Badger Meter GMD Gage User Manual

LOCATION
A. The GMD can be line, bracket or panel mounted. B. For liquid applications the GMD should be installed below the
primary element in a level position (see diagram 1).
If recommended mounting is not possible, care must be taken to ensure that the gage is vented periodically.
C. For air/gas applications the GMD should be installed above the
primary element in a level position (see diagram 2).
Installation
gage should be as short as possible and should slope a mini­mum of 1 inch per foot.
B. Secure and support tubing to prevent sagging and or vibration. C. Care must be taken to ensure that the head heights are even. D. A Bleed line should be run from the GMD vent valves to a pan
or drain.
RECOMMENDED LIQUID INSTALLATION:
HL
VENT VALVES
Operation
**Preso strongly recommends the use of a single valve bypass or a 3-valve manifold with the GMD gage**
A. Identify Hi and Lo pressure inlets on the GMD. B. Ensure bypass valve is OPEN! If no bypass, extreme caution
must be used when opening Hi and Lo valves on the primary element. The valves must be opened simultaneously to prevent over pressurization and possible damage to the gage.
C. Connect GMD to corresponding Hi and Lo pressure taps of the
primary element (via 3-valve manifold, if being used).
D. Open Hi and Lo instrument valves on the primary element. E. Alternately open the Hi and Lo vent valves to purge the lines. F. When venting is complete, close the bypass valve to begin
taking readings.
Maintenance
Normal operation requires no maintenance. In case of dirt or scale build up flush meter with clean water or a compatible solvent.
>>> Contact your local representative if you have any <<<
>>> questions regarding PRESO products <<<
(DIAGRAM 1)
RECOMMENDED GAS INSTALLATION:
BYPASS VALVE
HL
(DIAGRAM 2)
BYPASS VALVE
VENT VALVES
Other Preso Products to Meet Your Needs
PRESO segmented wedge “COIN” are specifically designed and ideally suited to measure high viscosity fluids in very harsh and difficult applications.
PRESO annular devices, with the patented “ELLIPSE” self-averaging pitot tube are designed to measure liquids, gases and steam flows.
PRESO’s complete line of VENTURI; “Classical”, Venturi-Nozzle” and “Low­Loss” offer unparalleled accuracy and reliability, which surpasses industry standards.
PRESO “B+” metering/balancing valves provide unmatched accuracy and control for hydronic balancing as well as vacuum applications (Patented Lock Mechanism
Handle)
Installation and Instruction
Manual
U.S.A.: 42 Gateway Drive, Plattsburgh, NY 12901 Tel.: (518) 562-3182 • Fax: (518) 562-3227 Toll Free: (800) 632-7337 www.preso.com • info@preso.com
CERTIFIED
GMD Instructions 6-2000
CERTIFIED
Series GMD
Direct Read Gage
Loading...