Bakbar GE505C Installation Manual

INSTALLATION AND OPERATION MANUAL
GAS RANGES ELECTRIC STATIC / CONVECTION OVENS
GE505 GE54 GE506 GE56 GE508 GE58
230111-16
MANUFACTURED BY
Moffat Limited
Rolleston 7675 New Zealand
INTERNATIONAL CONTACTS
AUSTRALIA
Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3838
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk E.Mail: sales@blue-seal.co.uk Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711 Spares: (tel): +44 121 322 6640 (fax): +44 121 327 9201 Service: (tel): +44 121 322 6644 (fax): +44 121 327 6257
UNITED STATES
Moffat Web: www.moffat.com Sales: (tel): 800 551 8795 (Toll Free)
(tel): +1 336 661 1556 (fax): +1 336 661 9546 Service: (tel): 800 858 4477 (Toll Free) (tel): +1 336 661 1556 (fax): +1 336 661 1660
REST OF WORLD
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless auth orized previously in writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
© Copyright Moffat Ltd. December 2014.
Contents List
Blue Seal Gas Range Electric Static/Convection Ovens
GE505 Gas Range Electric Static Oven -750mm wide. GE506 Gas Range Electric Static Oven - 900mm wide. GE508 Gas Range Electric Static Oven - 1200mm wide.
GE54 Gas Range Electric Convection Oven - 750mm wide. GE56 Gas Range Electric Convection Oven - 900mm wide. GE58 Gas Range Electric Convection Oven - 1200mm wide.
Introduction .............................................................................................. 2
Specification .............................................................................................. 3
Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection Electrical Supply Requirements Electrical Connection
Dimensions ................................................................................................ 7
Installation .............................................................................................. 10
Installation Requirements Unpacking Location Clearances Assembly Gas Connection Electrical Connection Commissioning
Operation ................................................................................................. 14
Operation Guide Description of Controls Open Burners Griddle Oven
Cleaning and Maintenance ...................................................................... 17
Before Commencing Cleaning Open Burner Cleaning Griddle Plate Cleaning Oven Interior Cleaning Stainless Steel Surfaces
Fault Finding ............................................................................................ 20
Wiring Schematic .................................................................................... 22
Gas Conversion and Specifications ......................................................... 25
Conversion Procedure Gas Specifications
Replacement Parts List ............................................................................ 30
1
Introduction
We are confident that you will be delighted with your BLUE SEAL GAS RANGE ELECTRICAL STATIC / CONVECTION OVEN and it will become a most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Blue Seal appliance, there are two important things you can do.
Firstly:
Please read the instruction book carefully and follow directions given. The time taken will be well spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance, contact your BLUE SEAL dealer promptly. In many cases a phone call could answer your questi on.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for adapting the appliance to the conditions for use in that country.
Warning
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
INSTRUCTIONS LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT
Warning
Warning
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF
FIRE.
 T  I
 DO NOT

HE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
T IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO
ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.

This appliance is for professional use and is only to be used by qualified persons.

Only authorised service persons are to carry out installation, servicing or gas conversion operations.

Components having adjustments protected (e.g. paint sealed) by the manufacturer should not be adjusted by the user / operator.

