Barco DX-100 Quick Start Manual

Page 1
Quick System Setup
Install and Cable LED Wall — Ensure that your FLX
LED wall is properly installed and cabled.
1
Rackmount DX-100 — Ensure that the DX-100 is properly installed in your equipment rack. (Chapter 3, “Rack-Mount Installation”)
2
5
6
P/N 26-0901004-00, Rev 00
Visibly yours
Barco, Inc.
11101 Trade Center Drive Rancho Cordova, CA 95670 • USA
Phone:
Fax:
Technical Support:
Website:
+1 (916) 859-2500 +1 (916) 859-2515 +1 (866) 374-7878 www.barco.com
Power Installation — Connect power to the DX-100 and all peripheral equipment, such as your video sources. (Chapter 3, “Power Installation”)
Connect Inputs — As required, connect inputs to the DX-100's DVI and SD/HD-SDI inputs. (Chapter 3, “Signal Installation”)
7
8
Power On — Turn on power to the DX-100, sources, the LED wall and (if required) Fiberlink.
9
10
3
4
The following list summarizes the overall DX-100 setup procedure. For error-free installation, always
refer to
the listed section in the User’s Guide.
DX-100
Status
Handles
Two recessed handles
enable you to easily
insert or withdraw the
chassis from a rack.
Status LED
The following indications are provided:
On power up, the LED initializes to Orange, and remains Orange while the DX-100 boots. The LED also turns orange during any “reset” mode.
The LED turns Green once the DX-100 can be controlled remotely.
The LED blinks Red (at a 2 second interval) if the DX-100 detects that the FLX controller is drawing too much current.
IMPORTANT
There are no operational controls
on the DX-100. The DX-100 is set
up and operated entirely from
Barco’s Director Toolset.
Connect Output — Connect the DX-100's NNI LED output to the data input of the FLX LED wall. (Chapter 3, “Signal Installation”)
Connect Genlock — Connect a composite sync or black burst signal to the Genlock In connector. (Chapter 3, “Signal Installation”)
Connect Director Toolset — Connect your laptop PC to DX-100 via Ethernet. Ensure that Director Toolset is properly installed on the laptop. (Chapter 3, “Signal Installation”)
Connect Fiberlink — If required, connect the Fiberlink NNI transmitter and receiver. (Appendix C, “Installation”)
System Operation — Use Director Toolset for all DX-100 setup and operations. Refer to the Director
Toolset User’s Guide for instructions.
IMPORTANT
Director Toolset version 2.03 or
higher is required.
Page 2
DX-100 Rear Panel Connections
DX-100 User’s Guide
For complete details on all installation procedures, please refer to the DX-100 User’s Guide.
100-240V
50-60 Hz, 5.0 A
DIAGNOSTICS
ETHERNET
DMX Thru
DMX In
GENLOCK In
IP Reset
DEFAULT IP
192.168.0.10
SUBNET MASK
255.255.255.0
DVI
In
SD/HD-SDI
In
LED OUT
Latches
Six Latches are provided to assist
with module removal and insertion.
Important
Do not adjust the latch positions. They are reserved for authorized
service personnel only.
SD/HD-SDI Input
Connect either one SD-SDI source or one HD-SDI source. Supported
formats include:
525/60 (NTSC) and 625/50 (PAL) per SMPTE 259M
HD 720p per SMPTE 296M HD 1080i per SMPTE 292M
DVI Input
Connect either single or dual-link
DVI. EDID protocol is supported.
Accepted input types include RGB or
YCbCr, progressive or interlaced.
All resolutions are supported to the
following maximum pixel rates:
165MHz (single-link) 240MHz (dual-link)
Director Toolset User’s Guide
For complete details on all setup, configuration and operations procedures, please refer to the Director Toolset User’s Guide.
LED Output
One HDMI-type connector is provided for the NNI
LED Output. Connect to Barco FLX LED modules
only. The output can drive one display from any
portion of a selected source. The output is limited to
a maximum resolution of 1024 x 768.
Genlock Input
Connect composite sync
(standard or tri-level) or
black burst.
DMX Control
Currently not implem ented.
Ethernet
100BaseT connection fo r
Director Toolset
communications.
Diagnostic Port
For factory and technical
support use only.
AC Power
Connect to your facility’s
power source.
IP Reset
Two functions are provided:
Ethernet Reset — Press once to reset Ethernet parameters to their default settings
Factory Reset — Press for five seconds to reboot and initialize all parameters to factory default settings. All saved parameters will be lost.
Loading...