Barco MDRC-2122 WP, MDRC-2122 BL, MDRC-2122 TS User Manual

Page 1
Eonis
User Guide
22–inch clinical display
MDRC-2122 WP
MDRC-2122 BL
MDRC-2122 TS
K5903049/05 25/06/2015
Page 2
PrintedinBelgium
Page 3
Table of contents
TABLE OF CONTENTS
1. Welcome! ......... ................................................................... .............. 3
1.1 About the product ............................................................................................. 3
1.2 Symbols........................................................................................................ 4
1.3 What’s in the box.............................................................................................. 4
2. Parts, controls and connectors .... ........................................................... 5
2.1 Front view...................................................................................................... 5
2.2 Rear view ............. ................ ................ ................ ................ ................ ......... 6
3. Display installation .... .................................................................... ...... 7
3.1 Unlocking the height mechanism............................................................................ 7
3.2 Adjusting the display position....... ................ ................ ................ ................ ......... 7
3.3 Removing the cover ......... ................ ................ ................ ................ ................ . 8
3.4 Connecting the cables........................................................................................ 8
3.5 Re-attaching the cover ....................................................................................... 9
3.6 Routing the cables ............... ................ ................ ................ ................ ............. 9
3.7 Kensington security slots.....................................................................................10
3.8 VESA-mount installation .....................................................................................10
4. Daily operation .. ................................................................... .............. 13
4.1 Recommendations for daily operation ................... ................ ................ ................ ...13
4.2 On/Off switching...................... ................ ................ .................. ................ .......14
4.3 Bringing up the OSD menus .......... ................ ................ ................ ................ .......14
4.4 Navigating through the OSD menus ..... ................ ................ ................ ................ ...14
5. Advanced operation ........... .................................................................. 15
5.1 Video input source selection.................................................................................15
5.2 Luminance adjustment ........ ................ ................ ................ .................. .............15
5.3 Gamma selection .............................................................................................15
5.4 Ambient light reading room selection .......................................................................16
5.5 White point selection..........................................................................................16
5.6 Analog video settings.................. ................ ................ ................ ................ .......17
5.7 OSD menu language .... ................ ................ .................. ................ ................ ...17
5.8 Power status LED.............................................................................................18
5.9 DPMS mode ........ ................ ................ ................ ................ ................ ...........18
5.10 Self calibration frequency ....................................................................................18
5.11 Factory reset............ ................ ................ ................ ................ ................ .......19
6. Maintenance ..................... ............................................................ ...... 21
6.1 Cleaning instructions .........................................................................................21
7. Important information ................ ........................................................... 23
7.1 Safety information...... .................. ................ ................ ................ ................ .....23
7.2 Environmental information ...................................................................................25
7.3 Regulatory compliance information .......... ................ ................ ................ ............... 27
7.4 EMC notice ... ................ ................ ................ ................ ................ ................ .28
7.5 Explanation of symbols .............. .................. ................ ................ ................ .......31
7.6 Legal disclaimer ...............................................................................................34
7.7 Technical specications ......................................................................................34
K5903049 EONIS 25/06/2015
1
Page 4
Table of contents
2 K5903049 EONIS 25/06/2015
Page 5
1. Welcome!
1. WELCOME!
1.1 About t he product
Consistent image quality
The Eonis display presents crisp, razor-sharp, high-contrast images. To guarantee image consistency at all times, it features a unique front sensor that automatically aligns image quality every time the display is turned on. This image consistency enhances collaboration: images always appear exactly like they are supposed to, on every display, which spurs condent clinical decisions. Furthermore, specialists looking at X-ray images will appreciate the built-in DICOM settings.
One-click quality assurance
Like Barco’s entire medical display range, the Eonis display line comes with Barco’s online MediCal QAWeb service for quality assurance and remote asset management. Proving its superior value in hospitals around the world, MediCal QAWeb provides automated quality assurance checks and detailed reports. It makes it easy for healthcare IT to centrally and remo the healthcare organization. Also for private practices, QAWeb further strengthens image consistency and allows you to easily personalize your image.
tely manage and congure displays across
Fully cleanable and smart design
The Eonis display carries all safety certications required in clinical environments. It features an inte­grated cable management system, making it safe to use in hospitals and private practices. The multi­ple mounting options and connections further add to the smart design typical of Barco’s Eonis display. Most unique, however, is the excellent cleanability of the white Eonis display thanks to the toughened and scratch-proof glass. This display model can be disinfected, both front and back, with typical alcohol-based cleaning agents.
Features
Front sensor automatically aligns image quality
IPS panel ensures wide viewing angle
MediCal QAWeb suite for networked quality assurance, calibration and asset management all add to the exceptional, consistent image quality of the Eonis display
Toughened, scratch-proof front glass (white v
Covered cables
Medical-grade certications
Sockets for Kensington lock makes the Eonis display safe for use in clinical environments
Flexible VESA mount for easy arm, wall or cart mounting
Top connections for easy and secure connections
Multiple inputs (HDMI, DisplayPort, USB, etc.) ensure the display’s exible deployment
This manual further guides you through the different steps needed to install and use the Eonis display.
ersion only)
CAUTION: Read all the important safety information before installing and operating your
Eonis display. Please refer to the dedicated chapter in this user guide.
K5903049 EONIS 25/06/2015 3
Page 6
1. Welcome!
1.2 Symbols
Symbols in this document
The following symbols are used in this document:
Caution
Warning
Info, term denition. General info about the term
Note: gives extra information about the described subject
Tip: gives extra advice about the described subject
1.3 What’s in the box
Overview
Your Eonis display comes with:
this Eonis display user guide
a documentation CD containing multilingual user documentation
a system CD containing MediCal QAWeb Agent
a (set of) AC power cord(s) (depending on the region of operation)
•aHDMIcable
a DisplayPort cable
a USB cable
an external power supply
an accessory bag (cleaning cloth, velcro cable routing strap)
Keep y our original packaging. It is designed for this display and is the ideal protection during transport and storage.
