TECHNICA L SPECIFICATION SHE E T FOR
Blue Seal Electric Combi Steamer
S LINE E21CSD, E21CSDW 20 x 1/1 GN
• Manual controls
• Easy to read displays
• Core temperature probe
• Two speed fan
• 92 preset recipe programs
• 99 free programs with 4 cycles,
automatic sequence
• Electronic thermostat 30° - 300°C
• Auto-reversing fan rotation
• Autoclima with automatic vent
• Oven light
• Hand shower
• Semi automatic washing programme
GENERAL FEATURES:
- Direct steam injection system
- Stainless steel construction
- Hygienic rounded corners in oven cavity
- Pivoting fan suction panel
- Front removable control panel for easy
servicing
- Hygienic plug-in door seal for easy to remove
day-to-day cleaning
- Adjustable door hinges
- Self draining door condensate drip tray
- Oven light
- Oven door handle mechanism allows either left
or right operation
- Cool to touch double glazed door
- Hinged inner glass for easy cleaning
- Constant self-diagnosis for error recognition
- Includes trolley with front brake castors
• Fully automatic wash system
(W version only)
• 4 LED’s to indicate actual cooking cycle
in programme mode
• Trolley with rack runners for GN loading
OPTIONAL FEATURES:
- Marine and special voltages
- Connection for an external printer (type RS232)
TECHNICA L SPECIFICATION SHE E T FOR
Blue Seal Electric Combi Steamer
S LINE E21CSD, E21CSDW 20 x 1/1 GN
Dimensions
Width 950mm
Depth 895mm
Height 1950mm
Weight 310kg
Packed Dimensions
Width 1130mm
Depth 1050mm
Height 2220mm
Weight 400kg
Shelves
1/1 GN 20
Shelf Spacings 67mm
Installation requirements
(for precise installation
instructions, please refer to
the unit’s installation
manual).
Power connection
requirements
Multi pole circuit breaker
and all pole disconnection
isolator switch installed
near the appliance.
Supply line voltage;
400-415V ~ 50Hz, 3P+N+E
Special voltage options
available on request.
Power Connection
Total (kW) 31.8
Convection power (kW) 30
Rated Current (A) (400V) 46
IPX5 spray-proof and hose
proof.
Installation clearances
- rear 25mm
- right 500mm*
- left 50mm
*Clearance required on
fixed installations for
service accessibility.
If heat sources are located
near the RH side of the AC
combi, ensure that a
minimum distance of
400mm is maintained.
Install in accordance with
local body regulations only
on horizontal surfaces and
not against combustible
walls.
Water connection
requirements
- cold water
- flow pressure
(200-500kPa)
- soft water connection*
- shut-off valve with return
flow inhibitor and dirt filter
- water supply R3/4
- R50 waste water
connection
(*Water softener may be
required. Please refer to
installation manual for
water treatment values.)
Australia
www.moffat.com.au
New Zealand
www.moffat.co.nz
Australia
Moffat Pty Limited
Victoria/Tasmania
740 Springvale Road
Mulgrave, Victoria 3170
Ph 03-9518 3888
Fax 03-9518 3833
vsales@moffat.com.au
www.moffat.com.au
New South Wales
Ph 02-8833 4111
nswsales@moffat.com.au
South Australia
Ph 03-9518 3888
vsales@moffat.com.au
Queensland
Ph 07-3630 8600
qldsales@moffat.com.au
Western Australia
Ph 08-9202 6820
bgarcia@moffat.com.au
New Zealand
Moffat Limited
Christchurch
16 Osborne Street
Christchurch 8011
Ph +64 3-389 1007
Fax +64 3-389 1276
sales@moffat.co.nz
Auckland
Ph +64 9-574 3150
sales@moffat.co.nz
A = WATER CONNECTION R3/
(SOFTENED WATER) refer to
installation manual for water
treatment values.
B = WATER CONNECTION R
C = DRAIN CONNECTION Ø50
D = ELECTRICAL CONNECTION ENTRY
E = HIGH/LOW PRESSURE RELIEF VENT
F = OVEN VENT Ø80
4
3
4
/
In line with policy to continually
develop and improve its products,
Moffat Limited reserves the right to
change specifications and design
without notice.
© Copyright Moffat Ltd
Moffat 04.11/1176