HR-LCD 4-20 Scaled/Unscaled Register
DESCRIPTION
The High Resolution 4-20 scaled/unscaled register (HR-LCD 4-20
scaled/unscaled) is a fully electronic, solid-state register with no
moving parts. It is designed for use with all current Badger Meter®
Recordall® Disc Series, Turbo Series, Compound Series, Combo Series
and Fire Service meters and assemblies. These solid-state units
produce a scaled/unscaled output as well as a 4-20 mA DC output
signal through a dual output wire design.
OTE:N For more detailed information, see the user manual,
High Resolution LCD Encoders, available
at www.badgermeter.com.
Field Programmable: The HR-LCD 4-20 scaled/unscaled register
comes standard as factory programmed, with the option for field
programming the unit of measure, meter type, meter model,
rate-of-flow time and units, and the analog output. Programming
is performed through the IR port via a computer using the
Programmer software, version 2.0.0 or greater.
Output Resolution: The output resolution table in this document
lists the minimum output resolution for all Recordall meters.
Scaled Output:
• The scaled output is a switch closure output defined as:
red wire = positive, black wire = negative.
• The scaled digital output from the register has a default
resolution of 1/10th of the register test circle (resolution may
vary in some cases).
• The movement of the meter magnet is converted to a square
wave signal that is available as a scaled output through a
solid-state relay.
• The scaled output is a solid-state relay to provide isolation from
the 4-20 mA output.
• The nominal pulse output width is programmable from
30…100 msec.
• Resolution of the output is defined in the registration section.
• This digital pulse output is compatible with most totalizers and
batch controllers.
Unscaled Output:
• The unscaled output is a switch closure output defined as:
green wire = positive, black wire = negative.
• The movement of the meter magnet is converted to a square
wave signal that is available as an unscaled output through a
solid-state relay.
• The unscaled output is a solid state relay to provide isolation
from the 4-20 mA output.
• Resolution of the output is defined in the registration section.
• The unscaled output will only be active when the device is
powered by the 4-20 mA output.
• This digital pulse output is compatible with most totalizers and
batch controllers.
Analog Output:
• The input pulses generated within the transmitter assembly are
converted to a standard 4-20 mA control signal.
• This signal is proportional to the flow of fluid passing through
the flow meter.
• Power for the device can be obtained from a 9…50V DC
control loop.
• The default 20mA setting of the signal is defined in the
registration section.
Mounting: The fully potted register assembly has a bayonet
mount compatible with all Recordall meters. The bayonet mount
positions the register in any of four orientations for visual reading
convenience. The register can be removed from the meter without
disrupting water service.
Magnetic Drive Communication: The register detects movement of
the wet side meter magnet with magnetic sensors to provide reliable
and dependable meter monitoring.
Tamper-resistant Features: Unauthorized removal of the
register is inhibited by a tamper-resistant Torx® seal screw. Torx seal
screws are provided. Optional proprietary tamper-proof screws are
also available.
In addition, the register is resistant to magnetic tampering. The
register detects any attempted tamper or register removal and
displays the status indicator/alarm condition icon.
Construction: The housing of the register is constructed of an
engineered polymer enclosure and a polycarbonate lens. For
long-term performance, the enclosure is fully encapsulated,
weatherproof, and UV-resistant to withstand harsh environments
and to protect the electronics in flooded or submerged pit
applications. A patented epoxy potting comprises the register
bottom. Due to this unique sealing, the register exceeds all
applicable requirements of AWWA Standard C707.
Wire Connections: The register is available with dual output wire
connections. Both the scaled/unscaled wire and the 4-20 wire are
available with flying leads for easy connection in the field.
