GL8000 Mach 3 Configuration Guide GL8000 Expansion Options
123456789
J29
321
F5
J62
J6
J75
J76
N
G
M10
W1
F4
321
J52
J7
J8
J46
321
K1
J50
321
J37
F4, F3A 250V
J84
321
321
J77
EXT I/O
J36
TV2
J69
ADCM
J35
J17
J18
J82
J19
J24
UV
ALARM
TV1
TST
J10
REMOTE
J15
J83
AUX. FSEN. A VACSEN. B
CFG
J9
A
N
G
PN 53914X-Mount M
M12
B
Used for mounting any Expander Board
in a metal enclosure.
Bracket attaches to heater mounting straps
J33 J41 J81 J45
J16J40J34J31
W2
NG
J72J73 J71 J70
J91
J20
C45
MAIN PANELS AUX PANELS
C
230 VAC
Spa Light Configuration
10 VAC
J56
K10 K15
J60
F5, F10A 250V
F5
R
B
W
G
W1
F4
F4, F3A 250V
D
E
F
G
Spa Light Configuration
J56
H
K10 K15
J6
ADCM SPLITTER
PN 54530
J2
© 2006
Balboa
MADE IN U.S.A.
P/N 22039_ A
J60
F5, F10A 250V
J1
TEST
F5
R
B
W
G
W1
F4
F4, F3A 250V
J3
ADCM SPLITTER KIT
Required when using a Menu-driven panel.
Kit includes PCB, stand-offs, and cable.
Note: Software v29 or higher required.
• J2 connects to ADCM IN (J69) on main PCBA.
• J3 connects to Menu Panel or Transceiver.
• J6 connects to tester or F.A.S.T. station.
A
B
C
D
E
Balboa
BALBOA INSTRUMENTS, INC.
GL8000 Mach III
COPYRIGHT 2006
MADE IN U.S.A.
P/N 22960_C
F7
F7, T30A 480V
J39
1 2 3
G
N
J1
N
G
K2
K3
F6, T30A 480V
F2
J23
K4
K11
M5
J5
M16
M15
J79
J94
J27
J96
J95
TB1
1
J14
J3
N
G
M3
F6
F2, T0.5A 250V
J32
K9
M7
G
N
J54
J2 J4
N
G
M4
BARCODE
J53
N
G
M2
M8
J12J11
G
N
J47
2
F
3
J28
J26
M1
J25
M11
F9
4
G
K7
J59
J57
H
J58
HTR2
K6
HTR1
K8
J90
F1
F9, T30A 480V
SWITCHBANK A
123456789
Soldered-In Jumper Configuration
3
21
Locations 1 & 2 determine 10VAC, Locations 2 & 3 determine 230VAC.
Soldered-In Jumper Application Quadrants
J29 + J50 Determine Voltage for J9 (Mist) 8-A, 8-B
J37 + J38 Determine Voltage for J10 (Spa Light) Unused
Light Votage is determined with W1 & W2
J47 + J52 Determine Voltage for J7 (Misc.) 5-E, 7-E
J49 + J46 Determine Voltage for J8 (Fiber Optic) 5-F, 7-F
Balboa
Instruments
Incorporated
J56
J55
K10
K5
321
J49
3
2
1
K13
SWITCHBANK B
K15
F5, F10A 250V
J60
J38
J14
J16
J13
J30
RLY
J74
N
G
N
G
J51
J21
J22
Output Features Quadrant
J1 2-Speed Pump 1 3-A
J2 Output tied to Pump 1 Low 4-A
– OR output tied to Circ Pump (Set with J39)
J3 Circ Pump 3-A
J4 Ozone 5-A
J5 A.V. 2-C
J6 Blower 7-B
J10 Spa Light (10V or 230V) 8-C
J7 Misc (Separate Relay 10V or 230V) 7-E
J8 Fiber Optic (10V or 230V) 7-F
J9 Mister (10V or 230V) 9-A
J11 2-Speed Pump 2 4-C
J12 2-Speed Pump 3 5-C
Red
White
To J11
Green
Black
White
Pump 5 Pump 2
Green
PS-25
PN 25094
Used to split the output from the Pump 2 Connector (J11)
into a single-speed Pump 2 and single-speed Pump 5.
White wire quick connect goes to Main PCB at J59.
PS-34
PN 25093
Used to split the output from the Pump 3 Connector (J12)
into a single-speed Pump 3 and single-speed Pump 4.
R
B
W
G
White wire quick connect goes to Main PCB at J58.
ELS-VALVE
PN 22934
Used to split the output from a single-speed Pump to allow
a Valve Sequencer to be powered by the pump’s output.
J33 J45
W2
N
G
J10
W1
J1
R
B
W
G
T30A 480V
X-P632 CE
X-P632 CE
PN 55026
P/N 22909 REV B
J2
J6
PN 55026
Used for an additional 2-speed Pump output.
R
B
W
G
Relay control J2 plugs into the EXP I/O connector J36 on
the Main PCBA (Quadrant 7-G).
X-P CE
PN 53547
Used add a additional 1-speed Pump output when all
main board pump connections are used.
J33 J45
W2
N
G
J10
X-P231 CE
Can replace the X-P CE in cases where branch circuit protection
is needed for high amperage devices that would over-burden
power input fuse F6 or F7 (3-D) on the main PCBA.
PN 55025
PN 54530
Document PN 40619_H
04-06-2007