4 K5903049 EONIS 25/06/2015
Page 7
2. Parts, controls and connectors
2. PARTS, CONTROLS AND CONNECTORS
2.1 Front view
Overview
1 2 76543
Image 2-1
1. Front sensor
2. USB downstream connector
3. Left / Decrease key
4. Right / Increase key
5. Menu / Enter key
6. Standby key
7. Power status LED
K5903049 EONIS 25/06/2015
5
Page 8
2. Parts, controls and connectors
2.2 Rear view
Overview
1
2
3
Image 2-2
1. Connector compartment cover
2. Kensington security slots
3. Opening for cable routing strap
4. Height mechanism lock screw
5. VGA input
6. HDMI audio line out
7. USB downstream connector
8. USB upstream connector
9. HDMI input
10. DisplayPort input
11. +12 VDC (
) power input
2
4 5 6 7 8 9 10 11
6
K5903049 EONIS 25/06/2015
Page 9
3. Display installation
3. DISPLAY INSTALLATION
3.1 Unlocking the height mechanism
To unlock the height mechanism
In the factory, the height mechanism in the stand of your Eonis display is locked to prevent damage dur­ing transportation. You’ll rst have to unlock this mechanism before you can adjust your display height position.
To unlock the height mechanism, unscrew the height mechanism lock screw and remove it from the d stand.
Keep the lock screw in a known place for possible future transportation of your display.
Image 3-1
3.2 Adjusting the display position
To adjust the display position
After unlocking the height mechanism, you can n desired.
ow safely tilt, swivel, raise and lower your display as
isplay
K5903049 EONIS 25/06/2015
7
Page 10
3. Display installation
Image 3-2
CAUTION: Do not try to pivot your display when a ttached to the stand. Trying to do so
could cause serious damage to your display and its stand.
3.3 Removing t he cover
To remove the connector compartment cover
The connector compartment cover should be removed to get access to the connectors. To remove the cover, gently slide the connector compartment cover upwards and remove it from the display.
Image 3-3
3.4 Connecting t he cables
To connect the cables
1. Connect one or more of the video input connections of your display (VGA, HDMI or DisplayPort) to the
corresponding video outputs on your computer or any other video device.
2. If you want to make use of the
with the display’s USB upstream connector by means of the supplied USB cable.
3. Connect a speaker, amplier, ... with the display’s audio line out if you want to use the internal sound
option of your display.
8
display’s USB downstream connectors, then connect your workstation
K5903049 EONIS 25/06/2015
Page 11
3. Display installation
4. Connect the supplied external DC ( ) power supply to the +12 VDC power input of your display.
5. Plug the other end of the external DC (
the proper power cord delivered with your display.
1 1 4
Image 3-4
23 1
) power supply into a grounded power outlet by means of
5
3.5 Re-attaching the cover
To re-attach the c onnector compartment cover
Put the cover back in position by sliding it downwards so that it is xed to the display again.
Pay attention that all cables stay in the cable channel while re-attaching the cover.
Image 3-5
3.6 Routing the cab les
To route the cables
1. Slide the cable routing strap through the opening in the back of the stand.
2. Bundle all cables together so that they will t in the strap.
K5903049 EONIS 25/06/2015
9
Page 12
3. Display installation
3
2
3. Wrap and x the cable routing strap around all cables.
Image 3-6
3.7 Kensington security slots
To make use of the Kensington security slots
Your Eonis display has 2 Kensington slots available which allow you to secure the display to a desk or any other xed object. Moreover, when locking the display with the connector compartment cover attached, you also prevent users from connecting/disconnecting any cables to/from the display.
Image 3-7
3.8 VESA-mount installation
To mount the display on a VESA arm
The display panel, standard attached to a stand, is compatible with the VESA 75 mm standard.
1. Unscrew the four xation screws to detach the panel from the stand.
2.Use4M4screwstoattachthep
screws is 10mm + VESA plate thickness (tolerance of +/- 1 mm).
10
anel to a VESA approved arm. Please make sure that the length of the
K5903049 EONIS 25/06/2015
Page 13
Image 3-8
3. Display installation
CAUTION: Use an arm that can support a weight of at least 12 kg (26.50 lbs). Failure to
do so could make the panel fall, causing serious injury to a child or adult, and serious damage to the equipment.
CAUTION: Never move a display attached to an arm by pulling or pushing the display
itself. Instead, make sure that the arm is equipped with a VESA approved handle and use this to move the display. Please refer to the instruction manual of the arm for more information and instructions.
K5903049 EONIS 25/06/2015 11
Page 14
3. Display installation
12 K5903049 EONIS 25/06/2015
Page 15
4. Daily operation
4. DAILY OPERATION
4.1 Recommendations for d aily operation
Optimize the lifetime of your display
Enabling the Display Power Management System (DPMS) of your display will optimize its lifetime by auto­matically switching off the backlight when the display is not used for a specied period of time. By default, DPMS is enabled on your display, but it also needs to be activated on your workstation. To do this, go to “Power Options Properties” in the “Control Panel”.
Barco recommends setting DPMS activation after 20 minutes of non-usage.
Use a screen saver to avoid image retention
Prolonged operation of an LCD with the same content on the same screen area may result in a form of image retention.
You can avoid or signicantly reduce the occurrence of this phenomenon by using a screen saver. You can activate a screen saver in the “Display properties” window of your workstation.
Barco recommends setting screen saver activation after 5 minutes of non-usage. A good screen saver displays moving content.
In case you are working with the same image or an application with static image elements for several hours continuously (so that the screen saver is not activated), change the image content regularly to avoid image retention of the static elements.
Understand pixel technology
LCD displays use technology based on pixels. As a normal tolerance in the manufacturing of the LCD, a limited number of these pixels may remain either dark or permanently lit, without affecting the performance of the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels.
To learn more about LCD technology and missing pixels, consult the dedicated white papers available at w
ww.barco.com/healthcare.
Maximize quality assurance
QAWeb guarantees optimum and stabilized image quality in every private practice.
The front sensor on the Eonis display works seamlessly with QAWeb to ensure a consistent image over time. It automatically stabilizes the image from the moment you switch on the display. What’s more, QAWeb provides you with instant feedback on the status of the display.
K5903049 EONIS 25/06/2015
13
Page 16
4. Daily operation
4.2 On/Off switching
To switch your display on or off
1. Shortly press the Standby ( )key.
4.3 Bringing up the OSD menus
About the OSD menu
TheOSDmenuallowsyoutoconfigure different settings to make your Eonis display fit your needs within your working environment. Also, you can retrieve general information about your display and it conguration settings through the OSD menu.
