GS500Z Configuration Guide GS500Z Expander Board Options
123456789
F6, T30A 480V
J51
J52
A
J25
J32
B
1
C
2
3
J50
TB1
D
4
E
Balboa
BALBOA INSTRUMENTS, INC.
GS500Z
COPYRIGHT 2006
MADE IN U.S.A.
P/N 22015_A
W1
HTR2
Pb
AV
G
N
CIRC. PUMP
J47
G
N
F4, T0.3A 250V
J28
J26
J101 J100
J29
OZONE PUMP 1
W2
HTR1
N
G
J58
J57
J90
J23
K9
N
G
T1
K3K4
K2
123456789
Output Features Quadrant
J50 Audio Visual (always hot - no relay) 3-A
J47 Circ Pump 3-A
J29 Ozone 4-A
J23 2-Speed Pump 1 4-A
J20 Spa Light 8-B
System can be factory configured for either a Duplex Topside Panel,
a Serial Standard Panel, or a Digital Deluxe Panel.
Note: Some panels styles are not available depending on system
configuration. Consult your Balboa product representative for details.
Balboa
Instruments
Incorporated
K6
E.GND
F2
S1
E.GND
K1
SWITCHBANK A
N
G
J17/26
OPT. BLWR/PUMP 2
J46
K8
J72
J1
J2
J43
J10
J60
J6
TST
EXT RLY
F7
F10A 250V
J7
11
J22
AUX F
SEN A
F3A 250V
J20
K5
C9
J1A
J2A
J44
J8
11
VACSEN B
NG
F3
J71
U4
J19
J12
1
1
J11
X-Mount P
Used for mounting any Expander Board
in a plastic enclosure.
Standoffs attach to heater mounting bracket.
NOTE Regarding J12 (Quadrant 9-E):
When J12 on the Main Board is jumpered on
pins 2 & 3, the system is in GS50xZ compatibility
mode.
If J12 on the Main Board is jumpered on pins 1 & 2,
the system is in GS51xZ/GS5xxSZ/GS5xxDZ
compatibility mode.
F1
J13
J18
1
J18
PN 53933
N
W12
G
J6
J3
PN 53311
K2
A
J2
J4
B
X-P CE
Used for a 1-speed Pump output.
• J4 on X-P CE connects directly to Line AC
using J52 or J51 on the main GS500Z PCBA.
C
• J2 on X-P CE connects to J60 on the main board.
• W12 on X-P CE connects directly to Neutral AC
using J57 or J58 on the main GS500Z PCBA.
J6
N
G
K2
F5
F10A 250V
W12
PN 53547
J2
X-B CE
Used for a Blower output ONLY.
• J3 on X-B CE connects directly to Line AC
using J52 or J51 on the main GS500Z PCBA.
• J2 on X-B CE connects to J60 on the main board.
• W12 on X-B CE connects directly to Neutral AC
using J57 or J58 on the main GS500Z PCBA.
D
X-P231 CE
PN 55025
J1
R
E
W1
B
W
G
F30A 480V
P/N 22909 REV B
J6
X-P231 CE
Can replace the X-P CE in cases where branch circuit
protection is needed for high amperage devices that
J7
PN 55025
K2
J6
J7
N
G
N
G
J2
J4
W12
J5
To J17/26
(Blower/P2)
would over-burden power input fuse F6 (1-A) on the
main PCBA.
• J6 on X-P231 CE connects directly to Line AC
using J25 or J32 on the main GS500Z PCBA,
depending on AC Service Configuration.
VS-P2 Adapter Wire
PN 25339
To J5 on X-O3
• J7 on X-P231 CE connects to J60 on the main board.
• W1 on X-P231 CE connects directly to Neutral AC
using J57 or J58 on the main GS500Z PCBA.
PN 53985
W1
X-2SP CE Kit
X-P332 CE
PN 55138
J1
R
B
W
G
F30A 480V
P/N 22909 REV B
J6
J7
Adapter PN 25339 is used in conjuction with
an X-O3 CE to run a 2-speed Pump 2.
No Blower is available when this kit is used.
• J4 on X-03 CE connects directly to Line AC
using J52 or J51 on the main GS500Z PCBA.
• J2 on X-03 CE connects to J60 on the main board.
• W12 on X-03 CE connects directly to Neutral AC
using J57 or J58 on the main GS500Z PCBA.
X-P332 CE
PN 55138
Can replace the X-P CE in cases where branch circuit
• J5 on X-03 CE connects J17/26 connector on
the main GS500Z PCBA using adapter wire VS-P2.
protection is needed for high amperage devices that
would over-burden power input fuse F6 (1-A) on the
main PCBA.
• J6 on X-P332 CE connects directly to Line AC
using J25 or J32 on the main GS500Z PCBA,
depending on AC Service Configuration.
• J7 on X-P332 CE connects to J13 on the main board.
• W1 on X-P332 CE connects directly to Neutral AC
using J57 or J58 on the main GS500Z PCBA.
Document PN 40508_F