Badger Meter FT-1, PFT-2, FT-2XP Specifications

FT-2XP
PFT-2
RST & RST-6P
Mechanical Unscaled Transmitters
Models FT-1, PFT-2, FT-2XP, RST, & RST-6P
The Models FT-1, PFT-2, FT-2XP, RST and RST-6P transmitters are designed for use with Badger Meter magnetic drive meters. Mounted on the meter, the transmitter can be wired to other pulse-operated instruments that have scaling capabilities and that can receive pulses from a reed switch.
The FT-2XP transmitter is identical to the PFT-2 except for the housing. The PFT-2 transmitter has a glass-filled plastic housing and a NEMA 4X rating. The FT-2XP transmitter housing is cast bronze and is CSA listed for use in hazardous locations. The FT-1 is offered only on the OP meter and is mounted in the OP housing directly with a stainless steel cover.
These transmitters do not have gear trains. The reed switch is directly coupled to the drive magnet within the meter.
OPERATION
The flow of liquid through the meter is measured by a disc or piston metering element. The motion of the metering element is transferred to a magnet which is located within the meter housing.
As the magnet turns, it causes the reed switch to open and close. Contact closures from the switch are transmitted to a remote batch controller or counter.
APPLICATIONS
These transmitters are normally connected to metering systems that have scaling capabilities and that can accept a reed switch pulse.
Typical applications would be chemical batching systems, chemical additive systems and other applications that require totalizing meter flow and monitoring rate of flow of fluid passing through the flow meter.
FEATURES
• FT-2XP transmitter is CSA listed for Class I, Division 1 , Group D
• Does not require external power
• Rugged, cast bronze housing (FT-2XP only)
• Corrosion resistant plastic enclosure (PFT-2 only)
• High temperature rating: is 250° F
• Watertight, NEMA 4 (FT-2XP) or NEMA 4X (PFT-2, RST)
• Watertight, NEMA 6P (RST-6P)
• Hermetically sealed reed switch output
• Compatible with most flow controllers and counters with scaling capabilities
• Stainless steel cover (FT-1 only)
XMT-DS-00738-EN-14 (October 2014)
Product Data Sheet
Mechanical Unscaled Transmitters, Models FT-1, PFT-2, FT-2XP, RST & RST-6P
white
WIRING DIAGRAM
black
green
white black
OTE:N The green wire is a ground wire and is found only on the
FT-2XP model.
SPECIFICATIONS
10 W max., 200V DC max., 500 mA DC max.
FT-2XP Rating
or 7 W, 110V AC max., 350 mA AC max. resistive
Duty Cycle Approximately 50%
Operating Temperature
Weight
250° F maximum
Bronze, 5 lb Plastic, 2 lb
SCALE FACTOR CALCULATION
Scale Factor =
See the chart to the right for the average number of output pulses per US gallon for your particular meter. For more precise calculations, use the information on the transmitter data plate when figuring scale factors.
Example:
Compute the scale factor for a 1" OP meter. You want to measure the flow to the nearest 0.1 US gallon.
Scale Factor =
10
76.64
Pulses per US gallon wanted
Transmitter output in pulses per US gallon
= 0.1305
METER KFACTOR CHART
Transmitter
Size
(Inches)
Meter Model
Output (Pulse per US Gallon
5/8" RCDL 25 198.340 52.396
3/4" RCDL 35 126.671 33.463
1" RCDL 40 89.781 23.718
1" RCDL 70 46.751 12.350
1-1/2" RCDL 120 23.867 6.305
2" RCDL 170 14.565 3.848
1/2" OP/FT-2XP 222.960 58.899
1/2" OP/PFT-2 222.960 58.899
1/2" OP/FT-1 111.500 29.455
1" OP 76.640 20.246
2" OP 20.600 5.4419
1-1/2" 160 Turbo Series 1.5366 0.4059
2" 200 Turbo Series 1.5366 0.4059
3" 450 Turbo Series 1.5982 0.4222
4" 1000 Turbo Series 1.6650 0.4399
6" 2000 Turbo Series 0.1501 0.0396
8" 3500 Turbo Series 0.1514 0.0400
10" 5500 Turbo Series 0.1980 0.0523
12" 6200 Turbo Series 0.1287 0.0340
16" 6600 Turbo Series 0.0155 0.0041
20" 10000 Turbo Series 0.0090 0.0024
Meter Type Bronze Plastic
RCDL Disc M25, M35, M40, M70 FT-2XP PFT-2
OP 1/2", 1", 2" FT-2XP PFT-2, FT-1
Turbo Series FT-2XP PFT-2
RCDL Disc M120, M170 RST, RST-6P
Transmitter
Output
(Pulse/Liter)
Enter 0.1305 into the controller program to read the meter flow to
the nearest 0.1 of a US gallon
Control. Manage. Optimize.
Trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0 Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503 Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411 Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01 Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836 China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412 Legacy Document Number: ITB-075-10-EN PN 53406-075