD menu
1. Bring up the OSD main menu.
2. Navigate to the Adjustments > Settings > OSD lock menu.
3. Switch OSD menu lock on or off.
4. Exit the OSD menu to activate the selected option.
To unlock the jog dial
During normal operation, turn and hold the jog dial right for 5 seconds, until the OSD unlocked message
appears.
3.5 Input source selection
About input source selection
The Nio Color 2MP 23" can have multiple video inputs connected. Switching between the different inputs can
be done easily in the OSD menu.
To select the input source
1. Bring up the OSD main menu.
2. Navigate to the Input selection menu.
3. Select one of the available input sources and confirm.
3.6 Luminance adjustment
To adjust the luminance
1. Bring up the OSD main menu.
2. Navigate to the Adjustments > Luminance menu.
3. Set a luminance value as desired and confirm.
3.7 sRGB color space
About sRGB color space
The sRGB color space combines a display function and white point selection and is designed to match typical
home and office viewing conditions. It is widely used in most computer applications.
When selecting sRGB, the Display function and White point selection options in the Adjustments
menu will be disabled.
K5902134 /04 Nio Color 2MP 23"17
Page 18
Operation
To select sRGB color space
1.Bring up the OSD main menu.
2.Navigate to the Adjustments menu.
3.Select sRGB and confirm.
3.8 Display functions
Display function selection is disabled when sRGB is selected in the Adjustments menu.
About display functions
Native, uncorrected panels will display all grayscale/color levels with luminance increments that are not
optimal for crucial diagnostic information. Studies have shown however, that in medical images certain
grayscale/color parts contain more diagnostic information then others. To respond to these conclusions,
display functions have been defined. These functions emphasize on these parts containing crucial diagnostic
information by correcting the native panel behavior.
The available display functions for your Nio Color 2MP 23" are:
•Native: If you select Native, the native panel behavior will not be corrected.
•DICOM: DICOM (Digital Imaging and Communications in Medicine) is an international standard that was
developed to improve the quality and communication of digital images in radiology. In short, the DICOM
display function results in more visible grayscales in the images. Barco recommends selecting the DICOM
display function for most medical viewing applications.
The DICOM display function applies ambient light compensation (ALC) taking the ambient light conditions
of your reading room into account. The available reading room options are:
-Office: Selects DICOM function optimized for office conditions (60-180 Lux)
-Operation Room: Selects DICOM function optimized for operating room conditions (300-400 Lux)
•Gamma 1.8 or 2.2: Select one of these display functions in case the display is to replace a CRT display
with a gamma of 1.8 or 2.2 respectively.
•QAWeb: This setting is automatically selected when the display function is determined by Barco's MediCal
QAWeb application. Manually selecting the QAWeb display function is not recommended.
The settings of the display must be adapted to suit the requirements of the visualization software. In
case of doubt, please contact the vendor of the visualization software.
To select a display function
1.Bring up the OSD main menu.
2.Navigate to the Adjustments > Display function menu.
3.Select one of the available display functions and confirm.
3.9 White point selection
White point selection is disabled when sRGB is selected in the Adjustments menu.
About white point selection
This setting allows you to modify the display white point, used as reference for all other colors to be displayed.
K5902134 /04 Nio Color 2MP 23"18
Page 19
Operation
The available white point settings for your display are:
•Native: The native, unmodified color temperature of the LCD panel.
•6500K: Corresponds to a color temperature of 6500 Kelvin (D65).
•7500K: Corresponds to a color temperature of 7500 Kelvin (D75).
To select the white point
1.Bring up the OSD main menu.
2.Navigate to the Adjustments > White point menu.
3.Select one of the available white point presets.
3.10 Power save mode
About power save mode
Enabling power save mode on your Nio Color 2MP 23" will optimize the display lifetime by automatically
switching off the backlight when no video signal is detected after approximately 10 seconds.
To enable/disable power save mode
1.Bring up the OSD main menu.
2.Navigate to the Adjustments > Settings menu.
3.Enter the Power save submenu.
4.Select On or Off as desired and confirm.
3.11 OSD menu language
About the OSD menu language
By default, the OSD menu comes up in English. However, there’s a wide range of other languages available
for the OSD menu of your Nio Color 2MP 23".
To select the language of the OSD menu
1.Bring up the OSD main menu.