Operating Characteristics: The register is shipped in storage mode
so a meter status alarm is not triggered. In storage mode, the meter
model screen is displayed. Upon sensing two revolutions of the
meter magnet, the register goes into normal operation mode. The
display then automatically toggles between these modes:
• 9-digit consumption displays for 50 seconds
• Rate of flow displays for 5 seconds
• Meter model displays for 5 seconds
REG-DS-01969-EN-03 (January 2018)
Product Data Sheet
HR-LCD 4-20 Scaled/Unscaled Register
SPECIFICATIONS
Register Type
Register Display
Unit of Measure
Flow Rate Seconds, minutes, and hours
Numerals 7 mm (0.28 in.) high
Weight 11 ounces
Humidity 0…100% condensing
Temperature
Status Indicators
Scaled/Unscaled
Output
Max. Voltage
Pulse Width
Analog Output Two-wire/passive
Input Voltage Range
Max. Load Resistance
Battery
Battery Life
Permanently sealed, electronic LCD register with
scaled/unscaled and analog output, as well as a
field-programmable option
Status indicators, unit of measure, billing units,
automatic toggle between 9-digit consumption, rate
of flow, meter model
U.S. gallons, Imperial gallons, cubic feet, cubic meters,
and liters
Storage: – 40…140° F (– 40…60° C)
Max. ambient for 1 hr: 150° F (66° C)
Electronics & Display: 14…140° F (–10…60° C)
Visual icons for: meter functioning correctly, meter
alarm (indicates temperature limits exceeded,
magnetic tamper or register removal), reverse flow,
suspected leak, 30-day no usage, end of battery life
Solid-state relay
30V DC
Current
100 mA
50 ms (programmable 30…100 ms)
9…50V DC supply
Current
4…20 mA
50 Ohms + 50 Ohms (supply voltage - 9V)
(Ohms)
Lithium thionyl chloride AA cell, fully encapsulated
within register housing
10 years based on default settings and typical
operating range
DIMENSIONAL DRAWINGS
3.53 in.
(89.7 mm)
Figure 1: Top view Figure 2: Front view
2.27 in.
(57.7 mm)
Figure 3: Left side view
1.78 in.
(45.2 mm)
MEASUREMENT RESOLUTION
The HR-LCD 4-20 scaled/unscaled default output resolutions are as
noted below.
Recordall Disc Series
m
m
3
3
3
Analog
Output
20 mA
Set point
(gpm)
Analog
Output
20 mA
Set point
(gpm)
Analog
Output
20 mA
Set point
(gpm)
25
25
35
35
Model
Scaled
(pulse/unit)
Size
(in.)
gal ft3m3gal ft
Unscaled (pulse/unit)
3
m
LP 5/8 1 10 100 228.415 1708.661 60337.105 20
M25 5/8 1 10 100 198.334 1483.641 52391.084 25
M35 3/4 1 10 100 126.678 947.621 33462.863 35
M40 1 1 10 100 89.783 671.621 23716.632 40
M55 1 1 10 100 58.065 434.358 15338.279 55
M70 1 1 10 100 46.773 349.884 12355.278 70
M120 1-1/2
M170 2
0.10
1 10 23.866 178.533 6304.435 120
0.10
1 10 14.565 108.950 3847.303 170
Recordall Turbo Series
Scaled
Model
Size
(in.)
(pulse/unit)
gal ft3m3gal ft
T160 1-1/2 0.10 1 10 1.537 11.494 405.894 200
T200 2 0.10 1 10 1.537 11.494 405.894 310
T450 3 0.10 1 10 1.598 11.954 422.109 550
T1000 4 0.10 1 10 1.665 12.455 439.820 1250
T2000 6 0.01 0.10 1 0.150 1.123 39.639 2500
T3500 8 0.01 0.10 1 0.151 1.131 39.939 4500
T5500 10 0.01 0.10 1 0.198 1.481 52.308 7000
T6200 12 0.001 0.01 0.10 0.129 0.963 34.006 8800
T6600 16 0.001 0.01 0.10 0.016 0.116 4.107 13200
T1000 20 0.001 0.01 0.10 0.009 0.067 2.382 19800
Unscaled (pulse/unit)
3
Recordall Compound Series
Scaled
(pulse/unit)
Model
High Side
T200
Size
(in.)
gal ft3m3gal ft
2 0.10 1 10 1.537 11.494 405.894 200
Low Side M25 2 1 10 100 198.334 1483.641
High Side
T450
3 0.10 1 10 1.598 11.954 422.109 450
Low Side M25 3 1 10 100 198.334 1483.641
High Side
T1000
4 0.10 1 10 1.665 12.455 439.820 1000
Low side M35 4 1 10 100 126.678 947.621
High Side
T2000
6 0.01
0.10
Low Side M35 6 1 10 100 126.678 947.621
High Side
T3500
Low side
M120
0.10
8 0.01
8 0.10 1 10 23.866 178.533 6304.435 —
Unscaled (pulse/unit)
3
52391.084
52391.084
33462.863
1 0.150 1.123 39.639 2000
33462.863
1 0.151 1.131 39.939 —
OTE:N For Fire Service Meters and Assemblies, please refer to
appropriate Disc and TSM information provided above.
Control. Manage. Optimize.
Preso and Ellipse are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous
research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an
outstanding contractual obligation exists. © 2018 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Eastern Europe Branch Oce (for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus) | Badger Meter Europe | ul. Korfantego 6 | 44-193 Knurów | Poland | +48-32-236-8787
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0
Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836
China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412
Switzerland | Badger Meter Swiss AG | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11