Bakbar G512-B Installation Manual

INSTALLATION AND OPERATION MANUAL
GAS COOKTOP
Series G512 G514 G515 G516 G518
For use in GB, IE & DK
229363-15
MANUFACTURED BY
Moffat Limited
Rolleston 7675 New Zealand
INTERNATIONAL CONTACTS
AUSTRALIA
Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3838
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk E.Mail: sales@blue-seal.co.uk Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711 Spares: (tel): +44 121 322 6640 (fax): +44 121 327 9201 Service: (tel): +44 121 322 6644 (fax): +44 121 327 6257
UNITED STATES
Moffat Web: www.moffat.com Sales: (tel): 800 551 8795 (Toll Free)
(tel): +1 336 661 1556 (fax): +1 336 661 9546 Service: (tel): 800 858 4477 (Toll Free) (tel): +1 336 661 1556 (fax): +1 336 661 1660
REST OF WORLD
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
© Copyright Moffat Ltd. December 2014.
Contents
Blue Seal Gas Cooktops
G512 Gas Cooktop 300mm wide. G514 Gas Cooktop 600mm wide. G515 Gas Cooktop 750mm wide. G516 Gas Cooktop 900mm wide. G518 Gas Cooktop 1200mm wide.
Introduction .............................................................................................. 2
Specifications ............................................................................................ 3
Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection
Dimensions ................................................................................................ 6
Installation .............................................................................................. 11
Installation Requirements Unpacking Location Clearances Assembly Fitting the Leg Stand to the Cooktop Gas Connection Commissioning
Operation ................................................................................................. 15
Operation Guide Description of Controls Open Burners ('F' - Flame Failure Option) Open Burners ('PF' - Pilot and Flame Failure Option) Griddle
Cleaning and Maintenance ...................................................................... 18
Before Commencing Cleaning Open Burner Cleaning Griddle Plate Cleaning Stainless Steel Surfaces
Fault Finding ............................................................................................ 20
Gas Conversion and Specifications ......................................................... 21
Conversion Procedure Gas Specifications
Replacement Parts List ............................................................................ 26
Introduction
We are confident that you will be delighted with your BLUE SEAL COOKTOP, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new BLUE SEAL COOKTOP, there are two important things you can do.
Firstly:
Please read the instruction book carefully and follow the directions given. The time taken will be well
spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance,
contact your BLUE SEAL dealer promptly. In many cases a phone call could answer your questi on.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for
adapting the appliance to the conditions for use in that country.
Warning
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
INSTRUCTIONS LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT
Warning
Warning
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF
FIRE.
 T  I
 DO NOT

HE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
T IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO
ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.

This appliance is for professional use and is only to be used by qualified persons.

Only authorised service persons are to carry out installation, servicing or gas conversion operations.

Components having adjustments protected (e.g. paint sealed) by the manufacturer should not be adjusted by the user / operator.

DO NOT operate the appliance without the legs supplied fitted.
Caution
2
Model Numbers Covered in this Specification
G512D-[1]-[2] 2 Open Burners. G512C -[2] 300mm Griddle.
G514D-[1]-[2] 4 Open Burners. G514C-[1]-[2] 2 Open Burners + 300mm Griddle. G514B -[2] 600mm Griddle.
G515D-[1]-[2] 4 Open Burners. G516D-[1]-[2] 6 Open Burners.
G516C-[1]-[2] 4 Open Burners + 300mm Griddle. G516B-[1]-[2] 2 Open Burners + 600mm Griddle. G516A -[2] 900mm Griddle.
G518D-[1]-[2] 8 Open Burners. G518C-[1]-[2] 6 Open Burners + 300mm Griddle. G518B-[1]-[2] 4 Open Burners + 600mm Griddle. G518A-[1]-[2] 2 Open Burners + 900mm Griddle.
[1] - Open Burner Options;
F - With Flame Failure Protection. PF - With Pilot and Flame Failure Protection.
[2] - Base Stand Options;
B - Bench Mount. CB - Cabinet Base (excluding G512 series). LS - Leg Stand (excluding G512 series). RB - Refrigerated Base (G516 and G518 series only).
General
Specifications
A heavy duty, high efficiency Cooktop for modular kitchens. It has a high option Cooktop / Griddle arrangement and is available either on industrial adjustable feet or on robust rollers. Griddle options with 4 models of base unit available (except G512 Model). Fitted with either 'Individual Flame Failure' (F) or 'Pilot and Flame Failure' (PF) option for each open burner. Griddles are fitted with pilot, flame failure and piezo ignition as standard. Easy clean stainless steel external finish.
3
Specifications
Gas Supply Requirements
- Australia
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure Burner Operating Pressure (*) Gas Connection
Natural Gas LP Gas (Propane)
28 MJ/hr
1.13 - 3.40 kPa 2.75 - 4.50 kPa
0.95 kPa 2.6 kPa See ‘Gas Connection’ information overleaf.
28 MJ/hr
- New Zealand
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure Burner Operating Pressure (*) Gas Connection
Natural Gas LP Gas
28 MJ/hr
1.13 - 3.40 kPa 2.75 - 4.50 kPa
0.95 kPa 2.6 kPa See ‘Gas Connection’ information overleaf.
28 MJ/hr
- United Kingdom
Category: II
2H3P
(20, 37).
Flue Type: A1.
Heat Input (nett)
Gas Rate (nett)
Supply Pressure 20 mbar 37 mbar Burner Operating Pressure (*) 9.5 mbar Gas Connection See ‘Gas Connection’ information overleaf.
Nominal Reduced Nominal Reduced
Natural Gas (G20) Propane (G31)
Open Burner
(each)
6.5 kW 5.5 kW 6.5 kW 5.5 kW
1.75 kW 1.85 kW 1.75 kW 1.95 kW
0.69 m3/hr 0.58 m3/hr 0.51 kg/hr 0.43 kg/hr
0.19 m3/hr 0.20 m3/hr 0.14 kg/hr 0.15 kg/hr
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
26 mbar
* - Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’ section for details).
4
- All Other Markets
Specifications
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure Burner Operating Pressure (*) Gas Connection
Natural Gas Town Gas (**)
28 MJ/hr
1.13 - 3.40 kPa 0.75 - 1.50 kPa
0.95 kPa 0.63 kPa See ‘Gas Connection’ information overleaf.
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure Burner Operating Pressure (*) Gas Connection
LP Gas (Propane) Butane
28 MJ/hr
2.75 - 4.50 kPa 2.75 - 4.50 kPa
2.6 kPa 2.6 kPa See ‘Gas Connection’ information overleaf.
NOTE:
 (*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
 (**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
 Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
28 MJ/hr
28 MJ/hr
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand side, 32mm from rear and 655mm from floor (55mm for bench top – B models) and is reached from beneath appliance. (Refer to ‘Dimensions’ section). With exception of G512C and G512D models which are 100mm from right hand side, 32mm from rear and 70mm from floor.
Connection is ½" BSP male thread (for G512C and G512D models). Connection is ¾" BSP male thread (for all other models).
5
Dimensions
Dimensions for Bench Models
G512-B
G514-B
R
= Rating Plate Location for
R
this option.
G516-B
G518-B
6
Refer to Page 9 for Cooktop Options
Dimensions for Cabinet Base Models
G512 models - not available in Cabinet Base option.
Dimensions
G514-CB
G516-CB
R
= Rating Plate Location for
R
this option.
G518-CB
Refer to Page 9 for Cooktop Options
7
Loading...
+ 21 hidden pages