DO NOT operate the appliance without the legs supplied fitted.
Caution
2
Model Numbers Covered in this Specification
GE505D[1] 4 Open Burners + Electric Static Oven. GE505C[1] 2 Open Burners + 300 mm Griddle + Electric Static Oven.
GE506D[1] 6 Open Burners + Electric Static Oven. GE506C[1] 4 Open Burners + 300 mm Griddle + Electric Static Oven. GE506B[1] 2 Open Burners + 600 mm Griddle + Electric Static Oven. GE506A[1] 900 mm Griddle + Electric Static Oven.
GE508D[1] 8 Open Burners + Electric Static Oven. GE508C[1] 6 Open Burners + 300 mm Griddle + Electric Static Oven. GE508B[1] 4 Open Burners + 600 mm Griddle + Electric Static Oven. GE508A[1] 2 Open Burners + 900 mm Griddle + Electric Static Oven.
GE54D[1] 4 Open Burners + Electric Convection Oven. GE54C[1] 2 Open Burners + 300 mm Griddle + Electric Convection Oven.
GE56D[1] 6 Open Burners + Electric Convection Oven. GE56C[1] 4 Open Burners + 300 mm Griddle + Electric Convection Oven. GE56B[1] 2 Open Burners + 600 mm Griddle + Electric Convection Oven. GE56A[1] 900 mm Griddle + Electric Convection Oven.
GE58D[1] 8 Open Burners + Electric Convection Oven. GE58C[1] 6 Open Burners + 300 mm Griddle + Electric Convection Oven. GE58B[1] 4 Open Burners + 600 mm Griddle + Electric Convection Oven. GE58A[1] 2 Open Burners + 900 mm Griddle + Electric Convection Oven.
[1] - Open Burner Options;
F - With Flame Failure Protection. PF - With Pilot and Flame Failure Protection.
General
Specifications
A heavy duty, general purpose Gas Range with Electric Static / Convection Oven created for compact modular kitchens. It has a high option Cook Top / Griddle arrangement and is available on industrial adjustable feet or on robust rollers.
Open Burners are available in either 'PF' (Pilot and Flame Failure) or 'F' (Flame Failure Only) options. Open Burner and Griddle options are fitted with individual flame failure for each open burner. Griddles are fitted with pilot, flame failure and piezo ignition as standard. Easy clean stainless steel external finish.
Easy clean stainless external finish.
3
Specifications
Gas Supply Requirements
- Australia
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure Burner Operating Pressure (*) Gas Connection
Natural Gas LP Gas (Propane)
28 MJ/hr
1.13 - 3.40 kPa 2.75 - 4.50 kPa
0.95 kPa 2.6 kPa See ‘Gas Connection’ information overleaf.
28 MJ/hr
- New Zealand
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure Burner Operating Pressure (*) Gas Connection
Natural Gas LP Gas
28 MJ/hr
1.13 - 3.40 kPa 2.75 - 4.50 kPa
0.95 kPa 2.6 kPa See ‘Gas Connection’ information overleaf.
28 MJ/hr
- United Kingdom
Category: II
2H3P
(20, 37).
Flue Type: A1.
Nominal
Heat Input (nett)
Gas Rate (nett)
Supply Pressure 20 mbar 37 mbar Burner Operating Pressure (*) 9.5 mbar Gas Connection See ‘Gas Connection’ information overleaf.
Reduced Pilot Nominal Reduced Pilot
Natural Gas (G20) Propane (G31)
Open Burner
(each)
6.5 kW 5.5 kW 6.5 kW 5.5 kW
1.75 kW 1.85 kW 1.75 kW 1.95 kW 200W 170W 200W 150W
0.69 m3/hr 0.58 m3/hr 0.51 kg/hr 0.43 kg/hr
0.19 m3/hr 0.20 m3/hr 0.14 kg/hr 0.15 kg/hr
0.02 m3/hr 0.02 m3/hr 0.02 kg/hr 0.01 kg/hr
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
26 mbar
* - Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’ section for details).
4
- All Other Markets
Specifications
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure Burner Operating Pressure (*) Gas Connection
Natural Gas Town Gas (**)
28 MJ/hr
1.13 - 3.40 kPa 0.75 - 1.50 kPa
0.95 kPa 0.63 kPa See ‘Gas Connection’ information overleaf.
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure Burner Operating Pressure (*) Gas Connection
Natural Gas LP Gas
28 MJ/hr
1.13 - 3.40 kPa 2.75 - 4.50 kPa
0.95 kPa 2.6 kPa See ‘Gas Connection’ information overleaf.
NOTE:
 (*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
 (**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
 Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
28 MJ/hr
28 MJ/hr
Gas supply connection point is located at rear of appliance:- For GE505 / GE54, located approximately 130mm from right hand side, 36mm from rear and
655mm from floor and is reached from beneath appliance. For GE506 / GE56, located approximately 130mm from right hand side, 32mm from rear and
655mm from floor and is reached from beneath appliance. For GE508 / GE58, located approximately 130mm from right hand side, 35mm from rear and
655mm from floor and is reached from beneath appliance.
Connection is ¾" BSP male thread (for all other models).
5
Specifications
Electrical Supply Requirements
MODEL
GE505
GE54
GE506
GE56
GE508
GE58
1-Phase Connection
1P+N+E
230-240V
5.5 kW,
22.6 Amps @ 235 V
5.8 kW,
23.9 Amps @ 235 V
6.5 kW,
26.6 Amps @ 235 V
6.8 kW,
27.9 Amps @ 235 V
6.5 kW,
26.6 Amps @ 235 V
6.8 kW,
27.9 Amps @ 235 V
3-Phase Connection
3P+N+E
400-415V
5.5 kW
5.8 kW
6.5 kW
6.8 kW
6.5 kW
6.8 kW
L1 - 7.2 Amps L2 - 7.7 Amps L3 - 7.7 Amps
L1 - 8.5 Amps L2 - 7.7 Amps L3 - 7.7 Amps
L1 - 8.2 Amps L2 - 9.2 Amps L3 - 9.2 Amps
L1 - 9.5 Amps L2 - 9.2 Amps L3 - 9.2 Amps
L1 - 8.2 Amps L2 - 9.2 Amps L3 - 9.2 Amps
L1 - 9.5 Amps L2 - 9.2 Amps L3 - 9.2 Amps
Electrical Connection
Warning
THIS APPLIANCE MUST BE EARTHED. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.
GE505 / 54 - GE506 / 56 Models Only.
Electrical supply connection point is located at rear of appliance, approximately 74mm from right hand side, 501mm from rear and 150mm from floor.
GE508 / 58 Models Only.
Electrical supply connection point is located at rear of appliance, approximately 374mm from right hand side, 501mm from rear and 150mm from floor.
When connecting this electric appliance to mains supply, ensure that the followi ng is carried out:-
 An isolating switch is fitted within 2m of appliance, but not on appliance and in such a position
that user does not have to reach across cooking surface.
 Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS/NZS 3191 part
2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
 Branch supply line shall be individually overload protected to correct current rating and supply
chord shall be protected against any mechanical or thermal damage.
 A grommet is fitted around wiring entry hole into appliance.  All wiring connections must be tight.
Refer to appropriate wiring standards for size of cable to be supplied to an appliance for current drawn on that line.
6
Dimensions GE505 / GE54
Dimensions
Dimensions GE506 / GE56
7
Refer to Page 8 for Cook Top Options
Dimensions
Dimensions GE508 / GE58
8
Refer to Page 8 for Cook Top Options
Cook Top Options
Dimensions
Cook Top Options GE505-D/GE54-D
Cook Top Options GE506-D/GE56-D
Cook Top Options GE505-C/GE54-C
Cook Top Options GE506-C/GE56-C
Cook Top Options GE506-B/GE56-B
Cook Top Options GE508-D/GE58-D
Cook Top Options GE506-A/GE56-A
Cook Top Options GE508-C/GE58-C
Cook Top Options GE508-B/GE58-B
Cook Top Options GE508-A/GE58-A
9
Loading...
+ 24 hidden pages