Balboa Water Group 300F User Manual

Balboa 300F-Series Operation Guide
For Systems with Software v41 Only.
Initial Start-up
Your spa will enter Priming Mode ( ) when it is energized.
During Priming Mode, press “Jets” button repeatedly and be sure the pump is free of air. Priming Mode lasts less than
5 minutes. Press “Temp” to exit. After Priming Mode, the spa will run in Standard Mode (see Mode section). Some panels may not have a “Temp” button. On these panels the “Set,” “Warm,” or “Cool” buttons are used.
Pump 1 low-speed is responsible for heating and fi ltration and will be referred to simply as the pump.
In multi-button sequences, if the buttons are pressed too quickly in sequence, they may not register.
Cool WarmLightJets
Button shapes and labels may vary.
Temp Control (80°F - 104°F / 26°C - 40°C)
The last measured water temperature is constantly displayed.
The water temperature displayed is current only when the pump has been running for at least 1 minute.
the set temperature, press the button once. To change the set temperature, press the button a second time before the display stops fl ashing. Each press of the button will continue to either raise or lower the set temperature. If the opposite direction is desired, allow the display to revert to the current water temperature. Press the button to display the set temperature, and again to make the temperature change in the desired direction.
On panels with “Warm” and “Cool” buttons, to display the set temperature, press “Warm” or “Cool” once. To change the set
temperature, press a temperature button again before the display stops fl ashing. Each press of “Warm” or “Cool” will adjust the
set temperature. After three seconds, the display will stop fl ashing and begin to
display the current spa temperature.
Jets
Press “Jets” to turn the pump on or off, and to shift between low and high speeds (if equipped). If left running, the pump will turn off after a preset length of time, which on some systems may be as long as 2 hours for low speed. Low speed may run automatically at times, during which it cannot be deactivated from the panel, but high speed may be operated. The ozone generator (if installed) will activate anytime low speed is running.
Light
Press “Light” to operate the spa light. Turns off after 4 hours.
Mode
Depending on system confi guration, mode changing may not be available and will be locked in Standard Mode.
Mode is changed by pressing “Temp,” then “Light”. Standard Mode maintains set temperature. will be displayed
momentarily when you switch into Standard Mode. Economy Mode heats the spa to the set temperature only during
fi lter cycles. will display when water temp is not current, and will alternate with water temp when the pump is running.
Sleep Mode heats the spa to within 20°F/10°C of the set temperature only during fi lter cycles. will display when water temp is not current, and will alternate with water temp when the pump is running.
Preset Filter Cycles
The fi rst preset fi lter cycle begins 6 minutes after the spa is energized. The second preset fi lter cycle begins 12 hours later.
Filter duration is programmable for 1, 2, 3, 4, 5, 6, 7, or 8 hours. The default fi lter time is 1 hour.
To program, press “Temp,” then “Jets.” Press “Temp” to adjust. Press “Jets” to exit programming.
This document covers VS and GS systems 300F using software v41 only with Balboa Panels VL200 through VL406. www.balboa-instruments.com
Diagnostic Messages
Message
Meaning
No message on display. Power has been cut off to the spa.
Temperature unknown.
“Overheat” - The spa has shut down.* One of the sensors has detected 118°F/47.8°C at the heater.
“Overheat” - The spa has shut down.* One of the sensors has detected that the spa water is 110°F/43.5°C.
Spa is shut down.* The sensor that is plugged into the Sensor “A” jack is not working.
Spa is shut down.* The sensor that is plugged into the Sensor “B” jack is not working.
Sensors are out of balance. If alternating with spa temperature, it may just be a temporary condition. If fl ashing by itself, spa is shut down.*
A signifi cant difference between temperature sensors has been detected. This could indicate a fl ow problem.
Action Required
The control panel will be disabled until power returns. Spa settings will be preserved until next power up.
After the pump has been running for 1 minute, the current water temperature will be displayed.
DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool. Once the heater has cooled, reset by pushing any button. If spa does not reset, shut off the power to the spa and call your dealer or service organization.
DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool. At 107°F/41.7°C, the spa should automatically reset. If spa does not reset, shut off the power to the spa and call your dealer or service organization.
If the problem persists, contact your dealer or service organization. (May appear temporarily in an overheat condition.)
If the problem persists, contact your dealer or service organization. (May appear temporarily in an overheat condition.)
If the problem persists, contact your dealer or service organization.
If the water level is normal, make sure all pumps have been primed. If problem persists, contact your dealer or service organization.
Persistent low fl ow problems. (Displays on the fi fth occurrence of Heater is shut down, but other spa functions continue to run normally.
Possible inadequate water, poor fl ow, or air bubbles in detected in the heater. Spa is shut down for 15 minutes.
Inadequate water detected in heater. (Displays on third occurrence of message.) Spa is shut down.*
“Ice” - Potential freeze condition detected.
* - Even when spa is shut down, some equipment will turn on if freeze protection is needed.
message within 24 hours.)
Follow action required for spa will not reset automatically; you may press any button to reset.
If water level is normal, make sure all pumps have been primed. Press any button to reset. This message will reset within 15 minutes. If problem persists, contact your dealer or service organization.
Follow action required for message. Spa will not automatically reset. Press any button to reset manually.
No action required. All equipment will automatically activate regardless of spa status. The equipment stays on 4 minutes after the sensors detect that the spa temperature has risen to 45°F/7.2°C or higher. An optional freeze sensor may be added to protect against extraordinary freeze conditions. Auxiliary freeze sensor protection is advisable is colder climates. See your dealer for details.
message. Heating capability of the
Warning! Shock Hazard! No User Serviceable Parts.
Do not attempt service of this control system. Contact your dealer or service organization for assistance. Follow all owner’s manual power connection instructions. Installation must be performed by a licensed electrician and all grounding connections must be properly installed.
P/N 40887_A 11/08/2007