W = Cool white
WW = Warm white
R = Red
G = Green
B = Blue
Y = Yellow
145
285
430
570
710
850
990
1130
D = Diffused plastic
Q = Integral 4-pin M12 QD
(mating cordset required)
C
W145D
Q
Construction
S
S = Sealed
WLS27 LED Strip Light
185590
Instruction Manual
Banner's WLS27 LED Strip Lights have sturdy aluminum housings, encased in shatterproof, UV-stabilized, copolyester shells,
making them ideal for harsh indoor and outdoor applications.
Low-profile, space-saving design
•
• Rugged, water-resistant IP69K option
• Available in eight lengths from 145 to 1130 mm
• Daisy chain power to multiple lights
• Optional snap clips for easy installation and repositioning
• Capability to dim lights using the wiring pinout (Hi/Lo/Off)
• Automatic temperature protection built into the unit. Above 50 °C, the light dims to manage heat and protect product
lifetime
Stand-Alone Light or End Light in a Cascade—QDFirst or Middle of a Cascade—QD
These Work Light Strips are available as either stand-alone models, or as cascade models that can be "daisy-chained" together for
a continuous length of lighting, with a minimum of wiring.
Stand-alone models have a male quick disconnect (QD) at one end for power connection and no connections at opposite end. A
stand-alone model may be used as the last in the cascade series.
Cascade models have a male quick disconnect (QD) at one end for power connection, and a female QD at the opposite end for
connecting to other lights in the cascade. A double-ended accessory cordset must be used between each pair of lights in a
cascade.
Use single-ended cordsets between the power source and the QD connection of a stand-alone light or the
Use double-ended cordsets between lights in a cascade.
first light in a cascade.
Models
Original Document
185590 Rev. F
Models
Stand-AloneCascade
WLS27XW145DSQWLS27CW145DSQ145 mm
WLS27XW285DSQWLS27CW285DSQ285 mm
WLS27XW430DSQWLS27CW430DSQ430 mm
WLS27XW570DSQWLS27CW570DSQ570 mm
WLS27XW710DSQWLS27CW710DSQ710 mm
WLS27XW850DSQWLS27CW850DSQ850 mm
25 January 2019
Lighted LengthPower Connector
Integral 4-pin M12/Euro-style quick
disconnect
D
WLS27 LED Strip Light
Models
Stand-AloneCascade
WLS27XW990DSQWLS27CW990DSQ990 mm
WLS27XW1130DSQWLS27CW1130DSQ1130 mm
Lighted LengthPower Connector
Specifications
Supply Voltage
12 to 30 V dc
Use only with suitable Class 2 power supply (UL) or a SELV power supply (CE).
Light Length
145 mm0.33 A0.15 A0.12 A0.4325325180555040
285 mm0.66 A0.30 A0.24 A0.865065036011010080
430 mm1.01 A0.46 A0.36 A1.2975975540165150120
570 mm1.36 A0.61 A0.48 A1.613001300720220200160
710 mm1.75 A0.77 A0.60 A2.016251625900275250200
850 mm2.13 A0.92 A0.73 A2.4195019501080330300240
990 mm2.59 A1.08 A0.85 A2.8227522751260385350280
1130 mm3.04 A1.24 A0.97 A3.2260026001440440400320
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
When connecting cascadable lights in series at 100% intensity, it is
important not to exceed maximum current limitations:
At 50% intensity, double the lengths.
Certifications
12 V dc24 V dc30 V dcACool WhiteWarm WhiteGreenRedYellowBlue
Color Temperature (CCT): 6000–7100K
Lumen output: 650 (± 5%) per foot, typical at 25 °C (77 °F)
Luminous
CRI: 85, typical
Maximum length of light at 12 V dc: 1.4 m (4.6 ft)
Maximum length of light at 24 V dc: 3.0 m (9.8 ft)
Maximum length of light at 30 V dc: 3.1 m (10.2 ft)
Typical CurrentMax. CurrentLumens (Typical at 25 °C)
LED Lifetime
Lumen Maintenance - L
When operating within specifications, output will decrease less than 30%
after 50,000 hours.
efficacy: 90 lumens/Watt typical at 24 V dc at 25 °C (77 °F)
Mounting
Bracket LMBWLS27EC included (2 for lights up to 570 mm or 3 for lights
710 mm and longer)
Connections
Integral 4-pin M12 male quick disconnect (QD) (4-pin connecting cordset
required)
Environmental Rating
Rated IEC IP66, IP67, and IP69K, per DIN 40050
Operating Temperature
–40 °C to +70 °C (–40 °F to +158 °F)
Light output begins to decrease above 50 °C (122 °F) and will be
approximately 65% of max intensity at 60 °C (140 °F) and 30% of max
intensity at 70 °C (158 °F)
Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F)
Vibration and Mechanical Shock
Vibration 10-55 Hz 1.0 mm p-p amplitude per IEC 60068-2-6
Shock 15G 11 ms duration, half sine wave per IEC 60068-2-27
70
Note: Do not spray cable with high-pressure
sprayer, or cable damage will result.
Performance
For models with heavy diffused housing, multiply lumen values by 0.8.
• Stainless steel mounting brackets
with rubber grips
• M5 stainless steel hardware included
• Clearance for M5 or #10 hardware
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not
cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the
product is
identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will
void the product warranties. All
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:
www.bannerengineering.com
For patent information, see
specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at