Baldor all products General Product Line Information

Information
General
General Information
Abbreviations: The Basic Baldor catalog number consists of a letter(s) prefix and several non-significant proceeding numbers. A suffix letter(s) and/or
Catalog Number Prefix:
Single Phase
AEM Automotive Motor (GM7EHQ)
Motors
AF Aeration Fan Motor AM Automotive (Motor GM7EQ) ANF Auger Flange Motor AO Air-Over Motor AP Subfractional HP, PM Motor AS Arbor Saw Motor
Industrial Motors
General Purpose
B Brake Motor BC DC Motor Speed Control BK Single Phase Gearmotor Kit BLW Blower Kit BMC Brushless DC Motor Control BSM Brushless Servo Motors BTG Tachometer Generator BU Bushing Kit
Premium Efficient
Super-E® Motors
C NEMA C-Face with Base CBL Cable Assembly CD Wound Field DC Motor NEMA C-Face with Base CDP PM SCR Drive Motor CDPT PM SCR Drive Motor with Integral Tachometer CDPWD Washdown PM SCR Drive Motor, NEMA C-Face
Severe Duty
CDPSWD PM Paint Free Washdown SCR Drive Motor
Motors
C-Face with base CDPX PM Explosion Proof SCR Drive Motor ­ C-Face with base CDX Wound Field Explosion Proof DC Motor, NEMA C-Face CESWDM Paint Free Super-E Washdown - C-Face with base
Washdown Duty
CF Condenser Fan Motor CHC Direct Drive Fan Motor with Resilient Base
Motors
CP Chemical Processing, Corrosion Protected Motor CR Crusher Motor CSC Checkout Stand Motor CSM Baldor SmartMotor CSSEWDM All Stainless Super-E Washdown-C-Face with base CSSWDM All Stainless Washdown - C-Face with base
Explosion Proof
CSWDM Paint Free Washdown - C-Face with base CWAM Dirty Duty Washdown - C-Face with base
Motors
CWDSM Baldor Washdown SmartMotor D DC Shunt or Compound Motor or Definite Purpose Soft Start Control DE Vacuum Pump Motor DG Gate Operator Motor DMG Lifting Magnet Generator DOC Door Operator Motor
Pump Motors Commercial
DR Double Reduction E Super-E Premium Efficiency E3H Super-E Premium Efficiency HVAC Duty with Connection Box located on top of Motor ECP Super-E Premium Efficiency, Chemical Processing Hostile Environment Motor EN Encoder Kit FM F-2 Mount Motor
Motors
FCD Drip Cover Kit FD Farm Duty Motor FFC Fan Cover/Conduit Box Kit FL Flange Kit G Subfractional HP Gear Motor GC Permanent Split Capacitor and Split Phase GCP Permanent Split Capacitor and Split
HVAC Motors
Phase Parallel Shaft Gearmotor GD Centrifugal Fan Motor GF 900 Series Reducers GP Subfractional HP PM Motor GPP PM Parallel Shaft Gear Motor
GSF Universal Series Right Angle Gear Reducers GS Grain Stirring Motor H Definite Purpose HVAC Motors H3 HVAC Duty with Connection Box located on top of Motor HP Hydraulic Pump Motor ID Inverter Control IDM Inverter Drive Motor-TEBC IDNM Inverter Drive Motor-TENV IDWNM Washdown Inverter Motors-TENV IDXM Explosion proof Inverter Drive Motors-TEFC IM Irrigation Drive Motor IR Instant Reversing Single Phase Farm Motor J NEMA 56J Stainless Steel Threaded Shaft with Dripcover JM NEMA JM Pump shaft & Face with Base JP NEMA JP Pump shaft & Face with Base JSL Square Flange Pump Motors with threaded shaft. K Model 34 Diameter Motor with 56 C-Face, less Base KN Model 34 Diameter TENV Motor with 56 C-Face, less Base L Single Phase LRA Line Reactor M Three Phase M Multipurpose Soft Start Control MM Metric Dimension Motor with Base MPM Three Phase Metering Pump MVM Metric Dimension Motor, Flange Mount less Base N Totally Enclosed Non ventilated OF Design D, High Slip Motor (Oil Field) P Pressure Washer Motor P15 Pre-Engineered Control Panel PSC Permanent Split Capacitor R Repulsion-Start, Induction-Run Motor RBT Roller Bearing Conversion