To bring up the OSD menu
1. While the display is switched on, press the Menu/Enter ( )key.
As a result, the OSD main menu comes up in the middle of the screen. If no further actions are taken within the following 10 seconds however, the OSD menu will disappear again.
s current
4.4 Navigating through the OSD menus
To navigate through the OSD menus
1. Use the Right/Down ( ) and Left/Up ( ) keys to move through the (sub)menus, change values or
make selections.
2. To go into a submenu or conrm adjustments and selections, use the Menu/Enter (
)key.
14
K5903049 EONIS 25/06/2015
Page 17
5. Advanced operation
5. ADVANCED OPERATION
5.1 Video input source selection
About video input source selection
By default, your Eonis display automatically detects and shows the connected video input source. How­ever, when for instance more then one video input source is connected, it may be needed to manually select the input source to be displayed.
The available video input source selections for your display are:
Auto: This is the default setting and will automatically detect and display the connected video input
source.
HDMI: This setting will display the video connected to the HDMI input.
DisplayPort: This setting will display the video connected to the DisplayPort input.
VGA: This setting will display the video connected to the VGA input.
To select a video input source
1. Bring up the OSD main menu.
2. Navigate to the Input Selection menu.
3. Select one of the available video input sources.
5.2 Luminance adjustment
About luminance adjustment
The luminance of your Eonis display is adjustable over a predened range. When you change the lumi­nance, the display will adjust its backlight to reach the target.
To adjust the luminance
1. Bring up the OSD main menu.
2. Navigate to the Adjustments menu.
3. Enter the Luminance submenu.
4. Set a luminance value as desired and conrm.
5.3 Gamma selection
About gamma selection
Native, uncorrected panels will display all grayscale/color levels with equal luminance increments. Studies have shown however, that in medical images certain grayscale/color parts contain more relevant informa­tion than others. To respond to these conclusions, gamma functions have been dened. These functions emphasize on these parts containing crucial information by correcting the native panel behavior.
The available gamma functions for your display are:
K5903049 EONIS 25/06/2015
15
Page 18
5. Advanced operation
Native:IfyouselectNative, the native panel behavior will not be corrected.
sRGB:Thisisthedisplayfunctionasdefined in the sRGB specificationandisdesignedtomatch
typical home and ofce viewing conditions. It is widely used in most computer applications.
DICOM: DICOM (Digital Imaging and Communications in Medicine) is an international standard that
was developed to improve the quality and communication of digital images in radiology. In short, the DICOM gamma function results in more visible grayscales in the images. Barco recommends selecting the DICOM gamma function for most medical viewing applications.
Gamma 2.2: Select this function in case the display is to replace a CRT display with a gamma of 2.2.
QAWeb: This gamma function will be automatically selected when gamma functions are dened by
MediCal QAWeb.
To select a gamma function
1. Bring up the OSD main menu.
2. Navigate to the Adjustments menu.
3. Enter the Gamma submenu.
4. Select one of the available gamma functions.
5.4 Ambient light reading room selection
About ambient light reading rooms
The available ambient light reading rooms for your display are:
Dark Room: Corresponds to light conditions in dark diagnostic reading rooms. This setting has the
lowest maximum ambient light.
Ofce: Corresponds to light conditions in ofce rooms.
Operation Room: Corresponds to light conditions in operating rooms. This setting has the highest
maximum ambient light.
QAWeb: This setting will be automatically selected when ambient li
iCal QAWeb.
ght conditions are dened by Med-
To select an ambient light reading room
1. Bring up the OSD main menu.
2. Navigate to the Adjustments menu.
3. Enter the Ambient Light submenu.
4. Select one of the available reading rooms and conrm.
5.5 White p oint selection
About white point selection
This setting allows you to modify the display white point, used as reference for all other colors to be dis­played.
The available white point settings for your display are:
Native: The native, unmodied color temperature of the LCD panel.
6500K (sRGB): Corresponds to a color temperature of 6500 Kelvin (D65).
QAWeb: This white point setting will be automatically selected when white point is dened by
MediCal QAWeb.
16
K5903049 EONIS 25/06/2015
Page 19
5. Advanced operation
To select the white point
1. Bring up the OSD main menu.
2. Navigate to the Adjustments menu.
3. Enter the White Point submenu.
4. Select one of the available white point presets.
5.6 Analog video settin gs
The following settings are only available when VGA video input source is selected.
About analog video settings
When the VGA video input source is active, a number of analog video settings will become available:
Auto Adjust: The analog video setting will automatically be adjusted
Geometry: Allows to manually adjust the geometry settings of the analog video (clock frequency, clock
phase, horizontal position, vertical position)
Level: Allows to manually adjust the contrast and brightness levels of the analog video
To adjust the analog video settings
1. Bring up the OSD main menu.
2. Navigate to the Adjustments menu.
3. Enter the Analog submenu.
4. Adjust one of the available analog video settings as desired.
5.7 OSD menu language
About the OSD menu language
By default, the OSD menu comes up in English. However, there’s a wide range of other languages avail­able for the OSD menu of your Eonis display:
•English
French
•German
Spanish
Italian
•Dutch
To select the language of the OSD menu:
1. Bring up the OSD main menu.
2. Navigate to the Adjustments > Settings menu.
3. Enter the Language submenu.
4. Select one of the available languages.
K5903049 EONIS 25/06/2015
17
Page 20
5. Advanced operation
5.8 Power s tatu s LED
About the power status LED
By default, the power status LED has the following behavior:
Green: Displayison
Blinking green: Display is entering standby power-saving mode
Orange: Display is in standby power-saving mode
Off: Display is disconnected from the mains power
This default behavior can be changed so that the power status LED is also off when the display is on or when the display is entering standby power-saving mode.
To change the behavior of the po wer status LED:
1. Bring up the OSD main menu.
2. Navigate to the Adjustments > Settings menu.
3. Enter the Power Status LED submenu.
4. Change the behavior of the power status LED as desired and conrm.
The orange standby power-saving state of the LED is not inuenced by this setting. So, when the display is in standby power-saving mode, the LED w ill turn orange, even if it was switched off by this setting.
5.9 DPMS mode
About DPMS mode
Enabling the Display Power Management System (DPMS) mode on your Eonis display will optimize the displays’ lifetime by automatically switching off the backlight when no video signal is detected for approx­imately 10 seconds. The power status LED will then turn orange.