2.Navigate to the Adjustments > Settings menu.
3.Enter the OSD Language submenu.
4.Select one of the available languages.
3.12 Factory reset
About factory reset
A factory reset allows you to fully restore the display to its original factory setting.
To perform a factory reset
1.Bring up the OSD main menu.
2.Navigate to the Adjustments > Settings menu.
3.Enter the Factory Reset submenu.
4.Select Press enter to confirm.
K5902134 /04 Nio Color 2MP 23"19
Page 20
Operation
K5902134 /04 Nio Color 2MP 23"20
Page 21
Maintenance4
21K5902134 /04 Nio Color 2MP 23"
Page 22
Maintenance
4.1 Scheduled maintenance
About
The Nio Color 2MP 23" does not require any scheduled maintenance or calibration activities. We recommend
to use QAWeb with the Barco default tests and frequencies to calibrate and maintain the display, or to return
the display to a Barco approved maintenance organization. In any case of doubts, please contact Barco
Healthcare.
4.2 Cleaning
WARNING: Unplug the power cable from the mains power input before cleaning the display.
CAUTION: Take care not to damage or scratch the front glass or LCD. Be careful with rings or other
jewelry and do not apply excessive pressure on the front glass or LCD.
CAUTION: Do not apply or spray liquid directly to the display as excess liquid may cause damage
to internal electronics. Instead, apply the liquid to a cleaning cloth.
To clean the display
Clean the display using a sponge, cleaning cloth or soft tissue, lightly moistened with a recognized cleaning
product for medical equipment. Read and follow all label instructions on the cleaning product. In case of doubt
about a certain cleaning product, use plain water.
Possible cleaning solutions:
•70% isopropyl alcohol
•1.6% aqueous ammonia
•Cidex® (2.4% glutaraldehyde solution)
•Sodium hypochlorite (bleach) 10%
•“Green soap” (USP)
•0.5% Chlorehexidine in 70% isopropyl alcohol
•Like Cleansafe® optical cleaning liquid
Do not use following products:
•Alcohol/solvents at higher concentration > 70%
•Strong alkalis lye, strong solvents
•Acid
•Detergents with fluoride
•Detergents with ammonia at higher concentration > 1.6%
•Detergents with abrasives
•Steel wool
•Sponge with abrasives
•Steel blades
•Cloth with steel thread
K5902134 /04 Nio Color 2MP 23"22
Page 23
Important
information
5
23K5902134 /04 Nio Color 2MP 23"
Page 24
Important information
5.1 Safety information
General recommendations
Read the safety and operating instructions before operating the device.
Retain safety and operating instructions for future reference.
Adhere to all warnings on the device and in the operating instructions manual.
Follow all instructions for operation and use.
Electrical Shock or Fire Hazard
To prevent electric shock or fire hazard, do not remove cover.
No serviceable parts inside. Refer servicing to qualified personnel.
Do not expose this apparatus to rain or moisture.
Modifications to the unit
Do not modify this equipment without authorization of the manufacturer.
Type of protection (electrical)
Monitor with internal power supply: Class I equipment.
Degree of safety (flammable anesthetic mixture)
Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or
nitrous oxide.
Non-patient care equipment
•Equipment primarily for use in a health care facility that is intended for use where contact with a patient is
unlikely (no applied part).
•The equipment shall not be used with life support equipment.
•The user should not touch the equipment, nor its signal input ports (SIP)/signal output ports (SOP) and the
patient at the same time.
Power connection – Equipment with internal power supply
•Power requirements: The equipment must be powered by the AC mains voltage and must be connected to
a mains socket with earth connection.
•The equipment is intended for continuous operation.
Transient over-voltage
If the device is not used for a long time, disconnect it from the AC inlet to avoid damage by transient overvoltage.
To fully disengage the power to the device, please disconnect the power cord from the AC inlet.
High magnetic environment
•The device shall not be used in the high magnetic environment of an MRI scanner.
•The installer shall assess the magnetic environment before installation or use of the device.
Connections
Any external connection with other peripherals must follow the requirements of clause 16 of IEC60601-1 3rd.
Ed. or Table BBB.201 of IEC 60601-1-1 for the medical electrical systems.
To maintain compliance with EMC Regulation, use only shielded interface cables for the connection to
peripheral devices.
