Bakbar G20CSD User Manual

TECHNICA L SPECIFICATION SHE E T FOR
Blue Seal Gas Combi Steamer
S LINE G20CSD, G20CSDW 20 x 1/1 GN or 10 x 2/1 GN
• Manual controls
• Easy to read displays
• Core temperature probe
• Two speed fan
• 92 preset recipe programs
• 99 free programs with 4 cycles,
automatic sequence
• Electronic thermostat 30° - 300°C
• Autoclima with automatic vent
• Oven light
• Hand shower
• Semi automatic washing programme
GENERAL FEATURES:
- Direct steam injection system
- High efficiency heat exchanger and gas burner system
- Stainless steel construction
- Hygienic rounded corners in oven cavity
- Pivoting fan suction panel
- Front removable control panel for easy servicing
- Hygienic plug-in door seal for easy to remove day-to-day cleaning
- Adjustable door hinges
- Self draining door condensate drip tray
- Oven light
- Oven door handle mechanism allows either left or right operation
- Cool to touch double glazed door
• Fully automatic wash system
(W version only)
• 4 LED’s to indicate actual cooking cycle
in programme mode
• Rack runners for GN loading
- Hinged inner glass for easy cleaning
- Constant self-diagnosis for error recognition
OPTIONAL FEATURES:
- Right hinged door
- Marine and special voltages
- Side runners for 600 x 400 trays (8 trays)
- Connection for an external printer (type RS232)
TECHNICA L SPECIFICATION SHE E T FOR
Blue Seal Gas Combi Steamer
S LINE G20CSD, G20CSDW 20 x 1/1 GN or 10 x 2/1 GN
Dimensions
Width 1170mm
Depth 895mm Height 1090mm Weight 270kg
Packed Dimensions
Width 1320mm Depth 1040mm Height 1220mm Weight 295kg
Shelves
1/1 GN 20 2/1 GN 10
Shelf Spacings 70mm
Installation requirements
(for precise installation instructions, please refer to the unit’s installation manual).
Power connection requirements
Supply line voltage;
230-240V ~ 50Hz, 1P+N+E Gas connection for Natural
or LPG R1/2.
Gas Connection
Nominal Gas Consumption
(MJ/hr) 100
Electrical Connection
(kW) 1.0
Rated Current (A) (230V) 4.3 3 pin plug (10A) cordset
fitted
Exhaust connection to ventilation system with safety switch.
Observe regulations for gas suppliers.
IPX5 spray-proof and hose proof.
Installation clearances
- rear 25mm
- right 500mm*
- left 50mm *Clearance required on
fixed installations for service accessibility.
If heat sources are located near the RH side of the AC combi, ensure that a minimum distance of 400mm is maintained.
Install in accordance with local body regulations only on horizontal surfaces and not against combustible walls.
Water connection requirements
- cold water
- flow pressure (200-500kPa)
- soft water connection*
- shut-off valve with return f
low inhibitor and dirt filter
- water supply R3/4
- R50 waste water connection
(*Water softener may be required. Please refer to installation manual for water treatment values.)
Australia
www.moffat.com.au
New Zealand
www.moffat.co.nz
Australia Moffat Pty Limited
Victoria/Tasmania 740 Springvale Road Mulgrave, Victoria 3170
Ph 03-9518 3888
Fax 03-9518 3833 vsales@moffat.com.au www.moffat.com.au
New South Wales Ph 02-8833 4111 nswsales@moffat.com.au
South Australia
Ph 03-9518 3888
vsales@moffat.com.au
Queensland Ph 07-3630 8600 qldsales@moffat.com.au
Western Australia
Ph 08-9202 6820
bgarcia@moffat.com.au
New Zealand Moffat Limited
Christchurch 16 Osborne Street Christchurch 8011
Ph +64 3-389 1007
Fax +64 3-389 1276 sales@moffat.co.nz
Auckland Ph +64 9-574 3150
sales@moffat.co.nz
A = WATER CONNECTION R3/
(SOFTENED WATER) refer to installation manual for water treatment values. B = WATER CONNECTION R C = DRAIN CONNECTION Ø60 D = ELECTRICAL CONNECTION ENTRY E = HIGH/LOW PRESSURE RELIEF VENT F = OVEN VENT Ø80 G = GAS SUPPLY ENTRY R H = GAS FLUE OUTLET Ø80
4
3
4
/
1
2
/
In line with policy to continually develop and improve its products, Moffat Limited reserves the right to change specifications and design without notice.
© Copyright Moffat Ltd Moffat 04.11/1176