To enable/disable DPMS mode
1. Bring up the OSD main menu.
2. Navigate to the Adjustments > Settings > Power Save menu.
3. Enter the DPMS submenu.
4. Select On or Off as desired and conrm.
5.10 Self calibration frequency
About self calibration
The front sensor of your Eonis display measures the output luminance of your screen and allows the display to automatically stabilize its luminance for maximum image quality over the displays’ lifetime. This self calibration is done at an adjustable, predened frequency:
18
K5903049 EONIS 25/06/2015
Page 21
5. Advanced operation
1min
1hr
6hr
24 hr
Never
QAWeb: This setting will be automatically selected when the self calibration frequency is dened by
MediCal QAWeb.
To adjust the self calibration frequency
1. Bring up the OSD main menu.
2. Navigate to the Adjustments > Settings menu.
3. Enter the Self Calibration Frequency submenu.
4. Select one of the available frequency presets.
5.11 Factory reset
About factory reset
A factory reset allows you to fully restore the display to its original factory setting.
To perform a factory reset
1. Bring up the OSD main menu.
2. Navigate to the Adjustments > Settings menu.
3. Enter the Factory Reset submenu.
4. Select Yes or No as desired and conrm.
K5903049 EONIS 25/06/2015
19
Page 22
5. Advanced operation
20 K5903049 EONIS 25/06/2015
Page 23
6. Maintenance
6. MAINTENANCE
General maintenance information
The Eonis display does not require any scheduled maintenance or calibration activities. We recommend to use QAWeb with the Barco default tests and frequencies to calibrate and maintain the display or return the display to a Barco approved maintenance organization. In any case of doubts, contact the Barco Healthcare D ivision.
6.1 Cleaning instructions
To clean the display
Clean the display using a sponge, cleaning cloth or soft tissue, lightly moistened with a rec ing product for medical equipment. Read and follow all label instructions on the cleaning product. In case of doubt about a certain cleaning product, use plain water.
Do not use following products:
For black model; alcohol/solvents at higher concentration > 5%, for white model; alcohol/solvents at
higher concentration > 70%
Strong alkalis lye, strong solvents
•Acid
Detergents with uoride
Detergents with ammonia
Detergents with abrasives
Steel wool
Sponge with abrasives
Steel blades
Cloth with steel thread
ognized clean-
CAUTION: Take care not to damage or s cratch the front glass or LCD. Be careful w ith
rings or other jewelry and do not apply excessive pressure on the front glass or LCD.
CAUTION: For black model only: Do not apply or spray liquid directly to the display as
excess liquid may cause damage to internal electronics. Instead, apply the liquid to a cleaning cloth.
K5903049 EONIS 25/06/2015 21
Page 24
6. Maintenance
22 K5903049 EONIS 25/06/2015
Page 25
7. IMPORTANT INFORMATION
7.1 Safety information
General recommendations
Read the safety and operating instructions before operating the device.
Retain safety and operating instructions for future reference.
Adhere to all warnings on the device and in the operating instructions manual.
Follow all instructions for operation and use.
Electrical Shock or Fire Hazard
To prevent electric shock or re hazard, do not remove cover.
No serviceable parts inside. Refer servicing to qualied personnel.
Do not expose this apparatus to rain or moisture.
7. Important information
Modications to the unit:
Do not modify this equipment without authorization of the manufacturer.
Type of protection (electrical):
Display with external power supply: Class I equipment.
Degree of safety (ammable anesthetic mixture):
Equipment not suitable for use in the presence of a ammable anesthetic mixture or nitrous oxide.
with air or with oxygen
Non-patient care equipment
Equipment primarily for use in a health care facility that is i
is unlikely (no applied part).
The equipment may not be used with life support equipment.
The user should not touch the equipment, nor its signal input por
and the patient at the same time.
Power connection – Equ ipment with external 12 V DC power suppl
Power requirements: The equipment must be powered using the d
(
) power supply.
The medical approved DC (
The power supply is specied as a part of the ME equipme
system.
To avoid the risk of electric shock, this equipment must only be connected to a supply mains with
protective earth.
The equipment should be installed near an easily accessible outlet.
The equipment is intended for continuous operation.
) power supply must be powered by the AC mains voltage.
ntended for use where contact with a patient
ts (SIP)/signal output ports (SOP)
y
elivered medical approved 12 VDC
nt or combination is specied as a ME
Transient over-voltage
If the device is not used for a long time, disconnect it from the AC inlet to avoid damage by transient over-voltage.
K5903049 EONIS 25/06/2015
23
Page 26
7. Important information
To fully disengage the power to the device, please disconnect the power cord from the AC inlet.
Power cords:
Do not overload wall outlets and extension cords as this may result in re or electric shock.
Mains lead protection (U.S.: Power cord): Power cords should be routed so that they are not likely to
be walked upon or pinched by items placed upon or against them, paying particular attention to cords at plugs and receptacles.
The power supply cord should be replaced by the designated operator only at all time.
Use a power cord that matches the voltage of the power outlet, which has been approved and complies
with the safety standard of your particular country.
Grounding reliability
Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked “Hospital Only” or “Hospital Grade” (located on product or power supply cord)
External equipment
External equipment intended for connection to signal input/output or other connectors, shall comply with relevant UL/ EN/ IEC standard (e.g. UL/EN/IEC 60950 for IT equipment and UL/EN 60601-1 / IEC 60601 series for medical electrical equipment). In addition, all such combinations -systems- shall comply with the standard IEC 60601-1-1, safety requirements for medical electrical systems. Equipment not complying with UL/EN / IEC 60601-1 shall be kept outside the patient environment, as dened in the standard.
Equipment not complying with IEC 60601 must be kept outside the patient envi standard as at least 1.5 meters from the patient or the patient support.
Any person who connects external equipment to signal input, signal output, or other connectors has formed a system and is therefore responsible for the system to comply with the requirements of IEC 60601-1-1. If in doubt, speak with a qualied technician.
In locations where 240 V outlets are used, connect this display only on a ce phase supply .
ronment, as denedinthe
nter-tapped, 240 V, single-
Water and moisture
Never expose the device to rain or moisture. Never use the device near water - e.g. near a bathtub, washbasin, swimming pool, kitchen sink, laundry tub or in a wet basement.