Kit RES Resolver Feedback Kit RG Regeneration Resistor Assembly RH Definite Purpose HVAC Motors RL&RM Resilient Base(Cradle Mount) RT Dynamic Braking Resistor Assembly S Single Phase Soft Start SD Series 23H Servo Control SS All Stainless Washdown Duty SWD Stainless Washdown Duty T Torque Control TA Torque Arm TM Definite Purpose HVAC Motors with Terminal Panel Endplate TK Tachometer Mounting Kit UC Universal Crop Dryer Motor V NEMA C-Face less Base VH Vertical Pump Motor, Normal Thrust VJM NEMA JM Pump Shaft and Face less Base VLCP Vertical Pump Motor, Medium Thrust VP PM SCR Drive Motor with Metric Face or Flange VPCP Vertical Pump Motor, High Thrust WC West Coast Fit NEMA TCZ WD Washdown Duty WW Woodworking Motor ZD Vector Control ZDM Vector Drive Motor-TEBC ZDNM Vector Drive Motor-TENV ZDWNM Washdown Vector Motors-TENV
Catalog Number Suffix:
-2 120/240V Field
-277 277 Volt Winding
-4 460 Volt Winding
-5 575 Volt Winding
-8 200 Volt Winding
-9 NEMA Design C High Torque Winding
-12 12 Leads /35 Full 140 Frame Band Diameter /36 Full 180 Frame Band Diameter
-50 Wound for 50 Hertz Service
-2341 2300/4160 Volt Winding A Automatic Thermal Overload BV Blower Vented
-C Listing includes Class I, Group C
-CL Open Chassis Enclosure, Line Regenerative
-CO Open Chassis Enclosure, no internal braking E Electric Switch
-E NEMA 1 Enclosure, built in Dynamic Braking
-EL NEMA 1 Enclosure, Line Regenerative
-EO NEMA 1 Enclosure, no internal braking
-ER NEMA 1 Enclosure, built in Dynamic Braking Transistor
-I Explosion-Proof, 1.15 Service Factor M Manual Thermal Overload
-MO Protected Chassis Enclosure, no internal braking P Wound Field DC Motor NEMA “AT” Frame
-P Partial AC Motor Excludes R- Roller Bearing T NEMA "T" Frame Dimension TP Feather Picker Motor TR NEMA “T” Frame-Roller Bearing TS NEMA "TS" Frame Short Shaft Pulley Endplate
-V12 12 Volt DC
-V24 24 Volt DC
-W NEMA 4 Enclosure
-WR Washdown Rating
Gear Reducer Suffix: 900 Series
A 56C Motor Flange B 140TC Motor Flange C 180TC Motor Flange G Left Hand Output Shaft H Double End Output Shaft J Right Hand Output Shaft
Gear Reducer Suffix: Universal Series
A 56C or Right Hand Output Shaft B 140TC C 180TC
Grinder Catalog Number Suffix:
D Deluxe E Exhaust Guards W Wide Design
Other Abbreviations:
C Permanent Split Capacitor L Capacitor-Start, Induction-Run Motor LC Capacitor-Start, Capacitor-Run Motor S Split Phase X Explosion-Proof
6
CATALOG NOTES:
1 Class F Insulated Motor with 1.15 Service Factor or higher that
operates within Class “B” temperature limits at rated horsepower. 2 1.00 Service Factor. 3 Capacitor start, induction run. 4 Wye-start, delta-run. 5 Belted duty only, roller bearing. 6 F-2 Mounting 7 Companion voltages not available. 8 Class “H” Insulated. 9 Motors are not NAFTA qualifi ed. 10 These motors meet the hardware requirements of IEEE 45/ABS
and are not provided with Marine Plan Documentation. 13 Furnished without conduit box. Order kit P/N K56G3230. 14 Type CH (Capacitor Start - Capacitor Run). 15 Motors rated 208-230/460 are operable to minimum 200 volts. 17 Capable of 100% thrust in either direction. 18 Capable of 100% thrust stated in downward direction (out of motor)
and 40% upward thrust (into motor). 19 60/50 Hertz motor. 60 Hertz data shown, contact your local Baldor
offi ce for 50 Hertz data. 20 Class F Insulation. 21 Double bolt. 22 Base used for NEMA & above NEMA frames, 445T. 23 Two piece slide rails. 24 DOL or Part Winding Start. 25 DOL or Wye Start, Delta Run 26 Non-standard “BA” due to drive end bearing cooling fan.
