The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless auth orized previously in
writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and
design without prior notice.
Blue Seal Gas Range Electric Static/Convection Ovens
GE505 Gas Range Electric Static Oven -750mm wide.
GE506 Gas Range Electric Static Oven - 900mm wide.
GE508 Gas Range Electric Static Oven - 1200mm wide.
GE54 Gas Range Electric Convection Oven - 750mm wide.
GE56 Gas Range Electric Convection Oven - 900mm wide.
GE58 Gas Range Electric Convection Oven - 1200mm wide.
Gas Conversion and Specifications ......................................................... 25
Conversion Procedure
Gas Specifications
Replacement Parts List ............................................................................ 30
1
Introduction
We are confident that you will be delighted with your BLUE SEAL GAS RANGE ELECTRICAL STATIC /
CONVECTION OVEN and it will become a most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Blue Seal appliance, there are two important
things you can do.
Firstly:
Please read the instruction book carefully and follow directions given. The time taken will be well spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance,
contact your BLUE SEAL dealer promptly. In many cases a phone call could answer your questi on.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for
adapting the appliance to the conditions for use in that country.
This appliance is for professional use and is only to be used by qualified
persons.
Only authorised service persons are to carry out installation, servicing or gas
conversion operations.
Components having adjustments protected (e.g. paint sealed) by the
manufacturer should not be adjusted by the user / operator.
DO NOT operate the appliance without the legs supplied fitted.
Caution
2
Model Numbers Covered in this Specification
GE505D[1] 4 Open Burners + Electric Static Oven.
GE505C[1] 2 Open Burners + 300 mm Griddle + Electric Static Oven.
GE506D[1] 6 Open Burners + Electric Static Oven.
GE506C[1] 4 Open Burners + 300 mm Griddle + Electric Static Oven.
GE506B[1] 2 Open Burners + 600 mm Griddle + Electric Static Oven.
GE506A[1] 900 mm Griddle + Electric Static Oven.
GE508D[1] 8 Open Burners + Electric Static Oven.
GE508C[1] 6 Open Burners + 300 mm Griddle + Electric Static Oven.
GE508B[1] 4 Open Burners + 600 mm Griddle + Electric Static Oven.
GE508A[1] 2 Open Burners + 900 mm Griddle + Electric Static Oven.
GE54D[1] 4 Open Burners + Electric Convection Oven.
GE54C[1] 2 Open Burners + 300 mm Griddle + Electric Convection Oven.
GE56D[1] 6 Open Burners + Electric Convection Oven.
GE56C[1] 4 Open Burners + 300 mm Griddle + Electric Convection Oven.
GE56B[1] 2 Open Burners + 600 mm Griddle + Electric Convection Oven.
GE56A[1] 900 mm Griddle + Electric Convection Oven.
GE58D[1] 8 Open Burners + Electric Convection Oven.
GE58C[1] 6 Open Burners + 300 mm Griddle + Electric Convection Oven.
GE58B[1] 4 Open Burners + 600 mm Griddle + Electric Convection Oven.
GE58A[1] 2 Open Burners + 900 mm Griddle + Electric Convection Oven.
[1] - Open Burner Options;
F - With Flame Failure Protection.
PF - With Pilot and Flame Failure Protection.
General
Specifications
A heavy duty, general purpose Gas Range with Electric Static / Convection Oven created for compact
modular kitchens. It has a high option Cook Top / Griddle arrangement and is available on industrial
adjustable feet or on robust rollers.
Open Burners are available in either 'PF' (Pilot and Flame Failure) or 'F' (Flame Failure Only) options.
Open Burner and Griddle options are fitted with individual flame failure for each open burner.
Griddles are fitted with pilot, flame failure and piezo ignition as standard. Easy clean stainless steel
external finish.
Easy clean stainless external finish.
3
Specifications
Gas Supply Requirements
- Australia
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
Natural Gas LP Gas (Propane)
28 MJ/hr
1.13 - 3.40 kPa 2.75 - 4.50 kPa
0.95 kPa 2.6 kPa
See ‘Gas Connection’ information overleaf.
28 MJ/hr
- New Zealand
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
Natural Gas LP Gas
28 MJ/hr
1.13 - 3.40 kPa 2.75 - 4.50 kPa
0.95 kPa 2.6 kPa
See ‘Gas Connection’ information overleaf.
28 MJ/hr
- United Kingdom
Category: II
2H3P
(20, 37).
Flue Type: A1.
Nominal
Heat Input (nett)
Gas Rate (nett)
Supply Pressure 20 mbar 37 mbar
Burner Operating Pressure (*) 9.5 mbar
Gas Connection See ‘Gas Connection’ information overleaf.
* - Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be
adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’
section for details).
4
- All Other Markets
Specifications
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
Natural Gas Town Gas (**)
28 MJ/hr
1.13 - 3.40 kPa 0.75 - 1.50 kPa
0.95 kPa 0.63 kPa
See ‘Gas Connection’ information overleaf.
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
Natural Gas LP Gas
28 MJ/hr
1.13 - 3.40 kPa 2.75 - 4.50 kPa
0.95 kPa 2.6 kPa
See ‘Gas Connection’ information overleaf.
NOTE:
(*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
28 MJ/hr
28 MJ/hr
Gas supply connection point is located at rear of appliance:-
For GE505 / GE54, located approximately 130mm from right hand side, 36mm from rear and
655mm from floor and is reached from beneath appliance.
For GE506 / GE56, located approximately 130mm from right hand side, 32mm from rear and
655mm from floor and is reached from beneath appliance.
For GE508 / GE58, located approximately 130mm from right hand side, 35mm from rear and
655mm from floor and is reached from beneath appliance.
Connection is ¾" BSP male thread (for all other models).