Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies.
For complete technical information about this product, including dimensions, accessories, and specifications, see
www.bannerengineering.com and search161999.
Overview
1Output LED
2LO/DO Switch
3RUN/PRG/ADJ Mode Switch
4Lever Action Fiber Clamp
5Red Signal Level
6Green Threshold
7+/SET/- Rocker Button
Figure 1. DF-G1 Model Features
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead toserious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either anenergized or de-energized sensor output condition.
http://
Models
ModelOutputsConnector
DF-G1-NS-2MSingle NPN
DF-G1-PS-2MSingle PNP
DF-G1-KS-2MDual outputs, 1 push-pull IO-Link and 1
DF-G1-NS-Q5Single NPN
DF-G1-PS-Q5Single PNP
DF-G1-KS-Q5Dual outputs, 1 push-pull IO-Link and 1
DF-G1-NS-Q7Single NPN
DF-G1-PS-Q7Single PNP
DF-G1-KS-Q7
1
Connector options:
•A model with a QD connector requires a mating cordset .
•For 9 m cable, change the suffix 2M to 9Min the 2 m model number (example, DF-G1-NS-9M).
•For 150 mm (6 in) PVC pigtail, M8 Pico QD connector, 4-pin change the suffix 2M to Q3 in the 2 m model number (example, DF-G1-NS-Q3).
PNP (complementary outputs)
PNP (complementary outputs)
Dual outputs, 1 push-pull IO-Link and 1PNP (complementary outputs)
2 m (6.5 ft) cable, 4-wire
150 mm (6 in) PVC pigtail, M12 Euro QD connector,4-pin
Integral M8 Pico QD connector, 4-pin
1
Original Document161275 Rev. D
9 September 2015
Fiber EmitterPort
Fiber Receiver
Fiber Clamp
Port
Move forwardto releasethefibers
DF-G1 Expert™
Installation Instructions
Mounting Instructions
Mount on a DIN Rail
1.Hook the DIN rail clip on the bottom of the DF-G1over the edge of the DIN rail (1).
Push the DF-G1 up on the DIN rail (1).
2.
3.Pivot the DF-G1 onto the DIN rail, pressing until itsnaps into place (2).
Mount to the Accessory Bracket
1.Position the DF-G1 in the SA-DIN-BRACKET.
2.Insert the supplied M3 screws.
3.Tighten the screws.
Dual Display Fiber Amplifier
Remove from a DIN rail
1.Push the DF-G1 up on the DIN rail (1).
2.Pivot the DF-G1 away from the DIN rail and removeit (2).
Installing the Fibers
Follow these steps to install glass or plastic fibers.
Open the dust cover.
1.
2.Move the fiber clamp forward to unlock it.
3.Insert the fiber(s) into the fiber port(s) until theystop.
4.Move the fiber clamp backward to lock the fiber(s).
5.Close the dust cover.
Fiber Adapters
NOTE: If a thin fiber with less than 2.2 mm outer diameter is used, install the fiber adapter provided
with the fiber assembly to ensure a reliable fit in the fiber holder. Banner includes the adapters with allfiber assemblies.
2www.bannerengineering.com - Tel: +1-763-544-3164P/N 161275 Rev. D
TO
FIBERS
TO
SENSOR
TRANSMITTER
RECEIVER
Single-core fiber
Multi-core fiber
Remote Programming (N.O.)
10-30V dc
Load
Load
10–30 V dc
Remote Programming (N.O.)
(C/Q)
(Q)
PUSH-PULL
18-30V dc
Load
Load
DF-G1 Expert™Dual Display Fiber Amplifier
Fiber Outer Diameter (mm)Adapter Color
Ø 1.0Black
Ø 1.3Red
Ø 2.2No adapter needed
When connecting coaxial-type fiber assemblies to the amplifier, install the single-core fiber to the Transmitter port, and themulti-core fiber to the Receiver port. This will result in the most reliable detection.
Wiring Diagrams
NPN Models
NOTE: Open lead wires must be connected to a terminal block.
Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJmode switch, LO/DO switch, +/SET/- rocker button, dual red/green digital displays, and output LED.
