INTRODUCTION
Product Inspection and Unpacking
Upon opening the shipping container, visually inspect the product and applicable accessories for any physical damage such as scratches, loose or broken parts, or any other sign of damage that may have occurred during shipment.
OTE:N If damage is found, request an inspection by the carrier’s
agent within 48 hours of delivery and file a claim with the carrier. A claim for equipment damage in transit is the sole responsibility of the purchaser.
License Requirements
This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes made by the user not approved by Badger Meter can void the user’s authority to operate the equipment. No license is required by the utility to operate an HR-E meter reading system.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
PRODUCT OVERVIEW
Description
The HR-E is a fully potted, eight-wheel absolute encoder. The encoder with glass lens is available factory pre-wired to Badger Meter AMR/AMI products, or may be spliced to other devices following the instructions. This version is permanently sealed to eliminate the intrusion of moisture, dirt, or other contaminants, and is suitable for installation in all environments, including meter pits subject to continuous submergence.
The HR-E with terminal screws features the same permanent sealing of the register's internal elements, but does not provide a moisture resistant enclosure. Therefore, it is suitable for indoor installation in a dry environment only, and is marked as such on the terminal screw cover.
Compatibility
The HR-E is designed for use with all current Badger Meter Recordall® Disc, Turbo Series, Compound Series, Combo Series and Fire Service meters and assemblies. Each HR-E is clearly identified on the face of the dial with an assembly number, unit of measure and meter model. The HR-E provides connectivity with Badger Meter ORION® and GALAXY® AMR/AMI endpoints, BadgerTouch® modules and other AMR/AMI technology solutions approved by Badger Meter.
CONNECTING AN ENCODER TO AN ENDPOINT
THE HR-E SHOULD ONLY BE CONNECTED TO A PRODUCT APPROVED BY BADGER METER. CONNECTION TO AN UNAPPROVED PRODUCT WILL VOID THE HR-E WARRANTY.
Badger Meter encoders have a factory installed three-conductor cable (brown) for connection to the endpoint. If the wire is cut or broken and requires a field splice after the initial installation, connect like-color wires to maintain proper installation. Badger Meter wiring standards use the black wire as the negative (–) conductor and the red as the positive (+) conductor.
Before proceeding with the installation, be certain that the meter type and size correspond, and that the proper encoder configuration has been supplied for the application.
ENC-UM-00237-EN-01 (June 2014)
Installation Data
Splicing Considerations
Splice connections made in pit environments require a pit field splice kit (62084-001), which can be ordered separately. See the
Field Splice Kit Installation Instructions available on our website.
ORION endpoints shipped factory pre-wired to a Badger Meter encoder require no splicing. All you do is mount the encoder to the meter and tighten the seal screw.
Wire Connections
The HR-E is available factory pre-wired to Badger Meter AMR/AMI products. The encoder is permanently sealed to eliminate the intrusion of moisture, dirt, or other contaminants, and is suitable for installation in all environments, including meter pits subject to continuous submergence.
The encoder is also available with potted, pre-sized wire harness available for connection to endpoints in the field. Standardized lead lengths are 3, 10, 25, and 75 feet.
In-line Connector
An in-line connector is an optional feature that allows connectivity to AMR/AMI devices without the need for a field splice kit.
HRE WITH TERMINAL SCREWS
The HR-E with terminal screws features the same permanent sealing of the encoder’s internal elements, but does not provide a moisture resistant enclosure. Therefore, the HR-E with optional terminal screw is suitable for indoor installation in a dry environment only, and is marked as such on the terminal screw cover.
The terminal screws are identified by the letters “R”, “B”, and “G” (standing for Red, Black and Green) molded into the screw cavity.
1. Strip approximately 1-1/2" of outer insulation sheath from the endpoint or other supplied wire using a coax stripping tool. Take care not to damage the inner wire insulation.
2. Unwind the outer foil shield from the cable and cut it o even with the outer sheath using the wire cutting pliers.
3. Cut the uninsulated shield drain wire even with the outer sheath.
4. Strip approximately 1/2" of insulation from the inner wires using the wire stripper.
5. Use a screwdriver to loosen the encoder terminal screws sufficiently to allow the bare wire ends to fit below the screw heads.
6. Bend the bare wire ends into hook shapes that will closely fit around the shafts of the terminal screws, and hold the hooks around the screw shafts while tightening the screws with the screwdriver. Do not overtighten screws. The hooks should be oriented with the openings to the right, so that tightening the screws (by turning to the right) will tend to draw the wire closer to the screw.
7. Place a plastic cable tie approximately 1/4" from the end of the outer insulation sheath. Tighten securely for strain relief. Remove excess cable tie.
8. Make sure that the cable exits the terminal screw cavity via the opening on the right side of the cavity wall and that cable tie resides on the interior of terminal cover.
9. Place the cover over the terminal screw cavity and secure by tightening the seal screw.
TESTING
After all connections are complete, test the entire installation including the HR-E, the wiring and the endpoint for proper operation in accordance with the instructions supplied with the endpoint.
INSTALLING THE HRE
Bayonet Mount
The bayonet mount positions the encoder in any of four orientations for visual reading convenience. The HR-E can be removed from the meter without disrupting water service.
Install the encoder on the water meter and secure it using the tamper-proof screw provided.
SPECIFICATIONS
Encoder Type Straight reading, permanently sealed,
magnetic drive
Unit of Measure U.S. Gallons, Cubic Feet, Cubic Meters, clearly
identified on encoder face
Number Wheels Eight with 5/32 inch high numerals Test Circle 360° circle with ten major increments with ten
divisions each
Weight 10 ounces Humidity 0…100% condensing when equipped with
potted lead wire, 0…95% non-condensing with screw-terminal wire connections
Temperature – 40…140° F (– 40…60° C ) Signal Output Industry Standard ASCII Format Visual Resolution 1/100th of Test Circle Electronic Resolution 8-dial resolution for AMR/AMI; 4, 5, 6, 7 or 8-dial
resolution for BadgerTouch
Signal Type 3-wire synchronous for AMR/AMI solutions
(red=clock/power, black=ground, green=data) 2-wire asynchronous for Touch solutions
Power Source External
Making Water Visible®
Making Water Visible, BadgerTouch and Recordall are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0 Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503 Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411 Slovakia | Badger Meter Slovakia s.r.o. | R acianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01 Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836 China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412