K5902134 /04 Nio Color 2MP 23"24
Page 25
Important information
Power cords
•Europe: H05VV-F or H05VVH2-F PVC cord with appropriate EU plug.
US and Canada: “hospital grade” cord-set has to be used, provided with instructions to indicate that
grounding reliability can be achieved only when the equipment is connected to an equivalent receptacle
marked hospital only or hospital grade. These instructions need to be marked either on the equip. or on a
tag on the power cord
•Do not overload wall outlets and extension cords as this may result in fire or electric shock.
•Mains lead protection: Power cords should be routed so that they are not likely to be walked upon or
pinched by items placed upon or against them, paying particular attention to cords at plugs and
receptacles.
•The power supply cord shall only be replaced by the designated operator.
•Use a power cord that matches the voltage of the power outlet, which has been approved and complies
with the safety standard of your particular country.
Water and moisture
Never expose the display to rain or moisture.
Never use the display near water - e.g. near a bathtub, washbasin, swimming pool, kitchen sink, laundry tub or
in a wet basement.
Moisture condensation
Do not use monitor under rapid temperature and humidity change condition or avoid cold air from airconditioning outlet directly.
Moisture may condense on the surface or inside of the unit, or create a mist residue inside the protection
plate, this is not a malfunction of the product itself, although it may cause damage to the monitor.
If condensation appears, let the monitor stand unplugged until the condensation disappears.
Ventilation
Do not cover or block any ventilation openings in the cover of the set. When installing the device in a cupboard
or another enclosed location, heed the necessary space between the set and the sides of the cupboard.
Installation
Place the device on a flat, solid and stable surface that can support the weight of at least 3 devices. If you use
an unstable cart or stand, the device may fall, causing serious injury to a child or adult, and serious damage to
the device.
National Scandinavian Deviations for CL. 1.7.2
Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan"
Norway: "Apparatet må tilkoples jordet stikkontakt"
Sweden: "Apparaten skall anslutas till jordat uttag"
5.2 Environmental information
Disposal Information
Waste Electrical and Electronic Equipment
This symbol on the product indicates that, under the European Directive 2012/19/EU governing waste
from electrical and electronic equipment, this product must not be disposed of with other municipal waste.
Please dispose of your waste equipment by handing it over to a designated collection point for the recycling of
waste electrical and electronic equipment. To prevent possible harm to the environment or human health from
uncontrolled waste disposal, please separate these items from other types of waste and recycle them
responsibly to promote the sustainable reuse of material resources.
K5902134 /04 Nio Color 2MP 23"25
Page 26
Important information
For more information about recycling of this product, please contact your local city office or your municipal
waste disposal service.
For details, please visit the Barco website at: http://www.barco.com/AboutBarco/weee
Turkey RoHS compliance
Türkiye Cumhuriyeti: AEEE Yönetmeliğine Uygundur.
[Republic of Turkey: In conformity with the WEEE Regulation]
中国大陆 RoHS
Chinese Mainland RoHS
根据中国大陆《电器电子产品有害物质限制使用管理办法》(也称为中国大陆RoHS), 以下部分列出了
According to the “Management Methods for the Restriction of the Use of Hazardous Substances in Electrical
and Electronic Products ” (Also called RoHS of Chinese Mainland), the table below lists the names and
contents of toxic and/or hazardous substances that Barco’s product may contain. The RoHS of Chinese
Mainland is included in the MCV standard of the Ministry of Information Industry of China, in the section “Limit
Requirements of toxic substances in Electronic Information Products”.
零件项目(名称)
Component name
印制电路配件
Printed Circuit Assemblies
液晶面板
LCD panel
外接电(线)缆
External Cables
內部线路
Internal wiring
金属外壳
Metal enclosure
塑胶外壳
Plastic enclosure
散热片(器)
Heatsinks
电源供应器
Power Supply Unit
风扇
Fan
文件说明书
Paper Manuals
有毒有害物质或元素
Hazardous substances and elements
铅
Pb
xooooo
xooooo
xooooo
oooooo
oooooo
oooooo
oooooo
xooooo
oooooo
oooooo
汞
Hg
镉
Cd
六价铬
Cr6+
多溴联苯
PBB
多溴二苯醚
PBDE
K5902134 /04 Nio Color 2MP 23"26
Page 27
10
Important information
零件项目(名称)
Component name
光盘说明书
CD manual
本表格依据SJ/T 11364的规定编制
This table is prepared in accordance with the provisions of SJ/T 11364.
o: 表示该有毒有害物质在该部件所有均质材料中的含量均在 GB/T 26572 标准规定的限量要求以下.
o: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part
is below the limit requirement in GB/T 26572.
x: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572 标准规定的限量要求.
x: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials
used for this part is above the limit requirement in GB/T 26572.