IP-x level for MDRC-2122 BL: Ordinary
IP-x level for MDRC-2122 WP and MDRC-2122 TS: Protection glass, IP32
Ventilation
Do not cover or block any ventilation openings in the cover o cupboard or another closed location, heed the necessary space between the set and the sides of the cupboard.
f the set. When installing the device in a
Installation
Place the device on a at, solid and stable surface that can support the weight of at least 3 devices. If you use an unstable cart or stand, the device may fall, causing serious injury to a child or adult, and serious damage to the device.
This apparatus conforms to:
CE (MDD 93/42/EEC class I product), CE-2004/108/EC, 2014/30/EU (Directive 2004/108/EC is repealed with effect from 20 April 2016), IEC 60950-1:2 + A1:1991 + A2:1995, IEC 60601-1:2005 + A1:2012, ANSI/AAMI ES 60601-1:2005 + C1:2009 + A1:2012, CAN/CSAC22.2 No. 60601-1-08:2008, DEMKO - EN 60601- 1:2006, EN 60601-1-2:2007, EN 60601­1:2006+A11:2011, CCC - GB9254-2008 + GB4943-2001 + GB17625.1-2003 (MDRC-2122 BL and MDRC­2122 WP only), KC, VCCI, FCC class B, ICES-001 Level B, FDA Class I device, RoHS
24
005 + A1:2009 (2ND EDITION), IEC 60601-1 2ND ED:1988
K5903049 EONIS 25/06/2015
Page 27
7. Important information
National Scandinavian Deviations for CL. 1.7.2:
Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan"
Norway: "Apparatet må tilkoples jordet stikkontakt"
Sweden: "Apparaten skall anslutas till jordat uttag"
Essential performance
Barco states that the Eonis display is only used for reviewing medical digital images. These reviews are done in rooms where the equipment is unlikely to be in contact with patients. With this information, if the display fails, the patient is not in direct danger for harm. If, by some reason, the display would fail there would be no danger towards the operator working with it. Also the Eonis display has no articial intelligence and doesn’t manipulate the image information. If something would fail in the display, ex. no image on the screen, the medical staff will notice this directly. Some other risks are less obvious, for example image artifacts introduced by the display. However, as the display is only intended to be used for reviewing medical digital images, indirect danger towards the patient isn’t there. With this information, the Eonis display has no essential performance.
7.2 Environmental information
Disposal Information
Waste Electrical and Electronic Equipment
This symbol on the product indicates that, under the European Directive 2012/19/EU governing waste from electrical and electronic equipment, this product must not be disposed of with other municipal waste. Please dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. To p human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
For more information about recycling of this product, please contact your local city ofce or your municipal waste disposal service.
For details, please visit the Barco website at: h
ttp://www.barco.com/en/AboutBarco/weee
revent possible harm to the environment or
Turkey RoHS compliance
Türkiye Cumhuriyeti: AEEE Yönetmeliğine Uygundur.
[Republic of Turkey: In conformity with the WEEE Regulation]
中国大RoHS
Chinese Mainland RoHS
根据中国大陆《电子信息产品污染控制管理法》(也称中国大RoHS), 以下部分列出了Barco产品 中可能包含的有毒和/或有害物的名称和含量。中国大RoHS指令包含在中国信息产业MCV准:
子信息品中有毒物的限量要求中。
According to the “China Administration on Control of Pollution Caused by Electronic Information Products” (Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements of toxic substances in Electronic Information Products”.
K5903049 EONIS 25/06/2015
25
Page 28
7. Important information
零件目(名称)
Component name
印制路配件
Printed Circuit Assemblies
液晶面板
LCD panel 外接电(线)
External Cables
线
Internal wiring
金属外壳
Metal enclosure
塑胶外壳
Plastic enclosure ()
Heatsinks
源供
有毒有害物或元素
Hazardous substances and elements
Pb
X
X
X
OO O O OO
OO O O OO
OO O O OO
OO O O OO
X
Hg
OOOOO
OOOOO
OOOOO
OOOOO
Cd
Cr6+
溴联
PBB
二苯
PBDE
Power Supply Unit
Fan
文件说明书
Paper Manuals
盘说
CD manual 个表被制按照定SJ/T 11364.
This table is prepared in accordance with the provisions of SJ/T 11364.
O: 表示有毒有害物部件所有均材料中的含量均在 SJ/T 11363 定的限量要求
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363.
X: 表示有毒有害物至少在部件的某一均材料中的含量超出 SJ/T 11363 定的限量要求.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T1 1363.
在中国大陆销售的相应电子信息品(EIP)都必遵照中国大子信息染控制标识要求》保使用期限(EFUP)标签。Barco品所采用的EFUP标签(阅实例,徽内部的号使用于制 品)基于中国大的《子信息保使用期限通准。
All Electronic Information Products (EIP) that are sold within Chinese Mainland must comply with the “Electronic Information Products Pollution Control Labeling Standard” of Chinese Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses (please refer to the photo) is based on the “Standard of Electronic Information Products Environmental Friendly Use Period” of Chinese Mainland.
OO O O OO
OO O O OO
OO O O OO
以下.
26
K5903049 EONIS 25/06/2015
Page 29
7. Important information
10
ChinaEnergyLabel
If there is a China Energy Label on your packaging or product, the product meets the following energy requirements corresponding with the energy efciency level on the label.
按照中国 << 能源效率标识管理>>
In accordance with The Regulation of the Implementation on China Energy Label
能源效率等
Energy Efciency Level
能源效率
Energy Efciency (cd/W)
关闭状态能耗
Energy Consumption in off mode (W)
行的能源效率国家
Code of National Standard applied
示器符合以下要求
This monitor is compliant with the following requirements
12
>1.05 >0.85
<0.5 <1.0
GB 21520 GB 21520
示器符合以下要求
This monitor is compliant with the following requirements
7.3 Regulatory compliance information
Indications for use
This display is an AMLCD display designed for viewing medical X-ray images. This unit should not be used near patients (where patients are likely to be in unconscious condition) and should be kept outside of 1.83 m perimeter and 2.29 m vertical.
FCC class B
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference re­ceived, including interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the device and receiver.
Connect the device into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
K5903049 EONIS 25/06/2015
27
Page 30
7. Important information
Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Canadian notice
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à la norme NMB-001 du Canada.
7.4 EMC notice
General information
No specic requirement on the use of external cables or other accessories except power supply.
With the installation of the device, use only the delivered power supply or a spare part provided by the legal manufacturer. Using another can result in a decrease of the immunity level of the device.