RUN/PRG/ADJ Mode Switch
The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. RUNmode allows the sensor to operate normally and prevents unintentional programming changes via the+/SET/- rocker button. PRG mode allows the sensor to be programmed through the display-drivenprogramming menu (see Program Mode below). ADJ mode allows the user to perform ExpertTEACH/SET methods and Manual Adjust (see Adjust Mode below).
LO/DO Switch
The LO/DO switch selects Light Operate or Dark Operate mode. In Light Operate mode, the output isON when the sensing condition is above the threshold. (For Window SET, the output is ON when thesensing condition is inside the window.) In Dark Operate mode, the output is ON when the sensingcondition is below the threshold. (For Window SET, the output is ON when the sensing condition isoutside the window.)
+/SET/- Rocker Button
The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/right. The SET position is engaged by clicking down the button while the rocker is in the middle position.All three button positions are used during PRG mode to navigate the display-driven programming menu.During ADJ mode, SET is used to perform TEACH/SET methodsthreshold(s). The rocker button is disabled during RUN mode, except when using Window SET, see
Window SET on page 7.
Red/Green Digital Displays
During RUN and ADJ modes, the Red display shows the signal level, and the Green display shows thethreshold. During PRG mode, both displays are used to navigate the display-driven programming menu.
and +/- are used to manually adjust the
Output LED
The output LED provides a visible indication when the output is activated.
Operating Instructions
Remote Input/IO-Link
For more information about how to perform TEACH/SET methods, to program the sensor remotely, or to interface with thesensor via IO-Link, see the DF-G1 Manual (P/N 161999).
Run Mode
Run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/SET/- rockerbutton is disabled during RUN mode, except when using Window SET, see Window SETon page 7.
4www.bannerengineering.com - Tel: +1-763-544-3164P/N 161275 Rev. D
2PttcH
tcHSEL
Lt SEt
dr SEt
CALSEt
wind SEt
dYn tcH
diSP 1234
diSPrEAd
Auto GAin
GAinSEL
1234 Gn 1
1234 Gn 2
no
FctYdEF
yES
rESPSPd
500 uS
2000 uS
5000 uS
200 uS
OFStPct
10 Pct
min OFSt
Autothr
On
999 Pct
oFF
OFFdLY
0 ms
9999 ms
(+)or (-)
to set value
(+)or (-)
to set value
OFF1Sho
0 ms
9999 ms
(+)or(-)
to set value
OndLY
0 ms
9999 ms
(+)or (-)
to set value
On1Sho
0 ms
9999 ms
(+)or (-)
to set value
diSP 123P
Eco 1234
Eco 123P
diSP 1234
diSP 123P
Eco 1234
Eco 123P
(display flips 180˚)
1234 Gn 8
Fixed Gain Set
To scroll through menu lists: Press “+” or “-”T
o enter a choice list or to select and save: Click SET
To exit a choice list without saving: Pressand hold SET for 2 seconds
Click SET
to enter choice list
Press and hold SET to exit
choice list without saving
DISPLAY
LOOP
Return to Menu List
PROGRAM MODE
Mode Switch
to“PRG”
Click SET
to enter choice list
DISPLAY
LOOP
Click SET
to enter choice list
Click SET
to enter choice list
DISPLAY
LOOP
Click SET
to enter choice list
Click SET
to enter choice list
Click SET
to enter choice list
Click SET
to enter choice list
Click SET
to enter choice list
DISPLAY
LOOP
Click SET
to enter choice list
DISPLAY
LOOP
Click SET
to enter choice list
DISPLAY
LOOP
+
-
SET
rocker button
Click SET to select and save a choice in any list
Menu
List
on displayrepresents a “w”on displayrepresents a “m”
Sliding the RUN/PRG/ADJ mode switch to the ADJ position allows the user to perform Expert TEACH/SET methods andManual Adjustment of the threshold(s).
TEACH Procedures
The instruction manual has detailed instructions for these TEACH modes:
•Two-Point TEACH
•Dynamic TEACH
•Window SET
•Light SET
•Dark SET
•Calibration SET
Two-Point TEACH
•Establishes a single switching threshold
•Threshold can be adjusted by using the "+" and "-" rocker button (Manual Adjust)
Two-Point TEACH is used when two conditions can be presented statically to the sensor. The sensor locates a singlesensing threshold (the switch point) midway between the two taught conditions, with the Output ON condition on one side,and the Output OFF condition on the other.
