TECHNICAL SPECIFICATION SHEET FOR
Blue Seal Gas Combi Steamer
AC SERIES G40AC PD 40 x 1/1GN or 20 x 2/1
Electronic manual control panel with
cooking modes
Programmable with 91 program cycles
Electronic thermostat 30°C - 300°C
Electronic timer
Auto-reversing fan rotation
Cavity fast cool down which automatically
stops at 50°C
Automatic cavity cool down between high
temperature cycles and the next cycle
featuring a lower temperature
Autoclima automatic humidity control
system
Automatic vent to evacuate the excess
humidity
GENERAL FEATURES:
- Direct steam injection system
- High efficiency heat exchanger and gas burner
system
- Stainless steel construction
- Hygienic rounded corners in oven cavity
- Pivoting fan suction panel
- Front removable control panel for easy
servicing
- Hygienic plug-in door seal for easy to
remove day-to-day cleaning
- Adjustable door hinges
- Self draining door condensate drip tray
- Hand shower
- Oven lights
- Oven door handle with progressive brake
mechanism
- Cool to touch double glazed door
Automatic quenching of vapours into the
oven drain
Cavity clean program
Energy saving device for reduced energy
consumption
- Hinged inner glass for easy cleaning
- Constant self-diagnosis for error
recognition
OPTIONAL FEATURES:
- Interchangeable core probes with external socket
- Marine and special voltages
- LPG Version
- Connection for an external printer (type RS232)
- Connection for energy saving system
TECHNICAL SPECIFICATION SHEET FOR
Blue Seal Gas Combi Steamer
AC SERIES G40AC PD 40 x 1/1GN or 20 x 2/1
Dimensions
Width 1290mm
Depth 895mm
Height 1950mm
Weight 450kg
Packed Dimensions
Width 1420mm
Depth 1220mm
Height 2250mm
Weight 560kg
Shelves
1/1 GN 40
2/1 GN 20
Shelf Spacings 67mm
Installation requirements
(for precise installation
instructions, please refer to
the unit’s installation manual).
Power connection
requirements
Multi pole circuit breaker and
all pole disconnection isolator
switch installed near the
appliance.
Supply line voltage;
230-240V ~ 50Hz, 1P+N+E
Gas connection for Natural or
LPG R1/2.
Gas Connection
Nominal Gas Consumption
(kW) 54
(MJ/hr) 194
Electrical Connection (kW)1.8
Rated Current (A) (230V) 7.8
Exhaust connection to
ventilation system with safety
switch.
Observe regulations for gas
suppliers.
IPX5 spray-proof and hose
proof.
Installation clearances
- rear 25mm
- right 500mm*
- left 50mm
*Clearance required on fixed
installations for service
accessibility.
If heat sources are located
near the RH side of the AC
combi, ensure that a
minimum distance of 400mm
is maintained.
Install in accordance with local
body regulations only on
horizontal surfaces and not
against combustible walls.
Water connection
requirements
- cold water
- flow pressure (2 to 6 bar)
- soft water connection*
- shut-off valve with return
flow inhibitor and dirt filter
- water supply R3/4
- R50 waste water connection
(*Water softener may be
required. Please refer to
installation manual for water
treatment values.)
A = WATER CONNECTION R3/4
(SOFTENED WATER) refer to installation
manual for water treatment values.
B = WATER CONNECTION R
C = DRAIN CONNECTION Ø50
D = ELECTRICAL CONNECTION ENTRY
E = HIGH/LOW PRESSURE RELIEF VENT
F = OVEN VENT Ø80
G = GAS SUPPLY ENTRY R
H = GAS FLUE OUTLET Ø80
3
/4
1
/2
Australia
www.moffat.com.au
New Zealand
www.moffat.co.nz
Australia
Moffat Pty Limited
Victoria/Tasmania
740 Springvale Road
Mulgrave, Victoria 3170
Ph 03-9518 3888
Fax 03-9518 3833
vsales@moffat.com.au
www.moffat.com.au
New South Wales
Ph 02-8833 4111
nswsales@moffat.com.au
South Australia
Ph 03-9518 3888
vsales@moffat.com.au
Queensland
Ph 07-3630 8600
qldsales@moffat.com.au
Western Australia
Ph 08-9202 6820
bgarcia@moffat.com.au
New Zealand
Moffat Limited
Christchurch
16 Osborne Street
Christchurch 8011
Ph +64 3-389 1007
Fax +64 3-389 1276
sales@moffat.co.nz
Auckland
Ph +64 9-574 3150
sales@moffat.co.nz
Optional Extras
SC Core temperature probe
HKST40 Extra roll-in trolley to suit 40AC PD
HKPT40 Plate banqueting trolley to suit 40AC PD
CPT40 Thermal cover for plate banqueting system to suit 40AC PD
In line with policy to continually develop
and improve its products, Moffat Limited
reserves the right to change
specifications and design without notice.
© Copyright Moffat Ltd
Moffat 6.08/1102