Electromagnetic emissions
The Eonis display is intended for use in the electromagnetic environment specied below. The customer or the user of the Eonis display should assure that it is used in such an environment.
Emissions test
RF emissions
CISPR 11
RF emissions
CISPR 11 Harmonic emissions
IEC 61000-3-2 Voltage uctuations/ icker
emissions
IEC 61000-3-3
This Eonis display complies with appropriate medical EMC standards on emissions to, and interference from surrounding equipment. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interfer­ence that may cause undesired operation.
Interference can be determined by turning the equipment off and on.
If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding equipment, the user is encouraged to try to correct the interference by one or more of the following mea­sures:
Compliance
Group 1
Class B
Class D
Complies
Electromagnetic environment – Guidance
The Eonis display uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. The Eonis display is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.
Reorient or relocate the receiving antenna or equipment.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced technician for help.
Electromagnetic immunity
The Eonis display is intended for use in the electromagnetic environment specied below. The customer or the user of the Eonis display should assure that it is used in such an environment.
28
K5903049 EONIS 25/06/2015
Page 31
7. Important information
Immunity test
Electrostatic discharge (ESD)
IEC 61000-4-2
Electrical fast transient/burst
IEC 61000-4-4
Surge
IEC61000-4-5
Voltage dips, short interruptions and voltage variations on power supply input lines
IEC 61000-4-11
Power frequency (50/60 Hz) magnetic eld
IEC 61000-4-8
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
IEC 60601
Test levels
± 6kV contact
±8kVair
± 2kV for power supply lines
± 1kV for input/ output lines
± 1 kV line(s) to line(s)
± 2 kV line(s) to earth
<5%U U
T
40% U
1
(> 95% dip in
T
) for 0.5 cycle
(60%dipinUT)
T
for 5 cycles
70% U
(30%dipinUT)
T
for 25 cycles
<5%U U
) for 5s
T
(>95% dip in
T
3A/m
3Vrms
150 kHz to 80 MHz
3V/m
80 MHz to 2.5 GHz
Compliance level
± 6kV contact
±8kVair
± 2kV for power supply lines
± 1kV for input/ output lines
± 1 kV line(s) to line(s)
±2kVline(s)toearth
<5%U U
) for 0.5 cycle
T
40% U
(> 95% dip in
T
(60% dip in UT)
T
for 5 cycles
70% U
(30% dip in UT)
T
for 25 cycles
<5%U U
)for5s
T
Not applicable
(>95% dip in
T
2
3V
3V/m
Electromagnetic environment – guidance
Floors should be wood, concrete or ceramic tile. If oors are covered with synthetic material, the relative humidity should be at least 30%
Mains power quality should be that of a typical commercial or hospital environment
Mains power quality should be that of a typical commercial or hospital environment
Mains power quality should by that of a typical commercial or hospital environment. If the user of the Eonis display requires continued operation during power mains interruptions, it is recommended that the Eonis display be powered from an uninterruptible power supply or a battery. Power frequency magnetic elds should be at levels characteristic of a typical location in a typical commercial or hospital environment. Portable and mobile RF communications equipment should be used no closer to any part of the Eonis display, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance
d=1.2√P d=1.2√P 80 MHz to 800
MHz d=2.3P 800 MHz to 2.5
Ghz
1. is the a.c. mains voltage prior to application of the test level.
2. Eonis display doesn’t contain susceptible components to magnetic fields
K5903049 EONIS 25/06/2015 29
Page 32
7. Important information
Immunity test
IEC 60601
Test levels
Compliance level
Electromagnetic environment – guidance
Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m).
Field strengths from xed RF transmitters, as determined by an electromagnetic site survey,
3
should be less than the compliance level in each frequency
4
range.
Interference may occur in the vicinity of equipment marked with symbol:
At 80 MHz and 800 MHz, the higher frequency range applies.
These guidelines may not apply in all situations. Electromagnetic propagation is af­fected by absorption and ree ction from structures, objects and people.
Recommended separation distance
The Eonis display is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer of the user of the Eonis display can help prevent electromagnetic interfer­ence by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Eonis display as recommended below, according to the maximum output power of the communications equipment.
3. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Eonis display is used exceeds the applicable RF compliance level above, the Eonis display should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the Eonis display.
4. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than3V/m.
30 K5903049 EONIS 25/06/2015
Page 33
7. Important information
Rated maximum output power of transmitter
W
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100121223
At 80 M Hz and 800 MHz, the separation distance for the higher frequency range applies.
These guidelines may not apply in all situations. Electromagnetic propagation is af­fected by absorption and reection form structures, object and people.
Separation distance according to frequency of transmitter
5
150kHz to 80MHz d=1.2√P
80MHz to 800MHz d=1.2√P
800MHz to 2.5GHz d=2.3√P
7.5 Exp lanation of symbols
Symbols on the device
On the device or power supply, you may nd the following symbols (nonrestrictive list):
Indicates compliance with the Directive 93/42/EEC as Class I device
Indicates compliance with the Directive 93/42/EEC as
Indicates compliance with Part 15 of the FCC rules (Class A or Class B)
Indicates the device is approved according to the UL regulations
Indicates the device is approved according to the UL regulations for Canada and US
Indicates the device is approved according to the UL regulations for Canada and US
Class II device
5. For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter. Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
K5903049 EONIS 25/06/2015 31
Page 34
7. Important information
Indicates the device is approved according to the UL Demko regulations
Indicates the device is approved according to the CCC regulations
Indicates the device is approved according to the VCCI regulations
Indicates the device is approved according to the KC regulations
Indicates the device is approved according to the BSMI regulations
Indicates the device is approved according to the PSE regulations
Indicates the USB connectors on the device
Indicates the DisplayPort connectors on the device
Indicates the legal manufacturer
Indicates the manufacturing date
Indicates the temperature limitations6for the device to safely operate within specs
Indicates the device serial nu
Indicates the device part number or catalogue number
mber
Warning: dangerous voltage
Caution
6. Values for xx and yy can be found in the technical specifications paragraph.
32 K5903049 EONIS 25/06/2015
Page 35
Consult the operating instructions
Indicates this device must not be thrown in the trash but must be recycled, according to the European WEEE (Waste Electrical and Electronic Equipment) directive
Indicates Direct Current (DC)
Indicates Alternating Current (AC)
Stand-by
Equipotentiality
Symbols on the box
7. Important information
On the box of the device, you may nd the following symbols (nonrestrictive list):
Indicates a device that can be broken or damaged if not handled being stored.