The Output ON and OFF conditions can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch.
Dynamic TEACH
Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actualsensing conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at theoptimum level.
6www.bannerengineering.com - Tel: +1-763-544-3164P/N 161275 Rev. D
Figure 2. Two-Point TEACH (Light Operate shown)
•Teaches on-the-fly
•Establishes a single switching threshold
•Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
Figure 3. Dynamic TEACH (Light Operate shown)
Sensor positions window thresholds
aprogrammable%offset from the
presented condition
Darkest
(no signal)
Most Light(saturated
signal)
ConditionPresented
Sensing window
center adjusted by
Manual Adjust
Output OFFOutput OFFOutput ON
Threshold position
adjusted by
ManualAdjust
Sensor positionsthreshold a programmable% offset below the presented condition
Darkest
(no
signal)
Most Light(saturated
signal)
Output OFFOutput ON
ConditionPresented
DF-G1 Expert™ Dual Display Fiber Amplifier
The output ON and OFF conditions can be reversed using the LO/DO switch.
Window SET
•Sets window thresholds that extend a programmable % offset above and below the presented condition
•All other conditions (lighter or darker) cause the output to change state
•Sensing window center can be adjusted using "+" and "-" rocker button (Manual Adjust)
•Recommended for applications where a product may not always appear in the same place, or when other signalsmay appear
•See Program Mode in the user's manual for programming the Offset Percent setting (to increase/decrease thewindow size)
A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above andbelow the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition insidethe window, and the Output OFF conditions outside the window.
Figure 4. Window SET (Light Operate shown)
Output ON and OFF conditions can be reversed using the LO/DO switch.
Light SET
•Sets a threshold a programmable % offset below the presented condition
•Changes output state on any condition darker than the threshold condition
•Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
•Recommended for applications where only one condition is known, for example a stable light background withvarying darker targets
•See
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below thepresented condition. When a condition darker than the threshold is sensed, the output either turns ON or OFF, dependingon the LO/DO setting.
Program Mode on page 5 for programming the Offset Percent setting
•Sets a threshold a programmable % offset above the presented condition
•Any condition lighter than the threshold condition causes the output to change state
•Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
Sensor positions
threshold a programmable
% offset above the presented condition
Threshold position
adjusted by
ManualAdjust
Darkest
(no signal)
Most Light(saturated
signal)
Output OFFOutput ON
Condition Presented
Sensor positions
threshold exactly at
the presented condition
Threshold position
adjusted by
ManualAdjust
Darkest
(no signal)
Most Light(saturated
signal)
Output OFFOutput ON
Condition
Presented
DF-G1 Expert™Dual Display Fiber Amplifier
•Recommended for applications where only one condition is known, for example a stable dark background withvarying lighter targets
•See
Program Mode on page 5 for programming the Offset Percent setting
NOTE: Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal (0counts).
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset above thepresented condition. When a condition lighter than the threshold is sensed, the output either turns ON or OFF, dependingon the LO/DO setting.
Figure 6. Dark SET (Light Operate shown)
Calibration SET
•Sets a threshold exactly at the presented condition
•Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When acondition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting.
Figure 7. Calibration SET (Light Operate shown)
Troubleshooting
Manual Adjustments Disabled
Manual adjustments are disabled when Auto Thresholds are ON. If a manual adjustment is attempted while Auto
Thresholds are ON, the Green display will flash
.
Percent Minimum Difference after TEACH
The Two-Point and Dynamic TEACH methods will flash a % minimum difference on the displays after a PASS or FAIL.
0 to 99%FAILThe difference of the taught conditions does not meet the required minimum
100 to 300%PASSThe difference of the taught conditions just meets/exceeds the required minimum,
8www.bannerengineering.com - Tel: +1-763-544-3164P/N 161275 Rev. D
ValuePASS/FAILDescription
minor sensing variables may affect sensing reliability
DF-G1 Expert™ Dual Display Fiber Amplifier
ValuePASS/FAILDescription
300 to 600%PASSThe difference of the taught conditions sufficiently exceeds the required minimum,
minor sensing variables will not affect sensing reliability
600% +PASSThe difference of the taught conditions greatly exceeds the required minimum, very
stable operation
Percent Offset after SET
The Window, Dark, and Light SET methods will flash a % offset on the displays after a PASS or FAIL.
