Gas Conversion and Specifications ......................................................... 21
Conversion Procedure
Gas Specifications
Replacement Parts List ............................................................................ 26
Introduction
We are confident that you will be delighted with your BLUE SEAL COOKTOP, and it will become a most
valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new BLUE SEAL COOKTOP, there are two important
things you can do.
Firstly:
Please read the instruction book carefully and follow the directions given. The time taken will be well
spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance,
contact your BLUE SEAL dealer promptly. In many cases a phone call could answer your questi on.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for
adapting the appliance to the conditions for use in that country.
This appliance is for professional use and is only to be used by qualified
persons.
Only authorised service persons are to carry out installation, servicing or gas
conversion operations.
Components having adjustments protected (e.g. paint sealed) by the
manufacturer should not be adjusted by the user / operator.
DO NOT operate the appliance without the legs supplied fitted.
Caution
2
Model Numbers Covered in this Specification
G512D-[1]-[2] 2 Open Burners.
G512C -[2] 300mm Griddle.
G514D-[1]-[2] 4 Open Burners.
G514C-[1]-[2] 2 Open Burners + 300mm Griddle.
G514B -[2] 600mm Griddle.
G515D-[1]-[2] 4 Open Burners.
G516D-[1]-[2] 6 Open Burners.
G516C-[1]-[2] 4 Open Burners + 300mm Griddle.
G516B-[1]-[2] 2 Open Burners + 600mm Griddle.
G516A -[2] 900mm Griddle.
G518D-[1]-[2] 8 Open Burners.
G518C-[1]-[2] 6 Open Burners + 300mm Griddle.
G518B-[1]-[2] 4 Open Burners + 600mm Griddle.
G518A-[1]-[2] 2 Open Burners + 900mm Griddle.
[1] - Open Burner Options;
F - With Flame Failure Protection.
PF - With Pilot and Flame Failure Protection.
[2] - Base Stand Options;
B - Bench Mount.
CB - Cabinet Base (excluding G512 series).
LS - Leg Stand (excluding G512 series).
RB - Refrigerated Base (G516 and G518 series only).
General
Specifications
A heavy duty, high efficiency Cooktop for modular kitchens. It has a high option Cooktop / Griddle
arrangement and is available either on industrial adjustable feet or on robust rollers. Griddle options
with 4 models of base unit available (except G512 Model). Fitted with either 'Individual Flame
Failure' (F) or 'Pilot and Flame Failure' (PF) option for each open burner. Griddles are fitted with
pilot, flame failure and piezo ignition as standard. Easy clean stainless steel external finish.
3
Specifications
Gas Supply Requirements
- Australia
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
Natural Gas LP Gas (Propane)
28 MJ/hr
1.13 - 3.40 kPa 2.75 - 4.50 kPa
0.95 kPa 2.6 kPa
See ‘Gas Connection’ information overleaf.
28 MJ/hr
- New Zealand
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
Natural Gas LP Gas
28 MJ/hr
1.13 - 3.40 kPa 2.75 - 4.50 kPa
0.95 kPa 2.6 kPa
See ‘Gas Connection’ information overleaf.
28 MJ/hr
- United Kingdom
Category: II
2H3P
(20, 37).
Flue Type: A1.
Heat Input (nett)
Gas Rate (nett)
Supply Pressure 20 mbar 37 mbar
Burner Operating Pressure (*) 9.5 mbar
Gas Connection See ‘Gas Connection’ information overleaf.
Nominal
Reduced
Nominal
Reduced
Natural Gas (G20) Propane (G31)
Open Burner
(each)
6.5 kW 5.5 kW 6.5 kW 5.5 kW
1.75 kW 1.85 kW 1.75 kW 1.95 kW
0.69 m3/hr 0.58 m3/hr 0.51 kg/hr 0.43 kg/hr
0.19 m3/hr 0.20 m3/hr 0.14 kg/hr 0.15 kg/hr
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
26 mbar
* - Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be
adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’
section for details).
4
- All Other Markets
Specifications
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
Natural Gas Town Gas (**)
28 MJ/hr
1.13 - 3.40 kPa 0.75 - 1.50 kPa
0.95 kPa 0.63 kPa
See ‘Gas Connection’ information overleaf.
Input Rate (N.H.G.C.)
- each Open Burner
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
LP Gas (Propane) Butane
28 MJ/hr
2.75 - 4.50 kPa 2.75 - 4.50 kPa
2.6 kPa 2.6 kPa
See ‘Gas Connection’ information overleaf.
NOTE:
(*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
28 MJ/hr
28 MJ/hr
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear and 655mm from floor (55mm for bench top – B models) and is reached from
beneath appliance. (Refer to ‘Dimensions’ section). With exception of G512C and G512D models
which are 100mm from right hand side, 32mm from rear and 70mm from floor.
Connection is ½" BSP male thread (for G512C and G512D models).
Connection is ¾" BSP male thread (for all other models).
5
Dimensions
Dimensions for Bench Models
G512-B
G514-B
R
= Rating Plate Location for
R
this option.
G516-B
G518-B
6
Refer to Page 9 for Cooktop Options
Dimensions for Cabinet Base Models
G512 models - not available in Cabinet Base option.
Dimensions
G514-CB
G516-CB
R
= Rating Plate Location for
R
this option.
G518-CB
Refer to Page 9 for Cooktop Options