All Electronic Information Products (EIP) that are sold within Chinese Mainland must comply with the “Marking
for the restriction of the use of hazardous substances in electrical and electronic product” of Chinese
Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP
logo that Barco uses (please refer to the photo) is based on the “General guidelines of environment-friendly
use period of electronic information products” of Chinese Mainland.
有毒有害物质或元素
Hazardous substances and elements
铅
Pb
oooooo
汞
Hg
镉
Cd
六价铬
Cr6+
多溴联苯
PBB
多溴二苯醚
PBDE
5.3 Biological hazard and returns
Overview
The structure and the specifications of this device as well as the materials used for manufacturing makes it
easy to wipe and clean and therefore suitable to be used for various applications in hospitals and other
medical environments, where procedures for frequent cleaning are specified.
However, normal use shall exclude biological contaminated environments, to prevent spreading of infections.
Therefore use of this device in such environments is at the exclusive risk of Customer. In case this device is
used where potential biological contamination cannot be excluded.
Customer shall implement the decontamination process as defined in the latest edition of the ANSI/AAMI
ST35 standard on each single failed Product that is returned for servicing, repair, reworking or failure
investigation to Seller (or to the Authorized Service Provider). At least one adhesive yellow label shall be
attached on the top site of the package of returned Product and accompanied by a declaration statement
proving the Product has been successfully decontaminated.
Returned Products that are not provided with such external decontamination label, and/or whenever such
declaration is missing, can be rejected by Seller (or by the Authorized Service Provider) and shipped back at
Customer expenses.
5.4 Regulatory information
Indications for use
The Nio Color 2MP 23" is intended to be used as a tool in displaying and viewing digital images (excluding
digital mammography) for review and analysis by trained medical practitioners. Caution (USA): Federal law
K5902134 /04 Nio Color 2MP 23"27
Page 28
Important information
restricts this device to sale by or on the order of a physician. (Details & exemptions are in the Code of Federal
Regulations Title 21, 801 Part D).
Manufacturing country
The manufacturing country of the product is indicated on the product label (“Made in …”).
Importers contact information
To find your local importer, contact one of Barco’s regional offices via the contact information provided on our
website (www.barco.com).
FCC class B
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This device generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If
this device does cause harmful interference to radio or television reception, which can be determined by
turning the device off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the device and receiver.
•Connect the device into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
FCC responsible: Barco Inc., 3059 Premiere Parkway Suite 400, 30097 Duluth GA, United States, Tel: +1
678 475 8000
Canadian notice
CAN ICES-1/NMB-1
5.5 EMC notice
General information
This device is for use in professional healthcare facility environments only.
With the installation of the device, use only the delivered external cables and power supply or a spare part
provided by the legal manufacturer. Using another can result in a decrease of the immunity level of the device.
WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided
because it could result in improper operation. If such use is necessary, this equipment and the other
equipment should be observed to verify that they are operating normally.
WARNING: Use of accessories, transducers and cables other than those specified or provided by
the manufacturer of this equipment could result in increased electromagnetic emissions or
decreased electromagnetic immunity of this equipment and result in improper operation.
WARNING: Portable RF communications equipment (including peripherals such as antenna cables
and external antennas) should be used no closer than 30 cm (12 inches) to any part of the Nio Color
2MP 23", including cables specified by the manufacturer. Otherwise, degradation of the
performance of this equipment could result.
K5902134 /04 Nio Color 2MP 23"28
Page 29
Important information
Electromagnetic emissions
The Nio Color 2MP 23" is intended for use in the electromagnetic environment specified below. The customer
or the user of the Nio Color 2MP 23" should assure that it is used in such an environment.
Emissions test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/ flicker
emissions
IEC 61000-3-3
This Nio Color 2MP 23" complies with appropriate medical EMC standards on emissions to, and interference
from surrounding equipment. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Interference can be determined by turning the equipment off and on.