SET Result% Offset Meaning
PASS (with % Offset)Displays the % offset used for the SET method
FAIL (with % Offset)Displays the minimum required % offset necessary to PASS the SET method
FAIL (without % Offset)Presented condition cannot be used for the SET method
Threshold Alert or Threshold Error
Severe contamination/changes in the taught condition can prevent the Auto Thresholds algorithm from optimizing thethreshold(s).
StateDisplayDescriptionCorrective Action
Threshold AlertAlternates
and
The threshold(s) cannot beoptimized, but the sensor's outputwill still continue to function
Cleaning/correcting the sensingenvironment and/or a re-teach of thesensor is highly recommended
Threshold Error
The threshold(s) cannot beoptimized, and the sensor's outputwill stop functioning
Cleaning/correcting the sensingenvironment and/or a re-teach of thesensor is required
NPN/PNP models:10 to 30 V dc Class 2 (10% maximum ripple)IO-Link models:18 to 30 V dc (10% maximum ripple)
Power and Current Consumption (exclusive of load)
Standard display mode: 960 mW, Current consumption < 40 mA at
24 V dcECO display mode: 720 mW, Current consumption < 30 mA at 24 Vdc
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Delay at Power-Up
500 milliseconds maximum; outputs do not conduct during this time
Output Configuration
NPN/PNP models:1 current sinking (NPN) or 1 current sourcing
(PNP) output, depending on model
IO-Link models:1 push-pull and 1 PNP (complementary outputs)
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordancewith local and national electrical codes andregulations.
Overcurrent protection is required to be provided by end productapplication per the supplied table.Overcurrent protection may be provided with external fusing or viaCurrent Limiting, Class 2 Power Supply.Supply wiring leads < 24 AWG shall not be spliced.For additional product support, go to
www.bannerengineering.com
Supply WiringRequired Overcurrent Protection
205.0 Amps
223.0 Amps
242.0 Amps
261.0 Amps
280.8 Amps
300.5 Amps
http://
.
Output Rating
100 mA maximum load (derate 1 mA per °C above 30 °C)
OFF-state leakage current:NPN/PNP models: < 5 μA at 30 V dc;IO-Link models: < 50 μA at 30 V dcON-state saturation voltage:NPN:< 1.5 V; PNP/IO-Link: < 2 V
Output Protection
Protected against output short-circuit, continuous overload, transientovervoltages, and false pulse on power-up
Output Response Time
High Speed: 200 µs; Standard: 500 µs; Long Range: 2 ms; Extra LongRange: 5 ms
Repeatability
High Speed: 66 µs, Standard/Long Range/Extra Long Range: 100 µs
Construction
Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clearpolycarbonate cover
Connections
PVC-jacketed 2 m or 9 m (6.5 ft. or 30 ft.) 4-wire integral cable; orintegral 4-pin M8/Pico-style quick disconnect; or 150 mm (6 in.) cablewith a 4-pin M12/Euro-style quick disconnect; or 150 mm (6 in.) cablewith a 4-pin M8/Pico-style quick disconnect.
Environmental Rating
IEC IP50, NEMA 1
Operating Conditions
Temperature: −10 °C to +55 °C (+14 °F to +131 °F)Storage Temperature:−20 °C to +85 °C (−4 °F to +185 °F)Humidity: 90% at +60 °C maximum relative humidity (non-
condensing)
IO-Link Interface
Supports Smart Sensor Profile:YesBaud Rate:38,400 bps (COM2)Process Data Width: 16 bitsIODD files: Provide all programming options of top panel interface,
plus additional functionality, see the DF-G1 Manual (P/N 161999)
Certifications
Powered by TCPDF (www.tcpdf.org)Powered by TCPDF (www.tcpdf.org)
Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year followingthe date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacturewhich, at the time it is returned to the factory, is found to have been defective during the warranty period. This warrantydoes not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS ORIMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR APARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING ORTRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NOEVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FORANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL ORSPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THEPRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY,NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming anyobligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.
www.bannerengineering.com - Tel: +1-763-544-3164
Loading...