Blue Seal Electric Combi Steamer
SAPIENS E20SDW 20 x 1/1 GN or 10 x 2/1 GN
• Manual controls
• Direct steam injection system
• Multi-point core temperature probe
• High visibility display
• Two speed fan
• 90 preset recipe programs
• 99 free programs with 4 cycles, automatic sequence
• Multiprogram keypad for quick, “press and go”
program selection with nine positions
• Electronic thermostat 30° - 300°C
• Auto-reversing fan rotation
• Autoclima with automatic vent
• Fast-Dry, quick dehumidification of the cooking
chamber
• Built-in retractable hand shower with tap
• SCS (Solid Clean System) automatic cleaning system
with built in tank and automatic detergent dispenser
• 4 LED’s to indicate actual cooking cycle in
programme mode
• ECOVAPOR - automatic control of the steam
saturation in the cooking chamber
• ECOSPEED - oven optimises and controls the delivery
of energy to maintain correct cooking temperature
• USB connection
GENERAL FEATURES
- INCOLOY 800 type heating elements
- Stainless steel construction
- Perfectly smooth, water tight chamber
- Adjustable door hinge for optimal seal
- Halogen oven light
- Oven door handle mechanism allows either left
or right operation
- Cool to touch door with double tempered glass with air
chamber and interior heat-reflective glass
ECOVAPOR ECOSPEED AUTOCLIMA FAST-DRY
- Hinged inner glass for easy cleaning
- Constant self-diagnosis for error recognition
- IPX5 spray-proof and hose proof.
- Rack runners for GN loading
OPTIONAL FEATURES
- Right hinged door
- Side runners for 600 x 400 trays
- Configuration for connection to extraction hood
SOLID CLEAN
Blue Seal Electric Combi Steamer
SAPIENS E20SDW 20 x 1/1 GN or 10 x 2/1 GN
Dimensions
Wid th 1170mm
Depth 895mm
Height 1040mm
Weight 201kg
Packed Dimensions
Width 1220mm
Depth 1040mm
Height 1250mm
Weight 226kg
Shelves
1/1 GN 20
2/1 GN 10
Shelf Spacings 70mm
Installation requirements
(for precise installation
instructions, please refer to
the unit’s installation
manual).
Power connection
requirements
Multi pole circuit breaker
and all pole disconnection
isolator switch installed
near the appliance.
Supply line voltage
400-415V ~ 50Hz, 3P+N+E
Special voltage options
available on request.
Power Connection
Total (kW) 31
Convection power (kW) 30
Rated Current (A) (400V) 46
Installation clearances
- rear 25mm
- right 500mm*
- left 50mm
*Clearance required on
fixed installations for
service accessibility.
If heat sources are located
near the RH side of the
Sapiens combi, ensure that a
minimum distance of
400mm is maintained.
Install in accordance with
local body regulations only
on horizontal surfaces and
not against combustible
350 10 810
50 835 60
walls.
Water connection
requirements
- cold water
- flow pressure
(200-500kPa)
- soft water connection*
- shut-off valve with return
flow inhibitor and dirt
filter
- water supply R3/4
- R50 waste water
connection
(*Water softener may be
required. Please refer to
installation manual for
water treatment values.)
Australia
www.moffat.com.au
New Zealand
www.moffat.co.nz
Australia
Moffat Pty Limited
Victoria/Tasmania
740 Springvale Road
Mulgrave, Victoria 3170
Ph 03-9518 3888
Fax 03-9518 3833
vsales@moffat.com.au
www.moffat.com.au
New South Wales
Ph 02-8833 4111
nswsales@moffat.com.au
South Australia
Ph 03-9518 3888
vsales@moffat.com.au
Queensland
Ph 07-3630 8600
qldsales@moffat.com.au
Western Australia
Ph 08-9202 6820
bgarcia@moffat.com.au
1040
1020 20
895
1170
New Zealand
Moffat Limited
880 160
ø3/4 ø3/4
ø50
Christchurch
16 Osborne Street
Christchurch 8011
Ph +64 3-389 1007
70
45
ø50
105
3AC 230V n°4x6mmq
3NAC 400V n°5x2.5mmq
53
44
80 110
260
120
55
Fax +64 3-389 1276
sales@moffat.co.nz
Auckland
Ph +64 9-574 3150
sales@moffat.co.nz
516
ø50
180
In line with policy to continually develop
and improve its products, Moffat
Limited reserves the right to change
specifications and design without notice.
© Copyright Moffat Ltd
Moffat 7.14 / 1413