EL/GL SERIES (Mach 3) CONTROL WITH MLM990S PANEL
The MLM990S panel can be used with the EL8000,
EL5000, EL2000 and EL1000 systems. System software
version 28 or higher is required for this panel. This user
guide lists all features that are available. The features
shown on your panel menus may vary depending on
the system and equipment used.
The pump responsible for heating and filtration
(pump 1 low on non-circ systems, or the circ pump on
circ systems) will be referred to simply as the pump.
Table of Contents
A. Overview of a Start Up and Screen Displays . . . 2
Initial Start-up.............2
Use the Arrow and Enter Keys to Navigate . . 2
Home Display Screen (or “Home”) . . . . . 2
Setting the Time . . . . . . . . . . . . 2
Setting the Spa Temperature Using Fast Keys. . 2
Front Panel Buttons and Lights.......2
Jets 1 Button . . . . . . . . . . . . . . . . 2
Jets 2 Button . . . . . . . . . . . . . . . . 2
Blower Button ...............2
Light Button ................3
B. Fast Keys Give Quick Access to System Set-up . . 3
C. Spa Functions Turn Equipment On or Off . . . . 3
Jet Control . . . . . . . . . . . . . . 3
Jets 2-6 . . . . . . . . . . . . . . . . . . . 3
Lighting . . . . . . . . . . . . . . . 3
Blower Option ............3
Mister Control.............3
Options . . . . . . . . . . . . . . . 4
D. Set Menu Presets Your Equipment .......4
The “Spa Settings” Submenu .......4
Set Temp . . . . . . . . . . . . . . 4
Filter Cycles, to Program . . . . . . . . . 4
Fast Keys, to Program . . . . . . . . . . 4
Time-outs refer to a preset length of time that a
function is programmed to operate before shutting off
automatically. Certain conditions (filters or freeze) can
cause a function to operate longer, while faults can
cause a function to operate for a shorter length of time.
The system keeps track of time-outs regardless of other
conditions occurring.
Mode, Change Heat Mode . . . . . . . . 4
Time of Day . . . . . . . . . . . . . 4
User Settings . . . . . . . . . . . . . 5
Panel Settings .............5
Diagnostics..............5
Versions/Version Information . . . . . . . 5
E. Additional Options . . . . . . . . . . . . . . . 5
Freeze Protection ...........5
Clean-up Cycle . . . . . . . . . . . . 5
Circ Pump . . . . . . . . . . . . . . 5
Ozone . . . . . . . . . . . . . . . 5
Diagnostic Messages . . . . . . . . . . . . . . . . 6
Periodic Reminder Messages ...........8
GFCI Protection . . . . . . . . . . . . . . . . . . 8
Optional Auxiliary Panels .............9
Jets 4 (optional on some systems) . . . . . 9
Jets 5, Jets 6 (optional on some systems). . . 9
Mister (optional) . . . . . . . . . . . 9
TV Lift (optional) . . . . . . . . . . . 9
Basic Installation & Configuration for Mach 3 . . . . 10
Guidelines for Mach 3 EL-Series Spa Controllers. . . 10
CSA Compliance/Conformité . . . . . . . . . . . . 10
Warning! GFCI Protection. . . . . . . . . . . . . . 10
Front Panel Screen and LEDs
Jet Number 1
Jet Number 2
Blower
Lights
J1
J2
BL
LT
LEDs are lit when functions are on
102º F
Diagnostic and Reminder messages appear in place
of Any Diagnostic Messages
HT
FC
OZ
Heater
Filter Cycle
Ozone
To exit a menu,
Arrow Left
Page 1
A. Overview of a Start Up and Screen Displays
Setting the Spa Temperature Using Fast Keys
Initial Start-up
When your spa is first actuated, it will go into Priming
mode and then a quick configuration. Please see the
M-7 Installation Instruction Manual for complete
instructions on Power-up and Pump Priming.
The Priming mode will last for up to 4 minutes and
then the spa will begin to heat and maintain the water
temperature in the Standard mode. You will be given
options as to whether you want the priming modes
to continue or not. Follow the on-screen instructions.
Highlight your choice and press Enter (
alone, the system will resume after 4 minutes. The
Home display screen will appear after completion.
). If left
Use the Arrow and Enter Keys to Navigate
Use the buttons on the front panel to move within
the menu: Up
Enter (
To exit menus and go back to Home, press the left
arrow key until the Home display screen appears.
) chooses your menu selection.
, Left , Right , or Down .
Home Display Screen (or “Home”)
The three basic function keys on the main display screen
are “Fast Keys”, “Spa”, and “Set”. The spa temperature
will appear after the system has ran its diagnostic tests.
The “Standard” heat mode is displayed in this example.
Note: Depending on your installed equipment, the
screen may look different.
With “Fast Keys” highlighted on the Home display
screen, press
or , then to return Home.
You can also change the Spa temperature from within
the menus: Set > Spa Settings > Set Temp >
Then press the left or right arrow keys to adjust the
temperature. To Save and Exit:
. Set the desired spa temperature with
.
, .
Front Panel Buttons and Lights
For instant activation of devices, press Jets 1, Jets 2,
Blower or Light. The left LEDs will light when activated.
The Right LEDs will light when HT (Heater), FC (Filter
Cycle), and OZ (Ozone Filter) are activated.
Jets 1 Button
Press the Jets 1 button once to turn pump 1 on or off,
and to shift between low and high speeds if equipped.
If left running, the pump will turn off after a timeout period. The pump 1 low speed time-out on some
systems may be as long as 4 hours.
On non-circ systems, the low speed of pump 1 runs
when the blower or any other pump is on. It may also
activate for at least 1 minute every 30 minutes to detect
the spa temperature (polling) and then to heat to the
set temperature if needed, depending upon mode.
When the low speed turns on automatically, it cannot
be deactivated from the panel; however, the high speed
may be started.
Jets 2 Button
102º F
Home Display Screen
Setting the Time
The time should be set first. All timed functions are
dependant on this. Starting at the Home display screen,
highlight “Set”, then press
Use the arrow keys to highlight “Time of Day”. Press
Press
Press
Press
To Save and Exit:
or to change hour. to highlight minutes.
or to change minutes. to highlight AM.
or to choose AM or PM.
, , .
.
Press the Jets 2 button once to turn pump 2 on or off,
and to shift between low and high speeds if it is a
two-speed pump. If left running, the pump will turn off
after a time-out period.
Blower Button
1-speed operation: On/Off
2-speed operation: High/Med/Off
3-speed operation: High/Med/Low/Off
If left on, the blower will automatically turn off after a
time-out period.
.
Page 2