Please refer to layout drawing. 27 Motors have ball bearing suitable for coupled loads. If load is belted,
a roller bearing may be required, contact your local Baldor offi ce. 28 Usable at 200 volts. 29 V-dimension is 2.5”. 30 Usable at 208 volts. 31 Suitable for 230/460, 60 Hz and 190-220/380-440 volts, 50 Hz. 32 Stearns brake. 33 Voltage at 60Hz. 34 Dodge D series brake. 35 Design A, also meets Design E inrush limits. 36 Can mount as 56, 143T & 145T frames with NEMA 56 shaft
dimensions. 37 Can mount as 56, 143T & 145T frames with NEMA 143T-145T
shaft dimensions. 38 Can mount as NEMA 56, 143T and 145T frames with NEMA 56
frame shaft dimensions. 39 Class F Rise 40 Brake motors may be mounted for vertical mounting with brake
below motor. 41 Brake motors may be mounted for vertical mounting with brake
above or below motor. 42 DODGE Short Series Brake. 43 Cannot be mounted vertically. 44 Shown as WPI enclosure. 45 Horizontal mount, no C-Face. May be converted to C-Face in Mod Express or built as custom motors. 46 Includes 1024 ppr encoder. 47 BA dimension does not meet NEMA standards. 48 Includes phase insulation. Suitable for inverter duty. 49 Includes vertical lifting provision. 50 Cast Iron 140 Frame. 51 BISSC Certifi ed. 52 IP55 Enclosure.
53 Voltage at 50Hz. 54 Motors have NEMA standard BA dimensions. 55 Constant velocity fan: 115 volts, single phase. 57 Can mount as NEMA 145T frame with 145T frame shaft dimensions. 58 Can mount as NEMA 56, 143T and 145T frames with
NEMA 143T-145T frame shaft dimensions. 60 Totally-Enclosed, Non-Ventilated, Continuous Duty. 61 Copper bar rotor standard. 63 Foot also drilled for 447T frame mounting. 64 Motors include 100 ohm platinum winding RTDs and space heaters. 65 Capacitor start, capacitor run (two value capacitor). 66 Resilient mount single phase motors with moderate starting torque
for fan applications. 67 Voltage at 50//60 Hz. 68 3 lead. 69 6 lead suitable for part winding start on 200 volts. 70 Constant velocity fan: 230/460 volts, three phase. 71 Nominal effi ciency is based at the 1800 RPM (High RPM) and low
speed effi ciency is available just not published. 72 Orders shipped from a Reliance facility in 3 working days.
Motor is returnable for a restocking charge of $100 plus 10% of the
net motor price. 73 SCR Motors with a 3:1 constant torque speed range. 74 V-dimension is 3”. 75 Availability limited to current stock. 76 Flexible waterproof cover protects thermal overload reset button. 77 Inverter Duty. 78 Furnished without conduit box. Order Kit BKP2400. 80 Design criteria similar to motors in Commercial Duty Motors section. 81 5.5 inch frame – Aluminum end shield standard enclosure 82 6.3 inch frame – Aluminum end shield standard enclosure 83 Not suitable for use on motors which have model number with
“a, b or c” suffi xes 84 Does not meet NEMA BA for C-face footed motors 85 Can only be used on motors 1800 RPM and slower with ball bearings 86 Cannot be operated at full nameplate rating on 50 Hz rectifi ed power
supply 87 Tach adaptable with Thermostat 88 Sleeve bearings - coupled loads only. 89 Cooling fan on each end. 90 Includes thermostat. 91 Blower on drive end. 92 Force vent with blower and fi lter. Full nameplate rating on 50 Hz
rectifi ed power, AC supply voltage must be same as 60 Hz supply. 93 Force vent with blower, full nameplate rating on 50 Hz rectifi ed
power. AC supply voltage must be same as 60 Hz supply, thermostats
and tach provisions. 94 Force vent with blower, cannot run full nameplate on 50 Hz rectifi ed
power, thermostats and tach provisions. 95 Force vent with blower on drive end fi lter, thermostats and tach
provisions. 106 Finned aluminum frame construction.
EXPLOSION-PROOF MOTOR SYMBOLS:
Q Class I, Group D only, T2C. W Class I, Group C & D, Class II, Group F & G, T4. E Class I, Group D, Class II Group F & G, T3B T Class I, Group C & D only, T3C Y Class I, Group D only, T2A. U Class I, Group D, Class II, Group F & G, T4. I Class I, Group D, Class II, Group F & G, T3C.
Loading...