If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding
equipment, the user is encouraged to try to correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna or equipment.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced technician for help.
Compliance
Group 1The Nio Color 2MP 23" uses RF
Class BThe Nio Color 2MP 23" is suitable
Class D
Complies
Electromagnetic environment –
Guidance
energy only for its internal function.
Therefore, its RF emissions are
very low and are not likely to cause
any interference in nearby
electronic equipment.
for use in all establishments,
including domestic establishments
and those directly connected to the
public low-voltage power supply
network that supplies buildings
used for domestic purposes.
Electromagnetic immunity
The Nio Color 2MP 23" is intended for use in the electromagnetic environment specified below. The customer
or the user of the Nio Color 2MP 23" should assure that it is used in such an environment.
Immunity test
Electrostatic discharge
(ESD)
IEC 61000-4-2
Electrical fast transient/
burst
IEC 61000-4-4
Surge
IEC61000-4-5
Voltage dips, short
interruptions and voltage
variations on power supply
input lines
IEC 61000-4-11
IEC 60601 test levels
± 8 kV contact
± 2 kV, ± 4 kV, ± 8 kV, ± 15
kV air
± 2 kV for power supply
lines
± 1 kV for input/ output
lines
100 kHz repetition
frequency
Line to line: ± 0.5 kV, ± 1
kV
Line to ground: ± 0.5 kV, ±
1 kV, ± 2 kV
0% residual voltage for 0.5
period at 0°, 45°, 90°,
135°, 180°, 225°, 270°
and 315°
Compliance level
± 8 kV contact
± 2 kV, ± 4 kV, ± 8 kV, ± 15
kV air
± 2 kV for power supply
lines
± 1 kV for input/ output
lines
100 kHz repetition
frequency
Line to line: ± 0.5 kV, ± 1
kV
Line to ground: ± 0.5 kV, ±
1 kV, ± 2 kV
0% residual voltage for 0.5
period at 0°, 45°, 90°,
135°, 180°, 225°, 270°
and 315°
Electromagnetic
environment – guidance
Floors should be wood,
concrete or ceramic tile. If
floors are covered with
synthetic material, the
relative humidity should be
at least 30%
Mains power quality
should be that of a typical
commercial or hospital
environment
Mains power quality
should be that of a typical
commercial or hospital
environment
Mains power quality
should be that of a typical
commercial or hospital
environment. If the user of
the Nio Color 2MP 23"
K5902134 /04 Nio Color 2MP 23"29
Page 30
Important information
Immunity test
Power frequency (50/60
IEC 60601 test levels
0% residual voltage for 1
period at 0°
70% residual voltage for
25 periods at 0°
Voltage interruptions: 0%
residual voltage for 250
periods at 0°
30 A/mNot applicable
Compliance level
0% residual voltage for 1
period at 0°
70% residual voltage for
25 periods at 0°
Voltage interruptions: 0%
residual voltage for 250
periods at 0°
Hz) magnetic field
IEC 61000-4-8
Conducted RF
IEC 61000-4-6
3 Vrms (6 Vrms in ISM
bands)
3 Vrms (6 Vrms in ISM
bands)
150 kHz to 80 MHz
Radiated RF
IEC 61000-4-3
3 V/m
80 MHz to 2.7 GHz
3 V/m
Immunity to RF wireless communications equipment
Test
frequency
(MHz)
Band (MHz)
ServiceModulation
Maximum
power (W)
Electromagnetic
environment – guidance
requires continued
operation during power
mains interruptions, it is
recommended that the Nio
Color 2MP 23" be
powered from an
uninterruptible power
supply or a battery
1
Power frequency
magnetic fields should be
at levels characteristic of a
typical location in a typical
commercial or hospital
environment
-
Distance
(m)
Immunity
test level (V/
m)
385380 – 390TETRA 400Pulse
modulation
18 Hz
450430 – 470GMRS 460,
FRS 460
FM ± 5 kHz
deviation
1 kHz sine
710704 – 787LTE Band
745
13, 17
Pulse
modulation
217 Hz
780
810800 – 960GSM 800/
870
930
900, TETRA
800, iDEN
820, CDMA
850, LTE
Pulse
modulation
18 Hz
Band 5
17201700 – 1990GSM 1800,
1845
1970
CDMA 1900,
GSM 1900,
DECT, LTE
Band 1/3/4/
Pulse
modulation
217 Hz
25, UMTS
24502400 – 2570Bluetooth,
WLAN,
802.11 b/g/n,
Pulse
modulation
217 Hz
RFID 2450,
LTE Band 7
1.80.327
20.328
0.20.39
20.328
20.328
20.328
1:Nio Color 2MP 23" doesn’t contain susceptible components to magnetic fields
K5902134 /04 Nio Color 2MP 23"30
Page 31
E352529
S&E
Important information
Test
frequency
(MHz)
52405100 – 5800W LAN
5500
5785
Band (MHz)
802.11 a/n
