Baracoda BL2604, BLR2604, BC2604 User Manual

The bluetooth name and Bluetooth registered trademarks are owned by Bluetooth SIG, Inc., and are used by Baracoda under license. The Baracoda names and Baracoda trademarks are own by Baracoda. All specifi cation are subject to change without notice - Non contractual pictures © Baracoda - All rights reserved
Baracoda, Inc. (US Offi ce) Baracoda SA (Europe Offi ce: France) 45 Main street - Suite 616 - Brooklyn, NY 11201 30 Avenue de l’Amiral Lemonnier - 78160 Marly-Le-Roi Ph: 718 488 9600 - Fx: 718 488 9601 Ph: +33 1 30 08 89 00 - Fx: +33 1 30 08 89 98
Important notice
Every effort is made to ensure the accuracy of our product information; however, we accept no responsability for errors or omissions including, but not limited to, the implied warranties of merchantability and fi tness for a particular purpose. We shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this material.
Specifi cations or version may be subject to change without notice. The actual specifi cation and version are based on the product delivered.
Introduction
Scanning a series of programming bar code labels can
confi gure the scanner.
The scanner must be properly powered before program-
ming.
Programming Guide
BC/BL/BLR2604 Programming Guide
2604 Programming guide
This document is to be used with Baracoda Barcode Scanners :
BC2604
BL2604
BLR 2604
Important notice:
Every effort is made to ensure the accuracy of our product information; however, we accept no responsibility for errors or omissions including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. We shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this material.
Specifications or version may be subject to change without notice. The actual specification and version are based on the product delivered.
INTRODUCTION
Scanning a series of programming bar code labels can configure the scanner. The scanner must be properly powered before programming. During the programming mode, the scanner will acknowledge a good and valid reading with a short beep. It will give long beeps for either an invalid or bad reading.
PROGRAMMING OPTIONS
Programmable options are divided into 2 groups. The first group includes the options that show the general behaviour of the scanner. The second group sets the decoding parameters for each barcode symbology.
SCANNING INSTRUCTIONS
The Programming Guide barcodes should be scanned with a full charged set of batteries. The BLR2604 scanning distance is 60 cm.
© Baracoda 2004 Page 1/22
BC/BL/BLR2604 Programming Guide
Table of content
1
Default parameters.................................................................................................................................. 3
1.1
Default values of operating parameters .................................................................................................3
1.2
Predefined barcode identifiers ............................................................................................................. 3
1.3
Default values of decoding parameters ................................................................................................. 3
2
Program procedure using barcode menus ..................................................................................................4
3
Set all defaults........................................................................................................................................ 5
4
General configuration .............................................................................................................................. 6
4.1
Scanning mode selection.................................................................................................................... 6
4.2
Good read beeper tone selection......................................................................................................... 6
4.3
Sound duration.................................................................................................................................. 6
5
Symbologies ..........................................................................................................................................7
Reading code selection ...............................................................................................................................7
Code 9 parameters setting........................................................................................................................... 9
IInterleaved 2 of 5 parameters setting ............................................................................................................9
Chinese post code parameters setting..........................................................................................................10
Codabar/Monarch parameters setting...........................................................................................................10
UPC/EAN/JAN parameters setting ...............................................................................................................11
UPC/EAN/JAN parameters settings (Cont’d) .................................................................................................13
Code 128 parameters setting......................................................................................................................13
UCC/EAN128 parameters setting................................................................................................................13
Industry 25 parameters setting.....................................................................................................................14
Msi/Plessy setting......................................................................................................................................14
Italian pharmacy parameters setting..............................................................................................................15
Barcode length setting ...............................................................................................................................15
ISBN/ ISSN conversion ..............................................................................................................................16
6
Data editing ..........................................................................................................................................17
6.1
Prefix and suffix ................................................................................................................................17
6.2
Barcode identifier code selection ........................................................................................................17
6.3
Barcode identifier code setting ...........................................................................................................17
7
Code 39 full ASCII barcode table.............................................................................................................19
1
© Baracoda 2004 Page 2/22
BC/BL/BLR2604 Programming Guide
Default parameters
This table gives the default settings of all the programmable parameters. The default settings will be restored whenever the "Reset" programming label is scanned and the laser scanner is in programming mode.
