Bakbar G1100 Service Manual

G1100 TURBOFAN OVEN
MANUFACTURED BY
Moffat Limited PO Box 10001 Christchurch New Zealand Ph: (03) 389 1007 Fax: (03) 389 1276
WORLD-WIDE BRANCHES
UNITED KINGDOM
Blue Seal 67 Gravelly Business Park Gravelly Park Birmingham West Midlands B24 8TQ Ph: (121) 327 5575 Fax: (121) 327 9711
UNITED STATES
Moffat Inc 3765 Champion Blvd Winston-Salem North Carolina 27115 Ph: (336) 661 0257 Fax: (336) 661 9546
CANADA
Serve Canada 22 Ashwarren Road Downview Ontario M3J1Z5
Toll Free:800 263 1455 Ph: (416) 631 0601 Fax: (416) 631 0315
info@servecanada.com www.servecanada.com www.moffat.com
NEW ZEALAND
Christchurch Auckland
Moffat Limited Moffat Limited PO Box 10-001 4 Waipuna Road 16 Osborne Street Mt Wellington Christchurch Auckland Ph: (03) 389 1007 Ph: (09) 574 3150 Fax: (03) 389 1276 Fax: (09) 574 3159
AUSTRALIA
Victoria New South Wales
Moffat Pty Limited Moffat Pty Limited 740 Springvale Road 3/142 James Ruse Drive, Rose Hill Mulgrave, Melbourne PO Box 913, Smithfield Victoria 3171 Sydney, N.S.W. 2142 Ph: (03) 9518 3888 Ph: (02) 8833 4111 Fax: (03) 9518 3838 Fax: (02) 8833 4133
Western Australia Queensland Moffat Pty Limited Moffat Pty Limited 67 Howe Street 30 Prosperity Place Osbourne Park Geebung, Brisbane WA 6017 Queensland 4034 Ph: (08) 9202 6820 Ph: (07) 3630 8600 Fax: (08) 9202 6836 Fax (07) 3630 8623
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
G1100 TURBOFAN OVEN
CONTENTS PAGE
INTRODUCTION 1
SPECIFICATION 2
INSTALLATION DOUBLE UNITS 5
OPERATION
- OVEN TEMP 7
- ROAST 'N HOLD 7
- INSTANT HOLD 7
- WATER 7
- LIGHTS 7
- COOKING GUIDE 8
- BAKING 8
- BAKING GUIDE 8
- ROASTING 9
- ROASTING GUIDE 9
CLEANING 10
FAULT DIAGNOSIS 11
SERVICING
- GAS CONVERSION 12
- BURNERS 12
- ELECTRICAL 13
SPARES 16
DOUBLE UNIT ASSEMBLY 18
CIRCUIT SCHEMATIC 19
Date Purchased....................................................................... Serial No...................................................
Dealer..........................................................................................................................................................
Service Agent..............................................................................................................................................
232479-3
INTRODUCTION
We are confident that you will be delighted with your TURBOFAN OVEN, and it will become the most valued appliance in your kitchen.
Your new oven may seem very complex and confusing at first glance. To ensure you receive the most benefit from your new turbofan, there are two important things you can do.
Firstly Please read the instruction book carefully and follow the directions given. The time taken will be well spent.
Secondly If you are unsure of any aspect of the installation, instructions or performance of your oven, contact your BLUE SEAL dealer promptly. In many cases a phone call could answer your questions.
THIS APPLIANCE IS FOR PROFESSIONAL USE AND IS ONLY TO BE USED
BY QUALIFIED PEOPLE
FOR YOUR SAFETY:
DO NOT store or use gasoline or other flammable vapours or liquids in the vicinity of this or any
other appliance.
DO NOT spray aerosols in the vicinity of this appliance while it is in operation.
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
DO NOT operate the oven without the legs supplied fitted.
-1-
SPECIFICATION
NOMINAL HOURLY GAS CONSUMPTION
Natural Gas 73MJ/hr LP Gas (Propane / Butane) 73MJ/hr Town Gas 73MJ/hr
GAS PRESSURE
Min Supply Max Supply Operating Pressure
Natural Gas 1.13kPa 5.0kPa 0.90kPa LP Gas (Propane / Butane) 2.75kPa 5.0kPa 2.50kPa Town Gas 0.75kPa 2.0kPa 0.16kPa
INJECTOR SIZES
Main Burner Pilot Runner
Natural Gas 2.00mm 1.10mm LP Gas / Propane 1.30mm 0.50mm Butane 1.20mm 0.50mm Town Gas 4.50mm 2.00mm
PRESSURE TEST POINT
Located below control panel. Accessible for manometer connection from underside of chassis.
ELECTRICAL RATING
- 230-240 volt, 50Hz, 1P+N+E, 2.1A
- 220 volt, 60Hz, 1P+N+E, 2.1A
OVERALL DIMENSIONS
Width 1005mm Height 1390mm Depth 980mm
DATA PLATE
Located on the R/H side of the oven exterior.
Data Plate shows: Model Number, Serial Number, Injector Size, Total MJ rating, Type
of Gas, Test Point Pressure.
-2-
G1100
SPECIFICATION
310
MWS
1005
60
930
50
MWS
205280
E
1
E
1
1390
715
660
70135
Front
MWS
Side
E
1
Plan
-3-
G1100 - 2
SPECIFICATION
310
MWS
MWS
1005
60
930
50
MWS
GASGAS
E
1
E
1
E
1
MWS
GASGAS
E
1
1690
Front
MWS
285 280 205 245
230
70135
Side
E
1
GAS
Plan
-4-