Indicates a device that needs to be protected from moisture when b eing stored.
Indicates the storage direction of the box. The box must be transported, handled and stored in such a way that the arrows always point upwards.
Indicates the maximum number of identical boxes which may be stacked on each
15
n
n
other, where “n” is the limiting number.
or
Indicates that the box should be carried with two persons.
20 - 30 Kg
Indicates that the box should not be cut with a knife, a cutter or any other sharp object.
Indicates the temperature limits7to which the device can be safely exposed when
yy
xx
-20 °C
+60 °C
85 %
yy
being stored.
Indicates the range7of humidity to which the device can be safely exposed when being stored.
carefully when
x
5 %
yyy
106 kPa
Indicates the range7of atmospheric pressure to which the device can be safely exposed when being stored.
xx
50 kPa
7. Values for xx and yy can be found in the technical specifications paragraph.
K5903049 EONIS 25/06/2015 33
Page 36
7. Important information
7.6 Legal disclaimer
Disclaimer notice
Although every attempt has been made to achieve technical accuracy in this document, we assume no responsibility for errors that may be found. Our goal is to provide you with the most accurate and usable documentation possible; if you discover errors, please let us know.
Barco software products are the property of Barco. They are distributed under copyright by Barco NV or Barco Inc., for use only under the specic terms of a software license agreement between Barco NV or Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in a form, is authorized.
The specications of Barco products are subject to change without notice.
Trademarks
All trademarks and registered trademarks are property of their respective owners.
Copyright notice
This document is copyrighted. All rights are reserved. Neither this document, nor any part of it, may be reproduced or copied in any form or by any means - graphical, electronic, or mechanical including photocopying, taping or information storage and retrieval systems - without written permission of Barco.
ny
© 2015 Barco NV all rights reserved.
7.7 Technical sp ecications
MDRC-2122 BL
Product acronym
Screen technology TFT Color LCD IPS
Active screen size (diagonal) 542 mm (21.5”)
Active screen size (H x V) 267,3 mm x 475,2 mm (10.52” x 18.71”)
Aspect ratio (H:V)
Resolution
Pixel pitch 0.2475
Color imaging
Gray imaging
Color support
Viewing angle (H, V) 178°
Ambient Light Compensation (ALC) Front sensor Yes
Maximum luminance
MDRC-2122 BL
16:9
2MP (1920 x 1080)
Yes
Yes
10 bit
Yes, preset values in OSD
250 cd/m² typical
DICOM calibrated luminance 180 cd/m²
Contrast ratio
Responsetime(Tr+Tf)
Housing color
Video input signals
USB ports
USB standard
34 K5903049 EONIS 25/06/2015
1000:1 typical
14 ms
Black + Silver
VGA, DisplayPort, H DMI
1 upstream, 2 downstream
2.0
Page 37
7. Important information
Power requirements (nominal)
Power consumption (nominal) 40 W (<0,5 W in stand-by)
Power save mode Yes
Power management
Dot clock 165 MHz
OSD languages English, French, German, Spanish, Italian, Dutch
Dimensions with stand (W x H xD) Dimensions w/o stand (W x H xD) Dimensions packaged (W x H xD) Net weight with stand 6.0 kg
Net weight w/o stand
Net weight packaged with stand
Height adjustment range 80 mm
Tilt
Swivel -30° / +30°
Pivot
Mounting standard
Screen protection N/A
Certications CE (MDD 93/42/EEC class I product), CE-2004/108/EC, 2014/30/EU
Supplied accessories
Optional accessories N/A
QA software QAWeb Private Practice, QAWeb Enterprise
Warranty 3 years
Operating temperature +10°C / +40°C
Storage temperature -20°C / +60°C
Operating humidity 30% - 75% (non-condensing)
Storage humidity 5% - 85% (non-condensing)
100-240 V
DPMS
507 x 377–457x 166 mm
507 x 306 x 57 mm
610 x 505 x 230 mm
3.6 kg
9.6 kg
0° / +20°
N/A
VESA (75 mm)
(Directive 2004/108/EC is repealed with effect from 20 April 2016), IEC 60950-1:2005 + A1:2009 (2ND EDITION), IEC 60601-1 2ND ED:1988 + A1:1991 + A2:1995, IEC 60601-1:2005 + A1:2012, ANSI/AAMI ES 60601-1:2005 + C1:2009 + A1:2012, CAN/CSAC22.2 No. 60601-1-08:2008, DEMKO - EN 60601- 1:2006, EN 60601-1-2:2007, EN 60601-1:2006+A11:2011, CCC - GB9254-2008 + GB4943-2001 + GB17625.1-2003, KC, VCCI, FCC class B, ICES-001 Level B, FDA Class I device, RoHS User Guide
Cable routing strap
Video cables (1 x HDMI, 1 x DisplayPort)
Main cables (UK, European (CEBEC/KEMA) or USA (UL/ CSA; adaptor plug NEMA 5-15P) or Chinese (CCC)) USB 2.0 cable
External power supply (model: BridgePower Corp. BPM060S12F15; Input: 100-240 V AC, 50-60 Hz, 1.5 A; Output: +12V DC (
), 5.0 A)
tion altitude 2000 m
Opera
age altitude 7500 m
Stor
rating pressure 70 kPa - 106 kPa
Ope
orage pressure 50 kPa - 106 kPa
St
K5903049 EONIS 25/06/2015 35
Page 38
7. Important information
MDRC-2122 WP
Product acronym
Screen technology TFT Color LCD IPS
Active screen size (diagonal) 542 mm (21.5”)
Active screen size (H x V) 267,3 mm x 475,2 mm (10.52” x 18.71”)
Aspect ratio (H:V)
Resolution
Pixel pitch 0.2475