1.1 Default values of operating parameters
Function Default Values Scanning Mode Selection Trigger mode Header and Trailer None Good Read Beeper Tone Selection 2.3KHz/50 msec (medium) Code Identifier Transmitting Disable
1.2 Predefined barcode identifiers
Function Default Values Code 39 Barcode Identifier Code M ITF 2 of 5 Barcode Identifier Code I Chinese Post Code Identifier Code H UPC-E Barcode Identifier Code E UPC-A Barcode Identifier Code A EAN-13 Barcode Identifier Code F EAN-8 Barcode Identifier Code FF Coda bar Barcode Identifier Code N Code 128 Barcode Identifier Code K Code 93 Barcode Identifier Code L MSI Barcode Identifier Code P Industry 2 of 5 Identifier Code R IATA Identifier Code T
1.3 Default values of decoding parameters
Function Code Default Value
Code 39 Enable
ITF 2 of 5 Enable
Chinese Post Code Disable
UPC/EAN/JAN Enable
Codabar Enable
Reading codes
Selection
Code 39
Interleaved
2 of 5
MSI/PLESSY Disable
Code 128 Enable
Code 93 Enable
ITAT Disable
EAN-128 Disable
Industry 2 of 5 Disable
Italian Pharmacy Disable
ISSN/ ISBN Disable
Codes Standard
Start/stop characters Not transmitting
Check digit Disabled
Length 6-32 digits
Check digit Disable
Code
UPC/EAN/JAN
Coda bar
Code 128 FNC 2 append Disable
MSI
Italian Pharmacy Transmit "A" Character Not transmitting
Industry 2 of 5 Length 6~32 digits
Length 8~32digits Chinese Post
Check digit Transmit
Format All
Addendum Disable
UPC-E=UPC-A Disabled
UPC-A leading digit Transmit
UPC-A check digit Transmit
UPC-E leading digit Transmit
UPC-E check digit Transmit
Type Standard
Start/stop characters A, B, C, D
Length 6~32 digits
Length Variable
Check digit
Double check but
not transmit
© Baracoda 2004 Page 3/22
BC/BL/BLR2604 Programming Guide
S
2 Program procedure using barcode menus
« Start of configuration » Label
SET ALL
DEFAULTS
CONFIGURATION
SET
GENERAL
NO
FINISH
« End of configuration »
YES
Read
Label
END
TART
Read
SET
SYMBOLOGIES
SET DATA
EDITING
© Baracoda 2004 Page 4/22
BC/BL/BLR2604 Programming Guide
3 Set all defaults
Start of Configuration
Default Settings
The reading of the "Default settings” label turns all the parameters back to default settings.
When you intend to turn your scanner back to default parameter, please scans the "Start of configuration" label first, then scan "Default settings" label and finally scan the "End of configuration" label.
End of Configuration
© Baracoda 2004 Page 5/22
BC/BL/BLR2604 Programming Guide
4 General configuration
Start of Configuration
4.1 Scanning mode selection
The scanner becomes inactive as soon as the data is transmitted. It must be triggered to become active again.
In auto scan mode, the scanner is still active after the data is transmitted, but the successive transmission of the same bar code is not allowed when the trigger switch is pressed again.
4.2 Good read beeper tone selection
You can use this option to set frequency and / or duration of the buzzer after successful reading.
Low
Trigger mode
Auto scan mode
Medium
High
4.3 Sound duration
long(120 ms)
Short(20 ms)
Medium(50 ms)
Very short(5 ms)
Disable