ServiceModulation
Pulse
modulation
217 Hz
Maximum
power (W)
0.20.39
Distance
5.6 Explanation of symbols
Symbols on the device
On the device or power supply, you may find the following symbols (nonrestrictive list):
Indicates compliance with Part 15 of the FCC rules (Class A or Class B)
Indicates the device is approved according to the UL regulations
Indicates the device is approved according to the UL regulations for Canada and US
(m)
Immunity
test level (V/
m)
Indicates the device is approved according to the UL regulations for Canada and US
Indicates the device is approved according to the UL Demko regulations
Indicates the device is approved according to the CCC regulations
Indicates the device is approved according to the VCCI regulations
Indicates the device is approved according to the KC regulations
Indicates the device is approved according to the BSMI regulations
Indicates the device is approved according to the PSE regulations
Indicates the device is approved according to the EAC regulations
K5902134 /04 Nio Color 2MP 23"31
Page 32
yy
xx
SN
REF
Important information
Caution: Federal law (United Stated of America) restricts this device to sale by or on
the order of a licensed healthcare practitioner.
Indicates the USB connectors on the device
Indicates the DisplayPort connectors on the device
Indicates the legal manufacturer
Indicates the manufacturing date
Indicates the temperature limitations2for the device to safely operate within specs
Indicates the device serial number
Indicates the device part number or catalogue number
Warning: dangerous voltage
Caution
Consult the operating instructions
Indicates this device must not be thrown in the trash but must be recycled, according
to the European WEEE (Waste Electrical and Electronic Equipment) directive
Indicates Direct Current (DC)
Indicates Alternating Current (AC)
Stand-by
Equipotentiality
Protective earth (ground)
or
2:Values for xx and yy can be found in the technical specifications paragraph.
K5902134 /04 Nio Color 2MP 23"32
Page 33
Symbols on the box
15
n
xx-yy Kg
-20 °C
+60 °C
xx
yy
85 %
5 %
x
yy
106 kPa
50 kPa
xx
yyy
On the box of the device, you may find the following symbols (nonrestrictive list):
Indicates a medical device that can be broken or damaged if not handled carefully
when being stored.
Indicates a medical device that needs to be protected from moisture when being
stored.
Indicates the storage direction of the box. The box must be transported, handled and
stored in such a way that the arrows always point upwards.
Indicates the maximum number of boxes to be stacked on each other.
Indicates that the box should be carried with two persons.
Indicates that the box should not be cut with a knife, a cutter or any other sharp object.
Indicates the temperature limits to which the medical device can be safely exposed
when being stored.
Important information
Indicates the range of humidity to which the medical device can be safely exposed
when being stored.
Indicates the range of atmospheric pressure to which the medical device can be safely
exposed when being stored.
5.7 Legal disclaimer
Disclaimer notice
Although every attempt has been made to achieve technical accuracy in this document, we assume no
responsibility for errors that may be found. Our goal is to provide you with the most accurate and usable
documentation possible; if you discover errors, please let us know.
Barco software products are the property of Barco. They are distributed under copyright by Barco NV or Barco
Inc., for use only under the specific terms of a software license agreement between Barco NV or Barco Inc.
and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is
authorized.
The specifications of Barco products are subject to change without notice.
Trademarks
All trademarks and registered trademarks are property of their respective owners.
Copyright notice
This document is copyrighted. All rights are reserved. Neither this document, nor any part of it, may be
reproduced or copied in any form or by any means - graphical, electronic, or mechanical including
photocopying, taping or information storage and retrieval systems - without written permission of Barco.