Color imaging
Gray imaging
Color support
Viewing angle (H, V) 178°
MDRC-2122 WP
16:9
2MP (1920 x 1080)
Yes
Yes
10 bit
Ambient Light Compensation (ALC) Front sensor Yes
Maximum luminance
DICOM calibrated luminance 180 cd/m²
Contrast ratio
Responsetime(Tr+Tf)
Housing color
Video input signals
USB ports
USB standard
Power requirements (nominal)
Power consumption (nominal) 40 W (<0,5 W in stand-by)
Power save mode Yes
Power management
Dot clock 165 MHz
OSD languages English, French, German, Spanish, Italian, Dutch
Dimensions with stand (W x H xD) Dimensions w/o stand (W x H xD) Dimensions packaged (W x H xD) Net weight with stan
Net weight w/o stand 4.3 kg
Netweightpack stand
Height adjust
Tilt 0° / +20°
Swivel -30° / +30°
Pivot N/A
Mounting
Screen protection Protective, non-reective glass cover
ment range
standard
d
aged with
Yes, preset values in OSD
250 cd/m² typical
1000:1 typical
14 ms
White + Silver
VGA, DisplayPort, H DMI
1 upstream, 2 downstream
2.0
100-240 V
DPMS
507 x 377–457x 166 mm
507 x 306 x 57 mm
610 x 505 x 230 mm
6.7 kg
10.1 kg
80 mm
VESA (75 mm)
36 K5903049 EONIS 25/06/2015
Page 39
7. Important information
Certications CE (MDD 93/42/EEC class I product), CE-2004/108/EC, 2014/30/EU
(Directive 2004/108/EC is repealed with effect from 20 April 2016), IEC 60950-1:2005 + A1:2009 (2ND EDITION), IEC 60601-1 2ND ED:1988 + A1:1991 + A2:1995, IEC 60601-1:2005 + A1:2012, ANSI/AAMI ES 60601-1:2005 + C1:2009 + A1:2012, CAN/CSAC22.2 No. 60601-1-08:2008, DEMKO - EN 60601- 1:2006, EN 60601-1-2:2007, EN 60601-1:2006+A11:2011, CCC - GB9254-2008 + GB4943-2001 + GB17625.1-2003, KC, VCCI, FCC class B, ICES-001 Level B, FDA Class I device, RoHS
Supplied accessories
Optional accessories N/A
QA software QAWeb Private Practice, QAWeb Enterprise
Warranty 3 years
Operating temperature +10°C / +40°C
Storage temperature -20°C / +60°C
Operating humidity 30% - 75% (non-condensing)
Storage humidity 5% - 85% (non-condensing)
User Guide
Cable routing strap
Cleaning cloth
Video cables (1 x HDMI, 1 x DisplayPort)
Main cables (UK, European (CEBEC/KEMA) or USA (UL/ CSA; adaptor plug NEMA 5-15P) or Chinese (CCC)) USB 2.0 cable
External power supply (model: BridgePower Corp. BPM060S12F15; Input: 100-240 V AC, 50-60 Hz, 1.5 A; Output: +12V DC (
), 5.0 A)
Operation altitude
Storage altitude
Operating pressure
Storage pressure
2000 m
7500 m
70kPa-106kPa
50kPa-106kPa
MDRC-2122 TS
Product acronym
Screen technology TFT Color LCD IPS
Active screen size (diagonal) 542 mm (21.5”)
Active screen size (H x V) 267,3 mm x 475,2 mm (10.52” x 18.71”)
Aspect ratio (H:V)
Resolution
Pixel pitch 0.2475
Color imaging
Gray imaging
Color support
Viewing angle (H, V) 178°
Ambient Light Compensation (ALC) Front sensor Yes
Maximum luminance
MDRC-2122 TS
16:9
2MP (1920 x 1080)
Yes
Yes
10 bit
Yes, preset values in OSD
250 cd/m² typical
DICOM calibrated luminance 180 cd/m²
Contrast ratio
K5903049 EONIS 25/06/2015 37
1000:1 typical
Page 40
7. Important information
Responsetime(Tr+Tf)
Housing color
Video input signals
USB ports
USB standard 2.0
Power requirements (nominal)
Power consumption (nominal) 40 W (<0,5 W in stand-by)
Power save mode Yes
Power management
Dot clock 165 MHz
OSD languages English, French, German, Spanish, Italian, Dutch
Dimensions with stand (W x H xD) Dimensions w/o stand (W x H xD) Dimensions packaged (W x H xD) Net weight with stand 6.7 kg
Net weight w/o stand
Net weight packaged with stand
Height adjustment range 80 mm
Tilt
Swivel -30° / +30°
Pivot
Mounting standard
Screen protection Protective, non-reective glass cover
Certications CE (MDD 93/42/EEC class I product), CE-2004/108/EC, 2014/30/EU
Supplied accessories
Optional accessories N/A
QA software QAWeb Private Practice, QAWeb Enterprise
anty
Warr
Operating temperature +10°C / +40°C
Storage temperature -20°C / +60°C
Operating humidity 30% - 75% (non-condensing)
14 ms
Black + Silver
VGA, DisplayPort, H DMI
1 upstream, 2 downstream
100-240 V
DPMS
507 x 377-457x 166 mm
507 x 306 x 57 mm
610 x 505 x 230 mm
4.3 kg
10.1 kg
0° / +20°
N/A
VESA (75 mm)
(Directive 2004/108/EC is repealed with effect from 20 April 2016), IEC 60950-1:2005 + A1:2009 (2ND EDITION), IEC 60601-1 2ND ED:1988 + A1:1991 + A2:1995, IEC 60601-1:2005 + A1:2012, ANSI/AAMI ES 60601-1:2005 + C1:2009 + A1:2012, CAN/CSAC22.2 No. 60601-1-08:2008, DEMKO - EN 60601- 1:2006, EN 60601-1-2:2007, EN 60601-1:2006+A11:2011, KC, VCCI, FCC class B, ICES-001 Level B, FDA Class I device, RoHS User Guide
Cable routing strap
Cleaning cloth
Video cables (1 x HDMI, 1 x DisplayPort)
Main cables (UK, European (CEBEC/KEMA) or USA (UL/ CSA; adaptor plug NEMA 5-15P)) USB 2.0 cable
External power supply (model: BridgePower Corp. BPM060S12F15; Input: 100-240 V AC, 50-60 Hz, 1.5 A; Output: +12V DC (
rs
3yea
), 5.0 A)
38 K5903049 EONIS 25/06/2015
Page 41
Storage humidity 5% - 85% (non-condensing)
7. Important information
Operation altitude
Storage altitude
Operating pressure
Storage pressure
2000 m
7500 m
70kPa-106kPa
50kPa-106kPa
K5903049 EONIS 25/06/2015 39
Loading...